• Title/Summary/Keyword: three phase transformer

Search Result 224, Processing Time 0.031 seconds

Three-Phase Interleaved Isolated High Efficiency Boost Converter (인터리브 방식 삼상 절연형 고효율 부스트 컨버터)

  • Choi, Jung-Wan;Cha, Han-Ju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.496-503
    • /
    • 2009
  • In this paper, a new three-phase interleaved isolated high efficiency boost dc-dc converter with active clamp is proposed. The converter is capable of increased power transfer due to its three-phase power configuration, and it reduces the rms current per phase, thus reducing conduction losses. Further, interleaved operation of three-phase boost converter reduces overall ripple current, which is imposed into fuel cells and realizes smaller sized filter components, increasing effective operating frequency and leading to higher power density. Each output current of three-phase boost converter is combined by the three-phase transformer and flows in the continuous conduction mode by the proposed three-phase PWM strategy. An efficiency of above 96% is mainly achieved by reducing conduction losses and switching losses are reduced by the action of active clamp branches, as well. The proposed converter and three-phase PWM strategy are analyzed, simulated and implemented in hardware. Experimental results are obtained on a 500 W prototype unit, with all of the design verified and analyzed.

Controlled Switching Method to Limit the Inrush Current for Unloaded Transformer (투입전류 제한을 위한 무부하 변압기의 개폐제어방식)

  • Lee, W.Y.;Park, K.Y.;Chong, J.K.;Kim, H.J.;Park, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.744-746
    • /
    • 2002
  • In this paper the method to limit inrush currents for unloaded transformers is proposed by controlling the opening instant in order to predetermine the residual flux. For the purpose of verifying the performance of the proposed method the test circuit with a single phase transformer is established and the effect of the controlled method is studied. With the basis of the obtained results the controlled method for three phase transformers with a wye-delta winding is also proposed. The analysis studies using EMTP(Electro-Magnetic Transient Program) are carried out in order to reveal its effectiveness.

  • PDF

Operating Characteristics in LCLC Resonant Converter with A Low Coupling Transformer. (낮은 커플링 변압기를 갖는 LCLC 공진컨버터 동작특성)

  • Kong Young-Su;Kim Eun-Soo;Lee Hyun-Kwan;Cho Jung-Goo;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.7
    • /
    • pp.343-350
    • /
    • 2005
  • Conventionally, for transferring the primary power to the secondary one, the high frequency series resonant converter has been widely used for the contactless power supply system. However, the high frequency series resonant converter has the disadvantages such as the low efficiency, the high voltage gain characteristics and deviation of the phase angle in the overall load range. To improve this disadvantages, In this paper, the characteristics of the high efficiency and unit voltage gain as well as in-phase are revealed in the proposed three-level LCLC (Inductor-Capacitor- Inductor-Capacitor) resonant converter. The results are verified on the simulation based on the theoretical analysis and the 4kW experimental Prototype.

Control of a Single Phase Unified Power Quality Conditioner-Distributed Generation Based Input Output feedback Linearization

  • Mokhtarpour, A.;Shayanfar, H.A.;Bathaee, M.;Banaei, M.R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1352-1364
    • /
    • 2013
  • This paper describes a novel structure for single phase Unified Power Quality Conditioner-Distributed Generation (UPQC-DG) with direct grid connected DC-AC converter for low DC output DG systems which can be used not only for compensation of power quality problems but also for supplying of load power partly. This converter has been composed of one full-bridge inverter, one three winding high frequency transformer with galvanic isolation and two cycloconverters. Proper control based on Input Output feedback Linearization is used to tracking the reference signals. The simulation and experimental results are presented to confirm the validity of the proposed approach.

Characteristics of the SFCL by turn-ratio of three-phase transformer

  • Jeong, I.S.;Choi, H.S.;Jung, B.I.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.34-38
    • /
    • 2013
  • According to the increase of electric consumption nowadays, power system becomes complicated. Due to this, the size of single line-to-ground fault from power system also increases to have many problems. In order to resolve these problems effectively, an Superconducting Fault Current Limiter(SFCL) was proposed and continuous study has been done. In this paper, an SFCL was combined to the neutral line of a transformer. An superconductivity has the characteristics of zero resistance below critical temperature. because of this, SFCL has nearly zero resistance. so we connecting SFCL to neutral line will not only have any loss in the normal operation but also have the less burden of electric power because of only limiting the initial fault current. We analyzed the characteristics of current, voltage according to the changes of turn ratio of 3 phase system in case of combinations of an SFCL to the neutral line. It was confirmed that the limiting rate of initial fault current by the increase of turn ratio was reduced.

