• Title/Summary/Keyword: tibia length

Search Result 121, Processing Time 0.029 seconds

Effect of Stem Design on Contact Pressure and Stress Distribution of End-of-stem in Revision TKR (슬관절 재전치환술용 경골 삽입물 형상이 주대 말단부의 접촉압력과 응력 분포에 미치는 영향)

  • Kim, Yoon-Hyuk;Kwon, Oh-Soo;Park, Si-Mon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.11 s.188
    • /
    • pp.126-134
    • /
    • 2006
  • In this study, the effect of stem-end design on contact pressure and stress distribution in revision TKR was investigated using finite element method. The finite element model of tibia, including the cortical bone, the cancellous bone and canal, was developed based on CT images. The implant models with various stem lengths, diameters, friction coefficients, and press-fit effects were considered. The results showed that the longer stem length, the stronger press-fit, the bigger stem diameter, and the higher friction coefficient increased both peak contact pressure and Von-Mises stress distributions. The results supported the clinical hypothesis that peak contact pressure and stress are related to the stem end pain. The results of this study will be useful to design the stem and reduce the end-of-stem pain in revision TKR.

Electron-Morphometric Classification of the Native Honeybees from Korea. Part II. Discriminant Analysis for Different Populations Based on the Total Characters (한국산 재래꿀벌의 전자계량형태학적 분류. II. 전 47형질에 대한 각 지역개체군간 판정분석)

  • 권용정;허은엽
    • Korean journal of applied entomology
    • /
    • v.32 no.1
    • /
    • pp.30-41
    • /
    • 1993
  • In the present investigation, some multivariate discriminant analyses were done for each population of the native honeybee workers (Apis cerana), which were selected for 15 different localities in spring and 16 in summer form Korea. when the comparison of both seasons for different populations and regardless of seasons were conducted, all the classification results revealed that the differences were significantly prominent. And the length of fore tibia(FTL) was the best contributed character among the 47 morphometric characters used in the analysis.

  • PDF

The Effect of Mechanical Dynamization on Regenerative Bone Healing (기계적 역동화가 골절치유에 미치는 영향)

  • 이문규;최귀원;최인호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.158-161
    • /
    • 2002
  • We investigated whether controlled dynamization enhanced regenerative bone healing of the tibia in 12 adult mongrel dogs. An average of 2 cm (∼ 10% of bone length) lengthening was obtained. The left hindlimb was allowed dynamization of 1 mm, 2 mm, and 3 mm in magnitude when 1 cm (∼ 5%) of lengthening was achieved, whereas the right hindlimb was not dynamized and served as a control. Bone mineral density (BMD) of the regenerative bone was measured periodically until nine weeks after the end of distraction. After sacrifice, uniaxial compression testing was performed. Relative BMD ratio and

  • PDF

Polymeria with an Extra Hindlimb at the Pelvic Region, Occured in Korean Native Calf (한우 송아지의 후지에 발생한 과다사지)

  • 한동운
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.423-426
    • /
    • 2003
  • Congenital anomalies occur at low levels in Korean antive cattle. PCR and Serum neutrlizing test against BVD, Akabane virus, Ibaraki virus, Kasba virus were examined. The results were all negative. Gross anatomical analysis was carried aout. Congenital abnormal newborn calf had 2 atropic left hindlimbs, which was nor moved autonomosly. The length of 2 atropic hindlimbs was 72 em and 48cm respectively. Both of them were curved severely at joints. Affected limbs were developed in connective tissue but lack of muscular tissue. In the abdominal region right kidney was normal. But there were two left kidneys which was half size compared with normal kidney. One of them had polycysts. In skeletal region, affected left limb is defective of head of femur and tibia.

