• Title/Summary/Keyword: the pass rate

Search Result 583, Processing Time 0.048 seconds

The study of catalytic combustion of VOCs (휘발성 유기염소화합물의 촉매연소 연구)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.1
    • /
    • pp.169-177
    • /
    • 2006
  • In this study, it was studied that the removal rate of VOC by the catalytic combustion. The combustion temperature was changed by the contact type of VOC(space velocity and catalyst depth) and the space velocity(SV) was defined by the rate of gas volume flow rate(Q, $m^3/hr$) over volume(V, $m^3$) of catalyst (SV=Q/V). The space velocity of catalytic combustor is maintained $10,000{\sim}50,000hr^{-1}$. it was studied that the conversion rate of VOC by the catalytic combustion. The combustion temperature was changed by the contact type of VOC and catalyst and the space velocity was defined by the rate of gas volume flow rate over volume of catalyst. The VOC which pass thru the heat exchanger was measured by the hydro ionic detector and measured the VOC removal rate by the activated catalyst in the reaction temperature range of 373K-423K. The removal rate was measured over 100 times. In the automobile painting booth The VOC concentration was 63.37ppm and the removal rate was 70 % at 373K and 78.92% at 423K. The removal rate was increased as increased the temperature.

  • PDF

Gastrointestinal and Hepatic First-pass Effects of Triflusal in Rats (흰쥐에서 트리플루살의 위장관 및 간 초회통과효과)

  • Cho, Hea-Young;Jeong, Tae-Jin;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.4
    • /
    • pp.265-271
    • /
    • 2001
  • In order to elucidate the influence of intestinal and hepatic first-pass effect on the pharmacokinetics of triflusal, the biotransformation of triflusal in the gastrointestinal tract and liver was designed. Moreover, we tried to establish an HPLC method applicable for bioassay and available to pharmacokinetics, not only with the simultaneous determination of triflusal and its active metabolite, 2-hydroxy-4-trifluoromethyl benzoic acid (HTB), but also with improving sensitivity. After the administration of triflusal (10 mg/kg) and HTB (10 mg/kg) into femoral vein, portal vein (only triflusal) and oral route (only triflusal), pharmacokinetic parameters were investigated from the plasma concentration-time profiles of triflusal and HTB in rats. An HPLC method was developed for the simultaneous determination of triflusal and HTB in rat plasma, urine and bile. The HPLC analysis was carried out using a C18 column and acetonitrile-methanol-water (25:10:65, v/v/v) as the mobile phase and UV detection at 234 nm. Furosemide was used as the internal standard. The calibration curves were linear over the concentration range $0.05-5.0\;{\mu}g/ml$ for triflusal and $0.2-200.0\;{\mu}g/ml$ for HTB with correlation coefficients greater than 0.999 and with intra-day or inter-day coefficients of variation not exceeding 10.0%. This assay procedure was applied to the study of metabolite pharmacokinetics of triflusal and HTB in rats. It was supposed that triflusal was almost metabolized in vivo because urinary and biliary excreted amounts of triflusal could be ignored as it was lower than 1.2% of the administered dose. According to the gastrointestinal and hepatic biotransformation pathways of triflusal, it was found that triflusal was hydrolyzed by about 5% in intestine and metabolized by about 53% in liver, and that the bioavailability of triflusal after oral administration of triflusal was 0.44, and also that the fraction of total elimination rate of triflusal which formed HTB in liver $(F_{mi},\;%)$ was about 98%. These results showed that triflusal was almost metabolized in liver, and the total elimination of triflusal in the body was dependent to the formation rate of HTB from triflusal in liver.

