• Title/Summary/Keyword: thermal environment

Search Result 2,972, Processing Time 0.028 seconds

Calculation of Thermal Conductivity and Heat Capacity from Physical Data for Some Representative Soils of Korea

  • Aydin, Mehmet;Jung, Yeong-Sang;Lee, Hyun-Il;Kim, Kyung-Dae;Yang, Jae-E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The thermal properties including volumetric heat capacity, thermal conductivity, thermal diffusivity, and diurnal and annual damping depths of 10 representative soil series of Korea were calculated using some measurable soil parameters based on the Taxonomical Classification of Korean Soils. The heat capacity of soils demonstrated a linear function of water content and ranged from 0.2 to $0.8cal\;cm^{-3}^{\circ}C^{-1}$ for dry and saturated medium-textured soil, respectively. A small increase in water content of the dry soils caused a sharp increase in thermal conductivity. Upon further increases in water content, the conductivity increased ever more gradually and reached to a maximum value at saturation. The transition from low to high thermal conductivity occurred at low water content in the soils with coarse texture, and at high water content in the other textures. Thermal conductivity ranged between $0.37{\times}10^{-3}cal\;cm^{-1}s^{-1}^{\circ}C^{-1}$ for dry (medium-textured) soil and $4.01{\times}10^{-3}cal\;cm^{-1}s^{-1}^{\circ}C^{-1}$ for saturated (medium/coarse-textured) soil. The thermal diffusivity initially increased rapidly with small increases in water content of the soils, and then decreased upon further increases in the soil-water content. Even in an extreme soil with the highest diffusivity value ($1.1{\times}10^{-2}cm^2s^{-1}$), the daily temperature variation did not penetrate below 70 cm soil depth and the yearly variation not below 13.4 m as four times of damping depths.

A Study on Green Space Management Planning Considering Urban Thermal Environment (도시 열환경을 고려한 녹지관리방안 수립 연구)

  • Joo, Chang-Hun;Kim, Jeong-Ho;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1349-1358
    • /
    • 2014
  • This study suggests plan of green space management based on the result of research apprehending the characteristic through sorting types of city thermal environment targeting summer which thermal pollution is the most serious. Considering anthropogenic heat, development level of wind road, thermal environment, as a result of types of thermal environment process, it is appeared 36 types, and 10 types is relevant of this research subject. Type I-1, size of building is large, artificial covering area is wide, and thermal load of anthropogenic heat is high, type II-1, development condition of wind road is incomplete as IIlevel, entering cold air is difficult and thermal management and improvement is needed area. Type III-1, scale is large and it is area of origin of cold air, development level of wind road is mostly favorable, type III-2 is revealed as smaller scale than III-1, and small area of origin of cold air. Type IV, anthropogenic heat is $81{\sim}150W/m^2$, average, but development function of wind road is very favorable. Type V, large area of thermal load and the origin of cold air are distributed as similar ratio, and level of development function of wind road is revealed as II level. According to standard of type classification of thermal environment, as a result of suggesting plan of green space management and biotops area ratio, type I-1 is buffer green space and waterway creation, goal biotops area ratio 35%, type II-1 afforestation in site and goal biotops area ratio 40%, type III-1, preservation plan to display the current function continuously is requested. Type IV suggests afforestation of stream current, and type V suggests quantitative increase of green space and goal biotops area ratio 45%.

A Study on Examination of Indoor Thermal Environment Elements and Thermal Sensation Vote of Log Cabins in Winter Season (통나무집의 동절기 실내 온열환경 요소의 측정과 온열감 평가에 관한 연구)

  • Min, Byeong-Cheol;Jeon, Ji-Hyeon;Kook, Chan
    • Journal of the Korean housing association
    • /
    • v.18 no.2
    • /
    • pp.21-27
    • /
    • 2007
  • Various buildings constructed by environmentally friendly resources are being built in KOREA. Especially as the wood has distinctive ecological merits in comparison with reinforced concrete and brick, the buildings made by the wood are acknowledged with its superiority of ecological value. Enough field studies for their thermal environment, however, haven't been done. In this study, to investigate indoor environmental condition and occupants' response to it of Log Cabin in Gyeongsangnam-do Hamyang Country Jirisan Natural Recreation Forest, examination of indoor thermal environment and field subjective evaluation have been done in that fundamental information of thermal environment characteristics can be suggested. The results are following; 1) Thermal environment of the Log Cabins; Indoor and outdoor mean dry bulb temperature were $21.9^{\circ}C$ and $-3.1^{\circ}C$, and Indoor and outdoor average relative humidity were 25.8% and 52.1%. These results are below ASHRAE; dry bulb temp. $22.0^{\circ}C$, humidity 30%, and above domestic standards; dry bulb temp. $18{\sim}20.0^{\circ}C$, humidity $40{\sim}60%$. 2) Result of subjective evaluation; Thermal sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. And humid sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. 3) Result of vertical temperature and humidity; Vertical temperature difference from head to ankle was $0.54^{\circ}C$ which means most occupants may feel comfortable.

