• Title/Summary/Keyword: time to cracking

Search Result 460, Processing Time 0.027 seconds

Mechanical and Thermal Analysis of Oxide Fuel Rods

  • Ilsoon Hwang;Lee, Byungho;Lee, Changkun
    • Nuclear Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.223-236
    • /
    • 1977
  • An integral computer code has been developed for a mechanical and thermal design and performance analysis of an oxide fuel rod in a pressurized water reactor. The code designated as FROD 1.0 takes into account the phenomena of radial power depression within the pellet, cracking, densification and swelling of the pellet, fission gas release, clad creep, pellet-clad contact, heat transfer to coolant and buildup of corrosion layers on the clad surface. The FROD 1.0 code yields two-dimensional temperature distributions, dimensional changes, stresses, and internal pressure of a fuel rod as a function of irradiation time within a reasonable computation time. The code may also be used for the analyses of oxide fuel rods in other thermal reactors. As an application of FROD 1.0 the behavior of fuel rod loaded in the first core of Go-ri Nuclear Power Plant Unit 1 is predicted for the two power histories corresponding to steady state operation and Codition II of the ANS Classification. The results are compared with the design criteria described in the Final Safety Analysis Report and a discrepancy between these two values is discussed herein.

  • PDF

A Study on the Measurement of Steel Corrosion in Mortar by TEM Method (TEM법에 의한 모르타르 중의 철근 부식 측정에 관한 연구)

  • Lee Sang-Ho;Han Jeong-Seb
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.2 s.69
    • /
    • pp.59-65
    • /
    • 2006
  • Steel, as a reinforcing mechanism in concrete, provides the tensile strength that is lacking in concrete, alone, and the high alkaline environment (pH 12.5) in concrete offers satisfactory protection against most corrosion of the steel. However, the corrosion of reinforcing steel in concrete can occur by chloride attack or carbonation, and it can cause a loss of integrity a section and concrete failure through cracking and spalling. In this study, a transient electro magnetic method (TEM) of a nondestructive technique is adapted to study the measuring method of steel corrosion in mortar. The sensor was made of an enameled wire, with a diameter of 0.25mm and anacril. He sensor configuration used was a coincident loop type. The secondary electro motive force (2nd EMF) was measured with SIROTEMIII, which equipped the accelerator. The accelerator allowsthe transmitter to turn off approximately $10\sim15$ times faster than normal. The high-resolution time series, used for very shallow or a high resistivity investigation was selected. After steels were corroded by the salt spray, during 4, 8, 15 and 25 days, they were embedded in mortar. The content results acquired in this study are as follows. The variation of the secondary electro motive force (2nd EMF) was shown by the change of steel surface with different corrosion time steel. It was confirmed that measurement of steel corrosion in mortar by a transient electro-magnetic method (TEM) can be possible.

The Skeletal Isomerization of 1-Pentene over Solid Acid Catalysts (고체산 촉매에서의 1-펜텐의 골격이성화반응)

  • Hong, Seong-Soo;Woo, Hee-Chul;Lee, Gun-Dae
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.902-912
    • /
    • 1996
  • In the skeletal isomerization of 1-pentene over various solid acid catalysts, we have studied catalytic reactivity, selectivity, reaction mechanism and the relation between acid strength of catalysts and catalytic activity. Natural zeolite shows highest activity among the all catalysts and the modified ${\eta}$-alumina with fluorine and sulfuric acid shows higher activity than unmodified ${\eta}$-alumina. The yield of isopentene increases with increasing temperature and increasing contact time. However the cracking products increase at the high temperature and very high contact time. In addition, the activity of natural zeolite exchanged with metal cation decreases and shows good relation with the polarizing power of metal cation. According to the result of ammonia TPD, the acid strength of catalysts has an effect on catalytic activity.

