• 제목/요약/키워드: three-dimensional sound

Search Result 146, Processing Time 0.025 seconds

A Study on the Interactive acoustic Method of 3D(Three-dimensional)signage Image Contents on Multipurpose stage (공간상의 입체사이니지 영상 콘텐츠 연동형 음향연출기법 연구)

  • Park, Cheon-Il;Yang, Seungyoun;Cha, Jae-Sang
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.107-113
    • /
    • 2017
  • Recently, digital signage is various changes and converging media. It is common to exhibit and guide focusing on information transfer by using the display. Such a method can not express variously changing digital signage. Therefore, we have to find a way to solve the problem of place and structure. In this paper, we experimented the new direction technique. Finally, we are going to propose acoustic direction technique using a microphone to maximize digital signage and intention of delivery by adding an sound reinforcement method to the visual representation.

Double-layered reconstruction of the nasal floor in complete cleft deformity of the primary palate using superfluous lip tissue

  • Park, Young-Wook;Kwon, Kwang-Jun;Kim, Min-Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.35.1-35.7
    • /
    • 2015
  • After cleft lip repair, many patients suffer from nasolabial fistulas, asymmetrical nasal floor, or an indistinct nostril sill, as well as intraoral wound dehiscence and subsequent scar contracture of surgical wounds leading to vestibular stenosis. For successful primary nasolabial repair of complete cleft deformity of the primary palate, cleft surgeons need special care in reconstructing the sound nasal floor. Especially when the cleft gap is wide or when any type of nasoalveolar molding therapy was not performed, three-dimensional reconstruction of the nasal floor is critical for a balanced nasal shape. In this study, the author describes an effective method for reconstructing a double-layered nasal floor using two mucosal flaps from both sides of the fissured upper lip. This is a report of six patients with unilateral or bilateral complete cleft of the primary palate with a detailed description of the surgical technique and a literature review.

Development of the Backward Tracing Scheme of FEM and Its Application to Initial Blank Design in Sheet Metal Forming (유한요소법을 이용한 역추적기법 개발 및 판재성형의 초기블랭크 형상설계에 적용)

  • 최한호;강경주;구태완;임학진;황상문;강범수
    • Transactions of Materials Processing
    • /
    • v.9 no.4
    • /
    • pp.348-355
    • /
    • 2000
  • The backward tracing scheme(BWT) of the finite element method has been extended lot the design of sheet blank in three-dimensional deformation. Originally the scheme was developed for preform design in bulk forming, and applied to several forming processes successfully. Its key concept is to trace backward from the final desirable configuration to an intermediate preform or initial blocker. A program for initial blank design in sheet forming which contains the capabilities of forward loading simulation by the finite element method and backward tracing simulation, has been developed and proved the effectiveness by applying to a square cup stamping process. In the blank design of square cup stamping, the backward tracing program can produce an optimum blank configuration which forms a sound net-shape cup product without machining after forming. For the confirmation of the analytic result derived from the backward tracing simulations as well as forward loading simulations, a series of experiment were carried out. The experiments include the first trial sheet forming process with a rectangular blank, an improved process with a modified blank preform and the final process with an optimum blank resulted from the backward tracing scheme. The experiments show that the backward tracing scheme has been implemented successfully in blank design of sheet metal forming.

  • PDF

Integrity Evaluation of Deep Foundations by Using Impact Echo Method(Numerical Study) (충격반향기법을 이용한 깊은 기초의 건전도 평가(수치해석))

  • 김동수;박연홍
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.2
    • /
    • pp.139-152
    • /
    • 1999
  • These days we broadly apply drilled shafts for deep foundations to build infrastructures. The defects of the deep foundations cause the decrease of their support load capacity and the increase of settlement, and the subsequent damage of the super-structures. In consequence, non-destructive testings techniques of concrete piles are important for their integrity evaluation. To improve understanding and reliable application of the impact echo method for the integrity evaluation of the drilled concrete piles, numerical studies of the impact response of concrete piles by using axi-symmetric three-dimensional finite element method are peformed for (a) sound piles: (b) piles containing necks, voids and layers of low-quality concrete: and (c) piles in soil and/or above rock. The results of these studies show that the finite element method is effective for evaluating the impact response of drilled concrete piles.

