• Title/Summary/Keyword: test time

Search Result 20,726, Processing Time 0.053 seconds

Evaluation of Domestic Tack-Coating Material's Properties for Asphalt Concrete Pavement (국내 아스팔트 콘크리트 포장용 택코팅제의 기초물성 평가)

  • Lee, Jaejun;Kim, Seung-Hoon;Lim, Jaekyu;Han, Jongmin;Lee, Kwang-Joon
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.121-128
    • /
    • 2014
  • PURPOSES : The objective of this study is to evaluate the tack-coating material's properties using the bitumen bond strength(BBS) test and damping test as function of changed curing times. In this study, bonding strength tests were performed according to the curing time of tack coating materials. METHODS : In order to investigate bonding characteristic of tack coating materials, the Pneumatic Adhesion tensile Testing Instrument(PATTI) device is used to measure the bond strength between the tack coating materials and aggregate substrate based on the AASHTO TP-91. Also, damping test as in situ test was used to determine an appropriate traffic openting time for construction vehicle. Four different tack-coating materials were used in this study. The BBS tests were performed a one hour curing and testing temperatures of $5^{\circ}C$, $15^{\circ}C$, and $25^{\circ}C$. Damping test was conducted at 30min, 60min, 90min, and 120 min of curing times with temperatures of $20^{\circ}C$ and $30^{\circ}C$. RESULTS and CONCLUSIONS : The BBS test results show various bond strength as function of tack coat materials. At the same testing condition, A tack coat material shows almost two times higher than D tack coat materials although both materials are satisfied the criteria of material's physical properties. Also, Dampting test results shows similar trend with BBS test result. The damping test result was significantly changed as function of tack coat materials. Based on this study, the tack coating material's curing time is very important. Therefore, both curing time and the bond strength's characteristic has to be considered in standard specification.

Evaluation of the Corrosion Resistance of Plated Ni and Ni-Cr Layers on Fe Substrate by Using Salt Spray, CASS and EC Tests (철소지 위에 형성된 니켈 및 니켈-크롬 도금층의 염수분무, 캐스, 전해부식시험법을 이용한 내식성평가)

  • 신재호;이동훈;이재봉;신성호
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.4
    • /
    • pp.307-316
    • /
    • 2003
  • Salt spray, CASS(copper accelerated acetic salt spray) and EC(electrolytic corrosion) tests were performed in order to evaluate the corrosion resistance of plated Ni and Ni-Cr layers on Fe substrate. Compared with the conventional methods such as salt spray and CASS, the electrochemical method such as EC test may be beneficial in terms of test time span and quantitative accuracy. Furthermore, EC test can also become the alternative method to evaluate the resistance to corrosion of coatings by measuring the corrosion potentials of the coated layers in the electrolyte during the off-time of EC cycles. Compared with the corrosion potentials of pure iron, nickel, chromium, those potentials of coated layers can be used to anticipate the extent of corrosion. Results showed that in terms of the test time span, EC test gave 14 times and 21 times faster results than the salt spray test in cases of $5\mu\textrm{m}$ Ni and $20\mu\textrm{m}$ Ni plated layers, respectively. In addition, EC test also offered the shorter test time span than CASS test in cases of $5 \mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr, and $20\mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr on Fe substrate by 78 times and 182 times, respectively. Therefore, EC test can be regarded as the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as salt spray and CASS.

Evaluation of Life Time for Anti-Corrosive Methods for Marine Steel Sheet by Cyclic Corrosion Test (실내 가속부식시험을 통한 해양 강관합성 말뚝의 방식 기법 수명 평가)

  • Park, J.W.;Lee, J.G.;Lee, K.W.;Kim, J.H.;Jung, M.K.;Lee, J.H.
    • Corrosion Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.243-250
    • /
    • 2009
  • When a steel sheet pipe applied to marine environment, an anti-corrosive coating should be treated to obtain long-term life-time for steels, especially, splash zone. Although anti-corrosive property of coatings is required to be tested in real marine environment, it is difficult because of long test time such as 20 years or more time. Therefore, we used cyclic corrosion tester in a laboratory, which has similar conditions with salt-dry-wet process such as real marine environment. Anti-corrosive properties of the coatings and two steels were tested their anti-corrosive properties under cyclic corrosion test conditions(KS D ISO 14993) and the results were compared with estimate life-time in real marine environment. According to cyclic corrosion test, accelerated corrosive factor of each anti-corrosive coating was investigated accelerated corrosive factor from impedance with EIS method. Accelerated corrosive factor of type SS400 carbon steel and A690 was also investigated their accelerated corrosive factor from the regression curves of weigh loss results. One of the anti-corrosive coatings showed about 50 years life-time compared with standard sample life-time. Carbon steel SS400 showed from 0.1 mm/yr to 0.06 mm/yr as its corrosion rate.

