• 제목/요약/키워드: thermocycling

검색결과 229건 처리시간 0.024초

Quantitative real-time PCR assays for the concurrent diagnosis of infectious laryngotracheitis virus, Newcastle disease virus and avian metapneumovirus in poultry

  • Mo, Jongseo;Angelichio, Michael;Gow, Lisa;Leathers, Valerie;Jackwood, Mark W.
    • Journal of Veterinary Science
    • /
    • 제23권2호
    • /
    • pp.21.1-21.7
    • /
    • 2022
  • Newcastle disease (ND), infectious laryngotracheitis (ILT) and avian metapneumovirus (aMPV) can be similar making it critical to quickly differentiate them. Herein, we adapted pre-existing molecular-based diagnostic assays for NDV and ILTV, and developed new assays for aMPV A and B, for use under synchronized thermocycling conditions. All assays performed equivalently with linearity over a 5 log10 dynamic range, a reproducible (R2 > 0.99) limit of detection of ≥ 10 target copies, and amplification efficiencies between 86.8%-98.2%. Using biological specimens for NDV and ILTV showed 100% specificity. Identical amplification conditions will simplify procedures for detection in diagnostic laboratories.

Sealed amalgam restoration의 미세누출에 관한 연구 (A STUDY ON MICROLEAKAGE OF SEALED AMALGAM RESTORATION)

  • 이상헌;이재천;이상훈
    • 대한소아치과학회지
    • /
    • 제27권1호
    • /
    • pp.54-61
    • /
    • 2000
  • 아말감은 널리 사용되어 온 대표적 치과재료이지만 치질과의 접착성이 없어 와동의 형태에 의해 유지되는 단점을 가진다. 아말감 수복물은 산화물에 의한 변연봉쇄가 일어나기 전까지 초기에 큰 미세누출을 보이며 수복초기에 이를 적절하게 예방하지 않으면 타액이나 미생물이 와동내에 침투하게 되고 이로 인해 수복 후의 과민반응, 충전물의 용해 및 파괴, 변연 변색과 2차 우식이 유발되어, 결과적으로 수복물의 수명이 단축되며 치수 병변이 발생될 수도 있다. 최근 기존 아말감 수복의 장점을 그대로 유지하면서 치질삭제를 줄이고 변연을 봉쇄하며 소와열구에 예방적 처치를 함께 할 수 있는 수복법이 제안되었는데 이를 이른바 sealed amalgam이라 한다. 이 술식은 예방적 확대 없이 병소만을 제거한 뒤 수복물 변연과 인접 소와열구에 치면열구전색재를 도포함으로서 소와열구의 예방적 충전은 물론 수복물 변연과 치질사이의 틈을 봉쇄하여 미세누출을 감소시킬 수 있다고 하였다. 이에 저자는 아말감 수복후 수복물의 마무리 처리와 전색재 적용시점을 달리 하여 sealed amalgam 수복과 기존의 아말감 수복과의 미세누출의 차이를 비교하고자 30개의 상, 하악 소구치를 준비하여 V급 와동을 소구치의 협, 설측에 형성하고 통상적 아말감 수복을 시행한 후 다음의 각 군으로 나누어 처리하였다. 제 1 군 : 24시간 후 연마 (대조군) 제 2 군 : 연마하지 않음, 즉시 전색재 적용 제 3 군 : 연마하지 않음, 열순환(thermocycling) 500회 후 전색재 적용 위의 처리 후 각 군을 $5^{\circ}C$$55^{\circ}C$의 온도변화를 30초씩 번갈아 주며 총 500회의 열순환을 실시한 후 1% methylene blue 용액에 침윤시켜서 100% 습도가 유지된 $37^{\circ}C$ 항온기에 24시간 보관하였다. 치아를 레진에 매몰한 후 협설측으로 치아 장축에 평행하게 절단하여 stereomicroscope를 사용해 색소침투도를 관찰하여 다음과 같은 결론을 얻었다. 1. 평균 미세누출은 연마하지 않고 바로 치면열구전색재를 도포한 2군이 가장 낮았고, 연마만 시행한 1군이 가장 높았다. 2. 실험군간의 미세누출 비교에서 연마만 시행한 1군은 2군에 비해 미세누출이 켰으며 통계적으로 유의성 있는 차이를 보였다(p<0.05). 3군은 1군보다 평균미세누출이 작았으나 통계적으로 유의한 차이가 없었다(p>0.05). 2군은 3군보다 평균 미세누출이 작았으나 통계적으로 유의한 차이가 없었다(p>0.05).

