• Title/Summary/Keyword: thermoelectric.

Search Result 891, Processing Time 0.023 seconds

Variable Optical Attenuator Incorporating Dual Fiber Collimator and Bi-metal Actuator (이중 광 콜리메터와 바이메탈 엑추에이터를 이용한 가변 광감쇠기)

  • Kim, Kwang Taek;Kim, Duck Bong;Koh, Hanjun
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.1
    • /
    • pp.28-31
    • /
    • 2018
  • In this paper, we have proposed and demonstrated a variable optical attenuator (VOA) incorporating a dual-fiber collimator and a bimetallic actuator. The optical attenuation between input and output single-mode fibers was tuned by tilting the angle of a reflection mirror fixed on the bimetal. The bimetal was heated or cooled by a thermoelectric cooler (TEC) and then moved the reflection mirror, due to bending and unreeling. The desired optical attenuation can be obtained through adjusting the electrical input into the TEC. The fabricated device showed 0.5 dB of insertion loss, 0.2 dB of maximum polarization-dependent loss, and 40 dB of dynamic range. The response time was measured to be about 5 s.

Optimization of Heat exchanger Capacity to Maximize the Performance and Energy Efficiency of TEM Dehumidifiers (열전모듈 제습기의 제습 능력 및 에너지 효율 극대화를 위한 열교환기 용량 최적화)

  • Lee, Tae-Hee
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.3
    • /
    • pp.13-20
    • /
    • 2021
  • The capacity optimization of the heat exchanger of the TEM dehumidifier was performed through numerical analysis. If the ratio of the size of heat exchangers on the cold and hot surfaces of the TEM is not appropriate, the larger the size of the heat exchanger results the lower performance and efficiency. Optimizing the ratio of heat exchangers on the cold surface of TEM can improve the performance and the efficiency compared to when the ratio is 50%. The optimal proportion of cold surface heat exchangers is inversely proportional to the sum of the size of the heat exchangers on the cold and hot surfaces. When the optimum ratio of cold surface heat exchanger was applied, the larger the sum of size of the two heat exchangers results the greater the improvement of the performance and efficiency, compared to when the ratio of cold surface heat exchangers is 50%.

Electrical Properties of n-type Co-doped Fe-Si Alloy (Co 첨가 Fe-Si n형 반도체의 전기적 특성)

  • Pai, Chul-Hoon;Kim, Jeung-Gon
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.12
    • /
    • pp.860-865
    • /
    • 2009
  • The effect of Co additive on the electrical properties of Fe-Si alloys prepared by a RF inductive furnace was investigated. The electrical conductivity and Seebeck coefficient were measured as a function of the temperature under an Ar atmosphere to evaluate their applicability to thermoelectric energy conversion. The electrical conductivity of the specimens increased as the temperature increased, showing typical semiconducting behavior. The electrical conductivity of Co-doped specimens was higher than that of undoped specimens and increased slightly as the amount of Co additive increased. This is most likely due to the difference in the carrier concentration and the amount of residual metallic phase ${\varepsilon}$-FeSi (The ${\varepsilon}$-FeSi was detected in spite of an annealing treatment of 100 h at $830^{\circ}C$). Additionally, metallic conduction increased slightly as the amount of Co additive increased. On the other hand, Co-doped specimens showed a lower Seebeck coefficient due to the metallic phase. The power factor of Co-doped specimens was higher than that of undoped specimens. This would be affected more by the electrical conductivity compared to the Seebeck coefficient.

Thermal Conductivity in Individual Single-Crystalline PbTe Nanowires (단결정 PbTe 단일 나노선의 열전도도)

  • Roh, Jong Wook;Jang, So Young;Kang, Joohoon;Lee, Seunghyun;Noh, Jin-Seo;Park, Jeunghee;Lee, Wooyoung
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.2
    • /
    • pp.175-179
    • /
    • 2010
  • We investigated the thermal conductivity of individual single-crystalline PbTe nanowires grown by chemical vapor transport method. Suspended MEMS was utilized to precisely measure the thermal conductivity of an individual nanowire. The thermal conductivity of a PbTe nanowire with diameter of 292 nm was measured to be $1.8W/m{\cdot}K$ at 300 K, which is about two thirds of that of bulk PbTe. This result indicates that the thermal conduction through a PbTe nanowire is effectively suppressed by the enhanced phonon boundary scattering. As the diameter of a PbTe nanowire decreases, the corresponding thermal conductivity linearly decreases.