Oxygen Toxicity: Behavioral Assessment by Swim Test in Mouse Exposed to Hypoxia and Hyperoxia (수영 시험 모델에서 산소 농도에 따른 운동성 변화와 독성 평가)

  • 김동희;강문철;김재일;이근호;김광열;김형건
    • Toxicological Research
    • /
    • v.19 no.2
    • /
    • pp.99-104
    • /
    • 2003
  • This study was aimed to evaluate the effect of oxygen on motor activity and toxicity in male mice. The modified Porsolt forced swim test (FST) was used and the distance and time of movement by mice were analyzed in 15。C water bath for 20 minutes using the automatic Ethovision videotracking system. Analyses were carried out before and after 20 minutes of exposure to 10%-70% concentration of normobaric oxygen. The effects of inspired oxygen tension on the distance and time of movement showed the similar trends, but changes in distance were more prominent. Both the distance and time of movement increased after exposure to 30% and 40% oxygen concentration. The distance and time of movement also increased upon exposure to 50% and 60% oxygen. In contrast, increases En movement and time under exposure to 21% oxygen concentration were suppressed when exposed to over 50% oxygen concentration. With exposure to 10% oxygen, there was a significant decrease in the distance of movement and a slight suppression of movement time. During the swim test, 12.5%, 37.5%, and 87.5% of the mice drowned after exposure to 10%, 60%, and 70% oxygen concentration, respectively. These results suggest that motor activity can be enhanced by inspired oxygen up to 40% concentration. When hypoxic and hyperoxic oxygen exposure over 50%, motor activity is reduced and toxicity may be induced.

A Study on the Life Time of RCD in Coastal Area (해안지역에서의 저압용 누전차단기 교체주기 연구)

  • Kim, Chong-Min;Choi, Myeong-Il;Shong, Kil-Mok;Seo, Jung-Youl;Shin, Jin-Yong;Kim, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.85-92
    • /
    • 2011
  • The role of RCDs(Residual Current Protective Device) that are installed before the load is very important for preventing electric shock and electrical fire. However, although fault rate of RCD is increasing due to deterioration and long period usage, the RCD is permanently used without a checking of performance evaluation and it causes the electrical accident. In this paper, the amount of airborne chloride is researched in domestic costal area and the accelerated life test is conducted using a salt water spray tester in order to decide the life time of RCD. Aa a result of an accelerated life test, the MTTF(Mean Time To Failure) of RCD is 110.81 hours and B10 life time of RCD is 45.81 hours for the all samples. when an accelerated life test result is applied to within 2 km costal area, the life time of RCD is predicted about 5 years.

Research on the formulation of Base Bleed Unit for the reduction of process lead time (항력감소제 공정 Lead time 단축을 위한 조성개발 연구)

  • Son Hyun-Il;Chae Kyung-Min;Suh Hyuk;Choi Young-Ki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.479-483
    • /
    • 2005
  • BBU is the weapon system for the extension of range through the reduction of base drag in 155mm. It has been mass-produced since 2000. The purpose of this research is productivity increase through the reduction of process lead time. Development process is as follows. First, formulation tests about propellent and liner, Second, spin test and final firing test about end products.