  • PDF

제V급 복합레진 수복물의 표면전색이 미세변연누출에 미치는 효과 (The Effect of Surface Sealing on the Microleakage of Class V Composite Resin Restorations)

  • 윤연희;현홍근;김영재;김정욱;장기택;이상훈;김종철;한세현
    • 대한소아치과학회지
    • /
    • 제34권3호
    • /
    • pp.359-369
    • /
    • 2007
  • 본 연구는 다양한 순환 및 시효 조건 하에서 제V급 복합레진 수복물의 표면전색이 미세변연누출에 미치는 효과에 대해 알아보고자 하였다. 100개의 건전한 소구치의 협면에 제V급 와동을 형성하고 제조사의 지시대로 광중합형 복합레진으로 수복하였다. 무작위로 나누어 표면전색을 시행하지 않는 I군과 표면을 산부식 후 표면전색을 시행한 II군으로 설정한 후 열순환(thermocycling)을 하였다. 각 군에서 하위군(A군= 열순환 외 다른 시효조건이 없는 군, B군=칫솔질군, C군=부하순환군, D군=칫솔질과 부하순환을 모두 시행한 군, E군=6개월간 증류수에 보관한 군)으로 나누어 각각에 맞는 시효조건을 시행하였다. 2% methylene blue 용액에 침윤시켜 변연의 미세누출정도를 평가하여 다음과 같은 결과를 얻었다. 1. 표면전색을 시행하지 않은 군의 교합변연과 치은변연에서 시효조건에 따른 미세누출의 유의한 차이는 보이지 않았다(p>0.05). 2. 표면전색을 시행한 군의 교합변연에서는 시효조건에 따른 미세누출의 유의한 차이가 없었다(p>0.05). 3. 표면전색을 시행한 군의 치은변연에서는 부하순환이나 6개월간 증류수에서 보관하는 시효과정을 거친 군에서 미세누출이 유의하게 크게 나타났다(p<0.05). 4. 시효조건이 없는 군과 칫솔질군의 경우, 표면전색을 시행한 군이 표면전색을 시행하지 않은 군에 비해 유의하게 적은 미세누출결과를 보였다(p<0.05). 5. 부하순환을 시행한 군과 6개월간 증류수에서 보관한 경우에는 표면전색을 시행한 군과 표면전색을 시행하지 않은 군 사이에 미세누출의 차이가 있었지만 유의차가 없었다(p>0.05). 따라서 이 연구의 결과는 변연부분의 미세간격으로 침투한 표면전색제가 처음에는 미세누출을 감소하는데 효과를 보여주었으나, 교합시 교두가 휘어져서 생기는 응력과 장기간의 수분흡수로 인한 변화를 견디기에 불충분함을 보여주었다.

  • PDF

터널형 2급와동 충전재의 탄성계수와 전단결합강도 및 수복치의 변연융선 파절강도에 관한 연구 (ELASTIC CONSTANTS, SHEAR BOND STRENGTH OF TUNNEL RESTORATIVE MATERIALS AND MARGINAL RIDGE STRENGTH OF RESTORED TEETH)

