• Title/Summary/Keyword: thermal breakdown

Search Result 319, Processing Time 0.025 seconds

Improvement of Electrical and Thermal Characteristics of Nano-Micro Epoxy Composite

  • Cho, Sung-Hoon;Kim, Yu-Min;Kwon, Jung-Hun;Lim, Kee-Joe;Jung, Eui-Hwan;Lee, Hung-Kyu;Shin, Pan-Seok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.4
    • /
    • pp.160-163
    • /
    • 2011
  • Polymer nanocomposite has been attracting more attention as a new insulation material because homogeneous dispersion of nano-sized inorganic fillers can improve various properties significantly. In this paper, various kinds of epoxy-based nanocomposites were made, and the AC breakdown strengths of Nano filler and micro-$SiO_2$ filler mixtures of epoxy-based composites were analyzed using sphere-to-sphere electrodes. Moreover, nano- and microfiller combinations were investigated as an approach to practical application of nanocomposite insulation materials. Its composition ratio was 100 (resin):82 (hardener):1.5 (accelerator). AC breakdown tests were performed at room temperature ($25^{\circ}C$), $80^{\circ}C$, and $100^{\circ}C$ in the vicinity of $T_g$ ($90^{\circ}C$). Thermal conductivity was measured using TC-30.

EBS for BIM based maintenance management of Thermal Power Plant (BIM기반 화력발전시설 유지관리를 위한 EBS(Elements Breakdown Structure)개발)

  • Kim, Chang-Soo;Cha, Sang-Hoon;Ji, Soung-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.81-82
    • /
    • 2015
  • BIM has been a reliable construction project management tool to handle various kinds of construction information generated in the facility life cycle. To take these advantages, researchers have been promoted numerous studies in a residential, a commercial, and an educational facilities with a large number of on-going projects. However, despite running as the role of essential energy supplier, power plant related BIM research is relatively insufficient than others. In particular, due to the extending of the facility service period and the requirement of the complicated construction project management for 'overhaul' and 'repowering' in the power plant maintenance phase, the needs for using BIM have been increased gradually. For using BIM based maintenance, it is needed to consider an information collecting methods and necessary to develop an appropriate breakdown structure to share information. Therefore, 'EBS' is produced by reviewing the previous research related to BIM and analyzing the repair activities in the maintenance phase. Proposed 'EBS' must be useful not only a judgment between capital expenditure versus revenue expenditure but also appropriate maintenance strategies development for property management.

  • PDF

Study on Electrical Characteristics According Process Parameters of Field Plate for Optimizing SiC Shottky Barrier Diode

  • Hong, Young Sung;Kang, Ey Goo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.4
    • /
    • pp.199-202
    • /
    • 2017
  • Silicon carbide (SiC) is being spotlighted as a next-generation power semiconductor material owing to the characteristic limitations of the existing silicon materials. SiC has a wider band gap, higher breakdown voltage, higher thermal conductivity, and higher saturation electron mobility than those of Si. When using this material to implement Schottky barrier diode (SBD) devices, SBD-state operation loss and switching loss can be greatly reduced as compared to that of traditional Si. However, actual SiC SBDs exhibit a lower dielectric breakdown voltage than the theoretical breakdown voltage that causes the electric field concentration, a phenomenon that occurs on the edge of the contact surface as in conventional power semiconductor devices. Therefore in order to obtain a high breakdown voltage, it is necessary to distribute the electric field concentration using the edge termination structure. In this paper, we designed an edge termination structure using a field plate structure through oxide etch angle control, and optimized the structure to obtain a high breakdown voltage. We designed the edge termination structure for a 650 V breakdown voltage using Sentaurus Workbench provided by IDEC. We conducted field plate experiments. under the following conditions: $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, and $75^{\circ}$. The experimental results indicated that the oxide etch angle was $45^{\circ}$ when the breakdown voltage characteristics of the SiC SBD were optimized and a breakdown voltage of 681 V was obtained.

Humidity Absorbing Deterioration Characteristics of Modified Epoxy Resin System with SN (SN으로 개질된 에폭시 수지 계의 흡습열화 특성)

  • 조영신;심미자;박수길;김상욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.421-424
    • /
    • 1996
  • Effects of humidity absorbing deterioration on AC dielectric breakdown characteristics of modified epoxy resin system with SN(succinonitrile) were investigated. As the forced humidity absorbing deterioration proceeded under high temperature and humidify, glass transition temperature increased. The dielectric breakdown strength increased and then decreased at deterioration cycles higher than 2. Not only, the increment of thermal stability but also, the physical detects such as Internal cracks and voids occurred during the humidity absorbing deterioration cycle were the main causes of the change in dielectric properties.

  • PDF

Analysis on the Chemical and Electrical Characteristic of Vegetable oil by Accelerated Aging (가속열화에 따른 식물성절연유의 화학적.전기적 특성 분석)

  • Choi, Sun-Ho;Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.984-989
    • /
    • 2011
  • Electrical insulation is one of the most important part in a high voltage apparatus. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. Accelerated aging transformer insulating material in vegetable oil was compared to that of mineral oil. Accelerated aging oil samples produced in the oven at $140^{\circ}C$ for 500, 1000, 1500, 2000hours. And Real transformer insulation oils samples of vegetable oil and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. Samples were analyzed at 42, 63, 93, 143, 190, 240, 300 cycles. The mineral and vegetable insulating oils were investigated for breakdown voltage, water content, total acid number, viscosity, volume resistivity, insulating paper and oil permittivity, and dissolved gas analyses. The breakdown voltage of the vegetable insulating oil is higher than that found for the mineral oil; the accelerated aging progress decreased the breakdown voltage. The vegetable oil had a higher water saturation than the mineral oil; the vegetable oil has the superior water characteristics and breakdown voltage. And high viscosity of vegetable oil, care has to be taken, especially when designing the cooling system for a large transformer.