Effects of Progressive Scapular Stabilization Exercise on Neck, Muscle Strength, Upper Extremity Function in Patients with Acute Whiplash Injury

  • In-Cheol Noh;Won-Seob Shin
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.3
    • /
    • pp.310-319
    • /
    • 2023
  • Objective: The purpose of this study was to investigate the effects of a combination of progressive scapular stabilization exercises, neck and thoracic spine mobilization, and thermoelectric physical therapy on pain, range of motion, muscle strength, and function in patients with acute whiplash injury. Design: A randomized controlled trial design. Methods: A total of 24 subjects were included in this study. They were randomly assigned to an experimental group (n=12) that performed scapular stabilization exercises, neck and thoracic spine mobilization, and physiotherapy, and a control group (n=12) that only performed neck and thoracic spine mobilization and physiotherapy. The pre-test was conducted before the intervention and consisted of a total of 12 treatment sessions of 60 minutes each, three times a week. A posttest was conducted 4 weeks later. Pain, range of motion, muscle strength, and function were assessed before and after intervention. Results: The results of the study showed that there was a significant difference in pain reduction and range of motion and muscle strength improvement in the experimental group, and a significant difference was also found between the experimental group and the control group in terms of functional evaluation. Conclusions: The combination of exercise therapy and joint mobilization technique and physical therapy resulted in greater improvements in pain, range of motion, strength, and function assessment, contributing to improved overall function.

Enhancement of Power Generation in Hybrid Thermo-Magneto-Piezoelectric-Pyroelectric Energy Generator with Piezoelectric Polymer (압전 폴리머를 접목한 초전-자기-압전 발전소자의 출력 특성 향상 연구)

  • Chang Min Baek;Geon Lee;Jungho Ryu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.620-626
    • /
    • 2023
  • Energy harvesting technology, which converts wasted energy sources in everyday life into usable electric energy, is gaining attention as a solution to the challenges of charging and managing batteries for the driving of IoT sensors, which are one of the key technologies in the era of the fourth industrial revolution. Hybrid energy harvesting technology involves integrating two or more energy harvesting technologies to generate electric energy from multiple energy conversion mechanisms. In this study, a hybrid energy harvesting device called TMPPEG (thermo-magneto-piezoelectric-pyroelectric energy generator), which utilizes low-grade waste heat, was developed by incorporating PVDF polymer piezoelectric components and optimizing the system. The variations in piezoelectric output and thermoelectric output were examined based on the spacing of the clamps, and it was found that the device exhibited the highest energy output when the clamp spacing was 2 mm. The voltage and energy output characteristics of the TMPPEG were evaluated, demonstrating its potential as an efficient hybrid energy harvesting component that effectively harnesses low-grade waste heat.

Engineering Properties of Fly Ash-WFS Mixed Materials as a Flow able Backfill (유동성 뒷채움재로 사용하기 위한 플라이에쉬-폐주물사 혼합재료의 특성 연구)

