• Title/Summary/Keyword: thermal imaging

Search Result 615, Processing Time 0.023 seconds

Real Time Image Processing of Thermal Imaging System (열상장비의 실시간 영상 신호처리)

  • Hong Seok Min;Yu Wee Kyung;Yoon Eun Suk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.79-86
    • /
    • 2004
  • This paper has presented to the design results of the analog and digital signal processor for the 2nd generation thermal imaging system using $480\times6$ infrared focal plane array In order to correct non-uniformities of detector arrays, we have developed the 2-point correction method using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we developed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained a high qualify thermal image and acquired good result.

Visible Light and Infrared Thermal Image Registration Method Using Homography Transformation (호모그래피 변환을 이용한 가시광 및 적외선 열화상 영상 정합)

  • Lee, Sang-Hyeop;Park, Jang-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.707-713
    • /
    • 2021
  • Symptoms of foot-and-mouth disease include fever and drooling a lot around the hoof, blisters in the mouth, poor appetite, blisters around the hoof, and blisters around the hoof. Research is underway on smart barns that remotely manage these symptoms through cameras. Visible light cameras can measure the condition of livestock such as blisters, but cannot measure body temperature. On the other hand, infrared thermal imaging cameras can measure body temperature, but it is difficult to measure the condition of livestock. In this paper, we propose an object detection system using deep learning-based livestock detection using visible and infrared thermal imaging composite camera modules for preemptive response

Special Issue for Biomedical Ultrasound: Towards Further Advances in Fundamentals and Applications by Comprehensive Reviews

  • Kim, Yong-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.3E
    • /
    • pp.107-110
    • /
    • 2010
  • In this paper, the rationale and contents of the special issue of the Journal of the Acoustical Society of Korea regarding comprehensive reviews on past, present and future of biomedical ultrasound are described. Brief descriptions of invited articles are given, and efforts by all contributing authors are gratefully acknowledged.

Seperate Driving System For Large Area X-ray Detector In Radiology (대면적 X-ray 검출기를 위한 분할 구동 시스템)

  • Lee, D.G.;Park, J.K.;Kim, D.H.;Nam, S.H.;Ahn, S.H.;Park, H.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.388-391
    • /
    • 2003
  • The properties of these detectors can be controlled by electronics and exposure conditions. Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors gain more interest real time medical x-ray imaging. Active area of flat panel detector is $14{\times}17$ inch. Detector is based on a $2560{\times}3072$ away of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with a 500m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(5%) of thermal deposition system. Each $139m{\times}139m$ pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to 4.2 second per frame. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system..

  • PDF

A Review of the Domestic Study Trends on Obstetrics & Gynecological Diseases by Using Digital Infrared Thermal Imaging as a Diagnosis Instrument (한방여성의학 영역에서 진단 도구로 적외선 체열 검사(Digital Infrared Thermal Imaging, DITI)를 활용한 국내 연구 동향 분석)

  • Im, Ji-Yeong;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.33 no.3
    • /
    • pp.80-94
    • /
    • 2020
  • Objectives: The purpose of this review is to analyze the domestic study trends of clinical use of Digital Infrared Thermal Imaging (DITI) as a diagnosis instrument on obstetrics and gynecological diseases in Korean literature. Methods: We searched for clinical studies using DITI in the journal of Korean obstetrics & gynecology, National Digital Science Library, Research Information Sharing Service, Korean Medical Database up to May 2020. After searching studies, we selected studies and analyzed according to disease. Results: 18 clinical studies were published in two kinds of academic journals. There were 4 studies about dysmenorrhea and menopausal symptoms, 2 studies about postpartum disease and hypercryalgesia, 1 study about amenorrhea, premenstrual syndrome, leukorrhea, infertility, polycystic ovary syndrome and hot flush. Conception vessel was frequently used for DITI measurement, followed by stomach meridian. The temperatures of abdomen (CV4, CV12), face (HN3), upper and lower limb (PC8, LU4, LR3, ST32) were commonly measured. Conclusions: This study shows that DITI could be one of effective diagnosis instrument for obstetrics and gynecological diseases. More well-designed clinical studies using DITI will be needed.

