• Title/Summary/Keyword: test standard

Search Result 8,549, Processing Time 0.041 seconds

SERO-EPIDEMIOLOGICAL STUDY OF BRUCELLOSIS AMONG GOATS AND SHEEP AT PESHAWAR DISTRICT

  • Ghani, M.;Siraj, M.;Zeb, A.;Naeem, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제8권5호
    • /
    • pp.489-494
    • /
    • 1995
  • Sero-epidemiological study was carried out to observe the prevalence of brucellosis in 500 slaughtered as well as in 500 healthy animals in Peshawar district of N.W.F.P. All serum samples were subjected to four serological tests i.e. Standard Plate Test (SPT), Standard Tube Test (STT), Rivanol Test (RV) and 2, Mercapto-Ethanol Test (2, ME). The incidence of disease in 500 healthy animals tested by standard plate test, standard tube test, rivanol test and 2, Mercapto-ethanol test, was 2.8%, 1.8%, 1.6% and 1.2% respectively. While the incidence of brucellosis in 500 slaughter animals from Peshawar abattoir was 3.0%, 2.2%, 2.00% and 1.2% by standard plate test, standard tube test, rivanol test and 2, Mercapto-ethanol test The disease prevalence was higher in slaughtered animals as compared to healthy animals. The disease was more common in goats than sheep, also more prevalence in aged female than younger stocks. The efficacy of SPT was found more effective as compared to STT, RV, and 2, ME tests both in slaughtered as well as apparently healthy animals at Peshawar district. Standard Plate test detected 2.9%, Standard Tube test 2.0%, Rivanol test 1.8% and 2, Mercapto-ethanol test detected 1.2% positive cases in slaughtered as well as in healthy animals. So the Standard Plate Test was found to be more reliable, sensitive, and easy to performed.

The Study on Test Standard for Measuring AI Literacy

  • Mi-Young Ryu;Seon-Kwan Han
    • 한국컴퓨터정보학회논문지
    • /
    • 제28권7호
    • /
    • pp.39-46
    • /
    • 2023
  • 본 연구는 인공지능 소양 능력의 측정을 위한 검사 기준의 설계와 개발을 목적으로 한다. 선행연구와 전문가 FGI를 통해 AI 소양의 핵심 영역을 선정하고 세부 기준을 설계하였다. 검사 기준의 영역은 AI의 개념, 실제와 영향 3가지로 구분하고 세부 항목은 AI의 개념 33문항, AI의 실제 13문항, AI의 영향 15문항으로 구성하였다. 검사 기준의 타당성 확보를 위해 2번에 걸친 전문가 타당도 검사를 실시하여 검사 기준을 수정, 보완하였다. 최종 AI소양 검사 기준은 총 30문항으로 개발하였다. 본 연구에서 개발된 AI소양 검사 기준은 AI소양 능력 측정을 위한 자기 체크리스트나 AI역량 검사 문항을 개발하는 중요한 도구가 되기를 기대한다.

Novel Hierarchical Test Architecture for SOC Test Methodology Using IEEE Test Standards

  • Han, Dong-Kwan;Lee, Yong;Kang, Sung-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권3호
    • /
    • pp.293-296
    • /
    • 2012
  • SOC test methodology in ultra deep submicron (UDSM) technology with reasonable test time and cost has begun to satisfy high quality and reliability of the product. A novel hierarchical test architecture using IEEE standard 1149.1, 1149.7 and 1500 compliant facilities is proposed for the purpose of supporting flexible test environment to ensure SOC test methodology. Each embedded core in a system-on- a-chip (SOC) is controlled by test access ports (TAP) and TAP controller of IEEE standard 1149.1 as well as tested using IEEE standard 1500. An SOC device including TAPed cores is hierarchically organized by IEEE standard 1149.7 in wafer and chip level. As a result, it is possible to select/deselect all cores embedded in an SOC flexibly and reduce test cost dramatically using star scan topology.

항공기 실측 진동 데이터를 이용한 환경시험 규격 생성 연구 (Development of Environmental Test Specifications for Aircraft Using Measured Vibration Data)

  • 김충현;송기혁
    • 한국군사과학기술학회지
    • /
    • 제24권3호
    • /
    • pp.302-308
    • /
    • 2021
  • Developers generally use test standards suggested by military standards such as MIL-STD-810G when performing vibration tests in the materiel development. However, according to MIL-STD-810G, it is recommended to test by tailoring the test standard suitable for the developed materiel, and it is specified to apply the suggested test standard only when there is difficulty in tailoring. In addition, the test standards presented by MIL-STD-810G are standards created under operating conditions different from the actual operating environment of each developed materiel, so the test according to this standard may be excessive or understated. Therefore, the developer must create an appropriate vibration test standard for the developed materiel as similar to the operating conditions as possible. In this paper, the procedure for creating the functional test standard and durability test standard suitable for the operating environment of the equipment to be mounted on the propeller aircraft under development is described, and the created standard is introduced.

