• Title/Summary/Keyword: tester device

Search Result 98, Processing Time 0.02 seconds

A Study on Refresh Time Improvement of DRAM using the MEDICI Simulator (MEDICI 시뮬레이터를 이용한 DRAM의 Refresh 시간 개선에 관한 연구)

  • 이용희;이천희
    • Journal of the Korea Society for Simulation
    • /
    • v.9 no.4
    • /
    • pp.51-58
    • /
    • 2000
  • The control of the data retention time is a main issue for realizing future high density dynamic random access memory. The novel junction process scheme in sub-micron DRAM cell with STI(Shallow Trench Isolation) has been investigated to improve the tail component in the retention time distribution which is of great importance in DRAM characteristics. In this' paper, we propose the new implantation scheme by gate-related ion beam shadowing effect and buffer-enhanced ${\Delta}Rp$ (projected standard deviation) increase using buffered N-implantation with tilt and 4X(4 times)-rotation that is designed on the basis of the local-field-enhancement model of the tail component. We report an excellent tail improvement of the retention time distribution attributed to the reduction of electric field across the cell junction due to the redistribution of N-concentration which is Intentionally caused by ion Beam Shadowing and Buffering Effect using tilt implantation with 4X-rotation. And also, we suggest the least requirements for adoption of this new implantation scheme and the method to optimize the key parameters such as tilt angle, rotation number, Rp compensation and Nd/Na ratio. We used MEDICI Simulator to confirm the junction device characteristics. And measured the refresh time using the ADVAN Probe tester.

  • PDF

Effects of C, Si and RE on Microstructures of DCI using Permanent Mold Casting (금형주조 구상흑연주철의 미세조직에 미치는 C, Si과 RE의 영향)

  • Kim, Sug-Won;Park, Jin-Sung;Khalil, Khalil. A.
    • Journal of Korea Foundry Society
    • /
    • v.26 no.4
    • /
    • pp.174-179
    • /
    • 2006
  • This study aims to investigate the microstructures and mechanical properties of DCI manufactured by sand and metal mold casting. To prohibit the formation of the chill, carbon, silicon and rare earth($0{\sim}0.2\;wt%$) were controlled and temperature of metal mold was constantly kept at $160^{\circ}C$. The sizes, counts and nodularity ratios of nodules were analyzed by image analysis device. Wear test using pin-on-disc wear tester was carried out under the conditions of load 47.2N, velocity 0.4 m/s and distance 2000 m. Tensile test using Instron type testing machine was performed with velocity of 0.1 mm/min according to the KS B 0802. The formation of the chill was not observed when percentage of the carbon and silicon were 3.8 and 2.5. Mechanical properties of GCD manufactured by metal mold were better than sand casting.

Elasticity Modulus Change Research of Polymer Ultraviolet Dosage by using ESPI (ESPI를 이용한 자외선조사량에 따른 폴리머애자의 탄성계수 변화 연구)

  • Kim, Kyeong-Suk;Kim, Dong-Soo;Chang, Ho-Sub;Pack, Chan-Joo;Jang, Wan-Sik;Jung, Hyun-Chul
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.4
    • /
    • pp.485-490
    • /
    • 2010
  • Recently, environment problems have effects on the electronic equipments. Security problems are presented. For security reasons, it is necessary to study electronic equipments. In this paper, we handle the Elasticity modulus on the polymer insulator by UV irradiation. The types of material are used in this experiment, is the EPDM (Ethylene Propylene Diene Monomer). For increasing the reliability, real material specimens are used. For this study, we used ESPI (Electronic speckle pattern interferometry), UTM (Universal thesting machine) device, Accelerated weathering tester. Through this measurement, we evaluated how much UV irradiation has effect on polymer insulator and how long does it take to change the polymer insulator. Also this paper will give a help in electronic industry and the method of measuring the insulator elasticity modulus of polymer could be utilized in life estimation and replacement time of the products of electronic equipment that is used in real industrial fields.

Power module stray inductance extraction: Theoretical and experimental analysis

  • Jung, Dong Yun;Jang, Hyun Gyu;Cho, Doohyung;Kwon, Sungkyu;Won, Jong Il;Lee, Seong Hyun;Park, Kun Sik;Lim, Jong-Won;Bae, Joung Hwan;Choi, Yun Hwa
    • ETRI Journal
    • /
    • v.43 no.5
    • /
    • pp.891-899
    • /
    • 2021
  • We propose a stray inductance extraction method on power modules of the few-kilovolts/several-hundred-amperes class using only low voltages and low currents. The method incorporates a double-pulse generator, a level shifter, a switching device, and a load inductor. The conventional approach generally requires a high voltage of more than half the power module's rated voltage and a high current of around half the rated current. In contrast, the proposed method requires a low voltage and low current environment regardless of the power module's rated voltage because the module is measured in a turn-off state. Both theoretical and experimental results are provided. A physical circuit board was fabricated, and the method was applied to three commercial power modules with EconoDUAL3 cases. The obtained stray inductance values differed from the manufacturer-provided values by less than 1.65 nH, thus demonstrating the method's accuracy. The greatest advantage of the proposed approach is that high voltages or high currents are not required.