  • 이가연;박영준;양규호
    • 대한소아치과학회지
    • /
    • 제23권3호
    • /
    • pp.746-763
    • /
    • 1996
  • An alternative design to conventional class II cavity preparation for proximal carious lesions is the tunnel preparation. It preserves the marginal ridge intact, thus making it possible to maintain the natural contact relationship with the adjacent tooth and minimize tooth reduction. This in vitro study was purposed to evaluate the effect of the materials' elastic constants and shear-bond strength on the marginal ridge fracture resistance of teeth restored by the tunnel technique, and to find the materials of choice for tunnel restorations. $Resinomer^{(R)}$, $Ketac-silver^{(R)}$, $Miracle-Mix^{(R)}$, and Tytin were used as restorative material. The elastic constants of each restorative material were evaluated by ultrasonic pulse measurement. Young's modulus and bulk modulus of the restorative materials were evaluated in three specimens for each material type. The shear-bond strength of the restorative materials to the dentin surface was measured after thermocycling 400 times between 6 and $60^{\circ}C$, using ten specimens for each material type. For measuring marginal ridge strength, 60 sound extracted molar teeth were distributed into six groups by size. Sound molar teeth were used as a Control group and unfilled prepared teeth were grouped as Unrestored. Another four groups were named Resinomer group, Ketac-Silver group, Miracle Mix group, and Tytin group by type of restorative material. Tunnel cavity preparation was done with ' 1/2, 2, and 4 round burs in sequence. Initial access to proximal surface was made through an occlusal access preparation started at least 2mm from the marginal ridge, and the proximal opening was formed about 2.5mm below the marginal ridge. After restoration and thermocycling, marginal ridge strength was measured using a universal testing machine. The results were as follows: 1. The Young's modulus of $Tytin^{(R)}$ was 63.95 GPa, followed by $Ketac-Silver^{(R)}$ 27.60 GPa, $Miracle-mix^{(R)}$ 18.48 GPa, and $Resinomer^{(R)}$ 10.74 GPa showing significant differences between the groups(P<0.05). The bulk modulus of the materials showed the same order as Young's modulus. The value of $Tytin^{(R)}$ showed 59.57 GPa indicating that it will deform less than other materials under the same stress. It was followed by $Ketac-Silver^{(R)}$ 23.57 GPa, Miracle $Mix^{(R)}$ 12.50 GPa, and $Resinomer^{(R)}$ 11.60 GPa. 2. The Resinomer group had a shear-bond strength of 7.41 MPa which was significantly higher than those of the Ketac-Silver group (1.80 MPa) and the Miracle Mix group (2.84 MPa) (P<0.01). All the specimens of Tytin group detatched from the dentin surface during thermocycling. 3. The mean marginal ridge strength of the Unrestored group(46.14 kgf) was significantly lower than that of the Control group (84.24 kgf) (P<0.01). The marginal ridge strength of teeth restored by the tunnel technique was, in order, Ketac-Silver group 74.06 kgf, Miracle Mix group 73.36 kgf, Resinomer group 63.47 kgf, and Tytin group 58.76 kgf. The Ketac-Silver, Miracle Mix, and Resinomer groups showed no significant difference with the Control group (P>0.05), but the Tytin group showed significantly lower strength compared to the Control group(P<0.05). The results showed that the marginal ridge strength of the teeth restored by the tunnel technique was not significantly lower than that of sound teeth. They also demonstrated that the bonding strength of the restorative material to the tooth surface should be high and the modulus of elasticity should not be lower than that of the tooth in order to restore the marginal ridge strength to its natural condition.

  • PDF

컴포머에 대한 복합레진의 전단결합강도에 관한 연구 (A STUDY ON THE RELATIVE SHEAR BOND STRENGTH OF COMPOSITE RESIN TO COMPOMERS)

