• Title/Summary/Keyword: titanium surface

Search Result 1,162, Processing Time 0.025 seconds

Machining Characteristics of Ti-6Al-4V Thread (Ti-6Al-4V 티타늄 합금나사의 절삭 특성)

  • Kim, Hyung-Sun;Choi, Jong-Guen;Kim, Dong-Min;Lyu, Min-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.5
    • /
    • pp.514-520
    • /
    • 2009
  • Titanium is one of the most attractive materials due to their superior properties of high specific strength and excellent corrosion resistance. The applications in aerospace and medical industries demand machining process more frequently to obtain more precise products. Machining of titanium is faced with strong challenges such as increased component complexity i.e. airframe components manufacturing processes. The machining cost on titanium have traditionally demanded high cutting tool consumable cost and slow machining cycle times. Similarly, the high wear of the cutting tools restricts the cutting process capabilities. Titanium screws applied to fasten parts In the several corrosion environment. In the thread cutting of titanium alloys, the key point for successful work is to select proper cutting methods and tool materials. This study suggests a guidance fur selecting the cutting methods and the tool materials to improve thread quality and productivity. Some experiments investigate surface roughnesses, cutting forces and tool wear with change of various cutting parameters including tool materials, cutting methods, cutting speed. As the results, the P10 type insert tip was assured of the best for thread cutting of Ti-6Al-4V titanium alloy. Also the initial depth of infeed was desirable to use the value below 0.5mm as the uniform cutting area method is applied.

  • PDF

Study on Electrochemical Characteristics and Fabrication of Catalytic Electrode (복합 촉매 전극의 제조 및 전기화학적 특성에 관한 연구)

  • 민병승;정원섭;김광호;민병철;이미혜
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.6
    • /
    • pp.401-407
    • /
    • 2002
  • Most of organic compounds discharged from industrial wastewater are treated by chemical oxidation, adsorption and biodegradable process. This process has been demanded a new advanced environmental wastewater treatment process. From this point of view, an electrochemical oxidation process using electrocatalysts has been developed for the destruction of organic compounds. Through this study, a ruthenium oxide/iridium oxide supported on titanium expanded metal was fabricated by thermal decomposition method and its performance was excellent during this experiment.

Surface characteristics of thermally treated titanium surfaces

  • Lee, Yang-Jin;Cui, De-Zhe;Jeon, Ha-Ra;Chung, Hyun-Ju;Park, Yeong-Joon;Kim, Ok-Su;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.3
    • /
    • pp.81-87
    • /
    • 2012
  • Purpose: The characteristics of oxidized titanium (Ti) surfaces varied according to treatment conditions such as duration time and temperature. Thermal oxidation can change Ti surface characteristics, which affect many cellular responses such as cell adhesion, proliferation, and differentiation. Thus, this study was conducted to evaluate the surface characteristics and cell response of thermally treated Ti surfaces. Methods: The samples were divided into 4 groups. Control: machined smooth titanium (Ti-S) was untreated. Group I: Ti-S was treated in a furnace at $300^{\circ}C$ for 30 minutes. Group II: Ti-S was treated at $500^{\circ}C$ for 30 minutes. Group III: Ti-S was treated at $750^{\circ}C$ for 30 minutes. A scanning electron microscope, atomic force microscope, and X-ray diffraction were used to assess surface characteristics and chemical composition. The water contact angle and surface energy were measured to assess physical properties. Results: The titanium dioxide ($TiO_2$) thickness increased as the treatment temperature increased. Additional peaks belonging to rutile $TiO_2$ were only found in group III. The contact angle in group III was significantly lower than any of the other groups. The surface energy significantly increased as the treatment temperature increased, especially in group III. In the 3-(4,5-Dimethylthiazol- 2-yl)-2,5-diphenyltetrazolium bromide assay, after 24 hours of incubation, the assessment of cell viability showed that the optical density of the control had a higher tendency than any other group, but there was no significant difference. However, the alkaline phosphatase activity increased as the temperature increased, especially in group III. Conclusions: Consequently, the surface characteristics and biocompatibility increased as the temperature increased. This indicates that surface modification by thermal treatment could be another useful method for medical and dental implants.

