Browse > Article

An Overview of Research Trends in Antibacterial Coatings on Titanium Implants  

Kim, Woo-Hyun (Department and Research Institute of Dental Biomaterials and Bioengineering, and Research Institute of Orofacial Hard Tissue Regeneration College of Dentistry, Yonsei University)
Kim, Kyoung-Nam (Department and Research Institute of Dental Biomaterials and Bioengineering, and Research Institute of Orofacial Hard Tissue Regeneration College of Dentistry, Yonsei University)
Publication Information
The Journal of the Korean dental association / v.48, no.2, 2010 , pp. 113-118 More about this Journal
Abstract
Titanium and titanium alloys are the most common materials used for dental and biomedical implants, owing to their biocompatibility and favourable mechanical properties. However infection of the region surrounding a dental implant by pathogenic microorganisms is a significant factor in implant failure. Prevention and control of microbial colonization of implant surfaces is considerable interest to the biomedical community. One important strategy is to render the implant surface antibacterial by impeding the formation of biofilm. A number of approaches have been proposed for this purpose. Therefore, we reviewed the researches of antibacterial coatings on titanium implants in this articles.
Keywords
Titanium; Implant; Antibacterial coating; Infection; Drug delivery;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Choi JY, Kim KH, Choy KC, Oh KT, Kim KN. Photocatalystic antibacterial effect of TiO2 films formed on Ti and TiAg exposed to Lactobacillus acidophilus. J Biomed Mater Res 2007; 80B: 353-359   DOI   ScienceOn
2 Zhang F, Zhang Z, Zhu X, Kang ET, Neoh KG. Silk-functionalized titanium surface for enhancing osteoblast functions and reducing bacterial adhesion. Biomaterials 2008; 29: 4751-4759   DOI   ScienceOn
3 Edupuganti OP, Antoci V Jr, King SB, Jose B, Adams CS, Parvizi J, Shapiro IM, Zeiger AR, Hickok NJ, Wickstrom E. Covalent bonding of vancomycin to Ti6Al4V alloy pins provides longterm inhibition of Staphylococcus aureus colonization. Bioorg Med Chem Lett 2007; 17: 2692-2696   DOI   ScienceOn
4 Melaiye AYW. Silver and its application as an antimicrobial agent. Expert Opin Ther Pat 2005; 15: 125-130   DOI   ScienceOn
5 Zhang W, Luo Y, Wang H, Jiang J, Pu S, Chu PK. Ag and Ag/N plasma modification of polyethylene for the enhancement of antibacterial properties and cell growth/proliferation. Acta Biomater 2008; 4: 2028-2036   DOI   ScienceOn
6 Nablo BJ, Rothrock AR, Schoenfisch MH. Nitric oxide-releasing sol-gel as antibacterial coatings for orthopedic implants. Biomaterials 2005; 26: 917-924   DOI   ScienceOn
7 Stigter M, Bezemer J, de Groot K, Layrolle P. Incorporation of different antibiotics into carbonated hydroxyapatite coatings on titanium implants, release and antibiotic efficacy. J Control Release 2004; 99: 127-137   DOI   ScienceOn
8 Zhao L, Chu PK, Zhang Y, Wu Z. Antibacterial coatings on titanium implants. J Biomed Matter Res A 2009; 91B: 470-480   DOI   ScienceOn
9 Harris LG, Tosatti S, Wieland M, Textor M, Richards RG. Staphylococcus aureus adhesion to titanium oxide surfaces coated with nonfunctionalized and peptide-functionalized poly(Llysine)- grafted-poly(ethylene glycol) copolymer. Biomaterials 2004; 25: 4135-4148   DOI   ScienceOn
10 Chen W, Liu Y, Courtney HS, Bettenga M, Agrawal CM, Bumgardner JD, Ong J L. In vitro anti-bacterial and biological properties of magnetron co-sputtered silver-containing hydroxyapatite coating. Biomaterials 2006; 27: 5512-5517   DOI   ScienceOn
11 Kakoli D, Susmita B, Amit B, Balu K, Bruce L. Gibbins. Surface coating for improvement of bone cell materials and antimicrobial activities of Ti implant. J Biomed Mater Res 2008; 87B: 455-460   DOI   ScienceOn
12 Nablo BJ, Schoenfisch MH. In vitro cytotoxicity of nitric oxide-releasing sol-gel derived materials. Biomaterials 2005; 26: 4405-4415   DOI   ScienceOn
13 MacMicking J, Xie QW, Nathan C. Nitric oxide and macrophage function. Annu Rev Immunol 1997; 15: 323-350   DOI   ScienceOn
14 Hetrick EM, Schoenfisch MH. Antibacterial nitric oxide releasing xerogels: Cell viability and parallel plate flow cell adhesion studies. Biomaterials 2007; 28: 1948-1956   DOI   ScienceOn
