• Title/Summary/Keyword: titanium surface

Search Result 1,174, Processing Time 0.026 seconds

Immobilization and Performance of Penicillin G Acylase on Magnetic Ni0.7Co0.3Fe2O4@SiO2-CHO Nanocomposites

  • Lv, Zhixiang;Yu, Qingmei;Wang, Zhou;Liu, Ruijiang
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.6
    • /
    • pp.913-922
    • /
    • 2019
  • Magnetic $Ni_{0.7}Co_{0.3}Fe_2O_4$ nanoparticles that were prepared via the rapid combustion process were functionalized and modified to obtain magnetic $Ni_{0.7}Co_{0.3}Fe_2O_4@SiO_2-CHO$ nanocomposites, on which penicillin G acylase (PGA) was covalently immobilized. Selections of immobilization concentration and time of fixation were explored. Catalytic performance of immobilized PGA was characterized. The free PGA had greatest activity at pH 8.0 and $45^{\circ}C$ while immobilized PGA's activities peaked at pH 7.5 and $45^{\circ}C$. Immobilized PGA had better thermal stability than free PGA at the range of $30-50^{\circ}C$ for different time intervals. The activity of free PGA would be 0 and that of immobilized PGA still retained some activities at $60^{\circ}C$ after 2 h. $V_{max}$ and $K_m$ of immobilized PGA were 1.55 mol/min and 0.15 mol/l, respectively. Free PGA's $V_{max}$ and $K_m$ separately were 0.74 mol/min and 0.028 mol/l. Immobilized PGA displayed more than 50% activity after 10 successive cycles. We concluded that immobilized PGA with magnetic $Ni_{0.7}Co_{0.3}Fe_2O_4@SiO_2-CHO$ nanocomposites could become a novel example for the immobilization of other amidohydrolases.

Development of Uniaxial Tensile Test Method to Evaluate Material Property of Tungsten Carbide-Cobalt Alloys for Cold Forging Dies (냉간단조 금형 WC-Co합금의 인장시험방법 개발 및 물성평가)

  • Kwon, I.W.;Seo, Y.H.;Jung, K.H.
    • Transactions of Materials Processing
    • /
    • v.27 no.6
    • /
    • pp.370-378
    • /
    • 2018
  • Cold forging, carried out at room temperature, leads to high dimensional accuracy and excellent surface integrity as compared to other forging methods such as warm and hot forgings. In the cold forging process, WC-Co (Tungsten Carbide-Cobalt) alloy is the mainly used material as a core dies because of its superior hardness and strength as compared to other structural materials. For cold forging, die life is the most significant factor because it is directly related to the manufacturing cost due to periodic die replacement in mass production. To investigate die life of WC-Co alloy for cold forging, mechanical properties such as strength and fatigue are essentially necessary. Generally, uniaxial tensile test and fatigue test are the most efficient and simplest testing method. However, uniaxial tension is not efficiently application to WC-Co alloy because of its sensitivity to alignment of the specimen due to its brittleness and difficulty in thread machining. In this study, shape of specimen, tools, and testing methods, which are appropriate for uniaxial tensile test for WC-Co alloy, are proposed. The test results such as Young's modulus, tensile strength and stress-strain curves are compared to those in previous literature to validate the proposed testing methods. Based on the validation of test results it was concluded that the newly developed testing method is applicable to other cemented carbides like Titanium carbides with high strength and brittleness, and also can be utilized to carry out fatigue tests for further investigation on die life of cold forging.

Microstructure and Mechanical Property of Ti-Mn-Cu Alloys with Magnetic Pulsed Compaction (자기펄스성형이 적용된 Ti-Mn-Cu 합금의 미세구조 및 기계적 특성)