  • 이관호;이인모;조재윤;윤여준
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.489-496
    • /
    • 1999
  • The objective of this study is to present engineering properties required in use of co-mixtures of fly ash and WFS(Waste Foundry Sand)'s, which are Presently used as fill or (lovable backfill. The fly ash, generated at the Tae-An thermoelectric power plant was used in this research and was classified as Class F. Green Sand, Furane Sand, and Coated Sand, which had been used at a foundry located in Pusan, were used. Laboratory experiments were peformed to obtain the physical properties of the co-mixture of fly ash and WFS. The range of permeability for all the co-mixtures was from 3.0×10/sup -3/㎝/s to 6.0×10/sup -5/㎝/s. The unconfined strength of the 7-day cured specimens composed of Green Sand reached 94% of that of 28-day cured specimens but for the 7-day cured specimens composed of, respectively, Furnace Sand and Coated Sand, only 64% and 66% of the strength of the 28-day cured specimens were reached. Results of the consolidated-untrained triaxial test showed that the specimens composed of Furnace Sand showed a distinct increase of the internal friction angle, while the other specimens showed negligible increase. In the case of 28-day cured specimens, specimens composed of Furnace Sand showed an internal friction angle of 41.8°, while specimens of Green and Coated Sand showed those of 33.5° and 35.0°, respectively. From the shrinkage test, the shrinkage ratios of all specimens did not exceed 0.25%.

  • PDF

A Study on Constitution of Plant Safety Inspection System for Measuring Joint Axial Force of High Tension Bolt (고장력 볼트의 체결축력 측정을 위한 설비 안전 검사 시스템 구축에 관한 연구)

  • Kim, J.Y.;Park, S.G.;Kim, H.S.;Kim, C.H.;You, S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.371-377
    • /
    • 1995
  • By using ultrasonic waves, we obtained conclusion from the experiment for measuring joint axial force of high tension bolt. The conclusion is followed. : From the high tension bolts used at turbine of Thermoelectric Power Plant, we obtained the equation of calculating joint axial force that is ${\sigma}=\frac{{\Delta}BPD}{j{\times}{\Sigma}{\delta}}$. By using IBM PC, which is inputed by the equation for calculating joint axial force of high tension bolts, we got joint axial force of high tension bolts form beam path of ultrasonic waves. Furrther, we can identify that constitution of plant safety inspection system is possible.

  • PDF

Study of On-chip Liquid Cooling in Relation to Micro-channel Design (마이크로 채널 디자인에 따른 온 칩 액체 냉각 연구)

  • Won, Yonghyun;Kim, Sungdong;Kim, Sarah Eunkyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.31-36
    • /
    • 2015
  • The demand for multi-functionality, high density, high performance, and miniaturization of IC devices has caused the technology paradigm shift for electronic packaging. So, thermal management of new packaged chips becomes a bottleneck for the performance of next generation devices. Among various thermal solutions such as heat sink, heat spreader, TIM, thermoelectric cooler, etc. on-chip liquid cooling module was investigated in this study. Micro-channel was fabricated on Si wafer using a deep reactive ion etching, and 3 different micro-channel designs (straight MC, serpentine MC, zigzag MC) were formed to evalute the effectiveness of liquid cooling. At the heating temperature of $200^{\circ}C$ and coolant flow rate of 150ml/min, straight MC showed the high temperature differential of ${\sim}44^{\circ}C$ after liquid cooling. The shape of liquid flowing through micro-channel was observed by fluorescence microscope, and the temperarue differential of liquid cooling module was measuremd by IR microscope.

Development of System and Measured Results for Measuring Insulation Resistance of High-Power Cables in Operation (활선 고전력 케이블의 절연저항을 측정하기 위한 시스템 설계 및 측정결과)

  • Um, Kee-Hong;Kim, Bo-Kyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.165-170
    • /
    • 2016
  • The XLPE(or CV) cables installed to deliver high electric power from generator at the power station have operating for the last 40 years in Korea. In 6-8 years from the time of initial operation, the cables in operation start a deteriorating process, depending on the installation and usage conditions. Some cables, even before 6-8 years from the installation, can cause accidents due to the faulty construction or other inadequate environments. In order to prevent cable accident in advance, the regular auditing of power cables are required. For a systematic realization of surveillance and prevention of accidents, we have invented a measuring device. In this paper, we present the device installed at Korean Western Power Co. Ltd., in order to detect the deterioration status of insulation resistances of dielectrics in the cables. We present that the measured results by the device we developed show the deteriorating processes in the cables in operation.