15 Gallardo-Moreno AM, Pacha-Olivenza MA, Saldana L, Perez-Giraldo C, Bruque JM, Vilaboa N, Gonzalez-Martin ML. In vitro biocompatibility and bacterial adhesion of UV irradiation. Acta Biomater 2009; 5: 181-192   DOI   ScienceOn
16 Legeay G, Poncin-Epaillard F, Arciola CR. New surfaces with hydrophilic /hydrophobic characteristics in relation to (no)bioadhesion. Int J Artif Organs 2006; 29: 453-461
17 Aita H, Hori N, Takeuchi M, Suzuki T, Yamada M, Anpo M, Ogawa T. The effect of ultraviolet functionalization of titanium on integration with bone. Biomaterials 2009; 30: 1015-1025   DOI   ScienceOn
18 Del Curto B, Brunella MF, Giordano C, Pedeferri MP, Valtulina V, Visai L, Cigada A. Decreased bacteria adhesion to surface-treated titanium. Int J Artif Organ 2005; 28: 718-730   DOI
19 Price JS, Tencer AF, Arm DM, Bohach GA. Controlled release of antibiotics from coated orthopedic implants. J Biomed Mater Res 1996; 30: 281-286   DOI
20 Gollwitzer H, Ibrahim K, Meyer H, Mittelmeier W, Busch R, Stemberger A. Antibacterial poly(D,Llactic acid) coating of medical implants using a biodegradable drug delivery technology. J Antimicrob Chemother 2003; 51: 585-591   DOI   ScienceOn
21 Harris LG, Mead L, Müller-Oberländer E, Richards RG. Bacteria and cell cytocompatibility studies on coated medical grade titanium surfaces. J Biomed Mater Res 2006; 78A: 50-58   DOI   ScienceOn
22 Antoci V Jr, Adams CS, Parvizi J, Davidson HM, Composto RJ, Freeman TA, Wickstrom E, Ducheyne P, Jungkind D, Shapiro IM, Hickok NJ. The inhibition of Staphylococcus epidermidis biofilms formation by vancomycin-modified titanium alloy and implications for the treatment of periprosthetic infection. Biomaterials 2008; 29: 4684-4690   DOI   ScienceOn
23 Wolf J, Sternberg K, Behrend D, Schmitz KP, von Schwanewede H. Drug release of coated dental implant neck region to improve tissue integration. Biomed Tech 2009; 54(4): 219-217   DOI   ScienceOn
24 Percival SL, Bowler PG, Russell D. Bacterial resistance to silver in wound care. J Hos Infect 2005; 60: 1-7   DOI   ScienceOn
25 Bosetti M, Masse A, Tobin E, Cannas M. Silver coated materials for external fixation devices: In vitro biocompatibility and genotoxicity. Biomaterials 2002; 23: 887-892   DOI   ScienceOn
26 Hardes J, Ahrens H, Gebert C, Streitbuerger A, Buerger H, Erren M, Gunsel A, Wedemeyer C, Saxler G, Winkelmann W, Gosheger G. Lack of toxicological side-effects in silver-coated megaprotheses in humans. Biomaterials 2007; 28: 2869-2875   DOI   ScienceOn
27 Ewald A, Glückermann SK, Thull R, Gbureck U. Antimicrobial titanium/siver PVD coatings on titanium. Biomed Eng Online 2006; 5: 22   DOI   ScienceOn
28 Ratner D, Hoffman S, Schoen J, Lemons, J. An Introduction to Materials in Medicine: Biomaterials Science. 2nd Edition. Elsevier Academic Press. 2004.
29 Le Guehennec L, Soueidan A, Layrolle P, Amouriq Y.Le Guehennec L, Soueidan A, Layrolle P, Amouriq Y. Surface treatments of titanium dental implants for rapid osseointegration. Dent Mater 2007; 23: 844-854   DOI   ScienceOn
30 Daugaard H, Elmengaard B, Bechtold JE, Jensen T, Soballe K. The effect on bone growth enhancement of implant coatings with hydroxyapatite and collagen deposited electrochemically and by plasma spray. J Biomed Matter Res A 2009; 92A: 913-921.
31 Kim TI, Jang JH, Kim HW, Knowles JC, Ku Y. Biomimetic approach to dental implants. Curr Pharm Des 2008; 14(22): 2201-2211   DOI   ScienceOn
32 Darouiche RO. Treatment of infections associated with surgical implants. N Engl J Med 2004; 350: 1422-1429   DOI   ScienceOn
33 Harris LG, Richards RG. Staphylococci and implant surfaces: A review. Injury 2006; 37(Suppl 2): S3-S14
34 Duran LW. Preventing medical device related infections. Med Device Technol 2000; 11: 14-17
35 Radin S, Campbell JT, Ducheyne P, Cuckler JM. Calcium phosphate ceramic coatings as carriers of vancomycin. Biomaterials 1997; 21: 243-249
36 Aebli N, Krebs J, Schwenke D, Stich H, Schawalder P, Theis JC. Degradation of hydroxyapatite coating on a well-functioning femoral component. J Bone Joint Surg Br 2003, 85(4): 499-503   DOI   ScienceOn