• 제목/요약/키워드: thermal circuit

검색결과 655건 처리시간 0.026초

태양열 축열조가 없는 변유량 제어 방식의 지역난방용 태양열시스템 실증시험연구 (The Development of the Climatic Design Tool for Energy Efficient Building Design)

  • 백남춘;신우철;이진국;윤응상;윤석만
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.21-27
    • /
    • 2008
  • In this study, the design of the solar heating system for district heating as well as it's operating characteristics and the performance analysis was carried out. This solar district heating system was composed of two different types of solar collector circuit, flat plate and vacuum tube solar collector, in a system. This system supply constant temperature of hot water without solar buffer tank. For this, the proportional(variable flow rate) control was used. The experimental facility for this study was used the Bundang district solar heating system which was installed in the end of 2006. The operating characteristics and behaviour of each collector circuits are investigated especially for the system design and control. The yearly solar thermal efficiency is 47.5% on the basis of aperture area and 39.8% on the basis of gross area of collector. As a result this solar heating system without solar buffer tank and with proportional controller was testified a very effective and simplified system for district heating. It varied especially depend on the weather condition like as solar radiation and ambient temperature.

방화구획 완화에 따른 PCB공장의 화재위험평가 및 스프링클러 요구살수유량 산정을 통한 기준개선안에 관한 연구 (A Study on a PCB Manufacturing Plant's Fire Risk Assessment due to the Mitigation of Fire Protection Zone and an Improvement Way through Estimation of Sprinkler Demand Water Flow Rate)

  • 오찬욱;오륜석;최준호
    • 한국화재소방학회논문지
    • /
    • 제33권2호
    • /
    • pp.56-62
    • /
    • 2019
  • 스프링클러는 방호구역에 설치된 감지기 또는 헤드가 화재를 감지하여 자동으로 화재를 진압하는 소화설비로 화재 초기에 뛰어난 소화효과가 있어 폭넓게 설치되고 있다. 하지만 국토교통부의 "건축물의 피난 방화구조 기준 등에 관한 규칙"에는 공장 또는 창고의 경우 스프링클러설비를 설치하면 방화구획을 3배까지 완화해 줄 수 있도록 그 근거를 제공하고 있다. 이에 본 연구에서는 스프링클러설비 설치로 방화구획을 완화한 실제 Printed Circuit Board (PCB) 공장 1개소를 대상으로 화재위험성을 분석하였고, 컴퓨터 시뮬레이션을 통한 스프링클러설비의 헤드 개방 특성 및 스프링클러 설비의 설치기준, 감열성능, 작동범위, 방수량 등을 분석하였다. 또한 이를 통해 화재 시 스프링클러 설비 작동의 문제점을 확인하고, 제도 개선을 위한 요구 살수유량 등 근거를 제시하고자 한다.

다양한 레이저 조건에 따른 컷팅셀 제작 및 특성 분석 (Fabrication and Chracteristics of Cutting Cell with Various Laser Conditions)

  • 박정은;김동식;최원석;장재준;임동건
    • 한국태양에너지학회 논문집
    • /
    • 제39권3호
    • /
    • pp.9-17
    • /
    • 2019
  • Laser cutting cell of solar cells can achieve high voltage and efficiency through more array than conventional 6 inch cell compared to same area. In this study, we fabricated c-Si cutting cell with various lasers and laser conditions such as power, speed, and number of times. In the case of picosecond laser, excellent surface characteristics were obtained due to small surface defects and low thermal damage at the output of 20W and the speed of 100 mm/s. However, it is not possible to fabricate a cutting cell having good characteristics due to nonuniform cutting inside the wafer when the processing for forming a cutting cell is not sufficiently performed. For nanosecond lasers, the best wafer characteristics were obtained for fabrication of excellent cutting cells at a frequency of 500 kHz and a laser speed of 100 mm/s. However, the nanosecond laser has not been processed sufficiently in the condition of a number of times. As a result, it was confirmed that the wafer thickness was cut by $63{\mu}m$ of the cell thickness of $170{\mu}m$ in the condition of five times of laser process. It was found that more than 30% of the wafer thickness had to be processed to fabricate the cutting cell. After cutting the 6-inch cell having the voltage of 0.65 V, we obtained the voltage of about 0.63 V.