  • Yun, Ye Jun;Park, Chun Woong;Choi, Won June;Byun, Jongmin
    • Journal of Powder Materials
    • /
    • v.28 no.1
    • /
    • pp.20-24
    • /
    • 2021
  • Ti-based alloys are widely used in biomaterials owing to their excellent biocompatibility. In this study, Ti-Mn-Cu alloys are prepared by high-energy ball milling, magnetic pulsed compaction, and pressureless sintering. The microstructure and microhardness of the Ti-Mn-Cu alloys with variation of the Cu addition and compaction pressure are analyzed. The correlation between the composition, compaction pressure, and density is investigated by measuring the green density and sintered density for samples with different compositions, subjected to various compaction pressures. For all compositions, it is confirmed that the green density increases proportionally as the compaction pressure increases, but the sintered density decreases owing to gas formation from the pyrolysis of TiH2 powders and reduction of oxides on the surface of the starting powders during the sintering process. In addition, an increase in the amount of Cu addition changes the volume fractions of the α-Ti and β-Ti phases, and the microstructure of the alloys with different compositions also changes. It is demonstrated that these changes in the phase volume fraction and microstructure are closely related to the mechanical properties of the Ti-Mn-Cu alloys.

Effect of nicotine on orthodontic tooth movement and bone remodeling in rats

  • Lee, Sung-Hee;Cha, Jung-Yul;Choi, Sung-Hwan;Kim, Baek-il;Cha, Jae-Kook;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.51 no.4
    • /
    • pp.282-292
    • /
    • 2021
  • Objective: To quantitatively analyze the effect of nicotine on orthodontic tooth movement (OTM) and bone remodeling in rats using micro-computed tomography and tartrate-resistant acid phosphatase immunostaining. Methods: Thirty-nine adult male Sprague-Dawley rats were randomized into three groups: group A, 0.5 mL normal saline (n = 9, 3 per 3, 7, and 14 days); group B, 0.83 mg/kg nicotine (n = 15, 5 per 3, 7, and 14 days); and group C, 1.67 mg/kg nicotine (n = 15, 5 per 3, 7, and 14 days). Each animal received daily intraperitoneal injections of nicotine/saline from the day of insertion of identical 30-g orthodontic force delivery systems. A 5-mm nickel-titanium closed-coil spring was applied between the left maxillary first molar (M1) and the two splinted incisors. The rate of OTM and volumetric bone changes were measured using micro-computed tomography. Osteoclasts were counted on the mesial alveolar bone surface of the distobuccal root of M1. Six dependent outcome variables, including the intermolar distance, bone volume fraction, bone mineral density, trabecular thickness, trabecular volume, and osteoclast number, were summarized using simple descriptive statistics. Nonparametric Kruskal-Wallis tests were used to evaluate differences among groups at 3, 7, and 14 days of OTM. Results: All six dependent outcome variables showed no statistically significant among group-differences at 3, 7, and 14 days. Conclusions: The findings of this study suggest that nicotine does not affect OTM and bone remodeling, although fluctuations during the different stages of OTM in the nicotine groups should be elucidated in further prospective studies.

Yield Functions Based on the Stress Invariants J2 and J3 and its Application to Anisotropic Sheet Materials (J2 와 J3 불변량에 기초한 항복함수의 제안과 이방성 판재에의 적용)

  • Kim, Y.S;Nguyen, P.V.;Kim, J.J.
    • Transactions of Materials Processing
    • /
    • v.31 no.4
    • /
    • pp.214-228
    • /
    • 2022
  • The yield criterion, or called yield function, plays an important role in the study of plastic working of a sheet because it governs the plastic deformation properties of the sheet during plastic forming process. In this paper, we propose a novel anisotropic yield function useful for describing the plastic behavior of various anisotropic sheets. The proposed yield function includes the anisotropic version of the second stress invariant J2 and the third stress invariant J3. The anisotropic yield function newly proposed in this study is as follows. F(J2)+ αG(J3)+ βH (J2 × J3) = km The proposed yield function well explains the anisotropic plastic behavior of various sheets by introducing the parameters α and β, and also exhibits both symmetrical and asymmetrical yield surfaces. The parameters included in the proposed model are determined through an optimization algorithm from uniaxial and biaxial experimental data under proportional loading path. In this study, the validity of the proposed anisotropic yield function was verified by comparing the yield surface shape, normalized uniaxial yield stress value, and Lankford's anisotropic coefficient R-value derived with the experimental results. Application for the proposed anisotropic yield function to aluminum sheet shows symmetrical yielding behavior and to pure titanium sheet shows asymmetric yielding behavior, it was shown that the yield curve and yield behavior of various types of sheet materials can be predicted reasonably by using the proposed new yield anisotropic function.

