• 제목/요약/키워드: thermometer

검색결과 355건 처리시간 0.034초

측온저항체 온도센서가 집적화된 발열저항체형 마이크로 유량센서의 제작 및 특성 (Fabrication and Characteristics of Hot-Film Type Micro-flowsensors integrated with RTD)

  • 정귀상;홍석우
    • 한국전기전자재료학회논문지
    • /
    • 제13권7호
    • /
    • pp.612-616
    • /
    • 2000
  • This paper describes on the fabrication and characteristics of hot-film type micro-flowsensors integrated with Pt-RTD(resistance thermometer device) and micro-heater on the Si membrane in which MgO thin-film was used as medium layer in order to improve adhesion of Pt thin-film to SiO$_2$layer. The MgO layer improved adhesion of Pt thin-film to SiO$_2$layer without any chemical reactions to Pt thin-film under high annealing temperatures. Output voltages increased due to increase of heat-loss from sensor to external. The output voltage was 82 mV at $N_2$flow rate of 2000 sccm/min heating power of 1.2 W. The response time($\tau$:63%) was about 50 msec when input flow was stepinput

  • PDF

측온저항체 온도센서용 백금 박막의 형성에 관한 연구 (The Study on Fabrication of Platinum Thin Films for RTD)

  • 노상수;최영규;정귀상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.242-244
    • /
    • 1996
  • Platinum thin films were deposited on Si-wafer by DC magnetron sputtering for RTD (Resistance Thermometer Devices). We investigated the physical and electrical characteristics of these films under various conditions, the input power, working vacuum, temperature of substrate and also after annealing these films. The Resistivity and Sheet Resistivity were decreased with increasing the temperature of substrate and the annealing time at $1000^{\circ}C$. At substrate temperature $300^{\circ}C$, input power 7(w/$cm^2$), working vacuum 5mtorr and annealing conditions $1000^{\circ}C$, 240min we obtained $10.65{\mu}{\Omega}{\cdot}cm$, Resistivity of Pt thin film and $3000{\sim}3900ppm/^{\circ}C$, TCR(temperature coefficient of resistance) closed to the bulk value.

  • PDF

도시녹지의 포장유형이 감성이미지에 미치는 영향 (The Influence of Land Cover Types on Sensibility Image in Urban Greenspace)

  • 주창훈;박봉주;김원태;윤용한
    • 한국환경복원기술학회지
    • /
    • 제12권3호
    • /
    • pp.1-8
    • /
    • 2009
  • The present study was conducted with the object of measuring sensibility image through an experiment with human bodies and indexing human feelings according to land cover types. The temperature by land cover types formed the lowest temperature in planted areas and the highest temperature in paved areas. The wind velocity is stronger in bare grounds, the surface of water and building areas than planted areas, grassland and paved areas. In the case of using a globe thermometer, a solar controled device confirmed the planted areas. In summer, an increase of thermal sensation are indicated a decrease of amenity, and the sensation which has high correlationship is in order by amenity, thermal sensation, airflow sensation and humidity sensation.

SOI와 드랜치 구조를 이용한 초저소비전력형 미세발열체의 제작 (The fabrication of ultra-low consumption power type micro-heaters using SOI and trenche structures)

  • 정귀상;이종춘;김길중
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.569-572
    • /
    • 2000
  • This paper presents the optimized fabrication and thermal characteristics of micro-heaters for thermal MEMS applications using a SDB SOI substrate. The micro-heater is based on a thermal measurement principle and contains for thermal isolation regions a 10$\mu\textrm{m}$ thick silicon membrane with oxide-filled trenches in the SOI membrane rim. The micro-heater was fabricated with Pt-RTD(Resistance Thermometer Device)on the same substrate by using MgO as medium layer. The thermal characteristics of the micro-heater with the SOI membrane is 280$^{\circ}C$ at input Power 0.9 W; for the SOI membrane with 10 trenches, it is 580$^{\circ}C$ due to reduction of the external thermal loss. Therefore, the micro-heater with trenches in SOI membrane rim provides a powerful and versatile alternative technology for improving the performance of micro thermal sensors and actuators.

  • PDF

ADSL 모뎀용 시그마-델타 아날로그/디지털 변환기 (Sigma-Delta A/D Converter for ADSL Modems)

  • 한승엽;유상대;이주상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.950-953
    • /
    • 2003
  • In this paper, sigma-delta A/D converter for ADSL modems using oversampling technique is designed. Conventionally, the oversampling A/D converter is consist of opamps, switched capacitors, quantizers, infernal D/A converters, and decimation filters. 3-bit flash A/D converter, 3-bit thermometer-based D/A converters, and sub-blocks are used for high speed operation. HSPICE simulator and CADENCE tool are used for verification and layout of the designed modulator. The internal A/D converter and D/A converters are operated at 130 MHz. In design of decimation filter Matlab is used for calculating coefficients and ModelSim and VHDL are used for design.