  • PDF

Studies on the Qualitative and Quantitative Damage of Sudangrass In fected with Leaf Blight ( Helminthosporium turcium PASS ) (매문병 ( Helminthosporium turcium PASS ) 에 감염된 수단그라스의 양적.질적 피해에 관한 연구)

  • 이상범;김정갑;김봉구;한흥전;양종성
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.6 no.1
    • /
    • pp.65-70
    • /
    • 1986
  • This experiment was carried out to identify the main pathogens infected with Piper sudangrass and to evaluate the qualitative and quantitative damage of the plants infected with leaf blight (Helminthosporium turcicum PASS) under different levels of nitrogen fertilizer (20, 30 and 40 kg/10a). The experiment was design as a randomized block design with 4 replications at experimental field of Livestock Experiment Station in Suweon, 1984. The results obtained are summarized as follows: 1. The main fungi isolated from sudangrass were identified as Helminthoporium turcicum and Collectotricum graminicolum, but 1 species fungus was not identified. 2. Leaf blight was first found on June 20 and appeared extremely in the regrowth plants from July to September. The rate of attack was associated with increasing of nitrogen fertilization (P<0.01). 3. Fresh and dry matter yields were as much as 47 and 38 percentage lower in leaf blight infected plants (disease severity: V) than those of no visible infection. 4. Concentrations of crude fat and crude protein were decreased in the plants infected with Helminthosporium leaf blight, but lignin content was increased. Dry matter and organic matter digestibility of the plants were negative correlated with the infection of leaf blight(P<0.01).

  • PDF

Forged Product Characteristic and Cold Rolling Simulation for High-Nitrogen Stainless Steel (HNS) (TP304계 고질소 스테인레스강의 단조특성과 냉간압연 모사)

  • Lee, M.R.;Lee, J.W.;Kim, B.K.;Kim, Y.D.;Shin, J.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.310-313
    • /
    • 2009
  • Several high nitrogen stainless steel ingots(100kg) were fabricated with changing Ni and $[N]_2$ contents by Pressurized Vacuum Induction Melting(P_VIM). After free forging process, chemical compositions, microstructure and mechanical properties were estimated. Hardness was increased with the increase of $[N]_2$ content. Furthermore, microstructure including a lot of tempering twins was observed with optical microscope. Mechanical properties were estimated as function of solution treatment temperature and cooling method(air/water) under duration time of 1 hr on sample that were fabricated with Ni content under the atmospheric $[N]_2$ pressure. At solution treatment range of $1050{\sim}1100^{\circ}C$, hardness was decreased with the increase of solution temperature and there were little discrepancy of microstructure and hardness with cooling method. Computer simulation was carried out in order to inspect pass schedule in cold rolling process. When the condition of simulation was roll speed of 2.5mpm, rolling rate $15{\sim}17%$ per pass, it was ascertained that the formation such as deformation by sticking and lamellar sliver etc. was restricted from a simulation.