Development of Multi-rod Type Ag-AgCl Electrodes for an Underwater Electric Field Sensor (수중 전기장 센서용 다중 막대형 은-염화은 전극 개발)

  • Lee, Sangkyu;Yang, Chang-Seob;Chung, Hyun-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.45-50
    • /
    • 2022
  • Multi-rod type Ag-AgCl electrodes have been developed for use in underwater electric field sensors. The developed cylindrical electrode had a diameter of 50 mm and a height of 130 mm. The electrode had five Ag-AgCl rods with a diameter of 2 mm and a height of 80 mm to enlarge the reaction surface area. Each Ag-AgCl rod was fabricated under the same conditions as the usual anodizing method in an electrolyte. The two developed electrodes were placed in the center of a 500-mm long, 400-mm wide, and 300-mm high acrylic tank filled with artificial seawater, at an interval of 100 mm, to evaluate their characteristics as uniaxial underwater electric field sensors. The underwater external electric field was generated using titanium plate electrodes installed at both ends of the tank. The noise level at 1 Hz of the developed electrode was approximately 3.7 nV/√Hz. The reception of the underwater electric field signal using the developed electrode was linear, within an error of approximately 0.6 %, in the range of 1-10000 ㎶/m at 1 Hz. In addition, its frequency response was flat within an error of 1.1 % in the range of 1-1000 Hz at 10000 ㎶/m.

Preparation and Characterization of N-doped Na2Ti6O13@TiO2 Composites for Visible Light Activity (가시광 활성을 위한 N-doped Na2Ti6O13@TiO2 복합체 제조 및 특성 연구)

  • Duk-Hee, Lee;Kyung-Soo, Park
    • Journal of Powder Materials
    • /
    • v.29 no.6
    • /
    • pp.492-498
    • /
    • 2022
  • N-doped Na2Ti6O13@TiO2 (denoted as N-NTO@TiO2) composites are successfully synthesized using a simple two-step process: 1) ball-milling of TiO2 with Na2CO3 followed by heat treatment at 900℃; 2) mixing of the prepared Na2Ti6O13 with titanium isopropoxide and calcining with urea at 500℃. The prepared composites are characterized using XRD, SEM, TEM, FTIR, and BET. The N-NTO@TiO2 composites exhibit well-defined crystalline and anatase TiO2 with exposed {101} facets on the external surface. Moreover, dopant N atoms are uniformly distributed over a relatively large area in the lattice of the composites. Under visible light irradiation, ~51% of the aqueous methylene blue is photodegraded by N-NTO@TiO2 composites, which is higher than the values shown by other samples because of the coupling effects of the hybridization of NTO and TiO2, N-doping, and presence of anatase TiO2 with exposed {101} facets.

Evaluation of trueness and precision of removable partial denture metal frameworks manufactured with digital technology and different materials

  • Leonardo Ciocca;Mattia Maltauro;Elena Pierantozzi;Lorenzo Breschi;Angela Montanari;Laura Anderlucci;Roberto Meneghello
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.2
    • /
    • pp.55-62
    • /
    • 2023
  • PURPOSE. The aim of this study is to evaluate the accuracy of removable partial denture (RPD) frameworks produced using different digital protocols. MATERIALS AND METHODS. 80 frameworks for RPDs were produced using CAD-CAM technology and divided into four groups of twenty (n = 20): Group 1, Titanium frameworks manufactured by digital metal laser sintering (DMLS); Group 2, Co-Cr frameworks manufactured by DMLS; Group 3, Polyamide PA12 castable resin manufactured by multi-jet fusion (MJF); and Group 4, Metal (Co-Cr) casting by using lost-wax technique. After the digital acquisition, eight specific areas were selected in order to measure the Δ-error value at the intaglio surface of RPD. The minimum value required for point sampling density (0.4 mm) was derived from the sensitivity analysis. The obtained Δ-error mean value was used for comparisons: 1. between different manufacturing processes; 2. between different manufacturing techniques in the same area of interest (AOI); and 3. between different AOI of the same group. RESULTS. The Δ-error mean value of each group ranged between -0.002 (Ti) and 0.041 (Co-Cr) mm. The Pearson's Chi-squared test revealed significant differences considering all groups paired two by two, except for group 3 and 4. The multiple comparison test documented a significant difference for each AOI among group 1, 3, and 4. The multiple comparison test showed significant differences among almost all different AOIs of each group. CONCLUSION. All Δ-mean error values of all digital protocols for manufacturing RPD frameworks optimally fit within the clinical tolerance limit of trueness and precision.

