References
- Adell R, Eriksson B, Lekholm U, Br?nemark P, Jemt T. A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;5:347-59.
- Adell R, Lekholm U, Rockler B, Br?nemark P. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416. https://doi.org/10.1016/S0300-9785(81)80077-4
- Henry PJ, Laney WR, Jmet T, Harris D, Krogh PHJ, Polizzi G, Zarb GA, Hewwmann I. Osseointegrated implants for single-tooth replacement: A prospective 5-year multicenter styudy. Int J Oral Maxillofac Implants 1996;11:450-55.
- Lekholm U, Grondahl K, Jmet T. Outcome of oral implant treatment in partially edentulous jaws followed 20 years in clinical function. Clin Oral Implants Res 2006;8:178-86.
- Jömeus L, Jmet T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-59.
- Kim KS, Lim YJ, Kim MJ, Kwon HB, Yang JH, Lee JB, Yim SH. Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection. Clin Oral Implants Res 2011;22:834-39. https://doi.org/10.1111/j.1600-0501.2010.02063.x
- Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: A critical review. Int J Oral Maxillofac Implants 2003;18:719-28.
- Lewis S, Beumer J, Moy P. The "UCLA" abutment. Int J Oral Maxillofac Implants 1988;3:183-89.
- Barbosa G, Simamoto Junior P, Fernandes neto A, Mattos M, Neves F. Prosthetic laboratory influence on the vertical misfit at the implant/UCLA abutment interface. Braz Dent J 2007;18(2): 139-43. https://doi.org/10.1590/S0103-64402007000200010
- Binon P, Mchuge M. The effect of elinimating implant/abutment rotational misfit on screw joint stability. Int J Prosthodont 1996;9:511-19.
- Duncan A, Labeed H, Abel L, Kamali A, Watts F. Effects of thermal treatments on protein adsorption of Co-Cr-Mo ASTM- F75 alloys. J Master Sci;Master Med 2011;22:1455-464. https://doi.org/10.1007/s10856-011-4324-5
- Caicedo S, Desai R, McAllister K, Reddy A, Jacobs J, Hallab J. Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: A novel mechanism for implant debris reactivity. J Orthop Res 2009;27:847-54. https://doi.org/10.1002/jor.20826
- Proussaefs P, Lozada J. Evaluation of two Vitallium blade- form implants retrieved after 13 to 21 years of function: A clinical report. J Prosthet Dent 2002;87:412-17. https://doi.org/10.1067/mpr.2002.122960
- Teigen K, Jokstad A. Dental implant suprastructures using cobalt-chromium alloy compared with gold alloy framework veneered with ceramic or acrylic resin : a retrospective cohort study up to 18 years. Clin Oral Implant Res 2012;23:853-60. https://doi.org/10.1111/j.1600-0501.2011.02211.x
- Kenneth J. Philllips' science of dental materials. 11th ed. Charm yun. Co., 2003, korean Ver., p. 336-7, p. 575-6.
- Stüker RA, Teixeira ER, Beck JC, da Costa NP. Preload and torque removal evaluation of three different abutment screw for single standing implant restoration. J Appl Oral Sci 2008;16(1): 55-8. https://doi.org/10.1590/S1678-77572008000100011
- Shin HM, Jung CM, Jeon YC, Yun MJ, Yoon JH. Influence of tightening torque on implant-abutment screw joint stability. J Korean Acad Prosthodont 2008;46:396-408.