• 제목/요약/키워드: tightening torque

검색결과 92건 처리시간 0.027초

345kV 송전선로용 자동클램핑 장치형 스페이서 댐퍼 개발 (A development of the 345kV spacer damper with automatic clamping device for transmission line)

  • 안용호;이동일;김태진;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.278-282
    • /
    • 2001
  • The purpose of this study is to introduce a new spacer damper for the bundle transmission lines network. It has the special design, the main characteristics and advantage of this new kind of spacer damper. An Existing spacer damper with bolted clamps, although widely used, is a method of connection with certain disadvantage both as regards assembly on the conductor and in the course of time. Even if tightening torque is correctly applied by using bolt with share head or torque wrench during working time, the aeolian vibration could involve untightening during life time, so the cable can move into the Jaws and wire's breakage appear. To salve this problems, France, Japan and other countries had developed a spacer damper with an automatic system through many years. This new spacer damper is an original automatic clamping device (beltless) which does not require special tool for its installation. This device prevents clamp unlocking problems, ensures a simple installation and ensures a reliable-tightening during life time. Therefore, it is necessary to localize this boltless spacer damper with automate clamping device.

  • PDF

기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교 (Comparison of removal torque between prefabricated and customized abutment screw)

  • ;김지환;김무성;박영범;심준성
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.243-248
    • /
    • 2012
  • 연구 목적: 본 연구의 목적은 임플란트 지대주 연결에 사용되는 기성품 나사와 맞춤형 나사의 풀림 토크를 비교하는 것이다. 연구 재료 및 방법: 세가지 임플란트 시스템에(Osstem, Astra, Zimmer) 대해 고정체와 지대주의 연결에 기성품 나사군(대조군)과 맞춤형 나사군(실험군)으로 총 6군(n = 6)으로 나누었다. 조임 토크조절은 디지털 토크 측정기를 이용하였으며 각 임플란트 제조사가 추천한 조임 토크 값을 적용하였다. 체결 10분 후 동일한 조임 토크를 다시 적용하고 5분 후에 풀림 토크력을 측정하였다. 이 과정을 10회 반복 측정하였다. 반복 하중 실험에서는 6개 군(n = 3)에 대해 체결 10분 후 2차 조임 토크를 적용하고 $30^{\circ}$ 경사로 50 N 하중으로 총 1,000,000번 반복 하중을 가하였다. 반복 하중 적용 이후 풀림 토크값을 측정하였다. 통계 방법으로는 10회 반복 측정에서 풀림 토크값의 차이를 비교하기 위해 repeated measures of ANOVA test (${\alpha}$=.05)를 사용하였고, 반복 하중 후 풀림 토크값의 차이를 비교하기 위해서 각 시스템별 Independant t-test로 통계 처리하였다. 결과: 모든 군에서 반복 횟수가 증가할수록 풀림 토크값이 유의성 있게 감소하는 것으로 나타났다(P<.05). 10회 반복 측정 실험에서는 세 종류의 임플란트에서 대조군(기성품나사)과 실험군(맞춤형 나사) 간에 풀림 토크값은 유의차가 없었다(P>.05). 반복 하중 실험에서 세가지 시스템에서 대조군과 실험군 간의 풀림 토크력은 유의한 차이가 없었다(P>.05). 결론: 반복 측정된 풀림력 검사와 반복 하중을 적용 후 풀림력 검사에서 맞춤형 나사와 기성품 나사의 풀림력은 유의한 차이가 없었다.