  • PDF

Glass Dissolution Rates From MCC-1 and Flow-Through Tests

  • Jeong, Seung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.257-258
    • /
    • 2004
  • The dose from radionuclides released from high-level radioactive waste (HLW) glasses as they corrode must be taken into account when assessing the performance of a disposal system. In the performance assessment (PA) calculations conducted for the proposed Yucca Mountain, Nevada, disposal system, the release of radionuclides is conservatively assumed to occur at the same rate the glass matrix dissolves. A simple model was developed to calculate the glass dissolution rate of HLW glasses in these PA calculations [1]. For the PA calculations that were conducted for Site Recommendation, it was necessary to identify ranges of parameter values that bounded the dissolution rates of the wide range of HLW glass compositions that will be disposed. The values and ranges of the model parameters for the pH and temperature dependencies were extracted from the results of SPFT, static leach tests, and Soxhlet tests available in the literature. Static leach tests were conducted with a range of glass compositions to measure values for the glass composition parameter. The glass dissolution rate depends on temperature, pH, and the compositions of the glass and solution, The dissolution rate is calculated using Eq. 1: $rate{\;}={\;}k_{o}10^{(ph){\eta})}{\cdot}e^{(-Ea/RT)}{\cdot}(1-Q/K){\;}+{\;}k_{long}$ where $k_{0},\;{\eta}$ and Eaare the parameters for glass composition, pH, $\eta$ and temperature dependence, respectively, and R is the gas constant. The term (1-Q/K) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_{0},\;{\eta}\;and\;E_{a}$ are the parameters for glass composition, pH, and temperature dependence, respectively, and R is the gas constant. The term (1-Q/C) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_0$, and Ea are determined under test conditions where the value of Q is maintained near zero, so that the value of the affinity term remains near 1. The dissolution rate under conditions in which the value of the affinity term is near 1 is referred to as the forward rate. This is the highest dissolution rate that can occur at a particular pH and temperature. The value of the parameter K is determined from experiments in which the value of the ion activity product approaches the value of K. This results in a decrease in the value of the affinity term and the dissolution rate. The highly dilute solutions required to measure the forward rate and extract values for $k_0$, $\eta$, and Ea can be maintained by conducting dynamic tests in which the test solution is removed from the reaction cell and replaced with fresh solution. In the single-pass flow-through (PFT) test method, this is done by continuously pumping the test solution through the reaction cell. Alternatively, static tests can be conducted with sufficient solution volume that the solution concentrations of dissolved glass components do not increase significantly during the test. Both the SPFT and static tests can ve conducted for a wide range of pH values and temperatures. Both static and SPFt tests have short-comings. the SPFT test requires analysis of several solutions (typically 6-10) at each of several flow rates to determine the glass dissolution rate at each pH and temperature. As will be shown, the rate measured in an SPFt test depends on the solution flow rate. The solutions in static tests will eventually become concentrated enough to affect the dissolution rate. In both the SPFt and static test methods. a compromise is required between the need to minimize the effects of dissolved components on the dissolution rate and the need to attain solution concentrations that are high enough to analyze. In the paper, we compare the results of static leach tests and SPFT tests conducted with simple 5-component glass to confirm the equivalence of SPFT tests and static tests conducted with pH buffer solutions. Tests were conducted over the range pH values that are most relevant for waste glass disssolution in a disposal system. The glass and temperature used in the tests were selected to allow direct comparison with SPFT tests conducted previously. The ability to measure parameter values with more than one test method and an understanding of how the rate measured in each test is affected by various test parameters provides added confidence to the measured values. The dissolution rate of a simple 5-component glass was measured at pH values of 6.2, 8.3, and 9.6 and $70^{\circ}C$ using static tests and single-pass flow-through (SPFT) tests. Similar rates were measured with the two methods. However, the measured rates are about 10X higher than the rates measured previously for a glass having the same composition using an SPFT test method. Differences are attributed to effects of the solution flow rate on the glass dissolution reate and how the specific surface area of crushed glass is estimated. This comparison indicates the need to standardize the SPFT test procedure.

  • PDF

Symbol Rate Estimation and Modulation Identification in Satellite Communication System (위성통신시스템에서 심볼율 추정과 변조 방식 구분법)

  • Choi Chan-ho;Lim Jong-bu;Im Gi-hong;Kim Young-wan;Kim Ho-kyom
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.8A
    • /
    • pp.671-678
    • /
    • 2005
  • This paper proposed symbol rate method which does not require a priori knowledge on the symbol rate and simplified modulation identification method to classify BPSK, QPSK, 8PSK signal. In order to estimate the unknown symbol rate, sliding FFT and simple moving average to estimate the spectrum of the signals is utilized, and sliding window and decimation, LPF blcok to estimate the proper symbol rate is used. Although conventional modulation ID method must use SNR value as the test statistics, the receiver cannot estimate the SNR value since the receiver cannot know the modulation type at the start of communication, and bit resolution is high due to using nonlinear function such as log, cosh. Therefore, we proposed the simplified fixed SNR value method. The performance of symbol rate estimation and modulation ID is shown using Monte Carlo computer simulation. This paper show that symbol rate estimation also has good performance in low SNR, and proposed simplified fixed SNR method has almost equivalent performance compared to conventional method.

