• 제목/요약/키워드: time to $V_{max}$

검색결과 128건 처리시간 0.159초

Maximum Oxygen Consumption Determined by the Bruce and Inclined Treadmill Protocols

  • Kim, Kyu-Hwa;Kim, Hyeong-Jin;Kim, Kyoung-Soon
    • The Korean Journal of Physiology
    • /
    • 제27권2호
    • /
    • pp.209-215
    • /
    • 1993
  • The aim of the present study was to derive regression equations for $\dot{V}o_{2max}\;vs.\;\dot{V}o_{2peak},\;and\;\dot{V}o_2\;vs.$ heart rate, exercise time, and other variables from maximal exercise tests on a treadmill using the Bruce and inclined protocols. Twelve male and 10 female Korean college students aged between 19 and 23 years voIunteered for this study. After the resting measurements, the subjects performed a maximal exercise on a treadmill according to the Bruce protocol. When the resting conditions were restored, the subjects performed another maximal exercise according to an inclined protocol where the speed was fixed at 8.05 $km{\cdot}h^{-1}$ and the grade was incremented starting from 09t by 2.5% for every 2 min. Peak $\dot{V}o_2$ observed during the Bruce exercise $(\dot{V}o_{2peak})$ was $37.7{\pm}2.4\;and\;31.7{\pm}1.8\;ml\;kg^{-1}\;min^{-1}$ in the male and female groups, respectively. Peak $\dot{V}o_2$ observed during the inclined exercise was higher than $\dot{V}o_{2peak}$ during the Bruce exercise. Maximum $\dot{V}o_2$ value observed during the tyro exercises $(\dot{V}o_{2max})$ was $43.0{\pm}2.8\;and\;36.2{\pm}1.4\;ml\;kg^{-1}\;min^{-1}$ in the male and female groups, respectively. Thus, $\dot{V}o_{2peak}$ by the Bruce protocol was about 12% (male) or 13% (female) lower than $\dot{V}o_{2max}$, and a linear relationship was found between $\dot{V}o_{2peak}$ and $\dot{V}o_{2max}$. The peak values of % $\dot{V}o_{max}$ with the Bruce protocol were $89.2{\pm}3.3\;and\;87.5{\pm}3.6%$ and those with the inclined protocol $97.7{\pm}1.8\;and\;96.9{\pm}2.0%$ in the male and female groups, respectively. In the female group, $%\dot{V}o_{2max}$ at a given workload was higher than in the male group, while $\dot{V}o_{2}$ per kg body weight was the same. Maximum HR observed during the two exercises was $204{\pm}2\;and\;195{\pm}3\;beat\;min^{-1}$ in the male and female groups, respectively. Linear relationships were found, excluding the last points, between 1) $\dot{V}o_{2}$ and exercise time, 2) $\dot{V}o_{2}$ and $%\dot{V}o_{2max}\;and\;%HR_{max}$.

  • PDF

Facility Location Problem for Blood Logistics Center (혈액 물류센터 위치 선정 문제)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • 제12권2호
    • /
    • pp.135-143
    • /
    • 2012
  • This paper suggests the optimal blood distribution center algorithm that satisfies the minimum total transportation cost and within the allowable distribution time $T^*$. Zhang and Yang proposes shifting the location of each point that has less than the average distance of two maximum distance points from each point. But they cannot decide the correct facility location because they miscompute the shortest distance. This algorithm computes the shortest distance $l_{ij}$ from one area to another areas. Then we select the $v_i$ area to thecandidate distribution center location such that $_{max}l_{ij}{\leq}L^*$ and the $v_i$ such that $l_{ij}-L^*$ area that locates in ($v_i,v_k$) and ($v_j,v_l$) from $P_{ij}=v_i,v_k,{\cdots},v_l,v_j$ path and satisfies the $_{max}l_{ij}{\leq}L^*$ condition. Finally, we decide the candidate distribution area that has minimum transportation cost to optimal distribution area.