  • PDF

Particle image velocimetry measurement of complex flow structures in the diffuser and spherical casing of a reactor coolant pump

  • Zhang, Yongchao;Yang, Minguan;Ni, Dan;Zhang, Ning;Gao, Bo
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.368-378
    • /
    • 2018
  • Understanding of turbulent flow in the reactor coolant pump (RCP) is a premise of the optimal design of the RCP. Flow structures in the RCP, in view of the specially devised spherical casing, are more complicated than those associated with conventional pumps. Hitherto, knowledge of the flow characteristics of the RCP has been far from sufficient. Research into the nonintrusive measurement of the internal flow of the RCP has rarely been reported. In the present study, flow measurement using particle image velocimetry is implemented to reveal flow features of the RCP model. Velocity and vorticity distributions in the diffuser and spherical casing are obtained. The results illuminate the complexity of the flows in the RCP. Near the lower end of the discharge nozzle, three-dimensional swirling flows and flow separation are evident. In the diffuser, the imparity of the velocity profile with respect to different axial cross sections is verified, and the velocity increases gradually from the shroud to the hub. In the casing, velocity distribution is nonuniform over the circumferential direction. Vortices shed consistently from the diffuser blade trailing edge. The experimental results lend sound support for the optimal design of the RCP and provide validation of relevant numerical algorithms.

Electrical Transmission Line Modelling of the Cochlear Basilar Membrane (다팽이관 기저막의 전기 전달선 모델링)

  • Jarng, Soon-Suck
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.125-136
    • /
    • 1993
  • The study of Cochlear biomechanics is to clearly define three biomechanical principles of the Cochlea : Activity, Nonlinearity and Feedback. In this article, the Cochlea is linearly and actively modelled in one dimensional time domain. The sharp tunning of the Basilar Membrane displacement is shown when the amplifying activity of hair cells is added to the model. The amplified energy of the travelling displacement wave is emitted throughout the Cochlear fluid, so that the model becomes unstable. A new technique is introduced to reduce strong echos fro the Helicotrema. It makes the model less unstable. Both pure and click tones are used as input stimuli onto the ear durm. When the model is normal, the click response of the model shows that the backward emission of the amplified fluid pressure has mainly the echos from the Helicotrema. However, when the linear and active model is assumed to be abnormal, that is, some of hair cells are damaged not to produce the active process, the effect of the hair cell damage is resulted in the Oto-acoustic emission. The frequency response of the abnormally emitted sound pressure shows that the Oto-acoustic emission has the information about the characteristic frequency of the damaged hair cell. The main aim of this paper is to demonstrate the active biomechanics of the Chchlea in the time domain.

  • PDF

A Feasibility Study of Wood-plastic Composite Paver Block for Basic Rest Areas

  • Yang, Sungchul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.51-65
    • /
    • 2019
  • A wood-plastic composite (WPC) paver block was manufactured using wood chips waste through an extrusion process, and it was intended to be used for paving in basic rest areas. The first stage in this study covered preliminary tests in terms of flexural strength and dimensional swelling to determine the optimal WPC compounding mix condition, by variation of the WPC ingredients. Next, three different paver blocks including the WPC block, a non-porous cement block, and a porous cement block were tested in terms of various material properties in the laboratory. Finally, two outdoor test sections of the proposed paver blocks were prepared to simulate a basic rest area. Test results indicated that the flexural strength of the WPC paver blocks was about 1.6 times greater than that of the tested cement paver blocks. The WPC block pavement was unaffected by water buoyance as well as volume expansion due to swelling. Results from the impact absorbance test and light falling weight deflectometer (LFWD) test clearly showed that the WPC block paving system marginally satisfied the comfortable and safe hardness range from the pedestrians' perspective, while the results demonstrated that it is structurally sound for application as a road paving block.