A Study on the Nylon Wire Holding and Release Mechanism for Cube Satellites by Applying Constant Holding

  • Koo, KeonWoo
    • 항공우주시스템공학회지
    • /
    • 제15권4호
    • /
    • pp.1-6
    • /
    • 2021
  • The non-explosive holding and release mechanism is used to prevent damage to the mission component caused by explosives when the deployment structure for Cube Satellites is separated. However, among the several types available, the non-explosive holding and release mechanism system using nylon wires depend on the nylon wire knot method and tightening power of the worker. Therefore, in this study, we conducted experiments with the operation of a new holding and release mechanism system by conceptualizing the Boa System Dial, which can provide a constant tightening force regardless of worker proficiency and deploying a imitational solar panel. In this study, the process of binding and unbinding with constant tension was recorded while applying the novel non-explosive holding and release mechanism using the Boa System Dial proposed. In addition, required advances are indicated for the application of the proposed system to actual Cube Satellites.

볼트 결합부 풀림에 관한 마찰 특성 (제 I 보 : 나사 마찰 실험) (The Friction Properties on the Loosening of Bolted Joints (I: Thread Friction Experiments))

  • 박태원;신귀수
    • 한국안전학회지
    • /
    • 제18권2호
    • /
    • pp.1-5
    • /
    • 2003
  • By using an approach developed to determine the torque-tension relationship for bolted joints, frictional properties of several typical bolted joints were studied experimentally. The specific property by bolted joints certify that the most significant influence of materials and bearing surface condition. Experiments on thread friction shows that prevailing torque nuts with distorted threads provide benefit for preventing self-loosening of the nut. Repeated tightening-loosening generally increases frictions in a bolted joint. It was noted that the data scatter of the experimental results of frictions in a belted joint may overshadow the influence of size. speed, and contact positions. The results from the experimental investigation will help to better design bolted joints.

A Study of mechanical properties of oxide layer removed Co-Cr-Mo abutments

  • Ryu, Jae-ho;Huh, Jung-Bo;Ro, Jung-Hoon;Yun, Mi-Jung;Jeong, Chang-Mo
    • 대한치과의사협회지
    • /
    • 제53권11호
    • /
    • pp.804-816
    • /
    • 2015
  • PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O; oxide layer formed, CCM-B; blasted, CCM-P; polished after blasted) and gold abutment (Gold-C; Cast with type III Gold alloy) were used. The initial settling values of abutments were evaluated according to the difference of implant-abutment length when the tightening torques were applied at 5 Ncm and 30 Ncm, and the settling values of abutments caused by loading were evaluated according to the difference of implant-abutment length before and after loading with 250 N, 100000 cycle. The loss ratios of removal torque for abutment screws were evaluated according to the difference in value of removal torques under 30 Ncm tightening torque applied before and after cyclic loading. RESULTS: The CCM-P and CCM-B group showed a higher initial settling value compared with the Gold-C group (P<.05), while the Gold-C group showed the highest settling values caused by loading (P<.05) and no significant differences were observed for between CCM groups (P>.05). The loss ratio of removal torque values for the CCM-B, CCM-P groups did not differ significantly from that of the Gold-C group (P>.05). CONCLUSION: Even though the oxide layer was removed by different methods, CCM abutment with internal conical connection structure showed lower abutment settling and similar screw loosening after cyclic loading compared with gold abutment.

임플랜트의 체결방식에 따른 초기조임력에 의한 응력분포 및 전하중에 관한 연구 (THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND PRELOAD OF DIFFERENT CONNECTION TYPES IMPLANT WITH INITIAL CLAMPING)

  • 이범현;전흥재;이수홍;한종현
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.197-206
    • /
    • 2006
  • Statement of problem: One of common problems associated with single teeth dental implant prosthetic is the loosening of screws that retain the implants. Purpose: The maintenance of screw joint stability is considered a function of the preload achieved in the screw when the suggested initial tightening torque is applied. The purpose of this study was to investigate acquired preload after initial clamping torque for estimating screw joint stability. Material and methods: A comparative study on the effect of initial clamping of two types of implant systems with different connections was conducted Three dimensional non-linear finite element analysis is adopted to compare the characteristics of screw preloads and stress distributions between two different types of implant systems composed with abutment, screw, and fixture under the same loading and boundary conditions. Results: 1. When the initial clamping torque of 32Ncm was applied to the implant systems, all types of implants generated the maximum effective stress at the first helix region of screw. 2. Morse taper connection types of implants generate lower stress distributions compared to those by butt joint connection types or implants due to large contact surface between abutment and fixture. 3. The internal types of implant systems with friction grip type implant systems have higher resistance to screw loosening than that of the external types of implant systems since the internal types of implant systems generated larger preload than that generated by the external types for the same tightening moments.