Measurement of Micro Thermal Deformation of Optical Pick-up Base Using Holographic Interferometry (흘로그램 간섭계를 이용한 광픽업 베이스의 미소 열변형 측정)

  • 서영민;강신일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.191-194
    • /
    • 2002
  • In optical pick-up, optical components such as objective lens, collimator, mirror, laser diode and photo diode are mounted on the pick-up base. These components must keep their original position during operation for proper transmittance of information from laser diode to optical disk and back to photo diode. However, micro thermal deformation of pick-up base which is induced by thermal environment during operation can deteriorate the performance of optical pick-up. Therefore, it is important to measure and analyze the thermal deformation behavior of pick-up base under thermal environment. In the present study, a measurement system using holographic interferometry was designed to measure micro thermal deformation of pick up base. The measurement system was verified by using the deformation of cantilever with prescribed motion actuated by PZT with 1 nm resolution. Interferometric measurement was compared quantitatively with that induced by PZT actuator. Finally, micro thermal deformation of pick-up base under actual thermal environment was measured using the present holographic interferometry and the results were analysed.

  • PDF

Thermal Analysis of Electronic Devices in an Onboard Unit Considering Thermal Conduction Environment (열전도 환경을 고려한 전장탑재물의 소자 열 해석)

  • Kim Joon-Yun;Kim Bo-Gwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.5 s.311
    • /
    • pp.60-67
    • /
    • 2006
  • Thermal analysis and prediction of electronic components is required to predict and optimize the reliability of onboard electronic unit employed in space vehicles. This paper introduces a methodology on thermal prediction that uses isothermal PCB model, thermal force model, thermal resistance matrix and superposition principle to calculate electronic devices temperatures undergoing thermal conduction environment. An example is Presented including a prediction result by this method and simulation results performed by commercial program.

Oxidative stress status and reproductive performance of sows during gestation and lactation under different thermal environments

  • Zhao, Yan;Kim, Sung Woo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.5
    • /
    • pp.722-731
    • /
    • 2020
  • Objective: Two experiments were conducted using 28 healthy multiparous sows to evaluate the oxidative stress status and reproductive performance of sows during gestation and lactation under different thermal environments. Methods: Fourteen multiparous sows were used in Exp. 1 under a high thermal environment, and the other 14 multiparous sows were used in Exp. 2 under a moderate thermal environment. In both experiments, reproductive performances of sows were recorded. Plasma samples were collected on d 35, 60, 90, and 109 of gestation, and d 1 and 18 of lactation for malondialdehyde, protein carbonyls, 8-hydroxy-deoxyguanosine, immunoglobulin g (IgG), and IgM analysis. Results: For sows in Exp. 1, plasma malondialdehyde concentration on d 109 of gestation tended to be greater (p<0.05) than it on d 18 of lactation. Plasma concentration of protein carbonyl on d 109 of gestation was the greatest (p<0.05) compared with all the other days. Plasma concentrations of 8-hydroxy-deoxyguanosine on d 109 of gestation was greater (p<0.05) than d 18 of lactation in Exp. 1. For sows in Exp. 2, there was no difference of malondialdehyde and protein carbonyl concentration during gestation and lactation. In both Exp. 1 and 2, litter size and litter weight were found to be negatively correlated with oxidative stress indicators. Conclusion: Sows under a high thermal environment had increased oxidative stress during late gestation indicating that increased oxidative damage to lipid, protein, and DNA could be one of the contributing factors for reduced reproductive performance of sows in this environment. This study indicates the importance of providing a moderate thermal environment to gestating and lactating sows to minimize the increase of oxidative stress during late gestation which can impair reproductive outcomes.