  • PDF

광도전성저항을 이용한 열선유속계의 온도보상 (Temperature Compensation of Hot-Wire Anemometer with Photoconductive Cell)

  • 이신표;고상근
    • 대한기계학회논문집B
    • /
    • 제20권1호
    • /
    • pp.295-303
    • /
    • 1996
  • A new temperature compensation technique for hot-wire anemometer is proposed in this article. In contrast to the available compensation techniques, a photoconductive cell is introduced here as a variable resistor in the bridge. The major advantage of adopting an active component such as photoconductive cell is that temperature compensation can be achieved by using any kind of temperature sensors, once the output of temperature sensor is given as a voltage. Thereby, the temperature compensation can be made automatically and intelligently by a computer software or a hardware device. Validation experiments using a photoconductive cell with a thermocouple-thermometer are conducted in the temperature range from 3$0^{\circ}C$ to 5$0^{\circ}C$ and the velocity ranges from 8 m/s to 18 m/s.

Development and deployment of large scale wireless sensor network on a long-span bridge

  • Pakzad, Shamim N.
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.525-543
    • /
    • 2010
  • Testing and validation processes are critical tasks in developing a new hardware platform based on a new technology. This paper describes a series of experiments to evaluate the performance of a newly developed MEMS-based wireless sensor node as part of a wireless sensor network (WSN). The sensor node consists of a sensor board with four accelerometers, a thermometer and filtering and digitization units, and a MICAz mote for control, local computation and communication. The experiments include calibration and linearity tests for all sensor channels on the sensor boards, dynamic range tests to evaluate their performance when subjected to varying excitation, noise characteristic tests to quantify the noise floor of the sensor board, and temperature tests to study the behavior of the sensors under changing temperature profiles. The paper also describes a large-scale deployment of the WSN on a long-span suspension bridge, which lasted over three months and continuously collected ambient vibration and temperature data on the bridge. Statistical modal properties of a bridge tower are presented and compared with similar estimates from a previous deployment of sensors on the bridge and finite element models.

강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향 (Effects of an Aspirated Radiation Shield on Temperature Measurement in a Greenhouse)

  • 정영균;이종구;윤성욱;김현태;안은기;서재석;윤용철
    • 생물환경조절학회지
    • /
    • 제28권1호
    • /
    • pp.78-85
    • /
    • 2019
  • 본 연구에서는 본 연구실에서 자체적으로 제작한 비교적 제작이 간편하고 비용이 저렴한 강제 흡출식 복사선차폐장치(Aspirated Radiation Shield; ARS)로 측정한 실측 데이터를 바탕으로 장치의 성능과 온도 및 상대습도의 측정오차에 대하여 보고하고자 연구를 수행하였다. 그 결과를 요약하면 다음과 같다. ARS장치와 진주기상대에서 측정한 최대, 평균 및 최저온도의 범위는 각각 $2.0{\sim}34.1^{\circ}C$$0.4{\sim}31.5^{\circ}C$, $-6.1{\sim}22.2^{\circ}C$$-5.8{\sim}22.0^{\circ}C$, $-14.1{\sim}16.3^{\circ}C$$-14.0{\sim}15.1^{\circ}C$범위로 나타났다. 최대기온의 최저 및 최고온도에서 각각 $1.6^{\circ}C$$2.6^{\circ}C$정도 교내에서 측정한 값이 약간 높게 나타난 것을 제외하면, 두 기관에서 측정한 온도에 큰 차이가 없는 것을 알 수 있었다. 표준온도계의 측정값과 검증한 결과, ARS장치로 측정한 온도가 표준온도계에 비해 $-2.0^{\circ}C$정도 낮거나 $1.8^{\circ}C$보다 높게 나타나났다. 표준온도계와 상관분석 한 결과, 결정계수는 0.99정도였다. 팬의 유무에 따른 온도의 경우, 전체적으로 팬이 없는 경우가 최고, 평균 및 최저온도가 각각 $0.5{\sim}7.6^{\circ}C$, $0.3{\sim}4.6^{\circ}C$$0.5{\sim}3.9^{\circ}C$정도 높게 나타났다. 그리고 ARS장치와 진주기상대에서 측정한 일평균 상대습도는 전체적으로 ARS장치로 측정한 값이 약간 높은 경향이 있고, 특히 상대적으로 6월 27일, 7월 26일, 29일, 8월 20일에 측정한 값이 각각 5.7%, 5.2%, 9.1% 및 5.8%정도로 다소 높게 나타났지만, 두 기관의 월별 평균치는 2.0~3.0%정도로 미미한 수준이었다. 또한 ARS장치와 아스만 통풍습도계로 측정한 상대습도는 전체적으로 -3.98~+7.78%정도의 범위 내에 있는 것으로 나타났다. 진주기상대와 아스만 통풍습도계로 측정한 상대습도를 상관분석 결과, 결정계수가 각각 0.94 및 0.97정도로써 높은 상관관계를 보였다.

