• Title/Summary/Keyword: thermal variations

Search Result 624, Processing Time 0.028 seconds

Thermal Conductivity Evaluation of Compacted Bentonite Buffers Considering Temperature Variations (압축 벤토나이트 완충재의 온도에 따른 열전도도 평가)

  • Yoon, Seok;Park, Seunghun;Kim, Min-Seop;Kim, Geon-Young;Lee, Seung-Rae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.1
    • /
    • pp.43-49
    • /
    • 2020
  • An engineered barrier system (EBS) for the geological disposal of high-level radioactive waste (HLW) consists of a disposal canister packed with spent fuel, buffer material, backfill material, and gap-filling material. The buffer material fills the space between the canister and the near-field rock, thus serving to restrain the release of radionuclides and protect the canister from groundwater penetration. Furthermore, as significant amounts of heat energy are released from the canister to the surrounding rock, the thermal conductivity of the buffer plays an important role in maintaining the safety of the entire disposal system. Therefore, given the high levels of heat released from disposal canisters, this study measured the thermal conductivities of compacted bentonite buffers from Gyeongju under temperature variations ranging 25 to 80~90℃. There was a 5~20% increase in thermal conductivity as the temperature increased, and the temperature effect increased as the degree of saturation increased.

Bounary Element Analysis of Thermal Stress Intensity Factors for Cusp Cracks (커스프 균열에 대한 열응력세기 계수의 경계요소해석)

  • 이강용;조윤호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.119-129
    • /
    • 1990
  • In case that the body with a cusp crack is under uniform heat flow, thermal stress intensity factors are calculated by using boundary element method with linearized body force term. The crack surface is under insulated or fixed temperature condition and the types of crack are symmetric lip and airfoil cusps. Numerical values of thermal stress intensity factors for a Griffith crack and cusp cracks in infinite bodies are proved to be in good agreement within .+-.5% when compared with the previous numerical and exact solutions, respectively. The thermal stress intensity factors for symmetric lip and airfoil cusp cracks in finite bodies are calculated about various effective crack lengths, configuration parameters, and heat flow directions. With the same crack surface thermal boundary conditions, heat flow directions and crack lengths, there are no appreciable differences in variations of thermal stress intensity factors between symmetric lip and airfoil cusp cracks. The signs of thermal stress intensity factors for each cusp crack are changed with each crack surface thermal boundary condition.

Computation of Equivalent Material Properties of Woven Fabric Composites Using Homogenization Technique (균질화기법을 이용한 WFC의 등가물성치 산출)

  • 이진희;장지현;윤민우
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.10a
    • /
    • pp.1-7
    • /
    • 1997
  • Equivalent thermal conductivities and elasticity properties of woven fabric composites are computed using homogenization technique. The computational results show that the strength and thermal conductivity linearly increase with fiber volume fraction and that the variations of undulation of fibers has little effect on equivalent material properties. Homogenization technique is proved useful in the study of woven fabric composites and may find a lot more applications in the area.

  • PDF

Study on Thermal Behavior of Unidirectional Composite Materials using Embedded Optical Fiber Sensors (삽입되어진 광섬유 센서를 이용한 일방향 적층 복합재료의 열적 거동 연구)

  • 김승택;전흥재;최흥섭
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.251-257
    • /
    • 1999
  • Smart structure that contains sensors, which are either embedded in a composite material or attached to a structure, is currently receiving considerable attention. Fiber Bragg grating sensor, one of the optical fiber sensors, has been widely used to sense strain and temperature for smart structures since both parameters change the resonant frequency of the grating. In this paper, according to the various heating and cooling conditions the thermal behavior of unidirectional composite material was monitored by embedding the fiber Bragg grating sensors in the longitudinal and transverse directions of unidirectional composites. The thermal behavior of unidirectional composite material was monitored for various heating and cooling rates and applied pressure. It was found that the thermal behavior was unaffected by pressure variations and heating and cooling rates applied to the composites. The thermal strains were measured by considering the shift in Bragg wavelength that was generated by the thermal expansion of composite specimen. The longitudinal and transverse C.T.E.'s were also obtained from the corresponding temperature-thermal strain curves.

  • PDF

Study on the application of a realtime simulator to the development of a controller for a space thermal environment chamber (실시간 플랜트 시뮬레이터를 이용한 우주 열환경 챔버 제어기 개발에 관한 연구)

  • Jung, Mu-Jin;Shin, Young-Gy;Choi, Seok-Weon;Moon, Guee-Won;Seo, Hee-Jun;Lee, Sang-Hoon;Cho, Hyok-Jin
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.216-221
    • /
    • 2003
  • A thermal vacuum chamber is mainly used to simulate thermal environments of a test satellite in satellite orbits in which daily temperature variations range from 80K to above 400K depending on solar radiation under the vacuum below $10^{-4}$ torr. The test facility is quite complex and consists of expensive parts. So any modification of control software is discouraged in fear of unexpected system failure. The purpose of this study is to develop a realtime dynamics model of the thermal vacuum chamber in view of controller design and simulate its electrical inputs and outputs for interface with a PLC (programmable logic controller). A PLC program that was used in the thermal vacuum chamber is applied to the realtime simulator. The realized simulator dynamics is found to be quite similar to that of the thermal vacuum chamber and serve to an appropriate plant to verify the control performance of a programmed PLC.