MECHANICAL PROPERTIES OF TIN COATED FILM WITH VARIOUS COATING THICKNESS ON TITANIUM ALLOY (타이타늄 합금에 다양한 두께로 코팅된 TiN 피막의 기계적 성질)

  • Lee, Jae-Yun;Oh, Dong-Joon;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.675-686
    • /
    • 2007
  • Statement of problem: Titanium nitride(TiN) coatings are the most general and popular coating method and used to improve the properties of metallic surface for industrial purposes. When TiN coating applied to the abutment screw, frictional resistance would be reduced, as a results, the greater preload and prevention of the screw loosening could be expected. Purpose: The purpose of this study was to investigate mechanical properties of TiN coated film of various coating thickness on the titanium alloy surface and to evaluate proper coating thickness. Material and method: 95 Titanium alloy (Ti-6Al-4V) discs of 15 mm in diameter and 3 mm in thickness were prepared for TiN coating and divided into 7 groups in this study. Acceding to coating deposition time (CDT) with TiN by using Arc ion plating, were divided into 7 groups : Group A (CDT 30min), Group B (CDT 60min), Group C (CDT 90min), Group D (CDT 120min), Group E (CDT 150min), Group F(CDT 180min) and Group G (no CDT) as a control group. TiN coating surface was observed with Atomic Force Microscope(AFM), field emission scanning electron microscopy(FE-SEM) and examined with scratch tester, wear tester. Result: 1. Coating thickness fir each coated group was increased in proportion to coating deposition time. 2. Surface of all coated groups except Group A was homogeneous and smooth. However, surface of none coated Group G had scratch. 3. Adhesion strength for each coated group was increased in proportion to coating deposition time. 4. Wear resistance for each coated group was increased in proportion to coating deposition time. 5. Surface roughness in Group A, B, C was increased in proportion to coating deposition time. But, surface roughness in Group D, E, F was showed decreased tendency in proportion to coating deposition time. Conclusion: According to coating deposition time, mechanical properties of TiN coated film were changed. It was considered that 120 minutes coating deposition time ($1.32{\mu}m$ in coating thickness) is necessary.

Effect of Titanium Coating on Cell Adhesion and Extracellular Matrix Formation in Human Osteoblast-like MG-63 Cells

  • Lee, Jae-Bum;Seo, Sang-Hui;Kim, Yu-Ri;Shin, Sang-Wan;Kim, Meyoung-Kon;Ryu, Jae-Jun
    • Molecular & Cellular Toxicology
    • /
    • v.4 no.3
    • /
    • pp.192-198
    • /
    • 2008
  • A variety of titanium (Ti) and its alloys are used in the clinical procedures of bone regeneration for periodontal and dental implant therapies. This study was performed to determine the effect of different surface dental implant materials on biologic responses of a MG-63 human osteoblast-like cell line. MG-63 cells were cultured on Ti coated with hydroxyapatite (HA), calcium metaphosphate (CMP), anodized (A), which compared with non-coated Ti (control). The appearances of surface of dental implant materials and the morphology of these cells were assessed by scanning electron microscopy (SEM). The gene expression profiles of MG-63 cells cultured on Ti were examined by human cDNA microarray (1,152 elements). The expression of several genes was up- and down-regulated by different surfaces of dental implant materials. Interesting, the genes correlated with cellular adhesion and extra cellular matrix (ECM) formation were enhanced, in accordance surface morphology of the dental implant materials used.

Comparative Biocompatibility of Metal Implants in Connective Tissue of Abdominal Wall of the Mouse (마우스의 복벽에서 결합조직에 대한 금속 이식체의 생체적합성 비교)

  • 김국렬;이민호;김병일;민병운;김명훈;최은상;조현욱
    • Toxicological Research
    • /
    • v.20 no.1
    • /
    • pp.13-20
    • /
    • 2004
  • The purpose of this study is to compare the biocompatibility of commercial purity Ti, Ti-6AI-4V and Ti-6AI-7Nb alloy specimens with and without surface treatment in mouse abdominal connective tissue in vivo. Each metal was implanted into specific abdominal subdermal tissue site of female mouse. After 4 weeks, the implants were removed and abdominal tissues were fixed, dehydrated and embedded in glycol methacrylate resin. And the tissues were histologically prepared for microscopical evaluation. It was characterized by the presence of connective tissue with fibrous capsule surrounding the implant. The fibrous tissue surrounding the implant was studied to determine the biocompatibility of implanted metals. The average thickness of the fibrous capsule formed around the implant was much thinner for the hydrogen peroxide added hydrochloric acid solution-treated specimen than for the others. The results of this evaluation indicate that modification of the surface properties of titanium and titanium alloy implants changes the biological properties in the abdominal connective tissue. In conclusion, these observations suggest that the proper surface treatment performed in the study is effective for the improvement of biocompatibility.

Surface Characteristics and Biocompatibility of MoS2-coated Dental Implant (MoS2 코팅된 치과용 임플란트의 표면특성과 생체적합성)

  • Min-Ki Kwon;Jun-Sik Lee;Mi Eun Kim;Han-Cheol Choe
    • Corrosion Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.72-81
    • /
    • 2024
  • The Ti-6Al-4V alloy is widely used as an implant material due to its higher fatigue strength and strengthto-weight ratio compared to pure titanium, excellent corrosion resistance, and bone-like properties that promote osseointegration. For rapid osseointegration, the adhesion between the titanium surface and cellular biomolecules is crucial because adhesion, morphology, function, and proliferation are influenced by surface characteristics. Polymeric peptides and similar coating technologies have limited effectiveness, prompting a demand for alternative materials. There is growing interest in 2D nanomaterials, such as MoS2, for good corrosion resistance and antibacterial, and bioactive properties. However, to coat MoS2 thin films onto titanium, typically a low-temperature hydrothermal synthesis method is required, resulting in the synthesis of films with a toxic 1T@2H crystalline structure. In this study, through high-temperature annealing, we transformed them into a non-toxic 2H structure. The implant coating technique proposed in this study has good corrosion resistance and biocompatibility, and antibacterial properties.