Analysis of Endotoxin Using Analytical Conditions of Optical Density in Metalworking Fluid Sample (금속가공유 시료에서 일부 Optical Density 설정값에 따른 엔도톡신의 정량)

  • Park, Dong-Uk;Han, In-Young;Yoon, Chung-Sik;Park, Doo-Yong
    • Analytical Science and Technology
    • /
    • 제15권5호
    • /
    • pp.459-465
    • /
    • 2002
  • This study was performed to identify the proper analytical conditions of endotoxins regarding optical density in the workplace where metalworking fluids are used. This study found that "onset time method" was more accurate than "time to $V_{max}$ method". Reproducibility and accuracy analyzed by "onset time method" was greatly higher than the "time to $V_{max}$". The optical density of "0.03" was the most appropriate analytical condition among "onset time method". In this analytical condition, linearity of 0.998 was obtained and recovery rate ranged from 88% to 105% at the endotoxin concentrations below 5 EU/mL. No significant difference of endotoxins was observed between the optical densities of "0.03" and "0.05". However, correlation coefficients were different with statistical significance (p<0.01). This study confirmed that either the optical densities "0.03" or "0.05" should be used to analyze endotoxin. Of these optical density values, OD with correlation coefficient higher than 0.98 should be used to analyze endotoxin in environmental samples.

Aerobic Capacity and Ventilatory Response During Incremental Exercise in Elite High School Cyclist (점진부하 운동에서 중고교 엘리트 사이클 선수들의 유산소능력과 폐환기 반응)

  • Lee, Dae-Taek;Bae, Yoon-Jung
    • Journal of Life Science
    • /
    • 제20권3호
    • /
    • pp.437-443
    • /
    • 2010
  • This study was designed to examine the aerobic capacity and ventilatory response during an incremental exercise in elite high school cyclists. Twelve boys ($17{\pm}1\;yr$, $175{\pm}5\;cm$, $70{\pm}9\;kg$) participated in anthropometric measurements, incremental exercise testing, and pulmonary function tests. During incremental exercise testing using a cycle ergometer, their maximal oxygen uptake ($VO_2max$), maximal power output, ventilation, ventilatory equivalents for oxygen ($V_E/VO_2$) and carbon dioxide ($V_E/VCO_2$), respiratory rate, and tidal volume were measured. Time variables such as inspiratory time (Ti), expiratory time (Te), breathing time (Tb), and inspiratory duty cycle (Ti/Tb), as well as inspiratory flow rate ($V_T$/Ti) were assessed. Pulmonary function of vital capacity (FVC), forced expiratory volume in one second ($FEV_1$), $FEV_1$/FVC, and peak expiratory flow were evaluated. Their $VO_2max$, maximal heart rate, and Wmax were $57.5{\pm}3.9\;ml{\cdot}kg^{-1}{\cdot}min^{-1}$, $194.1{\pm}8.6\;beat{\cdot}min^{-1}$, and 452 W, respectively. $VO_2max$ was not related to any anthropometric parameters. Most ventilatory variables progressively increased with exercise intensity. As intensity increased, Ti, Tb, Tb decreased while Ti/Tb was maintained. Below an intensity of 250 W, height, weight, body mass index, and body surface were highly correlated with $V_T$/Ti and Ti/Tb (p<0.05). Collectively, $VO_2max$ appeared to be lower than adult cyclists, suggesting a different pattern of ventilatory control as age advances. Morphological characteristics were not related to $VO_2max$ in the population. Time variables of ventilatory response seemed to be related only at an exercise intensity level of less than 250 W. $V_T$/Ti may be related to exercise endurance capacity, but Ti/Tb was similar to adult cyclists.

Respiratory Gas Exchange and Ventilatory Functions at Maximal Exercise (최대운동시의 호흡성 가스교환 및 환기기능)