WETTABILITY AND DRUG DELIVERY OF FUNCTIONALLY GRADED NANO-MICRO POROUS TITANIUM SURFACE

  • Yun, Kwi-Dug;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.307-319
    • /
    • 2008
  • STATEMENT OF PROBLEM: It is known that an anodic oxidation technique, one of the methods for the implant surface treatment, remarkably increased surface area, enhanced wettability and accelerated the initial bone healing. Purpose: This study was performed to evaluate the wettability of anodized titanium surface which has a nanotubular structure, to assess osseointegration after the placement of implant with nano-size tubes on tibia of rats and to analyze quantitatively transferable rhBMP-2 on each surface. MATERIAL AND METHOD: Four different kinds of surface-treated titanium discs (polished (machined surface) group, micro (blasting surface) group, nano (anodizedmachined surface) group, and nano-micro (anodized-blasting surface) group) were fabricated (n=10). Three different media were chosen to measure the surface contact angles; distilled water, plasma and rhBMP-2 solution. After a single drop (0.025 $m{\ell}$) of solution, the picture was taken with the image camera, and contact angle was measured by using image analysis system. For the test of osseointegration, 2 kinds of anodized surface (anodized-machined surface, anodized-blasting surface) implants having 2.0 mm in diameter and 5.0 mm in length inserted into the tibia of Wistar rats. After 3 weeks, tibia were harvested and the specimens were stained with hematoxylin and eosin for histological analysis. To test the possibility of drug delivery, after soaking sample groups in the concentration of 250 ng/$m{\ell}$l of rhBMP-2 for 48 hours, the excess solution of rhBMP-2 were removed. After that, they were lyophilized for 24 hours, and then the rhBMP-2 on the surface of titanium was resolved for 72 hours in PBS. All the extracted solution was analyzed by ELISA. One-way analysis of variance (ANOVA) was performed on the data. RESULTS: The wettability is improved by anodic oxidation. The best wettability was shown on the nano-micro group, and it was followed by nano group, micro group, and polished group. In the histological findings, all implants showed good healing and the new bone formation were observed along the implant surface. After 3 days, nano-micro group delivered the most amount of rhBMP-2, followed by nano group, micro group, and polished group. CONCLUSION: It indicated that anodic oxidation on blasting surface produce functionally graded nano-micro porous structure and enhance hydrophilicity of the surface and osseointegration. The findings suggest that the nano-micro porous structure could be a useful carrier of osteogenic molecules like rhBMP-2.

Reconstruction of Tibial Defects in Lower Extremity With Various Versions of Vascularized Fibula Transfer (다양한 형태의 생 비골 이식술을 이용한 경골의 재건)

  • Nam, Sang-Hyun;Kim, Bom-Jin;Koh, Sung-Hoon;Chung, Yoon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.15 no.1
    • /
    • pp.17-25
    • /
    • 2006
  • Twelve cases in eleven patients with segmental bone defects were treated with contralateral fibula free flap and ipsilateral island fibula flap in an antegrade, retrograde or bidirectional flow fashion. Five cases were managed with free flaps and seven were with ipsilateral fibula island transfer. Among seven cases, antegrade fashion was three, retrograde was three, and bidirectional was one. All patients were related with open tibial fractures and its sequelae except one who had open foot bone fracture. According to Gustilo's classification, ten patients were type IIIb and one was type IIIc. Basically, antegrade-flow flaps based on the peroneal vessels as in the conventional free flap were used for the proximal or middle one-third tibial defects. On the contrary, retrograde-flow flaps based on the communicating branch between the peroneal and posterior tibial vessels were used for the middle or distal one-third of the tibia. Bidirection-flow flap based on intact peroneal vessels were used for the middle portion of the tibia. The patients who have undergone ipsilateral fibula island flap had one of the following problems: a previously failed free flap, below-knee amputation of the opposite leg because of open tibial fracture, refusal to use the contralateral sound leg, or poor general condition to stand a lengthy operation. Six of the patients who have got ipsilateral fibula island flap also had an associated fibula fracture on the same leg, which was ultimately used as one of the osteotomy sites. The follow-up period was from 1 to 10 years. Two cases of free flap were failed: one patient had below-knee amputation and the other patient had ipsilateral fibula transfer. Other cases were successful and excellent hypertophy of the transferred fibula was achieved. Time to bone union ranged from 4 to 11 months. Time to full weight bearing was from 5 to 13 months after surgery. All of the transferred fibulas showed hypertrophy after weight bearing. In one case, stress fracture was developed during ambulation, which was healed conservatively. Nonunion occurred in two cases, which were treated with a long leg cast and cancellous bone graft, respectively. Length discrepancy of the legs was noted. The limb was shorter by an average 0.5 cm in three cases, longer by 1.1 cm in one case. In the case of island fibula transfer, limited arc of rotation was not a problem. Other disabling complications were not seen. We believe that these diverse modalities using a vascularized fibula will make us more comfortable to handle major bone defects.