Effect of an Urban Thermal Environment on the Air Quality in Two Cities

  • Lee, Kwi-Ok;Lee, Hwa-Woon;Lee, Hyun-Ju;Park, Jong-Kil;Jung, Woo-Sik
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.29-40
    • /
    • 2011
  • In this study, the effects of an urban thermal environment on air quality were investigated using hourly surface weather observation data and air quality data over six summers from 2000 to 2005 in two cities on the Korean Peninsula. One, the city of Daegu, is representative of basin topography and the other, the city of Busan, represents a coastal area. It is known that the characteristics of an urban thermal environment are represented as an "urban heat island". Here, we focus on the nighttime urban thermal environment, which is called a "tropical night", during the summer. On tropical nights in Busan, the temperature and cloud cover levels were higher than on non-tropical nights. Wind speed did not appear to make a difference even on a tropical night. However, the frequency of southwestern winds from the sea was higher during tropical nights. The prevailing southwest winds in all areas meant an inflow of air from the sea. So at most of the air quality stations, the ozone concentration during tropical nights was lower than during non-tropical nights. In Daegu, the tropical nights had higher temperatures and cloud covers. Despite these higher temperatures, the ozone concentration during the tropical nights was lower than that on non-tropical nights at most of the air quality stations. This feature was caused by low irradiance, which in turn caused an increased cloud cover. Wind speed was stronger during the tropical nights and dispersed the air pollutants. These meteorological characteristics of the tropical nights reduced ozone concentrations in the Daegu Basin.

A Study on the Improvement of Indoor Thermal and Air Environment Made by Ceiling Cassette Type Cooling and Heating Unit in Classrooms (천장 카세트형 냉·난방기에 의해 형성되는 학교 교실의 실내 열환경 및 공기환경의 개선에 대한 연구)

  • Chang, Hyun-Jae;Lee, Ha-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.141-148
    • /
    • 2012
  • Ceiling cassette type air conditioner has been a main stream as a heating/cooling system recently in school, Korea. In this study, indoor thermal environments made by ceiling cassette type air conditioner were investigated by CFD simulation. Concentrations of $CO_2$ were investigated by a field measurement. Indoor thermal environment with the velocity inlet angle of $45^{\circ}$ from the ceiling in heating season was very ununiform so that thermal area was divided into two parts those the one is window side which is cold, and the other is corridor side which is hot. In cooling season under the same condition, there are areas too hot or too cold. If the velocity inlet angle is set in $30^{\circ}$ from the ceiling, indoor thermal environments was improved greatly in cooling season and heating season, too. Also, from the field measurement of $CO_2$ concentrations, it was suggested to install ventilators with proper air volume considered the number of class students.

Wood Thermal Conductivity Database Construction for the Application of Building Energy Simulation (건축물 에너지 시뮬레이션 적용을 위한 목재 열전도율 데이터베이스 구축)

  • Seo, Jungki;Kang, Yujin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.27 no.2
    • /
    • pp.122-127
    • /
    • 2016
  • The increasing interest in the environment and climate change around the globe, while the importance of building energy saving is increasing. The building energy simulation program is used for evaluating of energy performance of buildings. However, an input value of wood thermal conductivity in the programs is different from each other. Therefore, in this study, wood thermal conductivity was measured according to species. Through construction database by species of wood, the error of simulation program are able be decreased. In addition, if used as a structural and interior of buildings, the thermal conductivity and moisture of the wood is difficult to apply to the program because they were changed according to the occupant's lifestyle. In this paper, thermal conductivity and moisture content.of wood confirmed changes in the constant temperature and relative humidity ($25^{\circ}C$, 50% R.H.) condition.

Analysis of Skin Temperature and Body Movements depend on the Thermal Environment during sleep (수면시 온열환경에 따른 피부온도 및 신체움직임 분석)

  • 임은숙;금종수;이기섭;조관식;배동석;김동규;최광환;최호선
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.3-6
    • /
    • 1999
  • There are numerous studies on relations between sleep and environmental factors such as noise, illumination and thermal conditions. Sleep is affected by the thermal environment. This study describes influence of thermal environment on skin temperature, sleep patterns and body movements using physiological and psychological measurements. The results are as follows: 1) The fluctuations of room temperature during sleep appeared skin temperature variations. The more room temperature is high, the more skin temperature is high in 22$^{\circ}C$, 26$^{\circ}C$, 30$^{\circ}C$. 2) A significant relation between body movement and skin temperature was found within room temperature. Under room temperature conditions of 22$^{\circ}C$, 26$^{\circ}C$, 30$^{\circ}C$, there were significantly higher rates of body movement in the room temperature(30$^{\circ}C$). 3) Uncomfortable after sleep in thermal environment is mostly under high temperature(30$^{\circ}C$), and they are about fatigue due to not enough sleeping. 4) The degree of indoor thermal temperature with sufficient sleeping is in 22.8 ∼ 27.8$^{\circ}C$.

  • PDF