  • 정송란;최남기;양규호;김선미;송호준
    • 대한소아치과학회지
    • /
    • 제32권3호
    • /
    • pp.509-516
    • /
    • 2005
  • 컴포머(compomer) 충전물이 파절될 경우 즉, 컴포머 수복이 실패했을 때 기존 컴포머의 파절된 부분(aged compomer)을 복합레진으로 수복해야 하는 경우를 고려해야 한다. 본 연구에서는 컴포머의 표면처리 방법에 따른 수리(repair)를 위한 복합레진과의 전단결합강도 변화를 알아보기 위해 두 개의 mold를 만들어서 Dyract AP, F2000를 컴포머 수복재료로, Z250을 수리용 복합레진 재료로 사용하여 컴포머와 레진을 부착시킨 시편을 제작하였다. 컴포머와 복합레진의 종류 조합, 본딩레진 사용유무, 열순환 처리 유무, 표면거칠기 부여 유무, 기존 수복물의 시효(aging)에 따라 10개의 군으로 나누어, 컴포머와 복합레진간의 전단결합강도를 측정하고 그 파절양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 컴포머의 복합레진에 대한 전단결합강도를 측정한 결과, Dyract AP가 F2000 보다는 높은 전단강도 값을 보였으나 통계적으로 유의한 차이는 없었으며(p>0.05), fresh 컴포머군이 aged 컴포머군보다 결합강도가 높았다(p<0.05). 2. 각 군간의 전단결합강도를 측정한 결과 Dyract AP에 접착제를 도포하고 Z250을 접착시킨 제 5군이 가장 높았으며, Dyract AP를 충전하고 1주일간 물에 보관한 후 건조시켜 표면을 roughening 한 후 Z250을 충전시킨 제 9군에서 가장 낮았다(p<0.05). 3. 열순환을 시행한 군이 시행하지 않은 군보다 전단결합강도가 낮게 나타났으나 통계적으로 유의한 차이는 없었다. 4. 각 재료들의 결합실패가 일어난 파절단면을 조직학적으로 관찰한 결과, 전반적으로 접착파괴를 보였으나, 접착제를 도포한 군에서는 응집파괴가 우세하게 나타났다. 이상의 결과 fresh 컴포머 위에 접착제를 도포한 다음 수리용 복합레진 재료를 사용함으로써 컴포머와 복합레진간의 결합력을 증가시킬 수 있음을 알 수 있었다. 그리고 fresh 컴포머 위에 복합레진을 즉시 충전한 경우가 높은 결합력을 얻을 수 있었다. Aged 컴포머와 복합레진간의 성공적인 결합력을 얻으려면 aged 컴포머의 표면을 mechanically roughening하고 접착제를 도포한후 복합레진을 충전해야 할 것으로 사료된다.

  • PDF

Ceromer crown의 교합면 두께에 따른 압축 파절 강도의 비교 (The compressive fracture strength of ceromer crown by the difference of occlusal thickness)

  • 김지연;박하옥;양홍서
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.205-215
    • /
    • 2002
  • This study investigated the compressive fracture strength of Targis ceromer crown by the difference of occlusal thickness on a maxillary first premolar. Control group was a castable IPS-Empress all-ceramic crown with occlusal thickness of 1.5 mm constructed by layered technique. Experimental groups were Targis crowns having different occlusal thicknesses of 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, respectively. The classification of Targis group is T10, T15, T20, T25 and T15N (for no-thermocycling and occlusal thickness of 1.5mm). Ten samples were tested per each group. Except occlusal thickness, all dimension of metal die is same with axial inclination of $10^{\circ}$and marginal width 0.8mm chamfer. All crowns were cemented with Panavia F and thermocycled 1,000 times between $5^{\circ}$ and $55^{\circ}$ water bath with 10 sec dwelling time and 10 sec resting time. The compressive fracture strength was measured by universal testing machine. The results were as follows : 1. Fracture strength was increased as the occlusal thickness increased : compressive fracture strength of Group T10, T15, T20, T25 was $66.65{\pm}4.88kgf$, $75.04{\pm}3.01kgf$, $87.07{\pm}7.06kgf$ and $105.03{\pm}10.56kgf$, respectively. 2. When comparing material, Targis crown had higher fracture strength than IPS-Empress crown : the mean compressive strength of group T15 was $75.04{\pm}3.01kgf$ and the value of group Control was $37.66{\pm}4.28kgf$. 3. Fracture strength was decreased by thermocycling : the compressive fracture strength of T15 was $75.04{\pm}3.01kgf$, which is lower than $90.69{\pm}6.88kgf$ of group T15N. 4. The fracture line of crowns began at the loading point and extended along long axis of tooth. IPS-Empress showed adhesive failure pattern whereas Targis had adhesive and cohesive failure. In the SEM view, stress was distributed radially from loading point and the crack line was more prominent on Targis crown.