Effective Cu Filling Method to TSV for 3-dimensional Si Chip Stacking (3차원 Si칩 실장을 위한 효과적인 Cu 충전 방법)

  • Hong, Sung Chul;Jung, Do Hyun;Jung, Jae Pil;Kim, Wonjoong
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.2
    • /
    • pp.152-158
    • /
    • 2012
  • The effect of current waveform on Cu filling into TSV (through-silicon via) and the bottom-up ratio of Cu were investigated for three dimensional (3D) Si chip stacking. The TSV was prepared on an Si wafer by DRIE (deep reactive ion etching); and its diameter and depth were 30 and $60{\mu}m$, respectively. $SiO_2$, Ti and Au layers were coated as functional layers on the via wall. The current waveform was varied like a pulse, PPR (periodic pulse reverse) and 3-step PPR. As experimental results, the bottom-up ratio by the pulsed current decreased with increasing current density, and showed a value of 0.38 on average. The bottom-up ratio by the PPR current showed a value of 1.4 at a current density of $-5.85mA/cm^2$, and a value of 0.91 on average. The bottom-up ratio by the 3-step PPR current increased from 1.73 to 5.88 with time. The Cu filling by the 3-step PPR demonstrated a typical bottom-up filling, and gave a sound filling in a short time.

Micro Vibration Measurement in a Latex Sample Mimicking the Tympanic Membrane Using Micro Vibro Tomography (고막을 모방한 라텍스 샘플의 미세진동 측정을 위한 마이크로 바이브로 토모그라피 시스템 개발)

  • Kwon, Jaehwan;Kim, Pilun;Jeon, Mansik;Kim, Jeehyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.1
    • /
    • pp.23-27
    • /
    • 2019
  • In this paper, we propose a micro vibro tomography(MVT) method, that can be used to visualize two-dimensional cross-sectional images and micro-vibration tomographic images in real time in a non-contact and non-destructive manner. The proposed method is based on the optical coherence tomography(OCT) technique, with an additionally customized image processing algorithm. The proposed method can detect the micro-motions or vibrations in sample structures by measuring the phase shift variations in the sample structures. In this study, we show the potential capabilities of the proposed MVT system for measuring the micro-vibrations generated when sound waves in a frequency range of 2~5 kHz are applied to an $80-{\mu}m$ thick latex phantom, which mimics the changes in physical structure of the human tympanic membrane while hearing. Additionally, three-dimensional volumetric images of the MVT method were recorded to observe the surface morphological changes in the surface of the phantom sample which mimics the human tympanic membrane while hearing.

Comparison of the sound source localization methods appropriate for a compact microphone array (소형 마이크로폰 배열에 적용 가능한 음원 위치 추정법 비교)

  • Jung, In-Jee;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.1
    • /
    • pp.47-56
    • /
    • 2020
  • The sound source localization technique has various application fields in the era of internet-of-things, for which the probe size becomes critical. The localization methods using the acoustic intensity vector has an advantage of downsizing the layout of the array owing to a small finite-difference error for the short distance between adjacent microphones. In this paper, the acoustic intensity vector and the Time Difference of Arrival (TDoA) method are compared in the viewpoint of the localization error in the far-field. The comparison is made according to the change of spacing between adjacent microphones of the three-dimensional microphone array arranged in a tetrahedral shape. An additional test is conducted in the reverberant field by varying the reverberation time to verify the effectiveness of the methods applied to the actual environments. For estimating the TDoA, the Generalized Cross Correlation-Phase transform (GCC-PHAT) algorithm is adopted in the computation. It is found that the mean localization error of the acoustic intensimetry is 2.9° and that of the GCC-PHAT is 7.3° for T60 = 0.4 s, while the error increases as 9.9°, 13.0° for T60 = 1.0 s, respectively. The data supports that a compact array employing the acoustic intensimetry can localize of the sound source in the actual environment with the moderate reflection conditions.