  • Cho, Yong-Keun;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권6호
    • /
    • pp.900-912
    • /
    • 1995
  • Background: Although graded exercise stress tests are widely used for the evaluation of cardiorespiratory performance, normal standards on respiratory gas exchange and ventilatory functions at maximal exercise in Koreans have not been well established. The purpose of this study is to provide reference values on these by sex and age, along with derivation of some of their prediction equations. Method: Symptom-limited maximal exercise test was carried out by Bruce protocol in 1,000 healthy adults consisting of 603 males and 397 females, aged 20~66 years. Among them VC, $FEV_1$ and MVV were also determined in 885 cases. All the subjects were members of a health center, excluding athletes. During the exercise, subjects were allowed to hold on to front hand rail of the treadmill for safety purpose. Results: The $VO_2\;max/m^2$, $VCO_2\;max/m^2$ and $V_E\;max/m^2$ were greater in males than in females and decreased with age. The RR max in men and women was similar but decreased slightly with age. The $V_T$ max was markedly greater in men but showed no significant changes with age in either gender. The mean of $V_T$ max/VC, $V_E$ max/MVV and BR revealed that there were considerable ventilatory reserves at maximal exercise even in older females. The regression equations of the cardinal parameters obtained using exercise time(ET, min), age(A, yr), height(Ht, cm), weight(W, kg), sex(S, 0=male; 1=female), VC(L), $FEV_1$(L) and $V_E$ max(L) as variables are as follows: $VO_2\;max/m^2$(L/min)=1.449+0.073 ET-0.007A+0.010W-0.006Ht-0.209S, $VCO_2\;max/m^2$(L/min)=1.672+0.063ET-0.008A+0.010W-0.005Ht-0.319S, VE max/$m^2$(L/min)=58.161+1.503ET-0.315A-9.871S or VE max/$m^2$(L/min)=47.873+6.548 $FEV_1$-5.715 S, and VT max(L)=1.497+0.223VC-0.493S. Conclusion: Respiratory gas exchange and ventilatory variables at maximal exercise were studied in 1,000 non-athletes by Bruce protocol. During exercise, the subjects were allowed to hold on to hand rail of the treadmill for safety purpose. We feel that our results would provide ideal target values for patients and healthy individuals to be achieved, since our study subjects were members of a health center whose physical fitness levels were presumably higher than ordinary population.

  • PDF

The Arcing Faults Simulation and Adaptive Autoreclosure Strategy for 765 kV Transmission Line Protection (765 kV 송전선로 보호를 위한 아크사고 시뮬레이션 및 적응적 자동재폐로 대책)

  • Ahn, Sang-Pil;Kim, Chull-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • 제48권11호
    • /
    • pp.1365-1373
    • /
    • 1999
  • In many countries including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for EHV/UHV transmission lines to ensure requirements for high reliability of main lines. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. Therefore the accurate simulation techniques of arcing faults are of importance. And successful reclosing switching can be accomplished by adopting a proper method such as HSGS and hybrid scheme to reduce the secondary arc extinction time. First of all, this paper discusses a suggested arc model, which have time dependent resistance for primary arc and piecewise linear approximated arc model for secondary arc. And this simulation technique is applied to Korean 765 kV transmission lines. Also hybrid scheme is simulated and evaluated for the purpose of shortening dead time. For adaptive reclosing scheme, variable dead time control algorithm is suggested. Two kinds of algorithm are tested. One is max tracking algorithm and the other is rms tracking algorithm. According to simulation results, rms tracking has less errors than max tracking. Therefore rms tracking is applied to Korean 765 kV transmission lines with hybrid scheme.

  • PDF

MAX-MIN CONTROLLABILITY OF DELAY-DIFFERENTIAL GAMES IN HILBERT SPACES

  • Kang, Yong-Han;Jeong, Jin-Mun;Park, Jong-Yeoul
    • Journal of the Korean Mathematical Society
    • /
    • 제38권1호
    • /
    • pp.177-191
    • /
    • 2001
  • We consider a linear differential game described by the delay-differential equation in a Hilbert space H; (※Equations, See Full-text) U and V are Hilbert spaces, and B(t) and C(t) are families of bounded operators on U and V to H, respectively. A(sub)0 generates an analytic semigroup T(t) = e(sup)tA(sub)0 in H. The control variables g, and u and v are supposed to be restricted in the norm bounded sets (※Equations, See Full-text). For given x(sup)0 ∈ H and a given time t > 0, we study $\xi$-approximate controllability to determine x($.$) for a given g and v($.$) such that the corresponding solution x(t) satisfies ∥x(t) - x(sup)0∥ $\leq$ $\xi$($\xi$ > 0 : a given error).