강화형 간접복합레진과 치과용 합금의 결합강도에 관한 연구 (A STUDY ON THE BOND STRENGTH OF REINFORCED INDIRECT COMPOSITE RESINS TO DENIAL ALLOYS)

  • 윤동주;신상완;임호남;서규원
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.620-639
    • /
    • 1999
  • Indirect composite resins are used as an popular effective esthetic material in prosthetic dentistry, often with metallic substructure that provides support for restorations. Recently, new indirect composite resins as a substitute of ceramic have been developed. These resins provide good esthetics, with a wide range of hue and chroma. And the flexural strength of those is in the range of 120-150MPa, Which is higher than that of feldspathic Ceramic, and similar th that of Dicor. Although it has many merits, one of the major clinical problems of composite resins is the bond failure between metal and resin due to insufficient interfacial bond strength. The purpose of this study was to evaluate shear bond strength of the reinforced indirect composite resin to dental alloys. Three different composite resin systems($Artglass^{(R)},\;Sculpture^{(R)},\;Targis^{(R)}$) as test groups and ceramic($VMK\;68^{(R)}$) as control group were bonded to Ni-Cr-Be alloy($Rexillium\;III^{(R)}$) and gold alloy(Deva 4). All specimens were stored at $^37{\circ}C$ distilled water for 24 hours and the half of specimens were thermocycled 2000 times at temperature from $5^{\circ}C\;to\;60^{\circ}C$. The shear bond strengths of reinforced indirect composite resins to dental alloys were measured by using the universal testing machine, and modes of debonding were observed by stereoscope and scanning electron microscope. The results were as follows: 1 The shear bond strengths of reinforced indirect composite resins to dental alloys were approximately half those of ceramic to dental alloys(P<0.01). 2. There was no significant difference between the shear bond strength of several reinforced indirect composite resins to metal. 3. Alloy type did not affect on the shear bond strengths of resin to metal, but the shear bond strengths of ceramic to gold alloys were higher than those of ceramic to Ni-Cr alloys(P<0.05). 4. The shear bond strengths of Artglass and Targil to gold alloys were significantly decreased after thermocycling treatment(P<0.01). 5. Sculpture showed cohesive, adhesive, and mixed failure modes, but Artglass and Targis showed adhesive or mixed failures. And ceramic showed cohesive and mixed failures.

  • PDF

Effect of Accelerated Aging on the Color Stability of Dual-Cured Self-Adhesive Resin Cements

  • Kim, Ah-Rang;Jeon, Yong-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • 제8권2호
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: The effect of accelerated aging on color stability of various dual-cured self-adhesive resin cements were evaluated in this study. Materials and Methods: Color stability was examined using three different brands of dual-cured self-adhesive resin cements: G-CEM LinkAce (GC America), MaxCem Elite (Kerr), and PermaCem 2.0 (DMG) with the equivalent color shade. Each resin cement was filled with Teflon mold which has 6 mm diameter and 2 mm thickness. Each specimen was light cured for 20 seconds using light emitting diode (LED) light curing unit. In order to evaluate the effect of accelerated aging on color stability, color parameters (Commission Internationale de l'Eclairage, CIE $L^*$, $a^*$, $b^*$) and color differences (${\Delta}E^*$) were measured at three times: immediately, after 24 hours, and after thermocycling. The $L^*$, $a^*$, $b^*$ values were analyzed using Friedman test and ${\Delta}E^*$ values on the effect of 24 hours and accelerated aging were analyzed using t-test. These values were compared with the limit value of color difference (${\Delta}E^*=3.7$) for dental restoration. One-way ANOVA and Scheff's test (P<0.05) were performed to analyze each ${\Delta}E^*$ values between cements at each test period. Result: There was statistically significant difference in comparison of color specification ($L^*$, $a^*$, $b^*$) values after accelerated aging except $L^*$ value of G-CEM LinkAce (P<0.05). After 24 hours, color difference (${\Delta}E^*$) values were ranged from 2.47 to 3.48 and $L^*$ values decreased and $b^*$ values increased in all types of cement and MaxCem Elite had high color stability (P<0.05). After thermocycling, color change's tendency of cement was varied and color difference (${\Delta}E^*$) values were ranged from 0.82 to 2.87 and G-CEM LinkAce had high color stability (P<0.05). Conclusion: Color stability of dual-cured self-adhesive resin cements after accelerated aging was evaluated and statistically significant color changes occurred within clinically acceptable range.

