• Title/Summary/Keyword: thermal indicator

Search Result 95, Processing Time 0.03 seconds

Micro-Fabrication and Thermal Characteristics of a Thermal Mass Air Flow Sensor for Real-time Applications (고응답 열식 질량공기유량센서의 제작 및 열거동 특성)

  • Park, Byung-Kyu;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.7
    • /
    • pp.542-548
    • /
    • 2008
  • A thermal mass air flow sensor (MAFS), which consists of a micro-heater and thermo-resistive sensors on the silicon-nitride ($Si_3N_4$) thin membrane structure, is micro-fabricated by MEMS processes. Two thermo-resistive temperature sensors are located at $100{\mu}m$ upstream and downstream from the micro-heater respectively. The thermal characteristics are measured to find the best measurement indicator. The micro-heater is operated under constant power condition, and four flow indicators are investigated. The normalized temperature indicator shows good physical meaning and is easy to use in practice. It is found that the configurations and heating power of thermal-resistive elements are the dominant factors to determine the range of the flow measurement in the MAFS with higher sensitivity and accuracy.

A Study on the Precision Engine Indicatior(I) (Zero-shift Compensation of the Engine Indicator with a Electronic Device) (고정도 엔진 지압계에 관한 연구 (1) <온도 특성에 의한 영점이동의 보상>)

  • 박상길;문덕홍;안수길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.34-39
    • /
    • 1983
  • Development of modern internal combustion engine requires more precise indicator. In the case of strain gage-strain tube type indicator, thermal expansion of the indicator's fixed part makes zero-shift in spite of water cooling. Therefore, the authors analyzed the cause of zero-shift phenomenon on strain gage-strain tube type indicator and proposed a new device to compensate the zero-shift of indicator by electrical method without detoriorating the dynamic charcteristic. As the results, we found that the zero-shift is varied linearlly according to temperature variation of the indicator's fixed part and appling a new device, we can improve the zero-shift of indicator about 0.63% (0.63 kg/$cm^2$) of full scale, though we got 10% of it without the device at the cylinder head operating temperature (c.a. $200^{\circ}C$).

  • PDF

Determination of the Dissociation Constant of Thymol Blue with Diode-Laser/Fiber-Optic Thermal Lensing Spectroscopy

  • 김성호;노영순
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.8
    • /
    • pp.822-824
    • /
    • 1998
  • The simple and convenient measurement of the dissociation constant of an indicator, thymol blue, was achieved by using a portable diode-laser/fiber-optic thermal lensing spectroscopy, which consisted of a visible diode laser, a photodiode, and an optical fiber. It gives comparable results to the cited value obtained from a conventional UV/VIS spectroscopy.

Investigation of the required performance to develop a performance-based indicator for balcony window systems in apartment houses (공동주택 발코니 창호의 성능기반지표 개발을 위한 요구성능 조사)

  • Moon, Hyeun-Jun;Ryu, Seung-Ho;Yang, Gi-Young
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.102-107
    • /
    • 2009
  • Window system is an essential component for lighting, ventilation and thermal environment in buildings. Moreover, as balcony extension in apartment houses become legalized, the performance requirements of window systems in balcony space are getting complicated. However, at this moment, five properties of the windows are used to represent the performance aspects of the system, including wind resistance, air tightness, water tightness, sound insulation, thermal resistance. And such single properties are not capable to express the performance of a space with the window systems in terms of performance concept. A performance analysis with wholistic approach is required to see the effect of the window system in built environment. Thus, performance-based approach should be established, which will be able to evaluate the goal/function and comfort of occupants/owners. As the first step to develop the performance indicator for the window systme for balcony space, this study conducts a survey to find the required performance aspects. A complete set of performance-based indicators will be developed with verification methods in the later stage of research.

  • PDF

Development and Application of Korean Thermality Index (KTI) for Biological Assessment on Climate Change (기후변화의 생물학적 평가를 위한 한국온수생물지수(KTI)의 개발 및 적용)

  • Kong, Dongsoo;Kim, Jin-Young;Son, Se-Hwan;Oh, Min Woo;Choi, Ah-Reum;Byeon, Myeong Seop
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.114-126
    • /
    • 2013
  • The purpose of this study was to develop a Korean thermality index (KTI) based on the distribution patterns of benthic macroinvertebrates according to altitude and latitude. Analyzing seasonal data (4,853 sampling units) surveyed and collected during 2007 ~ 2011 at 846 sites in South Korea, we estimated thermal valency, thermal value and indicator weight value of 208 species. Among them, 40 species in 6 orders (Decapoda 1 species, Collembola 1 species, Ephemeroptera 5 species, Plecoptera 17 species, Diptera 3 species, Trichoptera 13 species) were selected as the candidate indicator species sensitive and vulnerable to warmth along with climate change. KTI and Benthic macroinvertebrate index (BMI) were tested at three clean streams (Hangye stream, Buk stream and Bangtae stream). KTI showed significant differences according to altitude and water temperature whereas the saprobity index BMI showed little differences. This result means that KTI can be applicable to assess the impact of water temperature independently of organic pollutants.