Effect of processing parameters on TiO2 film by room temperature granule spray in vacuum (상온진공과립분사에 의한 TiO2 코팅층에 미치는 공정변수의 영향)

  • Kim, Han-Gil;Park, Yoon-Soo;Bang, Kook-Soo;Park, Dong-Soo;Park, Chan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • $TiO_2$ films, thickness of $1{\sim}30{\mu}m$ were deposited on glass substrate at room temperature by room temperature granule spray in vacuum. The starting powder was calcinated at $600^{\circ}C$ for 4 h using $Al_2O_3$ crucible in the furnace. The particle size of the $TiO_2$, $1.5{\mu}m$ was measured by a particle size analyzer. The effect of different process parameters such as number of pass, gas flow rate and feeder voltage was studied. As the number of passes increased, the film thickness increased proportionally due to adequate kinetic energy conserved. The effect of three different flow rates (i.e. 15, 25, and 35 LPM) on deposited film was investigated. As gas flow rate increased, the film thickness increased up to 25 LPM and then decreased. Higher feeder voltage with low flow rate of 15 LPM resulted in unsufficient coating thickness due to insufficient kinetic energy. Microstructure of $TiO_2$ films was investigated by scanning electron microscope and high resolution tramission electron microscope.

Dynamic PCA algorithm for Detecting Types of Electric Poles (전신주의 종류 판별을 위한 동적 PCA 알고리즘)

  • Choi, Jae-Young;Lee, Jang-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.651-656
    • /
    • 2010
  • This paper proposes a new dynamic PCA algorithm to recognize types of electric poles, which is necessary for a mobile robot moving along the neutral line for inspecting high-voltage facilities. Since the mobile robot needs to pass over the electric poles and grasp the neutral wire again for the next region inspection, the detection of the electric pole type is a critical factor for the successful passing-over the electric pole. The CCD camera installed on the mobile robot captures the image of the electric pole while it is approaching to the electric pole. Applying the dynamic PCA algorithm to the CCD image, the electric pole type has been classified to provide the stable grasping operation for the mobile robot. The new dynamic PCA algorithm replaces the reference image in real time to improve the robustness of the PCA algorithm, adjusts the brightness to get the clear images, and applies the Laplacian edge detection algorithm to increase the recognition rate of electric pole type. Through the real experiments, the effectiveness of this proposed dynamic PCA algorithm method using Laplacian edge detecting method has been demonstrated, which improves the recognition rate about 20% comparing to the conventional PCA algorithm.

A study on improvement of leaky bucket UPC algorithm in ATM networks (ATM 망에서의 Leaky Bucket UPC 알고리즘의 성능 개선에 관한 연구)

  • 심영진;박성곤;조용환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.5
    • /
    • pp.1116-1125
    • /
    • 1997
  • In this paper, the modified UPC(Usage Parameter Control) algorithm is proposed. The proposed UPC algorithm is based on Leakey Bucket algorithm and adds the characteristics of the jumping window algorithm for monitoring the average bit rate. The proposed algorithm let a cell, which is tagged by Leaky Bucket algorithm, pass through the network, if the network does not violate the average bit rate. The measuring method of window mechanism like jumping window. This paper supposes On/Off traffic source model of rthe performance evaluation and analysis of the proposed algorithm. Therefore, as simulation results, the proposed algorithm acquires more reduced results of the cell loss rate and bucket size than the Leaky Bucket algorithm.

  • PDF

A Study on the Characteristics of the Liquid-gas Ejector (Liguid-gas Ejector의 구동성능 특성에 관한 연구)

  • Park, Gi-Tae;Jin, Zhen-Hua;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1047-1052
    • /
    • 2008
  • The aim of this paper is that studies on the characteristics of the liquid-gas ejector. Could get data about various model using numerical analysis. Compare and analyze result that get by an experiment and numerical analysis. And studied Characteristics of the ejector. In this paper, Numerical analysis model is gotten divided according to each Throat ratio as three types. Each throat ratio is 0, 4 and 7.5. According to the result that analyze basic model, pressure became lower causing the volume flow rate increase. In CFD studies, Fixed volume flow rate by these result and analyzed ejector performance. As a result, there was no change of pressure to Throat's Enterance, and pressure became low while pass the throat. Since, pressure recovered while passing diffuser. The outer flow velocity did not change greatly to change of volume flow rate. This research expects that is utilized to data for performance elevation hereafter.

  • PDF