  • PDF

In-situ Measurement Technique for Thermal Performance of Building Wall Excluding Surface Heat Transfer Resistance (표면 열전달 저항이 배제된 건물 벽체 열성능 현장 측정 기법)

  • Kim, Seungchul;Kim, Sangbong;Nah, Hwanseon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.151-155
    • /
    • 2020
  • In this paper, a new experimental method to determine the thermal resistance of building wall was proposed by improving the heat flow method (HFM) based on the air-surface temperature ratio theory. This technique measures the thermal resistance of the wall excluding the inner and outer surface heat transfer resistance. Unlike conventional HFM, this value can be compared directly with the theoretical reference value. Its performance was verified using three mock-up structures with a theoretical thermal transmittance of 0.5, 3.3, and 0.18 W/㎡·K respectively. After measuring the variations in the temperature and heat transfer rate of the mock-ups for 383 hours, the thermal transmittances were determined to be 0.47, 3.10, and 0.18 W/㎡·K, which corresponded to errors of 5.2, 6.2 and 0.5%, respectively, compared to the theoretical values. It was concluded that this technique can directly compare the thermal resistance of the wall between the existent stage and initial stage after construction.

Structural Behavior of Concrete Pavement Due to Temperature Variations (온도변화에 의한 콘크리트 포장도로의 구조 거동 연구)

  • 조병완
    • Computational Structural Engineering
    • /
    • v.4 no.2
    • /
    • pp.95-102
    • /
    • 1991
  • Some sections of concrete highway pavements have been viewed with great concern by highway officials and engineers due to the severe cracking and failure problems. This is mainly due to the traffic loads in addition to temperature variations between top and bottom of concrete slab, which cause the concrete slab to curl up and down depending on the thermal gradient, respectively. Subsequently, a major consideration was given to the derivation of stiffness matrix and equivalent nodal loads due to the uniform gravity load, temperature and shrinkage of concrete. And the structural behavior of concrete highway pavement due to the temperature variations throughout the nations has been emphasized.

  • PDF

HOW TO MONITOR AGN INTRA-DAY VARIABILITY AT 230GHZ

  • Kim, Jae-Young;Trippe, Sascha
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.65-74
    • /
    • 2013
  • We probe the feasibility of high-frequency radio observations of very rapid flux variations in compact active galactic nuclei (AGN). Our study assumes observations at 230GHz with a small 6-meter class observatory, using the SNU Radio Astronomical Observatory (SRAO) as an example. We find that 33 radio-bright sources are observable with signal-to-noise ratios larger than ten. We derive statistical detection limits via exhaustive Monte Carlo simulations assuming (a) periodic, and (b) episodic flaring flux variations on time-scales as small as tens of minutes. We conclude that a wide range of flux variations is observable. This makes high-frequency radio observations-even with small observatories-a powerful probe of AGN intra-day variability; especially, those which complement observations at lower radio frequencies with larger observatories like the Korean VLBI Network (KVN).

Finite Element Analysis of Heat and Moisture Transfer in Porous Materials (다공성 물질의 열 및 습도 전달에 관한 유한요소 해석)

  • Lee, Ho-Rim;Geum, Yeong-Tak;Song, Chang-Seop;O, Geun-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.158-167
    • /
    • 1999
  • Heat and moisture transfer associated with porous materials are investigated. The heat and moisture transfer in porous materials caused by the interaction of moisture gradient, temperature gradient, conduction, and evaporation are considered. The variations of temperature and moisture not only change the volume but also induce the hygro-thermal stress. The finite element formulation for solving the temperature and moisture transfer as well as the associated hygro-thermal stresses is developed. In order to verify the finite element formulation, the heat and moisture moving boundary problem in a half space and the hygro-thermo-mechanical problem in an infinite plate with a circular hole are analyzed. Temperature profile, moisture profile, and hygro-thermal stresses are compared with those of analytic solution and other investigator. Good agreements are examined

  • PDF

V-Factor Estimation Under Thermal and Mechanical Stress for Circumferentially Cracked Cylinder (열하중 및 기계하중이 작용하는 원주 방향 균열 배관에 대한 V-계수 평가)

  • Song, Tae-Kwang;Oh, Chang-Kyun;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1123-1131
    • /
    • 2008
  • This paper provides V-factor estimation under combined mechanical and thermal load for circumferential cracks. Results are based on finite element analyses and effect of types and magnitudes of the thermal stress, crack geometry, the loading mode and plastic strain hardening on variations of the V-factor are investigated. The results of finite element analyses are compared with R6 values. As a result, it is shown that R6 gives generally conservative results. The conservatism is especially increased for the combination of large mechanical and thermal load. As a result, new estimation method which uses failure assessment line in R6 is proposed for V-factor and gives less conservative results.