Evaluation of Erythrocyte Morphometric Indices in Juvenile Red Spotted Grouper, Epinephelus akaara under Elevated Water Temperature

  • Rahman, Md Mofizur;Baek, Hea Ja
    • Development and Reproduction
    • /
    • v.23 no.4
    • /
    • pp.345-353
    • /
    • 2019
  • Higher thermal exposure can influence the blood cell morphology and count. Hence, based on the previous results (Rahman et al., 2019), the present study evaluated the morphometric indices of erythrocytes and their nucleus under different water temperatures (25℃, 28℃, 31℃, and 34℃) to investigate their use as an indicator of thermal stress in red spotted grouper, Epinephelus akaara. 180 healthy specimens of E. akaara were exposed to four temperature conditions (25℃ as control, 28℃, 31℃, and 34℃) for 42 days, following 2 weeks of acclimation at 25℃. Erythrocyte major axis (EL), erythrocyte minor axis (EW), nucleus major axis (NL), and nucleus minor axis (NW) were examined from the blood smears on each sampling day (i.e., 2, 7, and 42 days of thermal exposure). EL and NL were significantly decreased, whereas EW and NW were increased at higher water temperature (31℃ and 34℃). The major-minor axis proportions of erythrocytes and their nucleus (EL/EW; NL/NW) were decreased with increasing water temperature (31℃ and 34℃). The strong relationships were observed among the morphometric indices of erythrocytes and their nucleus, especially in EL vs. NL and EW vs. NW. This study reveals that elevated water temperature (31℃ and 34℃) can influence the major and minor axis morphometry of erythrocytes and their nucleus in red spotted grouper. These indices may be used as stress indicators to monitor the health status of E. akaara and probably for other fish species.

Effect of Thermal Discharge from Semiconductor Factory into Stream on Freshwater Fish

  • Je-Bin Yu;Sun-Jib Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.2
    • /
    • pp.375-380
    • /
    • 2023
  • The study was conducted in Manu-stream, located in Paju, Gyeonggi-do, from January 2021 to December 2021. The survey points were selected in the upper and lower streams based on where thermal discharged to investigate water temperature and fish species and biological community analysis and growth rate were analyzed. The average annual water temperature difference between the upper and lower stream is about 11.0℃, and in the case of the lower stream area, the water temperature is maintained at 20.0℃ or more per year. Fish that appeared during the survey period decreased lower stream compared to the upper stream, which is believed to be the result of a decrease in temperature-sensitive species as the simple riverbed structure and water temperature increased compared to the upper stream. As a result of biological community analysis, it showed a relatively stable community state at the upper stream. The growth rate of fish has a high regression coefficient b value in lower streams throughout the four seasons. It showed relatively good growth lower stream, with a high water temperature. However, the results of each survey point are similar from season to season. The indicator species is a resistant intermediate species, and the range of resistance to water temperature is wide, so it is judged that water temperature's effect on the indicator species' growth is low.

Evaluation of Degradation Characteristics of Thermal Barrier Coating on Gas Turbine Blades

  • Jung, Yongchan;Kim, Mintae;Lee, Juhyeung;Ahn, Jamin;Kim, Kihong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.273-278
    • /
    • 2016
  • In order to evaluate the lifespan of high-temperature parts with thermal barrier coating in gas turbines used for power generation, this study was performed on an 80 MW-class gas turbine exceeding 24 k equivalent operating hours. Degradation characteristics were evaluated by analyzing the YSZ (Yttria Stabilized Zirconia) top coat, which serves as the thermal barrier coating layer, the NiCrAlY bond coat, and interface layers. Microstructural analysis of the top, middle, and bottom sections showed that Thermal Growth Oxide (TGO) growth, Cr precipitate growth within the bond coat layer, and formation of diffusion layer occur actively in high-temperature sections. These microstructural changes were consistent with damaged areas of the thermal barrier coating layer observed at the surface of the used blade. The distribution of Cr precipitates within the bond coat layer, in addition to the thickness of TGO, is regarded as a key indicator in the evaluation of degradation characteristics.

Measurements of Thermal Characteristics for a Micro-Fabricated Thermal Mass Air Flow Sensor With Real-Time Controller (실시간 제어기를 이용한 마이크로 열식 질량공기 유량센서의 열특성 측정)

  • Park, Byung-Kyu;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.8
    • /
    • pp.573-579
    • /
    • 2009
  • A thermal mass air flow sensor, which consists of a micro-heater and thermal sensors on the silicon-nitride thin membrane structure, is micro-fabricated by MEMS processes. Three thermo-resistive sensors, one for the measurement of microheater temperature, the others for the measurement of membrane temperature upstream and downstream of the micro-heater respectively, are used. The micro-heater is operated under the constant temperature difference mode via a real time controller, based on inlet air temperature. Two design models for microfabricated flow sensor are compared with experimental results and confirmed their applicabilities and limitations. The thermal characteristics are measured to find the best flow indicator. It is found that two normalized temperature indicators can be adopted with some advantages in practice. The flow sensor with this control mode can be adopted for wide capability of high speed and sensitivity in the very low and medium velocity ranges.