수동형 압전션트를 이용한 외팔보의 진동저감 연구 (Vibration Reduction of Cantilever using Passive Piezoelectric Shunt)

  • 윤양수;김재철;노희민
    • 한국도시철도학회논문집
    • /
    • 제6권4호
    • /
    • pp.417-426
    • /
    • 2018
  • 압전션트는 구조물의 진동을 저감할 수 있는 전기적인 형태의 댐퍼이다. 구조물의 고유진동수에서 발생한 진동은 구조물에 부착된 압전재료를 통해 전기에너지로 변환된다. 전기에너지는 인덕터와 저항으로 구성된 압전션트를 이용하여 열에너지로 소산시켜 진동을 저감할 수 있다. 본 논문에서는 외팔보의 진동을 저감하기 위하여 필요한 최적 인덕턴스에 대한 수식을 검토하고 유한요소해석과 실험을 이용하여 알루미늄 외팔보의 진동을 저감하였다. 유한요소해석에서는 모드형상과 스트레인에너지 분포를 계산하여 부착위치를 검토하고, 인덕턴스와 저항의 회로값을 조절하여 외팔보의 진동저감량을 계산하였다. 또한, 실험에서는 가변인덕터 모듈을 사용하여 외팔보의 특정주파수에서 발생하는 진동을 저감하였다. 결국, 유한요소해석과 실험의 결과를 토대로 압전션트가 외팔보의 진동을 효과적으로 저감할 수 있음을 검증하였다.

저주파수대의 원자로 출력신호 점검을 위한 대수 카운트레이트 회로 (Log Count Rate Circuits for Checking Electronic Cards in Low Frequency Band Reactor Power Monitoring)

  • 김종호;최규식
    • 한국항행학회논문지
    • /
    • 제24권6호
    • /
    • pp.557-565
    • /
    • 2020
  • 원자로의 출력신호를 감시하는 노외중성자속감시계통의 열화상태를 점검하기 위해서는 원자로에서 방출되는 중성자 펄스를 감지하여 처리하는 전자카드에서 주파수형태로 감지하여 전압으로 변환한 후 대수 형태의 직류전압 값을 얻는 방법을 이용한다. 실제로 원전에서 적용하는 방법으로서는 주파수 카운터와 flip-flop 조합으로 이 과정을 수행하거나, 또는 다이오드펌프와 캐패시터의 조합을 이용하는 방법을 쓰며, 아직도 이 방법이 일반적으로 쓰이고 있다. 이 방법들은 높은 주파수에서는 신뢰성이 높으나 낮은 주파수에는 오차가 크고 측정시간도 오래 걸린다는 문제점이 있다. 따라서 본 연구에서는 고출력대의 고주파수 범위뿐만 아니라 중위출력 범위 주파수대, 그리고 극히 저출력 범위에 속해 있는 취약주파수대인 0.21 Hz~2 kHz 범위의 낮은 주파수대에 이르는 광범위한 주파수를 대수직류전압으로 신뢰성 높게 변환시킬 수 있는 장치를 개발하였다. 개발된 선택회로의 신뢰성을 확인하기 위하여 원전에서 사용되는 실제의 데이터값을 적용하여 테스트하였으며, 그 결과를 분석하여 선택회로의 정당성을 입증하였다.

전기차용 7kW급 고전압 히터 유로 형상 설계를 위한 열유동 시뮬레이션 (Thermo-Fluid Simulation for Flow Channel Design of 7kW High-Voltage Heater for Electric Vehicles)

  • 손권중
    • 한국융합학회논문지
    • /
    • 제13권3호
    • /
    • pp.191-196
    • /
    • 2022
  • 내연기관 자동차 히터는 연소과정 중에 발생하는 엔진 열을 이용하므로 열원이 추가로 필요치 않지만, 배터리로부터 동력원을 얻는 전기자동차용 히터는 별도의 전열 장치가 요구된다. 지금까지 개발된 전기차용 히터 중에서 냉매를 이용하는 고전압 히터는 효율이 높고 작동 온도 범위가 넓은 장점이 있다. 고전압 히터 내부의 냉각수 유로의 형상은 열교환 성능을 크게 좌우하므로 히터 개발 시 유로 설계는 기술적으로 매우 중요하다. 본 논문에서는 대칭형 서펜타인 유로를 갖는 7kW급 고전압 히터의 유로 형상 설계를 위해 고전압 열유동 시뮬레이션을 수행하였다. 해석결과로부터 입출구간 차압과 차온 및 유로에서의 유동 균일도를 계산하여 히터의 성능을 평가하였다. 도출된 대칭형 서펜타인 유로 설계안은 기존 평행 서펜타인 비해 차압은 높지만, 열교환 성능은 비등하며 저온부가 비교적 넓게 존재하여 제어 회로의 설치 공간으로 활용할 수 있다는 장점이 있다.

