• Title/Summary/Keyword: test structures

Search Result 5,987, Processing Time 0.032 seconds

(WDF-Based Derivation of Two-Type-Interlaced Structure for Low-Sensitivity Digital Filter Realizations (WDF에 의거한 저면감도 영향교대 필터구조의 유도)

  • 임일택;이병기
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.8
    • /
    • pp.20-30
    • /
    • 1994
  • The lossless bounded real(LBR) two-pair cascade structure is one of the exiting low-sensitivity digital filter structures such as wave digital filters(WDFs) orthogonal filters. They are known to have the same structures which are composed of canonic building blocks interconnected to each other. The LBR two-pair cascade filters amount to describing in a unified manner the existing canonic low-sensitivity filters in terms of transfer matrices and chain matrices. However the existing structures have somewhat degraded low-sensitivity performance because they include dependent parameters within their structures. In this paper we propose a filter structure called “two-type-interlaced(TTI) structure.” eliminating such problem completely. This structures can be viewed as the WDFs of analog ladder circuits. As ladder circuits are obtained by cascading Brune sections and merging neighboring inductors or capacitors. so TTI structures at e obtained by cascading Type 3 LBR two-pairs and merging neighboring Type 1 LBR two-pairs. Next, a test procedure called “LBR test” is also presented in this paper. which determines whether of not the quantized TTI structure is stable . If it is unstable we can fine-tune the quantized parameters to make the overall structure stable. Therefore we can solve the dependent parameter problem completely with TTI structure along with LBR test. test.

  • PDF

Application of Acoustic Emission Technique for Detection of Crack in Notched Concrete Beams (노치가 있는 콘크리트 보에서 균열검출을 위한 음향방출기법의 적용)

  • Jin, Chi-Sub;Lee, Nae-Chul;Shin, Dong-lk;Kwon, Sung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.4
    • /
    • pp.215-220
    • /
    • 1999
  • Concrete micro-cracks that are grown while the structures are under construction or in service, propagate gradually or rapidly by external forces and environmental effects. As described above, almost concrete structures generally have cracks, so for the safety and durability of structures, studies to detect cracks using nondestructive tests have been treated in great deal. The purpose of this study is to evaluate characteristics of AE signals detected from notched concrete beams bending test with different loading using one of nondestructive test, Acoustic Emission (AE) method. Furthermore this study predicts the location of initial crack and measures direction of crack propagation for on-line monitoring before the crack really grows in structures by using two-dimensional AE source location based on rectangular method with three-point bending test. This will allow efficient maintenance of concrete structures through monitoring of internal cracking based on acoustic emission method.

  • PDF

Compatibility Test of the Capsule with Cone Shape Bottom Guide Structures to the HANARO Reactor (원추형 하단부 구조를 갖는 캡슐의 하나로와의 양립성시험)

  • Choi, M.H.;Cho, M.S.;Choo, K.N.;Park, S.J.;Kim, B.G.;Kang, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.444-449
    • /
    • 2004
  • The design modification of bottom guide structures of the instrumented capsule, which is used for the irradiation test in the HANARO reactor, was required because of the trouble of the bottom guide arm's pin during irradiation. The previous structure with 3-pin arms was changed into the cone shape of one body. The specimens of the bottom end cap ring with three different sizes (${\Phi}68/70/72mm$) were designed and manufactured. The out-pile tests for the capsule with previous and new three bottom guide structures were performed in the one-channel flow test facilities. In order to evaluate the compatibility with HANARO and the structural integrity of the capsule, a loading/unloading, a pressure drop, a thermal performance, a vibration, and an endurance test were conducted. From out-pile test results, the capsule with the cone shape bottom guide structures was found to be more stable than the previous structure and the optimized size of the bottom guide structure selected was 70mm in diameter. It is expected that the new bottom guide structures will be applicable to all material and special capsules which will be designed and manufactured for the irradiation tests in the future.

  • PDF

After-fracture behaviour of steel-concrete composite twin I-girder bridges: An experimental study

  • Lin, Weiwei
    • Steel and Composite Structures
    • /
    • v.42 no.1
    • /
    • pp.139-149
    • /
    • 2022
  • To simplify the design and reduce the construction cost of traditional multi-girder structural systems, twin I-girder structures are widely used in many countries in recent years. Due to the concern on post-fracture redundancy, however, twin girder bridges are currently classified as fracture critical structures in AASHTO specifications for highway bridges. To investigate the after-fracture behavior of such structures, a composite steel and concrete twin girder specimen was built and an artificial fracture through the web and the bottom flange was created on one main girder. The static loading test was performed to investigate its mechanical performance after a severe fracture occurred on the main girder. Applied load and vertical displacement curves, and the applied load versus strain relationships at key sections were measured. To investigate the load distribution and transfer capacities between two steel girders, the normal strain development on crossbeams was also measured during the loading test. In addition, both shear and normal strains of studs were also measured in the loading test to explore the behavior of shear connectors in such bridges. The functions and structural performance of structural members and possible load transfer paths after main girder fractures in such bridges were also discussed. The test results indicate in this study that a typical twin I-girder can resist a general fracture on one of its two main girders. The presented results can provide references for post-fracture performance and optimization for the design of twin I-girder bridges and similar structures.

