THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND PRELOAD OF DIFFERENT CONNECTION TYPES IMPLANT WITH INITIAL CLAMPING

임플랜트의 체결방식에 따른 초기조임력에 의한 응력분포 및 전하중에 관한 연구

  • Lee Bum-Hyun (Dept. of Mechanical engineering, College of Engineering, Yonsei University) ;
  • Chun Heoung-Jae (Dept. of Mechanical engineering, Graduate School, Yonsei University) ;
  • Lee Soo-Hong (Dept. of Mechanical engineering, Graduate School, Yonsei University) ;
  • Han Chong-Hyun (Dept. of Prosthodontics, College of Dentistry, Yonsei University(Youngdong Severance Hospital))
  • 이범현 (연세대학교 공과대학 기계공학과 대학원) ;
  • 전흥재 (연세대학교 공과대학 기계공학부) ;
  • 이수홍 (연세대학교 공과대학 기계공학부) ;
  • 한종현 (연세대학교 치과대학 보철학교실)
  • Published : 2006.04.01

Abstract

Statement of problem: One of common problems associated with single teeth dental implant prosthetic is the loosening of screws that retain the implants. Purpose: The maintenance of screw joint stability is considered a function of the preload achieved in the screw when the suggested initial tightening torque is applied. The purpose of this study was to investigate acquired preload after initial clamping torque for estimating screw joint stability. Material and methods: A comparative study on the effect of initial clamping of two types of implant systems with different connections was conducted Three dimensional non-linear finite element analysis is adopted to compare the characteristics of screw preloads and stress distributions between two different types of implant systems composed with abutment, screw, and fixture under the same loading and boundary conditions. Results: 1. When the initial clamping torque of 32Ncm was applied to the implant systems, all types of implants generated the maximum effective stress at the first helix region of screw. 2. Morse taper connection types of implants generate lower stress distributions compared to those by butt joint connection types or implants due to large contact surface between abutment and fixture. 3. The internal types of implant systems with friction grip type implant systems have higher resistance to screw loosening than that of the external types of implant systems since the internal types of implant systems generated larger preload than that generated by the external types for the same tightening moments.

Keywords

References

  1. Albrektsson T, Zarb G , Worthington P, Eriksson AR. The long term efficiency of currently used dental implants: A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986: 1: 11-25
  2. Kallus T, Bressing C, Odont D. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994:9:169-178
  3. Holmes DC, William RG. Vijay KG, John CK. Comparison of Stress Transmission in the IMZ Implant System with Polyoxymethylene or Titanium Intranmobile Element : A Finite Element Stress Analysis. Int J Oral Maxillofac Implants 1992:7:450-458
  4. Ekfeldt A. Carlsson GE, B rjesson G. Clinical Evaluation of single-tooth restorations supported by osseointegrated implants: A retrospective study. Int J Oral Maxillofac Implants 1994:9:179-18
  5. Jorneus L. Loads and design of screw joint for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992:7:353-359
  6. Beaty K. Binon P. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994: 9 :48-99
  7. McGlumphy EA. Keeping implant screws tight: The solution. Dental Symposia 1993: 1: 20-23
  8. Lisa A. Lang, Rui-Feng Wang, Kenneth B. May. The influence of abutment screw tightening on screw joint configuration. J Prosth Dent 2002:87:74-79 https://doi.org/10.1067/mpr.2002.121488
  9. Lisa A. Lang, Byungsik Kang, Rui-Feng Wang, Brien R. Lang. Finite element analysis to determine implant preload. J Prosth Dent 2003:60:6:539-546
  10. Ronald L. Sakaguchi, Svenn E. Borgersen. Nonlinear Finite Element Contact Analysis of Dental Implant Components. The international Journal of Oral & Maxillofacial Implants 1993:8:6:655-661
  11. Antheunis Versluis, Tom W. P. Korioth, Antonio C. Cardoso. Numerical Analysis of a Dental Implant System Preloaded with a Washer. Int J Oral Maxillofac Implants 1999:14:3:337-341
  12. Bear R. Merz , Dr sc techn. Stephan Hunenbart. Urs C. Belser. Mechanics of the Implant-Abutment Connection : An 8-Degree Taper Compared to a Butt Joint connection. Int J Oral Maxillofac Implants 2000: 15:519-526
  13. Sakaguchi RL. Borgersen SE. Nonlinear contact analysis of preload in dental implant screw. Int J Oral Maxillofac Implant 1995: 10: 295-302
  14. Richard L. Burguete. MEng. Richard B. Johns. Toby King. Eann A. Patterson. Tightening characteristics for screwed joints in osseointegrated dental implants. J prosthetic Dent 1994: 71: 6: 592-599 https://doi.org/10.1016/0022-3913(94)90443-X