유방암 수술환자의 디스트레스 및 연관인자 : 단면연구 (Distress and Associated Factors in Patients with Breast Cancer Surgery : A Cross-Sectional Study)

  • 이상신;임효덕;우정민
    • 정신신체의학
    • /
    • 제26권2호
    • /
    • pp.77-85
    • /
    • 2018
  • 연구목적 유방암 환자가 치료 초기에 경험하는 디스트레스는 유방암 생존기까지 지속되는 만성 디스트레스의 위험요소로 알려져 있다. 본 연구는 유방암 첫 치료로써 수술을 받은 환자를 대상으로 디스트레스 온도계(distress thermometer, DT)를 이용하여 디스트레스의 정도와 이와 연관된 인자를 조사하는 것이다. 방 법 2013년 4월 1일부터 2017년 3월 31일 사이에 경북대학교병원에서 유방암 첫 치료로써 수술을 받고 일주일 이내에 있는 환자를 대상으로 하였다. DT로 디스트레스의 정도를 측정하였고 한국판 세계보건기구 삶의 질척도 단축형(Korean version of the World Health Oganization Quality of Life Scale Abbreviated Version, WHOQOL-BREF)으로 삶의 질을 측정하였다. 그 외 기본 인구학적 자료, 암 및 암 치료 관련 자료를 수집하였다. DT 점수 4점 이상인 대상자를 디스트레스 군으로 분류하였다. 디스트레군과 연관된 인자를 알기 위하여 디스트레스군과 비-디스트레스 군 사이의 변수 차이를 단변수 분석(univariable analysis) 하였다. 로지스틱 회귀분석을 시행하여 디스트레스 군을 예측할 수 있는 인자를 조사하였다. 결 과 대상자는 총 307명이었다. 이 중에서 DT에 응답하지 않은 39명, WHOQOL-BREF에서 6개 항목 이상 답을 하지 않아서 채점을 할 수 없었던 4명을 제외한 264명이 분석 대상자였다. 65.5%(n=173)가 디스트레스 군으로 분류되었다. 단변수 분석(univariable analysis)에서 디스트레스 군이 비-디스트레스 군과 비교하여 더 젊었으며(p=0.045), 배우자와 동거하지 않는 경우가 더 많았다(p=0.032). 삶의 질 영역에서 디스트레스 군이 전반적 삶의 질(p=0.009), 전반적 건강상태(p=0.005), 신체건강영역 p<0.001), 심리건강영역(p=0.002)에서 더 나쁜 삶의 질을 보였다. 로지스틱 회귀분석에서 60세 이상의 환자에 비하여 40-49세의 환자가 디스트레스에 이환 될 확률이 약 3배 높았고[OR=2.992, 95% confidence intervals (CI) 1.241-7.215], WHOQOL-BREF영역 중 신체건강영역이 디스트레스를 예측할 수 있는 인자로 나타났다(OR=0.777, 95% CI 0.692-0.873). 결 론 유방암 수술 치료 초기단계에서부터 상당한 수의 환자가 유의한 수준의 디스트레스를 경험하고 있다. 특히 생산성이 왕성한 삶의 주기에 있는 40대의 환자가 60대 이상의 환자에 비하여 수술 후 일주일 이내에 겪는 심리적 고통이 심할 가능성이 높다. 이러한 환자들에게서 수술 초기부터 신체적 삶의 질과 연관된 영역(예 : 통증, 불면, 피로 등)에 대해 평가하고 개입하는 것이 디스트레스 수준을 경감시킬 가능성이 있다.

서리 피해 방지를 위한 서리 발생일의 기상 특성에 대한 연구 (The Weather Characteristics of Frost Occurrence Days for Protecting Crops against Frost Damage)

  • 권영아;이효신;권원태;부경온
    • 대한지리학회지
    • /
    • 제43권6호
    • /
    • pp.824-842
    • /
    • 2008
  • 본 연구는 서리에 의한 피해를 최소화하기 위하여 서리 발생일의 기상 요소별 특성을 분석하여 서리가 발생할 수 있는 기상 조건을 파악하였다. 첫서리 현상이 발생하는 시기인 가을과 마지막 서리 현상이 나타나는 봄으로 나누어 서리 현상일의 기압계 유형, 최저기온, 초상최저기온, 일교차, 평균 상대습도, 최소상대습도, 평균 풍속 자료를 분석에 이용하였다. 기압계 유형별로는 우리나라 남서쪽에 중심을 둔 이동성 고기압의 영향을 받고 있을 때 서리 현상은 가장 잘 발생했다. 초상최저기온은 지표에 발생하는 서리 현상을 감지하기 때문에 농업적 목적으로는 최저기온보다 더 중요하다. 본 연구에서도 해안지역의 경우는 최저기온이 영상이어도 서리가 발생했으나 서리 발생일의 초상최저기온은 모든 지역에서 영하였다. 서리 현상일의 일교차는 내륙 지역은 $14^{\circ}C$ 이상이었으며, 해안 지역은 $9{\sim}12^{\circ}C$이었다. 서리 현상이 발생하기 위한 최소상대습도는 $30{\sim}50%$였으며, 내륙 지역이 해안 지역보다 낮았다. 풍속은 약할수록 서리가 발생하기 쉬우므로 대부분 지역에서 서리가 발생한 날의 평균 풍속은 2m/sec 이하였으며 일부 도서 지역과 해안 지역에서는 $4{\sim}6m/sec$를 나타냈다.