The Effect of Erythrosine-mediated Photodynamic Therapy on Intraorally Formed Biofilm on Titanium Surface

  • Park, Se-Hwan;Lee, Si-Young;Chang, Beom-Seok;Um, Heung-Sik;Lee, Jae-Kwan
    • International Journal of Oral Biology
    • /
    • v.37 no.3
    • /
    • pp.103-108
    • /
    • 2012
  • The purpose of this study was to assess the efficacy of photodynamic therapy (PDT) using erythrosine and a halogen light source to treat a biofilm formed on a machined surface titanium disk in vivo. Ten volunteers carried an acrylic appliance containing six machined surface titanium disks on the upper jaw over a period of five days. After the five days of biofilm formation period, the disks were removed. PDT using 20 ${\mu}M$ erythrosine and halogen light was then applied to the biofilms formed on the disks. Experimental samples were divided into a negative control group (no erythrosine and no irradiation), E0 group (erythrosine 60s + no irradiation), E30 group (erythrosine 60s + halogen light 30s), and E60 group (erythrosine 60s + halogen light 60s). Following PDT, the bacteria in the biofilm were found to be detached from each disk. Each suspension with detached bacteria were diluted and cultivated on a blood-agar plate for five days under anaerobic conditions. The cultivated bacterial counts in the E60 group were significantly lower than the control group (86.4%) or E0 group (76.7%). In the experimental groups also, the light exposure time and bacterial counts showed a negative correlation. In conclusion, PDT using erythrosine and halogen light has bactericidal effects on biofilms formed on a titanium disk in vivo. Notably, applying 20 ${\mu}M$ erythrosine and 60 seconds of halogen light irradiation had a significantly potent effect.

The effect of photodynamic therapy on Aggregatibacter actinomycetemcomitans attached to surface-modified titanium

  • Cho, Kyungwon;Lee, Si Young;Chang, Beom-Seok;Um, Heung-Sik;Lee, Jae-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.38-45
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the effect of photodynamic therapy (PDT) using erythrosine and a green light emitting diode (LED) light source on biofilms of Aggregatibacter actinomycetemcomitans attached to resorbable blasted media (RBM) and sandblasted, large-grit, acid-etched (SLA) titanium surfaces in vitro. Methods: RBM and SLA disks were subdivided into four groups, including one control group and three test groups (referred to as E0, E30, E60), in order to evaluate the effect of PDT on each surface. The E0 group was put into $500{\mu}L$ of $20{\mu}M$ erythrosine for 60 seconds without irradiation, the E30 group was put into erythrosine for 60 seconds and was then irradiated with a LED for 30 seconds, and the E60 group was put into erythrosine for 60 seconds and then irradiated with a LED for 60 seconds. After PDT, sonication was performed in order to detach the bacteria, the plates were incubated under anaerobic conditions on brucella blood agar plates for 72 hours at $37^{\circ}C$, and the number of colony-forming units (CFUs) was determined. Results: Significant differences were found between the control group and the E30 and E60 groups (P<0.05). A significantly lower quantity of CFU/mL was found in the E30 and E60 groups on both titanium disk surfaces. In confocal scanning laser microscopy images, increased bacterial death was observed when disks were irradiated for a longer period of time. Conclusions: These findings suggest that PDT using erythrosine and a green LED is effective in reducing the viability of A. actinomycetemcomitans attached to surface-modified titanium in vitro.

An Overview of Research Trends in Antibacterial Coatings on Titanium Implants (임상가를 위한 특집 3 - 티타늄 임플란트의 항균코팅 동향)

  • Kim, Woo-Hyun;Kim, Kyoung-Nam
    • The Journal of the Korean dental association
    • /
    • v.48 no.2
    • /
    • pp.113-118
    • /
    • 2010
  • Titanium and titanium alloys are the most common materials used for dental and biomedical implants, owing to their biocompatibility and favourable mechanical properties. However infection of the region surrounding a dental implant by pathogenic microorganisms is a significant factor in implant failure. Prevention and control of microbial colonization of implant surfaces is considerable interest to the biomedical community. One important strategy is to render the implant surface antibacterial by impeding the formation of biofilm. A number of approaches have been proposed for this purpose. Therefore, we reviewed the researches of antibacterial coatings on titanium implants in this articles.