Kinetic and Statistical Analysis of Adsorption and Photocatalysis on Sulfamethoxazole Degradation by UV/$TiO_2$/HAP System (UV/$TiO_2$/HAP 시스템에서 Sulfamethoxazole의 흡착과 광촉매반응에 대한 동역학적 및 통계적 해석)

  • Chun, Suk-Young;Chang, Soon-Woong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.5
    • /
    • pp.5-12
    • /
    • 2012
  • Antibiotics have been considered emerging compounds due to their continuous input and persistence in environment. Due to the limited biodegradability and widespread use of these antibiotics, an incomplete removal is attained in conventional wastewater treatment plants and relative large quantities are released into the environment. In this study, it was determined the adsorption and photocatalysis kinetics of antibiotics (Sulfamethoxazole, SMX) with various catalyst (Titanium dioxide; $TiO_2$, Hydroxyapatite; HAP) conditions under UV/$TiO_2$/HAP system. In addition, the statistical analysis of response surface methods (RSM) was used to determine the effects of operating parameters on UV/$TiO_2$/HAP system. $TiO_2$/HAP adsorbent were found to follow the pseudo second order reaction in the adsorption. In the result of applied intrapaticle diffusion model, the constants of reaction rate were $TiO_2$=$0.064min^{-1}$, HAP=$0.2866min^{-1}$ and $TiO_2$/HAP=$0.3708min^{-1}$, respectively.The result of RSM, term of regression analysis in analysis of variance (ANOVA) showed significantly p-value (p<0.05) and high coefficients for determination values($R^2$=96.2%, $R^2_{Adj}$=89.3%) that allowed satisfactory prediction of second order regression model. And the estimated optimal conditions for Y(Sulfamethoxazole removal efficiency, %) were $x_1$(initial concentration of Sulfamethoxazole)=-0.7828, $x_2$(amount of catalyst)=0.9974 and $x_3$(reation time)=0.5738 by coded parameters, respectively. According to the result of intraparticle diffusion model and photocatalysis experiments, it was shown that the $TiO_2$/HAP was more effective system than conventional AOPs(advanced oxidation processes, UV/$TiO_2$ system).

Influence of bearing surface angle of abutment screw on mechanical stability of joint in the conical seal design implant system (내부 원추형 연결형태 임플란트에서 지대주 나사머리의 좌면각도가 연결부 기계적 안정성에 미치는 영향)

  • Kim, Joo-Hyeun;Huh, Jung-Bo;Yun, Mi-Jung;Kang, Eun-Sook;Heo, Jae-Chan;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.206-214
    • /
    • 2014
  • This study is to evaluate how different bearing surface angles of abutment screw affect the mechanical stability of the joint in the conical seal design implant system. Materials and Methods: Internal connection type regular implants, two-piece cemented type abutments and tungsten carbide/carbon-coated titanium alloy abutment screws were selected. Titanium alloy screws with conical ($45^{\circ}$) and flat ($90^{\circ}$) head designs which fit on to abutment were fabricated. The abutments were tightened to implants with 30 Ncm by digital torque gauge. The loading was applied once to the central axis of abutment. The mean axial displacement was measured using micrometer before and after the tightening and loading (n = 5). The abutment was tightened to implants with 30 Ncm and T-shape stainless steel crown was cemented. Then the change in the amount of reverse-torque was measured after the repeated loading to the central axis, and the place 5 mm away from the central axis. Compressive bending and fatigue strength were measured at the place 5 mm away from the central axis (n = 5). Results: Both groups showed the largest axial displacement when abutment screw tightening and total displacement was greater in the flat head group compared to conical head group (P < 0.05). However, there were no significant differences in reverse torque value, compressive bending and fatigue strength (P > 0.05). Conclusion: Within the limitations of this study, the abutment screw head design had no effect on two groups regarding the joint stability, however the conical head design affected the settlement of abutment resulting in the reduced total displacement.