  • PDF

The effects of saline soaking on the removal torque of titanium implants in rabbit tibia after 10 days (0.9% 식염수 담금이 레이저 처리 임플란트의 초기 치유기간의 회전 제거력에 미치는 영향)

  • Park, Jung-Hyun;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.328-334
    • /
    • 2019
  • Purpose: The aim of this study was to confirm if Laser-treated implants were soaked in 0.9% NaCl solution for 2 weeks could increase the surface hydrophilicity, and the Remoal Torque of each implant that inserted in rabbit tibia for initial healing period of 10 days. Materials and methods: Twenty machined titanium surface screws were produced with a diameter 3 mm, length 8 mm. Ten screws had their surface treated with a laser only (laser treated group), and the other 10 were soaked in saline for 2 weeks after surface treatment with a laser (laser treated + saline soaked group). Implants were inserted in rabbit tibia (ten adult New Zealand white rabbits), and the RTQ of each implant was measured after 10 days. The wettability among implants was compared by measuring the contact angle. Surface composition and surface topography were analyzed. Results: After 10 days, the laser treat + soaking group implants had a significantly higher mean RTQ than the laser treated implants (P = .002, < .05). There were no significant morphological differences between groups, and no remarkable differences were found between the two groups in the SEM analysis. Conclusion: Saline soaking implants is expected to produce excellent RTQ and surface analysis results.

Age quadratically affects intestinal calcium and phosphorus transporter gene expression in broiler chickens

  • Lv, Xianliang;Hao, Junfang;Wu, Lihua;Liu, Mengyuan;He, Lei;Qiao, Yingying;Cui, Yanyan;Wang, Guan;Zhang, Chunmei;Qu, Hongxia;Han, Jincheng
    • Animal Bioscience
    • /
    • v.35 no.12
    • /
    • pp.1921-1928
    • /
    • 2022
  • Objective: This research aimed to evaluate the effects of age on growth, tibia development, and intestinal calcium (Ca) and phosphorus (P) transporter gene expressions in broiler chickens. Methods: A total of 224 male Arbor Acres broilers were fed with nutrient-adequate diets and reared in eight cages (28 broilers per cage). Eight broilers (one broiler per cage) were selected and killed at 5, 10, 15, 20, 25, 30, 35, and 40 days of age, respectively. Results: Body weight continuously increased with age of broiler chickens from 5 to 40 days. The bone weight, ash weight, diameter, and length of the tibia also increased with broiler age. By contrast, the tibia ash, Ca, and P percentages quadratically changed with age (p<0.001), and the highest values of mineral contents were observed at 20, 25, and 25 days of age, respectively. The mRNA abundances of calcium-binding protein 28-kDa (CaBP-D28k), sodium-calcium exchanger 1 (NCX1), and plasma membrane ATPase 1b (PMCA1b) increased from 5 to 25 days and then decreased up to 40 days. Similar results were noted in the mRNA abundances of IIb sodium-phosphate cotransporter (NaPi-IIb), inorganic phosphate transporter 1 (PiT-1), inorganic phosphate transporter 2 (PiT-2), nuclear vitamin D receptor (nVDR), and membrane vitamin D receptor (mVDR). The mRNA abundances of Ca and P transporters and VDRs were the highest at 25 days of age. Conclusion: These data indicate that age quadratically affects intestinal Ca and P transporter gene expression and mineral absorption capacity in broiler chickens.