Tuning the Interference Color with PECVD Prepared DLC Thickness (PECVD를 이용한 DLC 두께 제어에 따른 간섭색 구현)

  • Park, Saebom;Kim, Kwangbae;Kim, Hojun;Kim, Chihwan;Choi, Hyun Woo;Song, Ohsung
    • Korean Journal of Materials Research
    • /
    • v.31 no.7
    • /
    • pp.403-408
    • /
    • 2021
  • Various surface colors are predicted and implemented using the interference color generated by controlling the thickness of nano-level diamond like carbon (DLC) thin film. Samples having thicknesses of up to 385 nm and various interference colors are prepared using a single crystal silicon (100) substrate with changing processing times at low temperature by plasma-enhanced chemical vapor deposition. The thickness, surface roughness, color, phases, and anti-scratch performance under each condition are analyzed using a scanning electron microscope, colorimeter, micro-Raman device, and scratch tester. Coating with the same uniformity as the surface roughness of the substrate is possible over the entire experimental thickness range, and more than five different colors are implemented at this time. The color matched with the color predicted by the model, assuming only the reflection mode of the thin film. All the DLC thin films show constant D/G peak fraction without significant change, and have anti-scratch values of about 19 N. The results indicate the possibility that nano-level DLC thin films with various interference colors can be applied to exterior materials of actual mobile devices.

The metameric effect of monolithic zirconias with varying yttrium ratios

  • Mehmet Ejder Guven;Ozlem Kara
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.48-56
    • /
    • 2024
  • PURPOSE. To evaluate the metameric disparities among monolithic zirconia materials with differing yttrium compositions across various lighting conditions. MATERIALS AND METHODS. Thirty-six square-shaped zirconia samples measuring 10 × 10 × 0.5 mm were prepared from monolithic zirconia materials with three different yttrium contents. A 0.2 mm thick layer of polymerized dual-polymerizable self-adhesive resin cement was created using a silicone mold with the same dimensions as the prepared zirconia specimens. To evaluate metamerism, color measurements were conducted using a spectrophotometer device on a neutral gray background in a color measurement cabinet that offers four different illumination environments. All samples underwent aging by subjecting them to 10000 thermal cycles using a thermal cycle tester. Following thermal aging, color measurements were taken once more, and the data were recorded using the CIE L*, a*, b* color system. Two-way ANOVA and Post-hoc Bonferroni tests were employed to analyze the data. RESULTS. It was observed that there was no statistical difference among the color measurements made in different illumination environments of the monolithic zirconia ceramics used to evaluate metamerism (P > .05). This observation remained consistent both before and after thermal aging. After thermal aging, the color of monolithic zirconia materials exhibited a tendency towards red and yellow hues, accompanied by a decrease in brightness levels. CONCLUSION. It can be stated that different illumination conditions did not affect the metamerism of monolithic zirconia materials, but there was a color change in monolithic zirconia materials after a thermal aging period equivalent to one year.

Comparison of Egg Testing Devices for Internal Egg Quality Measurements (계란 할란검사장비의 성능 비교)

  • Kim, Dong Jun;Jeon, Seung Yob;Kim, Hee Won;Won, Jea Sun;Lee, Jae Cheong;Lee, Kyung-Woo
    • Korean Journal of Poultry Science
    • /
    • v.43 no.4
    • /
    • pp.229-233
    • /
    • 2016
  • This study was conducted to compare three commercially available egg testing devices for measuring egg quality. The devices used were a Laser-type (automatic), a Ultrasonic-type (automatic), and a Probe-type (manual). Fresh eggs weighing 60~68 grams were obtained from a commercial hen farm. Three trials were conducted. In Trial 1, a total of 50 eggs were successively analyzed by the three egg testing devices. In Trial 2, fresh eggs were successively analyzed by a combination of two egg testing devices. In Trial 3, a total of 600 eggs (weighing 60~68 grams) laid by same flock were selected, further divided into three sub-groups with a total of 200 eggs, and analyzed by an egg testing device. In Trials 1 and 2, no apparent difference was observed in egg weight between egg testing devices. However, albumin height was scored highest in the Ultrasonic-type egg tester followed by the Probe-type and Laser-type (Trials 1 and 2). Consequently, the Haugh unit was similarly altered. Yolk color was highest in the Laser-type egg tester followed by the Ultrasonic-type and Probe-type (Trials 1 and 2). When fresh eggs laid by a single flock were independently analyzed by three devices, egg weight did not differ, but albumin height and Haugh unit were higher (p<0.05) in the Ultrasonic-type egg tester than in the Probe-type or Laser-type testers. However, Laser-type testers produced higher (p<0.05) yolk color values than the Ultrasonic-type or Probe-type egg testers. In conclusion, the commercially available egg testing devices exhibited performance differences in measuring egg qualities, which warrants further consideration as to whether the magnitude of bias and precision between the devices could be acceptable in the egg grading system, especially when assessing eggs stored for certain durations.