Evaluation of Marginal and Internal Integrity of Modified Resin-Bonded Fixed Partial Dentures: An In Vitro Study

  • Ahn, Sung-Hyeon;Choi, Jae-Won;Jeon, Yong-Chan;Jeong, Chang-Mo;Yoon, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • 제10권1호
    • /
    • pp.29-34
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the microleakage of various types of resin-bonded fixed partial dentures (RBFPDs) after artificial aging. Materials and Methods: Forty models with missing first molar were fabricated using artificial resin teeth and were divided into four groups: Group A, conventional RBFPDs design; Group B, modified RBFPDs design; Group C, assembled 3-piece RBFPDs design; and Group D, assembled 3-piece RBFPDs with different occlusal rest positions. Half of the specimens underwent chewing simulation process (240,000 cycles, 50 N load, 1.7 Hz) and thermocycling (temperatures $5^{\circ}C{\sim}55^{\circ}C$, dwelling time 30 seconds) and the remaining 20 specimens didn't receive any treatment. All the specimens were immersed in 2% methylene blue solution for 24 hours to evaluate microleakage, and were sectioned at the middle part of abutment teeth. To evaluate the microleaskage, a dye penetration was calculated. Result: With artificial aging, cyclic loading and thermocycling, a 3-piece RBPFD and a 2-piece RBPFD using original tooth undercuts have significantly lower microleakge (P<0.05) compared to the conventional design of RBPFD and modified RBPFD. Conclusion: Within the limit of this experiment, the assembled RBFPDs exhibited a smaller microleakage than the conventional RBFPDs, implying that the assembled RBFPDs can be more effective for reducing the dislodgement of the RBFPDs.

직접 부착법과 간접 부착법이 열순환 후 부착강도와 미세누출에 미치는 영향에 대한 연구 (Effects of direct and indirect bonding techniques on bond strength and microleakage after thermocycling)

  • Ozturk, Firat;Babacan, Hasan;Nalcaci, Ruhi;Kustarci, Alper
    • 대한치과교정학회지
    • /
    • 제39권6호
    • /
    • pp.393-401
    • /
    • 2009
  • 본 연구는 직접 또는 간접 부착법으로 부착한 교정용 브라켓을 열순환 처리 후에 전단 결합 강도(shear bond strength, SBS)와 치아-접착제-브라켓 복합체의 미세 누출을 비교하기 위하여 시행하였다. 50개의 치아우식증이 없는 사람 소구치를 구하여 동등한 2개의 군으로 나누었다. 직접 부착군에서는 광중합 접착제 및 primer (Transbond XT)를 사용하였고 간접 부착군에서는 광중합 접착제와(Transbond XT) 화학중합 primer (Sondhi Rapid Set)를 사용하였다. 중합 후에 치아는 24시간 동안 증류수에 보관하였고 이후 500회 열순환 처리를 하였다. 미세누출의 평가를 위해 각 군에서 10개의 치아에 nail varnish로 추가 봉연을 실시하고 0.5% basic fuchsin에 24시간 동안 염색한 후 입체현미경으로 검경하였다. 만능시험기를 이용하여 각 군의 치아 15개로 SBS를 계측하였고 adhesive remnant index (ARI)를 평가하였다. 결과 자료는 Mann-Whitney U test, Chi-square test, Fisher's exact test로 통계 분석하였다. 직접 부착군과 간접 부착군 사이에 SBS 및 미세누출의 통계적으로 유의한 차이는 보이지 않았으며 간접 부착군에서 통계적으로 유의하게 ARI 점수가 낮았다. 브라켓의 탈락은 법랑질-레진 계면에서 발생하였다. 이상의 결과로 보아 부착법의 차이는 미세누출의 양과 SBS에 유의한 영향을 미치지 않는다.