Effect on bone healing by the application of low intensity pulsed ultrasound after injection of adipose tissue-derived stem cells at the implantation of titanium implant in the tibia of diabetes-induced rat (당뇨유도 백서 경골에 티타늄 임플란트 매식 시 지방조직 유래 줄기세포 주입 후 저출력 초음파 적용이 골치유에 미치는 영향)

  • Jung, Tae-Young;Park, Sang-Jun;Hwang, Dae-Suk;Kim, Yong-Deok;Lee, Soo-Woon;Kim, Uk-Kyu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.4
    • /
    • pp.301-311
    • /
    • 2011
  • Introduction: This study examined the effect of the application of low intensity pulsed ultrasound on bone healing after an injection of adipose tissue-derived stem cells (ADSCs) during the implantation of a titanium implant in the tibia of diabetes-induced rats. Materials and Methods: Twelve Sprague-Dawely rats were used. After inducing diabetes, the ADSCs were injected into the hole for the implant. Customized screw type implants, 2.0 mm in diameter and 3.5 mm in length, were implanted in both the tibia of the diabetes-induced rats. After implantation, LIPUS was applied with parameters of 3 MHz, 40 mW/$cm^2$, and 10 minutes for 7 days to the left tibiae (experimental group) of the diabetesinduced rats. The right tibiae in each rat were used in the control group. At 1, 2 and 4 week rats were sacrificed, and the bone tissues of both tibia were harvested. The bone tissues of the three rats in each week were used for bone-to-implant contact (BIC) and bone area (BA) analyses and the bone tissues of one rat were used to make sagittal serial sections. Results: In histomorphometric analyses, the BIC in the experimental and control group were respectively, $39.00{\pm}18.17%$ and $42.87{\pm}9.27%$ at 1 week, $43.74{\pm}6.83%$ and $32.27{\pm}6.00%$ at 2 weeks, and $32.62{\pm}11.02%$ and $47.10{\pm}9.77%$ at 4 weeks. The BA in experimental and control group were respectively, $37.28{\pm}3.68%$ and $31.90{\pm}2.84%$ at 1 week, $20.62{\pm}2.47%$ and $15.64{\pm}2.69%$ at 2 weeks, and $11.37{\pm}4.54%$ and $17.69{\pm}8.77%$ at 4 weeks. In immunohistochemistry analyses, Osteoprotegerin expression was strong at 1 and 2 weeks in the experimental group than the control group. Receptor activator of nuclear factor kB ligand expression showed similar staining at each week in the experimental and control group. Conclusion: These results suggest that the application of low intensity pulsed ultrasound after an injection of adipose tissue-derived stem cells during the implantation of titanium implants in the tibia of diabetes-induced rats provided some positive effect on bone regeneration at the early stage after implantation. On the other hand, this method is unable to increase the level of osseointegration and bone regeneration of the implant in an uncontrolled diabetic patient.

Removal Torque and Histomorphometric Investigation of Surface Modified Commercial Implants: An Experimental Study in the Rabbit Tibia (상용화된 치과용 임플란트의 뒤틀림 제거력 및 조직학적 분석 연구: 가토 경골에서의 연구)

  • Park, Jong-Hyun;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.41-56
    • /
    • 2008
  • The methods of surface modification of commercial implants were various according to the manufacturer. Surface modification of implant may produce diverse physical and chemical surface characteristics resulted from the treatment method and treatment condition. As a result, the bone response might be different. Even though surface modified implants have been used clinically, most researches are focusing on the bone response of surface modified implants comparing to machined implants rather than surface modified commercial implants. This study compare and analyze bone responses of 4 surface modified commercial implants with different shapes and surfaces. Eighty surface modified commercial implants with 4 different surface characteristics were installed in the tibia of white Newzealand rabbits. Biomechanical stability tests and histomorphometric evaluation were done. The results were as follows: 1. Surface modified commercial implants showed stable osseointegration at 6 weeks after installation. 2. Histomorphometric evaluation showed that there was no significant differences in bone to implant contact among 4 different commercial titanium implants. In comparing the implants with different shape the measurement of bone growth in subcortical area would be more reliable than entire bone to implant contact length. 3. Resonance Frequency Analysis showed that there was no significant differences among 4 types of implants, even though they were significantly different in installation. 4. There was significant differences in interfacial shear strength among 4 type of implants. 5. It is difficult to observe accurate bone to implant interface using Micro-CT. However, it is possible to measure the entire contact length of the implant to the bone.