Technology to Remove Trace Pollutants in Sewage Treatment Water Using Jellyfish Characteristics (해파리의 특성을 활용한 하수처리장 처리수 내 미량오염물질 제거 기술)

  • Hyeok Jin Park;Eun Jin Kim;Kyung Sil Choo;Joo Eun Shim;Min-Kyeong Yeo
    • Applied Chemistry for Engineering
    • /
    • v.35 no.1
    • /
    • pp.54-60
    • /
    • 2024
  • The present study was aimed to evaluate the removal of the trace pollutants (heavy metals and microplastics) in the sewage treatment plant by using the jellyfish Extract at Immunity reaction (JEI) of Aurelia coerulea. The experiment was conducted on two different scales: the lab scale using a Jar-tester and the Pilot system scale equipped with two newly developed devices in the laboratory, the active tube connection mixed system and the concentration integrated separation device. Compared to anionic polymers currently used in the field, JEI showed similar or higher efficiency to remove the trace pollutants. When JEI was added to the effluent through the Pilot system, the combination of JEI and the trace pollutants was maximized through two mixing processes, and as a result, the removal rate of the trace pollutants was greatly improved. Based on these results, we propose the present technology as an alternative to removing trace pollutants that can reduce ecosystem risk and minimize the generation of inorganic waste, away from the existing method.

Design and Analysis of a 12 V PWM Boost DC-DC Converter for Smart Device Applications (스마트기기를 위한 12 V 승압형 PWM DC-DC 변환기 설계 및 특성해석)

  • Na, Jae-Hun;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.239-245
    • /
    • 2016
  • In this study, a 12 V PWM boost converter was designed with the optimal values of the external components of the power stage was well as the compensation stage for smart electronic applications powered by a battery device. The 12 V boost PWM converter consisted of several passive elements, such as a resistor, inductor and capacitor with a diode, power MOS switch and control IC chip for the control PWM signal. The devices of the power stage and compensation stage were designed to maintain stable operation under a range of load conditions as well as achieving the highest power efficiency. The results of this study were first verified by a simulation in SPICE from calculations of the values of major external elements comprising the converter. The design was also implemented on the prototype PCBboard using commercial IC LM3481 from Texas Instruments, which has a nominal output voltage of 12 V. The output voltage, ripple voltage, and load regulation with the line regulation were measured using a digital oscilloscope, DMM tester, and DC power supply. By configuring the converter under the same conditions as in the circuit simulation, the experimental results matched the simulation results.

A Study on the Development of High-sensitivity AEC-sensor for Minimization of Dose Creep in Diagnostic Imaging System (진단영상 시스템에서 선량크리프 현상의 최소화를 위한 고감도 AEC 센서에 관한 연구)

  • Kim, Kyo-Tae;Han, Moo-Jae;Heo, Ye-Ji;Kim, Joo-Hee;Kang, Sang-Sik;Park, Ji-Koon;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.321-325
    • /
    • 2016
  • Dose creep is one of clinical errors that arises from the tester's inexperience or carelessness, and according to Task Group #116 of American Association of Physicists in Medicine, its continued occurrence is being reported in the digital method. At this point, the demand for an automatic exposure control device that minimizes the dose creep phenomenon and can improve reproducibility is increasing. In this study is to consider the automatic exposure control device sensor that can is not only easy to produce, but also reduce the dose creep phenomenon by conducting a research on high-efficient semiconductor sensor. As a result, the Intrinsic-type and PIN-type sensors have excellent optical property compared to Ref sensor, would have less shading effect, and have relatively low sensitivity, but would provide accurate feedback signals to automatic exposure control device with its consistent tendency according to exposure condition changes.