  • PDF

A New Garlic Cultivar 'Alkae' and Scape Removal Affects Bulb Growth (마늘 신품종 '올케' 특성 및 화경제거가 구 비대에 미치는 영향)

  • Cboi, Young-Hah;Kim, Hong-Lim;Kim, Heung-Deug;Kwak, Yong-Bum
    • Journal of Bio-Environment Control
    • /
    • v.20 no.1
    • /
    • pp.27-32
    • /
    • 2011
  • This study was carried out to investigate characteristics of new garlic cultivar 'Alkae' and to identify the effect of scape removal on bulb characteristics and growth of garlic cultivar 'Alkae' and 'Namdo'. Bolting time and harvesting time were earlier about 20 days in 'Alkae' than those in 'Namdo'. 'Alkae' was inferior to 'Namdo' in top growth as plant height, number of leaves, leaf area, SPAD value, diameter of leaf sheath, and so on. but root developing was better in 'Alkae'. Bulb weight of' Alkae' was 17% more than that of 'Namdo', harvested on proper time. The ratio of bulb weight over 40 g was almost double in 'Namdo' as 48% with 'Alkae' as 25%. Occurrence of bulb cracking was more considerable in 'Alkae' and the number of clove per bulb was 1.9 more in 'Alkae' than 'Namdo', but the ratio of bulb rot during storage was higher in 'Namdo' than 'Alkae'. In treatments of scape removal, SPAD value did not show any difference between two cultivars. Leaf dryness was earlier and harder than control and leaf area showed the same tendency as leaf dryness, and there were no significant differences among the methods of scape removal. The bulb weight and the ratio of bulb weight over 40 g at 50 days after the harvest of 'Alkae', 'Namdo' were more 10%, 12% and 27%, 44% in scape removal treatment than control. and there were no significant differences among the methods of scape removal. So, scape removal was very effective to increase large bulb production in the two garlic cultivals and the effect was higher in 'Namdo' than 'Alkae'. The ratio of bulb cracking and the occurrence of bulb rot were almost same in with the scape removal and non removal groups And also there were no significant differences among the methods of scape removal.

Adsorption Properties of Paint Mixed with Powdered Activated Carbon According to the Number of Coatings (분말활성탄을 혼합한 도료의 도장횟수에 따른 흡착 특성)

  • Choi, Byung-Cheol;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.25-26
    • /
    • 2021
  • Due to COVID-19, the spread of non-face-to-face culture is increasing the time spent indoors. Accordingly, it is necessary to reduce indoor air pollutants. Also, among building materials, there are paints. As the number of coatings increases, the coating film becomes thick, and there is a risk of cracking and falling off. Therefore, this study is to examine the adsorption properties of indoor air pollutants according to the number of coatings of a paint mixed with powdered activated carbon. In the experimental plan, the addition ratio of powdered activated carbon was selected as 30%, and the number of coatings was selected as primcoating, second coat, and finishing coat, and the concentration of formaldehyde and volatile organic compounds were measured. As a result, as the number of coatings increased, the concentration of formaldehyde and volatile organic compounds tended to decrease. This is considered to be due to the fact that not only the physical adsorption acted by the internal pores of the powdered activated carbon, but also because a lot of powdered activated carbon was present on the painted surface as the coating film was formed. However, since it is judged that there is an error in the concentration due to the inflow of external air as the chamber cover is opened to put the test object in the adsorption test process, it is considered that the experimental method needs to be supplemented.

  • PDF

Comparative Evaluation of Shielding Performance according to the Characteristics of Eco-friendly Shielding Material Tungsten (친환경 차폐재료 텅스텐 특성에 따른 차폐성능 평가)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.10
    • /
    • pp.129-136
    • /
    • 2021
  • Radiation shields used in medical institutions mainly use lead to manufacture products and fitments. Although lead has excellent processability and economic efficiency, its use is being reduced due to environmental issues when it is disposed of. In addition, when used for a long time, there is a limit to using it as a shielding film, shielding wall, medical device parts, etc. due to cracking and sagging due to gravity. To solve this problem, copper, tin, etc. are used, but tungsten is mostly used because there is a difficulty in the manufacturing process to control the shielding performance. However, it is difficult to compare with other shielding materials because the characteristics according to the type of tungsten are not well presented. Therefore, in this study, a medical radiation shielding sheet was manufactured in the same process using pure tungsten, tungsten carbide, and tungsten oxide, and the particle composition and shielding performance of the sheet cross-section were compared.As a result of comparison, it was found that the shielding performance was excellent in the order of pure tungsten, tungsten carbide, and tungsten oxide.