Underwater Discharge Phenomena in Inhomogeneous Electric Fields Caused by Impulse Voltages

  • Lee, Bok-Hee;Kim, Dong-Seong;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.329-336
    • /
    • 2010
  • The paper describes the electrical and optical properties of underwater discharges in highly inhomogeneous electric fields caused by 1.2/50 ${\mu}s$ impulse voltages as functions of the polarity and amplitude of the applied voltage, and various water conductivities. The electric fields are formed by a point-to-plane electrode system. The formation of air bubbles is associated with a thermal process of the water located at the tip of the needle electrode, and streamer coronas can be initiated in the air bubbles and propagated through the test gap with stepped leaders. The fastest streamer channel experiences the final jump across the test gap. The negative streamer channels not only have more branches but are also more widely spread out than the positive streamer channels. The propagation velocity of the positive streamer is much faster than that of the negative one and, in fact, both these velocities are independent of the water conductivity; in addition the time-lag to breakdown is insensitive to water conductivity. The higher the water conductivity the larger the pre-breakdown energy, therefore, the ionic currents do not contribute to the initiation and propagation of the underwater discharges in the test conditions considered.

Study on Thermal Characteristics of IGBT (IGBT의 열 특성에 관한 연구)

  • Kang, Ey-Goo;Ahn, Byoung-Sub;Nam, Tae-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.70-70
    • /
    • 2009
  • In this paper, we proposed 2500V Non punch-through(NPT) Insulated gate bipolar transistor(IGBT) for high voltage industry application. we carried out optimal simulation for high efficiency of 2500V NPT IGBT according to size of device. In results, we obtaind design parameter with 375um n-drift thickness, 15um gate length, and 8um emitter windows. After we simulate with optimal parameter, we obtained 2840V breakdown voltage and 3.4V Vce,sat. These design and process parameter will be used designing of more 2000V NPT IGBT devices.

  • PDF

Development and Evaluation of Epoxy VPI Insulation for High Voltage Rotating Stator Windings (고압회전기 권선용 에폭시 VPI 절연물의 개발과 평가)

  • Lee, Chang-Ryong;Choi, Yong-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05d
    • /
    • pp.38-42
    • /
    • 2003
  • The use of VPI impregnated mica tape as high voltage insulation for large rotating electric machines requires a careful balance of processes and materials to obtain the desired electrical, mechanical and thermal characteristics. The stator insulation systems such as epoxy bonded high voltage mica tape have been produced for many years. One such system employing an epoxy and anhydride impregnating resin developed by Hyundai Heavy Industries, Co. (hereafter, HHI), to satisfy customer requests for an epoxy bonded insulation system. HHI applies the following electrical and thermal evaluations such as dielectric breakdown, voltage endurance, dissipation factor vs. temperature, isothermal weight loss, and so on. A detailed laboratory evaluation can describe specific physical limitations for an insulation system and permit development of long-term operation guidelines that permit full utilization of the proposed system. HHI has found these evaluations very helpful in qualifying insulation system for the repair of both large motors and generators.

  • PDF

The Electrical Conduction Properties of Polyethylene Thin Film for Power Cable with Manufacturing Methods (제작방법에 따른 전력케이블용 폴리에틸렌 박막의 전기전도특성)

  • 조경순;이용우;이수원;홍진웅
    • Electrical & Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.453-460
    • /
    • 1997
  • In order to investigate the electrical conduction properties of polyethylene thin film for power cable with manufacturing methods, the thickness of specimen was the 30, 100[${\mu}{\textrm}{m}$] of LDPE and 200[${\mu}{\textrm}{m}$] of XLPE were manufactured. The experimental condition for conduction properties was measured until the breakdown occurs at temperature ranges from 30 to 110[$^{\circ}C$] and the electric field from 1$\times$10$^3$to 5$\times$10$^{6}$ [V/cm]. As for increase of temperature, the current density of LDPE was increased with constant ratio in low field, but changes with exponential function in high electric field. The tunnel current of pre-breakdown region is shifted toward low field as much as thermal excitation energy. At low electric field, the XLPE showed dominant electrical conduction properties by thermal excitation, and transformation of the electron was resisted by the crystal at high electric field.

  • PDF

Properties of Poly-Si TFT's using Oxide-Nitride-Oxide Films as Gate Insulators (Oxide-Nitride-Oxide막을 게이트 절연막으로 사용하여 제조한 다결정실리콘 박막트랜지스티의 특성)

  • 이인찬;마대영
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1065-1070
    • /
    • 2003
  • HTO(High Temperature Oxide) films are mainly used as a gate insulator for polysilicon thin film transistors(Poly-Si TFT's). The HTO films, however, show the demerits of a high leakage current and a low electric breakdown voltage comparing with conventional thermal oxides even though they have a better surface in roughness than the thermal oxides. In this paper, we propose an ONO(Oxide-Nitride-Oxide) multilayer as the gate insulator for poly-Si TFT's. The leakage current and electric breakdown voltage of the ONO and HTO were measured. The drain current variation of poly-Si TFT's with a variety of gate insulators was observed. The thickness optimization in ONO films was carried out by studying I$\_$on/I$\_$off/ ratio of the poly-Si TFT's as a function of the thickness of ONO film adopted as gate insulator.