Analysis of a Harmonics Neutralized 48-Pulse STATCOM with GTO Based Voltage Source Converters

  • Singh, Bhim;Saha, Radheshyam
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.391-400
    • /
    • 2008
  • Multi-pulse topology of converters using elementary six-pulse GTO - VSC (gate turn off based voltage source converter) operated under fundamental frequency switching (FFS) control is widely adopted in high power rating static synchronous compensators (STATCOM). Practically, a 48-pulse ($6{\times}8$ pulse) configuration is used with the phase angle control algorithm employing proportional and integral (PI) control methodology. These kinds of controllers, for example the ${\pm}80MVAR$ compensator at Inuyama switching station, KEPCO, Japan, employs two stages of magnetics viz. intermediate transformers (as many as VSCs) and a main coupling transformer to minimize harmonics distortion in the line and to achieve a desired operational efficiency. The magnetic circuit needs altogether nine transformers of which eight are phase shifting transformers (PST) used in the intermediate stage, each rating equal to or more than one eighth of the compensator rating, and the other one is the main coupling transformer having a power rating equal to that of the compensator. In this paper, a two-level 48-pulse ${\pm}100MVAR$ STATCOM is proposed where eight, six-pulse GTO-VSC are employed and magnetics is simplified to single-stage using four transformers of which three are PSTs and the other is a normal transformer. Thus, it reduces the magnetics to half of the value needed in the commercially available compensator. By adopting the simple PI-controllers, the model is simulated in a MATLAB environment by SimPowerSystems toolbox for voltage regulation in the transmission system. The simulation results show that the THD levels in line voltage and current are well below the limiting values specified in the IEEE Std 519-1992 for harmonic control in electrical power systems. The controller performance is observed reasonably well during capacitive and inductive modes of operation.

A Digitally Controlled Three-Phase Cycloconverter Type High Frequency AC Link Inverter Using Space Vector Modulation

  • Sha, Deshang;Qin, Zian;Wu, Dan;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.28-36
    • /
    • 2011
  • In this paper, a three phase cycloconverter type high frequency AC link inverter is discussed. The configuration consists of a high frequency full-bridge inverter and a high frequency transformer followed by a three phase cycloconverter whose switch is composed of anti-series connected MOSFETs with a common source. A simple digital control strategy based on space vector modulation (SVM) and repetitive control for the cycloconverter is proposed although its input voltage is a high frequency AC pulse. The operation principle of the proposed control strategy is analyzed and the equivalent working modes during one interval are also presented. The effectiveness of the proposed control strategy is verified through Matlab/Simulink simulations and experiments on a 1.45kW prototype.

A Three-Phase Line-Interactive UPS System to Eliminate the Inrush Current Phenomenon during Switching-in of an Auxiliary Load while Powering the Main Load

  • Bukhari, Syed Sabir Hussain;Ayub, Muhammad;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1623-1630
    • /
    • 2018
  • Normally, various auxiliary loads are installed along with the main load in industrial applications. Usually, load transformers are used to convey such types of auxiliary loads. The transformers become energized when the loads are turned-on, consequently, high amplitude of inrush current appears at the output of the uninterrupted power supply (UPS) system. To mitigate these high current amplitudes, this manuscript suggests a three-phase line-interactive UPS system to counter the inrush current during the turning-on of the auxiliary load transformer while powering the main load by using a current controlled inverter. Experimental results of a laboratory-sized prototype are provided in the support of the proposed UPS system for validation.

Implementation of Three-Phase SAMRT Meter using Programmable IC (Programmable IC를 이용한 다기능 전자식 삼상 전력량계 기능 구현)

  • Park, Jong-Beom;An, Yong-Ho;Kim, Hong;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2039-2041
    • /
    • 2001
  • According to the deregulation of governments in the world, the power industries of United State and European nations are proceeding remote meter reading and remote load control. But the core technology of multifunctional electronic meter implemented by programmable one-chip IC, which can be the right answer of ail the power industy's efforts is now still under development in the advanced countries. Implementation of smallest size, lowest price three-phase meter with features which enable distribution automation such as bidirectional communication. The three phase metering IC and meter can be used as metering, automatic meter reading and transformer monitoring. Prepayment billing system.

  • PDF

A Three Phase Three-level PWM Switched Voltage Source Inverter with Zero Neutral Point Potential

  • Oh Won-Sik;Han Sang-Kyoo;Choi Seong-Wook;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.224-232
    • /
    • 2005
  • A new three phase three-level Pulse Width Modulation (PWM) Switched Voltage Source (SVS) inverter with zero neutral point potential is proposed. It consists of three single-phase inverter modules. Each module is composed of a switched voltage source and inverter switches. The major advantage is that the peak value of the phase output voltage is twice as high as that of a conventional neutral-point-clamped (NPC) PWM inverter. Thus, the proposed inverter is suitable for applications with low voltage sources such as batteries, fuel cells, or solar cells. Furthermore, three-level waveforms of the proposed inverter can be achieved without the switch voltage imbalance problem. Since the average neutral point potential of the proposed inverter is zero, a common ground between the input stage and the output stage is possible. Therefore, it can be applied to a transformer-less Power Conditioning System (PCS). The proposed inverter is verified by a PSpice simulation and experimental results based on a laboratory prototype.