Finite Element Prediction of Temperature Distribution in a Solar Grain Dryer

  • Uluko, H.;Mailutha, J.T.;Kanali, C.L.;Shitanda, D.;Murase, H
    • Agricultural and Biosystems Engineering
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • A need exists to monitor and control the localized high temperatures often experienced in solar grain dryers, which result in grain cracking, reduced germination and loss of cooking quality. A verified finite element model would be a useful to monitor and control the drying process. This study examined the feasibility of the finite element method (FEM) to predict temperature distribution in solar grain dryers. To achieve this, an indirect solar grain dryer system was developed. It consisted of a solar collector, plenum and drying chambers, and an electric fan. The system was used to acquire the necessary input and output data for the finite element model. The input data comprised ambient and plenum chamber temperatures, prevailing wind velocities, thermal conductivities of air, grain and dryer wall, and node locations in the xy-plane. The outputs were temperature at the different nodes, and these were compared with measured values. The ${\pm}5%$ residual error interval employed in the analysis yielded an overall prediction performance level of 83.3% for temperature distribution in the dryer. Satisfactory prediction levels were also attained for the lateral (61.5-96.2%) and vertical (73.1-92.3%) directions of grain drying. These results demonstrate that it is feasible to use a two-dimensional (2-D) finite element model to predict temperature distribution in a grain solar dryer. Consequently, the method offers considerable advantage over experimental approaches as it reduces time requirements and the need for expensive measuring equipment, and it also yields relatively accurate results.

  • PDF

A numerical-experimental evaluation of beams composed of a steel frame with welded and conventional stirrups

  • Goncalves, Wagner L.;Gomes, Guilherme F.;Mendez, Yohan D.;Almeida, Fabricio A.;Santos, Valquiria C.;Cunha, Sebastiao S.Jr.
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.27-37
    • /
    • 2018
  • Reinforced concrete structures are widely used in civil engineering projects around the world in different designs. Due to the great evolution in computational equipment and numerical methods, structural analysis has become more and more reliable, and in turn more closely approximates reality. Thus among the many numerical methods used to carry out these types of analyses, the finite element method has been highlighted as an optimized tool option, combined with the non-linear and linear analysis techniques of structures. In this paper, the behavior of reinforced concrete beams was analyzed in two different configurations: i) with welding and ii) conventionally lashed stirrups using annealed wire. The structures were subjected to normal and tangential forces up to the limit of their bending resistance capacities to observe the cracking process and growth of the concrete structure. This study was undertaken to evaluate the effectiveness of welded wire fabric as shear reinforcement in concrete prismatic beams under static loading conditions. Experimental analysis was carried out in order compare the maximum load of both configurations, the experimental load-time profile applied in the first configuration was used to reproduce the same loading conditions in the numerical simulations. Thus, comparisons between the numerical and experimental results of the welded frame beam show that the proposed model can estimate the concrete strength and failure behavior accurately.

Crack Detection of Concrete Using Fiber Optic Cables (Fiber Optic Cable을 이용한 콘크리트 균열탐사)

  • Cho, Nam-So;Kim, Nam-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.157-163
    • /
    • 2007
  • Crack detection technique for concrete structures has been developed in this study. Experimental tests were carried out to detect a surface and internal crack, employing common fiber optic cables and OTDR(optical time domain reflectometry), an optical signal analyzer which is widely used to detect damages at fiber optic cables in the field of optical engineering. While initial concrete crack is ready to occur under cracking force, the occurrence and location of the crack are simultaneously detected to give the same damage to fiber optic cables which have been attached to and/or embedded into concrete in advance. It is obtained through successive tests that the principal factors for crack detection is the covering state of fiber optic cable, and total 4 tests including a preliminary test were conducted and the crack detection technique was verified. The practical usefulness would be expected at crack management and maintenance of concrete structures.

Link-E-Param : A URL Parameter Encryption Technique for Improving Web Application Security (Link-E-Param : 웹 애플리케이션 보안 강화를 위한 URL 파라미터 암호화 기법)

  • Lim, Deok-Byung;Park, Jun-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.9B
    • /
    • pp.1073-1081
    • /
    • 2011
  • An URL parameter can hold some information that is confidential or vulnerable to illegitimate tampering. We propose Link-E-Param(Link with Encrypted Parameters) to protect the whole URL parameter names as well as their values. Unlike other techniques concealing only some of the URL parameters, it will successfully discourage attacks based on URL analysis to steal secret information on the Web sites. We implement Link-E-Param in the form of a servlet filter to be deployed on any Java Web server by simply copying a jar file and setting a few configuration values. Thus it can be used for any existing Web application without modifying the application. It also supports numerous encryption algorithms to choose from. Experiments show that our implementation induces only 2~3% increase in user response time due to encryption and decryption, which is deemed acceptable.