Electrical Transmission Line Modelling of the Cochlear Basilar Membrane

다팽이관 기저막의 전기 전달선 모델링

  • 장순석 (조선대공과대학, 제어계측공학과)
  • Published : 1993.06.01

Abstract

The study of Cochlear biomechanics is to clearly define three biomechanical principles of the Cochlea : Activity, Nonlinearity and Feedback. In this article, the Cochlea is linearly and actively modelled in one dimensional time domain. The sharp tunning of the Basilar Membrane displacement is shown when the amplifying activity of hair cells is added to the model. The amplified energy of the travelling displacement wave is emitted throughout the Cochlear fluid, so that the model becomes unstable. A new technique is introduced to reduce strong echos fro the Helicotrema. It makes the model less unstable. Both pure and click tones are used as input stimuli onto the ear durm. When the model is normal, the click response of the model shows that the backward emission of the amplified fluid pressure has mainly the echos from the Helicotrema. However, when the linear and active model is assumed to be abnormal, that is, some of hair cells are damaged not to produce the active process, the effect of the hair cell damage is resulted in the Oto-acoustic emission. The frequency response of the abnormally emitted sound pressure shows that the Oto-acoustic emission has the information about the characteristic frequency of the damaged hair cell. The main aim of this paper is to demonstrate the active biomechanics of the Chchlea in the time domain.

Keywords