Titanium Implant의 Removal Torque에 관한 연구 (A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS)

  • 이준석;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제32권1호
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

토크전단형 고력볼트의 토크계수 변동에 따른 체결축력 확보방안에 관한 연구 (A Study on the Secure Plan of Clamping Force according to the Variation of Torque-Coefficient in Torque-Shear High Strength Bolts)

  • 이현주;나환선;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제5권3호
    • /
    • pp.8-16
    • /
    • 2014
  • Torque control method and turn of nut method are specified as clamping method of high strength bolts in the steel construction specifications. Quality control of torque coefficient is essential activity because torque control method, which is presently adopted as clamping method in domestic construction sites, is affected by variation of torque coefficient. The clamping of torque shear bolt is based on KS B 2819. It was misunderstood that the tension force of the TS bolt was induced generally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the intended tension, as it considerably varies due to torque coefficient dependent on the environmental factors and temperature variables despite the break of the pin tail.This study was focused to evaluate the effect of environmental factors and errors of installing bolts during tightening high strength bolts. The environmental parameters were composed of 'wet' condition, 'rust' condition, 'only exposure to air' condition. And the manufacture of trial product was planned to identify the induced force into the bolts. The algorithm for a trial product was composed of the relation between electricity energy taken from torque shear wrench and tension force from hydraulic tension meter.

전동렌치 전기에너지를 이용한 토크쉬어볼트의 체결축력 검사기법 개발 (Development of the Method for Inspecting the Clamping Force of Torque Shear Bolts Using the Electricity energy of Electric torque wrench)

  • 이현주;나환선;김강식;김강석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권6호
    • /
    • pp.162-170
    • /
    • 2010
  • 토크쉬어볼트의 토크계수는 환경요인에 의해 영향을 받는다. 습기, 녹, 시공중의 작업성 등. 토크쉬어볼트의 토크계수의 변동에 기인하여 볼트에 도입된 축력을 예측하는 매우 어렵다. 이런 이유로 시공중인 볼트 축력을 측정하고, 체결력을 검증하는 것은 필수적이다. 이 연구에서, 볼트에 도입된 하중을 확인하기 위해 시작품 제작이 계획되었다. 시작품의 알고리즘은 토크쉬어 전동렌치에서 얻은 전기에너지와 유압축력기에서 얻은 축력과의 상관관계를 구성한 것이다. 직접축력을 계측하는 회귀분석식은 미니탭 프로그램을 이용한 통계학적인 분석방법에서 구한 것이다. 이 시작품은 상용 토크렌치에 견줄만한 인장력을 평가하는 신뢰성이 있는 도구라고 판단된다.

내구 열화에 따른 샤시계 볼트 체결력 변화 인자 연구 (A Study of Bolt Tightening Changing Factor according to Durability Degradation)

  • 최동영;최재칠;한종욱
    • 자동차안전학회지
    • /
    • 제7권1호
    • /
    • pp.20-26
    • /
    • 2015
  • In vehicle development process, durability test should be carried out in field condition. Nowadays there are many customer live there multiple conditions. It makes change of the car's material. Such change causes to lose a bolt. Diversifications of climatic conditions are also a matter of loosening the bolt. To avoid this problem, to identify the cause of the problem, and the solution should be applied. To avoid problems during the durability development test should be measured by the clamping force. Ultrasonic instruments clamping force without affecting the torque can be measured. This instrument is part of the problem by monitoring the clamping force required to obtain objective data.