  • PDF

New test method for real-time measurement of SCC initiation of thin disk specimen in high-temperature primary water environment

  • Geon Woo Jeon;Sung Woo Kim;Dong Jin Kim;Chang Yeol Jeong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4481-4490
    • /
    • 2022
  • In this study, a new rupture disk corrosion test (RDCT) method was developed for real-time detection of stress corrosion cracking (SCC) initiation of Alloy 600 in a primary water environment of pressurized water reactors. In the RDCT method, one side of a disk specimen was exposed to a simulated primary water at high temperature and pressure while the other side was maintained at ambient pressure, inducing a dome-shaped deformation and tensile stress on the specimen. When SCC occurs in the primary water environment, it leads to the specimen rupture or water leakage through the specimen, which can be detected in real-time using a pressure gauge. The tensile stress applied to the disk specimen was calculated using a finite element analysis. The tensile stress was calculated to increase as the specimen thickness decreased. The SCC initiation time of the specimen was evaluated by the RDCT method, from which result it was found that the crack initiation time decreased with the decrease of specimen thickness owing to the increase of applied stress. After the SCC initiation test, many cracks were observed on the specimen surface in an intergranular fracture mode, which is a typical characteristic of SCC in the primary water environment.

Development of KOMPSAT-2 Vehicle Dynamic Simulator for Attitude Control Subsystem Functional Verification

  • Suk, Byong-Suk;Lyou, Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1465-1469
    • /
    • 2003
  • In general satellite verification process, the AOCS (Attitude & Orbit Control Subsystem) should be verified through several kinds of verification test which can be divided into two major category like FBT (Fixed Bed Test) and polarity test. And each test performed in different levels such as ETB (Electrical Test Bed) and satellite level. The test method of FBT is to simulate satellite dynamics with sensors and actuators supported by necessary environmental models in ETB level. The VDS (Vehicle Dynamic Simulator) try to make the real situation as possible as the on-board processor will undergo after launch. The purpose of FBT test is to verify that attitude control logic function and hardware interface is designed as expected with closed loop simulation. The VDS is one of major equipments for performing FBT and consists of software and hardware parts. The VDS operates in VME environments with target board, several commercial boards and custom boards based on the VxWorks real time operating system. In order to make time synchronization between VDS and satellite on-board processor, high reliable semaphore was implemented to make synchronization with the interrupt signal from on-board processor. In this paper, the real-time operating environment used on VDS equipment is introduced, and the hardware and software configurations of VDS summarized in the systematic point of view. Also, we try to figure out the operational concept of VDS and AOCS verification test method with close-loop simulation.

  • PDF

Monitoring System for TV Advertisement Using Watermark (워터마크를 이용한 TV방송 광고모니터링 시스템)

  • Shin, Dong-Hwan;Kim, Geung-Sun;Kim, Jong-Weon;Choi, Jong-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.15-18
    • /
    • 2004
  • In this paper, it is implemented the monitoring system for TV advertisement using video watermark. The functions of an advertisement monitoring system are automatically monitoring for the time, length, and index of the on-air advertisement, saving the log data, and reporting the monitoring result. The performance of the video watermark used in this paper is tested for TV advertisement monitoring. This test includes LAB test and field test. LAB test is done in laboratory environment and field test in actually broadcasting environment. LAB test includes PSNR, distortion measure in image, and the watermark detection rate in the various attack environment such as AD/DA(analog to digital and digital to analog) conversion, noise addition, and MPEG compression The result of LAB test is good for the TV advertisement monitoring. KOBACO and SBS are participated in the field test. The watermark detection rate is 100% in both the real-time processing and the saved file processing. The average deviation of the watermark detection time is 0.2 second, which is good because the permissible average error is 0.5 second.

  • PDF

A Study on the design of Video Watermarking System for TV Advertisement Monitoring (TV광고 모니터링을 위한 비디오 워터마킹 시스템의 설계에 관한 연구)

  • Shin, Dong-Hwan;Kim, Sung-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.206-213
    • /
    • 2007
  • In this paper, The monitoring system for TV advertisement is implemented using video watermark. The functions of the advertisement monitoring system are monitoring the time, length, and index of the on-air advertisement, saving the log data, and reporting the monitoring result. The performance of the video watermark used in this paper is tested for TV advertisement monitoring. This test includes LAB test and field test. LAB test is done in laboratory environment and field test in actually broadcasting environment. LAB test includes PSNR, distortion measure in image, and the watermark detection rate in the various attack environment such as AD/DA(analog to digital and digital to analog) conversion, noise addition, and MPEG compression. The result of LAB test is good for the TV advertisement monitoring. KOBACO and SBS are participated in the field test. The watermark detection rate is 100% in both the real-time processing and the saved the processing. The average deviation of the watermark detection time is 0.2 second, which is good because the permissible average error is 0.5 second.