Alteration in Infrared Thermal Imaging by Use of Acupuncture-like Electric Stimulation on Finger Control Gate (체열촬영으로 관찰한 전기수지자극의 효과)

  • Lee, Sang-Hun;Lee, Kyu-Chang;Woo, Nam-Sik;Lee, Ye-Chul;Kim, Sun-Bok;Lee, Hyung-Hoan
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.222-230
    • /
    • 1994
  • Acupuncture-like transcutaneous electrical nerve stimulation(ALTENS) on acupuncture site(dorsal and ventral side of finger) were compared with a placebo site(forearm) by infrared thermal imaging. Six disease-free volunteers underwent, on different days, an ALTENS treatment and a placebo treatment in a cross-over sequences of stimulation control and inhibition control in excess of 50 treatments. ALTENS treatments were given at 30Hz at an intensity just below pain threshold delivered to acupuncture points on fingers. Placebo stimulations were administered in similar manner. After every thirty minutes of ALTENS and placebo treatment with stimulation, inhibition control sequence and vice versa, we examined whole body infrared thermal imaging and checked changed skin temperature on frontal, anterior chest, upper and lower abdomen, dorsal and ventral aspect of hand, thoracic and lumbar area, anterior and posterior aspect of lower leg. There were significant skin temperature elevations with ALTENS treatment, especially finger control gate corresponding organ area. Placebo treatment revealed no skin temperature change. We concluded that ALTENS on finger control gate influence physiologic state as opposed to conventional electric stimulation.

  • PDF

Thermal Imaging Camera Development for Automobiles using Detail Enhancement Technique (디테일 향상 기법을 적용한 자동차용 열상카메라 개발)

  • Cho, Deog-Sang;Yang, In-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.687-692
    • /
    • 2018
  • In this paper, the development of an automotive thermal imaging camera providing image information for ADAS (Advanced Driver Assist System) and autonomous vehicles is described and an improved technique to enhance the details of the image is proposed. Thermal imaging cameras are used in various fields, such as the medical, industrial and military fields, for the purpose of temperature measurement and night vision. In automobiles, they are utilized for night vision systems. For their utilization in ADAS and autonomous vehicles, appropriate image resolution and enhanced detail are required for object recognition. In this study, a $640{\times}480$ resolution thermal imaging camera that can be applied to automobiles is developed and the BDE (Block-Range Detail Enhancement) technique is applied to improve the details of the image. In order to improve the image detail obtained in various driving environments, the block-range values between the target pixel and the surrounding 8 pixels are calculated and classified into 5 levels. Then, different factors are added or subtracted to obtain images with high utilization. The improved technique distinguishes the dark part of the image by the resulting temperature difference of 130mK and shows an improvement in the fine detail in both the bright and dark parts of the image. The developed thermal imaging camera using the improved detail enhancement technique is applied to a test vehicle and the results are presented.

Usefulness of cyclic thermal therapy and red blood cell scintigraphy in patients with chemotherapy-induced peripheral neuropathy

  • Kim, Minjoo;Kim, Eun-Mi;Oh, Phil-Sun;Lim, Seok Tae;Sohn, Myung-Hee;Song, Eun-Kee;Park, Keon Uk;Kim, Jin Young;Won, Kyoung Sook;Jeong, Hwan-Jeong
    • The Korean Journal of Pain
    • /
    • v.34 no.4
    • /
    • pp.427-436
    • /
    • 2021
  • Background: Pharmacological and non-pharmacological therapies have been used to treat patients with chemotherapy-induced peripheral neuropathy (CIPN). However, the effect of therapies in cancer patients has yet to be investigated comprehensively. We hypothesized that cyclic thermal therapy would improve blood flow and microcirculation and improve the symptoms driven by CIPN. Methods: The criteria of assessment were blood volume in region of interest (ROI) in the images, and European Organization for Research and Treatment of Cancer-Quality of Life Questionnaire-Chemotherapy-Induced Peripheral Neuropathy 20 questionnaire scores. The blood volume was quantified by using red blood cell (RBC) scintigraphy. All patients were treated 10 times during 10 days. The thermal stimulations, between 15° and 41°, were repeatedly delivered to the patient's hands. Results: The total score of the questionnaires, the score of questions related to the upper limbs, the score of questions closely related to the upper limbs, and the score excluding the upper limbs questions was decreased. The blood volume was decreased, and the variance of blood volume was decreased. During cooling stimulation, the blood volume was decreased, and its variance was decreased. During warming stimulation, the blood volume was decreased, and its variance was decreased. Conclusions: We suggest that cyclic thermal therapy is useful to alleviate CIPN symptoms by blood circulation improvement. RBC scintigraphy can provide the quantitative information on blood volume under certain conditions such as stress, as well as rest, in peripheral tissue.

Ghost Imaging with Different Speckle Sizes of Thermal Light

  • Jue, Wang;Renlong, Yu;Yu, Xin;Yanming, Shao;Yanru, Chen;Qi, Zhao
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.8-12
    • /
    • 2016
  • In this paper, we theoretically and experimentally analyze the impact of speckle size of pseudo-thermal light source on ghost imaging. A larger size of speckle can bring improvements in SNR and visibility. At the same time, the edge blur of the retrieved image will become more serious. We also present a setup which can mitigate the edge blur of larger speckle while maintaining the advantages of higher SNR and visibility by changing the speckle size of the object beam with a concave lens.