Fault Current Limiting Characteristic of Non-inductively Wound HTS Magnets in Sub-cooled $LN_2$ Cooling System

  • Park Dong-Keun;Ahn Min-Cheol;Yang Seong-Eun;Lee Chan-Joo;Seok Bok-Yeol;Yoon Yong-Soo;Ko Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.29-32
    • /
    • 2006
  • An advanced superconducting fault current limiter (SFCL) using $high-T_c$ superconducting (HTS) wire has been developed. The SFCL has a non-inductively wound magnet for reducing loss in normal state. Two types of non-inductively wound magnets, the solenoid type and the pancake type, were designed and manufactured by using Bi-2223 wire in this research. Short-circuit tests of the magnets were performed in sub-cooled $LN_2$ cooling system of 65 K. The magnets are thermally more stable and have a higher critical current in 65 K sub-cooled $LN_2$ cooling system than in 77 K saturated one. Because the resistivity of matrix at 65 K is lower than the resistivity at 77 K, the magnets generate a small resistance to reduce the fault current when the quench occurs. The magnets could limit the fault current to low current level with such a small resistance. The current limiting characteristic of the magnets was analyzed from the test result. The solenoid type was wound in parallel to make it non-inductive. The pancake type was also connected in parallel to be compared with the solenoid type in the same condition. The solenoid type was found to have a good thermal stability compared with the pancake type. It also had as large resistance as the pancake type to limit the fault current in sub-cooled $LN_2$ cooling system.

설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012)

  • 한화택;이대영;김사량;김현정;최종민;박준석;김수민
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

내부 고조파 조정 회로로 구성되는 고효율 370 W GaN HEMT 소형 전력 증폭기 (A Compact 370 W High Efficiency GaN HEMT Power Amplifier with Internal Harmonic Manipulation Circuits)

  • 최명석;윤태산;강부기;조삼열
    • 한국전자파학회논문지
    • /
    • 제24권11호
    • /
    • pp.1064-1073
    • /
    • 2013
  • 본 논문에서는 내부 고조파 조정 회로로 구성되는 셀룰러와 L-대역용 소형의 고효율 370 W GaN(Gallium Nitride) HEMT(High Electron Mobility Transistor) 소형 전력 증폭기(PA)를 구현하였다. 원천 및 2차 고조파 주파수에서 동시에 높은 효율을 내기 위해 새로운 회로 정합 형태를 적용했다. 소형화를 위하여 새로운 41.8 mm GaN HEMT와 2개의 MOS(Metal Oxide Semiconductor) 캐패시터를 구성 물질의 변화를 이용하여 열 저항을 개선한 $10.16{\times}10.16{\times}1.5Tmm^3$ 크기의 새로운 패키지에 와이어 본딩으로 결합하였다. 드레인 바이어스 48 V 인가 시, 개발된 GaN HEMT 전력 증폭기는 370 W 포화 출력 전력(Psat.)과 770~870 MHz에서 80 % 이상, 1,805~1,880 MHz에서 75 % 이상의 드레인 효율(DE)을 나타내었다. 이는 지금까지 보고된 셀룰러와 L대역에서 GaN HEMT 전력 증폭기 중 최고의 효율과 출력 전력 특성이다.

고품질(高品質) 순환골재(循環骨材) 생산(生産)을 위한 폐콘크리트의 단체분리(單體分離) 특성(特性) 연구(硏究) (A Study on the Liberation Characteristics of Waste Concrete for Production of High Quality Recycled Aggregate)

  • 김관호;문명욱;조희찬;안지환
    • 자원리싸이클링
    • /
    • 제19권3호
    • /
    • pp.52-61
    • /
    • 2010
  • 1990년대 후반 이후 국내 건설폐기물의 발생량은 급격하게 증가하였으며, 이를 처리하기 위해 많은 노력을 기울인 결과 97%이상 재활용이 이루어지고 있다. 이 과정에서 폐콘크리트는 단순 파쇄를 통해 순환골재로 생산되고 있으며, 대부분 뒤채움재나 매움재 등 저급한 용도로 재활용되고 있는 실정이다. 그 이유는 골재와 모르타르의 단체분리가 원활히 이루어지지 않아 천연골재 대비 낮은 품질의 순환골재가 생산되기 때문이다. 이에 본 연구에서는 기존 순환골재 생산 공정의 문제점을 파악하기 위하여 기존 공정에서 대표적으로 사용되고 있는 파분쇄 장비를 이용한 폐콘크리트 파분쇄 실험을 통해 골재와 모르타르의 단체분리 특성을 분석하였다. 이 과정에서 골재와 모르타르의 단체분리 효율을 향상시키기 위하여 가열 전처리 방법을 도입하였으며, 우수한 단체분리 특성을 확인하였다. 파분쇄 실험 결과 기존 파분쇄 장비를 통해 생산된 순환골재는 골재와 모르타르의 계면을 따라 선택적인 파분쇄가 발생하지 않아 그 품질이 저하되었으며, 나아가 골재 자체가 충격을 받아 파괴가 일어나는 문제가 존재하였다. 이를 해결하기 위하여 골재와 모르타르의 계면에서의 선택적인 파분쇄를 유도시키는 새로운 분쇄 메커니즘인 gentle breakage를 도입하였으며, 이를 위한 기초 실험으로 폐콘크리트를 자유낙하시켜 순환골재를 생산한 결과 기존 파분쇄 장비에 비해 우수한 단체분리 특성을 확인하였다.