Compression and Bending Test for the Stiffness of Composite Lattice Subelement (복합재 격자 구조의 강성 평가를 위한 Subelement의 압축, 굽힘 시험)

  • Jeon, Min-Hyeok;Kang, Min-Song;Kim, In-Gul;Kim, Mun-Guk;Go, Eun-Su;Lee, Sang-Woo
    • Composites Research
    • /
    • v.30 no.6
    • /
    • pp.331-337
    • /
    • 2017
  • The composite lattice structures have advantages of high specific stiffness and strength and are mainly applied to the structures of launch vehicles that carry the compressive load. However, since these structures are manufactured by filament winding technology, there are some defects and voids found in the knots. For these reasons, the stiffness and strength of the lattice structures have to be compared with finite element model for predicting design load. But, the full scale test is difficult because time and space are limited and the shape of structure is complex, and hence the simple and reliable test methods for examination of stiffness are needed. In this paper, subelements of composite lattice structures were prepared and compressive and bending test were conducted for examination of stiffness of helical and hoop rib. Test methods for subelements of composite lattice structures that has curved and twisted shape were supposed and compared with finite element analysis results.

An experimental study on the corrosive behaviour of Rolling stock structures (차량구조물의 부식 거동에 관한 실험적 연구)

  • Oh Chang-Rok;Kim Yong-Ki;Jang Se-Ky;Goo Byeong-Chun
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.346-351
    • /
    • 2004
  • The present paper describes an experimental study on the corrosive behaviour of Rolling stock structures. It is important to predict corrosive behaviour of rolling stock structures for safe service and to know relation between corrosion and fatigue life. This paper practiced atmospheric corrosion test of SS400 and SM490A. This study practiced an additional test on the influence of heat-treatment. This test will examine corrosive behaviour and differences of SS400 and SM490A.

  • PDF

Vibration Performance test and static load test of body flat freight car (평판화차의 차체 정하중시험 및 진동성능시험)

  • Hong Jai-Sung;Ham Young-Sam;Kim Gil-Dong;Han Suk-Youn;Cha Ji-Bum
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.700-705
    • /
    • 2003
  • The object of this study is to ensure the stability of flat freight cars using vibration performance test and static load test of body structures. We examined the flat car though static load test and dynamic characteristics analysis related traveling stability and vibration performance. In the results of static load test of body structures for flat car, all structures satisfied allowable stress of materials. The vibration performance test was satisfied with allowable standards. Although flat car exceed speed a little at some speed interval, it was estimated that the cause was not cars but rail.

  • PDF

Shaking Table Test for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment (내진설계 되지 않은 공동주택의 진동대 실험에 의한 내진성능 평가)

  • Chung, Lan;Lee, Joung-Woo;Park, Tae-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.721-728
    • /
    • 2006
  • Earthquakes are reported thai building structures have been colossal damaged, but before 1988 designed structures which were not applicate seismic design code have no seismic performance. Especially, for the apartment structures were indicated that it have no resist wall element of earthquake before 1988 designed structures. We have to evaluate for seismic performance this structures, therefore it will be retrofitted for seismic index sufficient structures. We performed seismic performance evaluation for model structures by MIDAS which is general structure analysis software. In this study, it was performed shaking table test to evaluate model structure which is reinforcement concrete and 5 floors for seismic performance index. We made specimens by similar's law and tested shaking table test. In the shaking table test it is not performed prototype model test because of space and equipment condition. So we had made scale-down model for 1/5 by similar's law. That's why it needs for the evaluation of performance. However, it is not possible to do an experiment of prototype owing to the shortage of space and the limit of an experimental instrument in the shaking table test. Then, modeling and reducing the part of prototype do the experiment. In this experiment a shaking table test is done and seismic performance of model structures is evaluated by using similitude laws for scale down specimen. As a result it is proved that non-seismic design structures need to retrofit since seismic performance shows life safe grade in 0.12g of an earthquake.

A Study on the Proposal of Strength Presumption Equation of Concrete Using Rebound Test and Aging Effects of Underground Structures (지하구조물 공용년수를 고려한 반발경도법에 의한 강도추정식의 제안)

  • Na, Sung Oak;Yoon, Tae Gook;Rhee, Jong Woo
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.59-65
    • /
    • 2009
  • The rebound test using Schmidt hammer is most popular method to estimate strength of concrete. However, this method is inappropriate for Seoul Metro underground structures due to unsuitable aging effects. Consequently, the strength presumption equation of underground structures is proposed according to the correlation of uniaxial compressive strength, rebound test results and age of concrete. To achieve this, the results of in-depth inspection of Seoul Metro underground structures performed annually for last 8 years was anlayed.

  • PDF

An experimental study on structural behaviour of the MMA double wide flanged GFRP pipe composite structures (II) (MMA 이중 플랜지를 갖는 GFRP 복합관 구조거동에 관한 실험 연구 (II))

  • Ji, Hyo-Seon;Mamdouh, El-Badry
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.3
    • /
    • pp.50-61
    • /
    • 2015
  • This paper presents on the structural behavior of the the methyl methacrylate monomer (MMA) double wide flanged the glass fiber-reinforced polymer(GFRP) pipe composite structures for the manhole raise. The evaluation of structural performance on this composite structure was conducted by the axial load, fatigue load, and ultimate load test. The assessment indicates that the MMA double wide flanged GFRP pipe composite structures was confirmed safety, durability and reliability in result as expected. It was found that this composite structure was able to short working times to around 30-50% and construction costs to around 10-23% with compare other construction methods. Also, environmental pollution and civil complaints will be prevented because there will be no longer any noises, vibrations, dust, or construction wastes.