Abstract
In this paper, a new experimental method to determine the thermal resistance of building wall was proposed by improving the heat flow method (HFM) based on the air-surface temperature ratio theory. This technique measures the thermal resistance of the wall excluding the inner and outer surface heat transfer resistance. Unlike conventional HFM, this value can be compared directly with the theoretical reference value. Its performance was verified using three mock-up structures with a theoretical thermal transmittance of 0.5, 3.3, and 0.18 W/㎡·K respectively. After measuring the variations in the temperature and heat transfer rate of the mock-ups for 383 hours, the thermal transmittances were determined to be 0.47, 3.10, and 0.18 W/㎡·K, which corresponded to errors of 5.2, 6.2 and 0.5%, respectively, compared to the theoretical values. It was concluded that this technique can directly compare the thermal resistance of the wall between the existent stage and initial stage after construction.
Keywords
Heat Flow Method; HFM; Building Energy Efficiency; Building Wall; Thermal Transmittance; Thermal Resistance;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Sutton, R., Stafford, A., Gorse, C., "The Co-heating Test: The value of a number, s.l.": Leeds Metropolitan University, Centre for the Built Environment, 2012.
2 Hens, H. et al., "Brick cavity walls: a performance analysis based on measurements and simulations," Journal of Building Physics, 31(2), pp. 95-124, 2007, https://doi.org/10.1177/1744259107082685.   DOI
3 Remi BOUCHIE, et al., "Methodologies for the Assessment of Intrinsic Energy Performance of Buildings Envelope, Collaborative Project, Call Identifier," FP7-2013-NMP-ENV-EeB, 2015.
4 D. Majcen, L. Itard, H. Visscher, "Theoretical vs: actual energy consumption of labelled dwellings in The Netherlands: discrepancies and policy implications," Energy Policy, 54, pp. 125-136, 2013, https://doi.org/10.1016/j.enpol.2012.11.008   DOI
5 ISO, "ISO 9869-1:2014 - Thermal insulation - Building elements - Insitu measurement of thermal resistance and thermal transmittance - Part 1: Heat flow meter method," 2014.
6 ASTM, "ASTM C1155-95 - Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data," 2013.
7 ASTM, "ASTM C1046-95 - Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components," 2013.
8 허은지, 송두삼, "열판법을 이용한 건물단열성능 현장측정 방법에 관한 연구," 한국건축친환경설비학회 논문집, pp. 185-189, 2012.
9 김서훈, 김종훈, "기존 공동주택의 벽체 열성능 현장 측정법에 관한 연구," 한국생태환경건축학회 논문집, 16(4), pp. 71-77, 2018.
10 노상태, "복수센서를 이용한 외단열 건축물의 외피 열관류율 성능 현장 측정 연구," 한국 건축 친환경설비학회 논문집, 11(1), pp. 58-64, 2017.
11 ISO, "ISO 10456:2007 - Building materials and products - Hygrothermal properties - Tabulated design balues and procedures for determining declared and design thermal values," 2007.
12 고명진, 최두성, "축열교정법에 의한 공동주택 외벽체 동절기 현장 열저항과 열관류율 측정 및 분석," 한국생활환경학회지, 24(6), pp. 802-809, 2017.
13 ISO, "ISO 6946:2017 - Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods," 2017.