  • PDF

Effects of Fructose-containing Drinks on Cardiopulmonary Function, Lactate Levels, and Inflammatory Markers during Maximal Exercise Testing (과당음료 투여가 최대운동부하시 운동수행력, 심폐기능, 젖산 및 염증반응에 미치는 영향)

  • Park, Sung-Mo;Kim, Byung-Woo;Kwak, Yi-Sub
    • Journal of Life Science
    • /
    • 제25권7호
    • /
    • pp.819-825
    • /
    • 2015
  • The use of fructose-containing sports beverage drinks has increased in recent years, especially at sport events, because of their reported ergogenic effects. However, the ingestion of low to moderate doses of caffeinated energy drinks has been associated with adverse side effects such as insomnia or increased nervousness. The purpose of this study was to investigate the effects of fructose beverage supplementation on cardiopulmonary function, blood lactate levels, and inflammatory reactions. We recruited 8 young adult subjects from D university and measured their cardiopulmonary functions before and after supplementation with sports beverage drinks. We also measured blood lactate and inflammatory reactions after a 20 min recovery period. Exercise time, maximal oxygen uptake (V02max), and AT HRmax were significantly increased (p<0.05) in the period of before and after sports beverage supplementation. However, no significant differences were observed in RPE, AT RER, V02max RER, AT V02max, and maximum heart rate (HRmax). Lactate levels also significantly decreased after 20 min recovery with sports beverage supplementation. Sports beverage supplementation therefore may enhance maximal V02max and increase the exercise duration time. These drinks may also be helpful in promoting rapid recovery of fatigue variables and increasing exercise performance time.

Bioequivalence Assessment of Acephyll® Capsule to Surfolase® Capsule (Acebrophylline HCl 100 mg) by Liquid Chromatography Tandem Mass Spectrometry

  • Nam, Kyung-Don;Seo, Ji-Hyung;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • 제41권5호
    • /
    • pp.309-315
    • /
    • 2011
  • A sensitive and specific liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the analysis of ambroxol (active moiety of acebrophylline). After acetonitrile precipitation of proteins from plasma samples, ambroxol and the domperidone (internal standard, IS) were eluted on a C18 column. The isocratic mobile phase was consisted of 10 mM ammonium acetate and methanol (10 : 90, v/v), with flow rate at 0.2 mL/min. A tandem mass spectrometer, as detector, was used for quantitative analysis in positive mode by a multiple reaction monitoring mode to monitor the m/z 379.2${\rightarrow}$264.0 and the m/z 426.2${\rightarrow}$175.1 transitions for ambroxol and the IS, respectively. Twenty four healthy Korean male subjects received two capsules (100 mg ${\times}$ 2) of either the test or the reference formulation of acebrophylline HCl in a 2 ${\times}$ 2 crossover study, this was followed by a 1week washout period between either formulation. $AUC_{0-t}$ (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. The 90% confidence intervals for the log transformed data were acceptable range of log 0.8 to log 1.25 (e.g., log 0.8964 - log 0.9910 for $AUC_{0-t}$ log 0.8690 - log 1.0750 for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of Korea Food and Drug Administration for bioequivalence indicating that Acephyll$^{(R)}$ capsule (test) is bioequivalent to Surfolase$^{(R)}$ capsule (reference).

Effects of High-Energy Ball Milling and Sintering Time on the Electric-Field-Induced Strain Properties of Lead-Free BNT-Based Ceramic Composites

  • Nga-Linh Vu;Nga-Linh Vu;Dae-Jun Heo;Thi Hinh Dinh;Chang Won Ahn;Chang Won Ahn;Hyoung-Su Han;Jae-Shin Lee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제36권5호
    • /
    • pp.505-512
    • /
    • 2023
  • This study investigated crystal structures, microstructures, and electric-field-induced strain (EFIS) properties of Bi-based lead-free ferroelectric/relaxor composites. Bi1/2Na0.82K0.18)1/2TiO3 (BNKT) as a ferroelectric material and 0.78Bi1/2(Na0.78K0.22)1/2TiO3-0.02LaFeO3 (BNKT2LF) as a relaxor material were synthesized using a conventional solid-state reaction method, and the resulting BNKT2LF powders were subjected to high-energy ball milling (HEBM) after calcination. As a result, HEBM proved a larger average grain size of sintered samples compared to conventional ball milling (CBM). In addition, the increased sintering time led to grain growth. Furthermore, HEBM treatment and sintering time demonstrated a significant effect on EFIS of BNKT/BNKT2LF composites. At 6 kV/mm, 0.35% of the maximum strain (Smax) was observed in the HEBM sample sintered for 12 h. The unipolar strain curves of CBM samples were almost linear, indicating almost no phase transitions, while HEBM samples displayed phase transitions at 5~6 kV/mm for all sintering time levels, showing the highest Smax/Emax value of 700 pm/V. These results indicated that HEBM treatment with a long sintering time might significantly enhance the electromechanical strain properties of BNT-based ceramics.