표준관입시험 간격 결정을 위한 개념적 알고리즘 (A Conceptual Algorithm for Determining the Spacing of Standard Penetration Test Spots.)

  • 하비마나;이동훈;한경보;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.185-186
    • /
    • 2015
  • The Standard penetration test determines the type of soil according to soil bearing capacity, and this classifies the subsoil into many layers. Construction project managers are willing to know the depth of the present types of subsoil on site in order to make plans on earthwork stage during excavation. However the standard penetration test may not provide accurate information on subsoil type due to incorrect spacing. To solve this problem, this study propose a conceptual algorithm for determining the spacing of standard penetration test spots to essentially tests relevant locations on which to be applied the standard penetration test. This provides the acquirement of the accurate layered model volume of earthwork revised into geological columnar section. This algorithm will determine the appropriate standard penetration test spots spacing on a given size of site to optimize the accuracy of the earthwork volume, time and cost.

  • PDF

국방정보기술표준 일반 표준적합성시험 프레임워크 및 방법론 연구 (A Study on General-Standard Conformance Test Framework and Methodology of Defense Information Technical Standard)

  • 서민우
    • 한국군사과학기술학회지
    • /
    • 제19권6호
    • /
    • pp.744-751
    • /
    • 2016
  • Interoperability tests are required to determine whether network-based defense systems successfully share and exchange certain services, information, and data. We must examine various aspects of interoperability. The DITA (Defense Information Technical stAndard) is the basis for interoperability. However, DITA is being applied to the defense system in a state that the standard test methods and procedures are not established. And there is no test method and procedure of the DITA well applicable to military weapons systems or information systems. Therefore, in this paper, we propose a framework that includes procedures, methodologies, so as to test whether a standard is applied to the DITA in terms of Standard Conformance Test.

캘리포니아 표준 테스트 방법을 사용한 압전 발판의 경제성 분석 (Economic Analysis of the Piezoelectric Power using the California Standard Test)

  • 정순성
    • 동력기계공학회지
    • /
    • 제21권4호
    • /
    • pp.51-56
    • /
    • 2017
  • The purpose of this study is to suggest economic analysis for piezoelectric power. Economic analysis method uses california standard test. Perspectives of california standard test is participant test, ratepayer impact measure test, program administrator cost test and total resource cost test. This study identifies the cost and benefit components. This study identifies benefit-cost calculation procedures from four test : participant test, ratepayer impact measure test, program administrator cost test and total resource cost test. In the economic analysis, the order of benefit cost ratio in piezoelectric power shows total resource cost test, program administrator cost test, ratepayer impact measure test and participant test.

누전차단기의 EMC 조합서지 내성 강화를 위한 방안 (The Method of Reinforcing the Immunity of Residual Current Circuit Breaker for the EMC Composite Surge)

  • 김재철;한윤탁;김언석;설규환;강장규;문종필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권8호
    • /
    • pp.322-328
    • /
    • 2006
  • In this paper, The impulse un-tripping characteristics and the electro magnetic compatibility characteristics are compared with each other. The performance of impulse un-tripping test exists at domestic standard (KSC 4613). However test items are insufficient because the more test items such as EMC exist at international standard (IEC). Also, Electric Appliances Safety Certificate has taken the certificate test since July 2004 in Korea but did not confirm the EMC performance for RCCBs made in Korea. Thus, in this paper, We experiment with Oscillatory waves immunity test and the 7 EMC tests for 32 RCCBs of 4 types (mini, home standard, plug, outlet) for 16 brands according to IEC standard 61009-1 and 61008-1. As a result, 24 RCCBs proved to be poor for surge immunity test. However the RCCBs operating incorrectly for surge immunity test operate correctly for oscillatory waves immunity test. Thus, the correlation between oscillatory waves immunity test and EMC test is little and standard for compatibility of combination surge at IEC 61000-4-5 should be added to KS standard as soon as possible.

시약 변경 시 모집단 분포 추이에 따른 결과 분석 (Result Analysis according to Population Distribution Trends when Reagents are Changed)

  • 박혜미;임수연;유선희;이선호
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.55-61
    • /
    • 2023
  • Purpose In this study, the monthly population distribution was calculated for statistical verification of 10 tests (CA19-9, CA15-3, testosterone, PTH, calcitonin, AFP, CEA, CA72-4, PSA, estradiol) with changed reagents, and the trend of change By comparing and analyzing the results, we want to verify the accuracy of the results and improve the reliability of the test. Materials and Methods From June 2021 to February 2023, for the 10 items in which the reagent was changed, the monthly percentage and standard deviation index before and after the reagent change were compared, respectively. At this time, the reference value was arbitrarily set for the comparison group in consideration of the reference value of the test item, and the groups were subdivided and compared, and the standard deviation index allowed range was -2.0 or more and 2.0 or less. Results For CA19-9, CA15-3, AFP, CEA, and calcitonin 5 test items, the change in monthly ratio in all test sections before and after the reagent change was kept constant. On the other hand, for CA72-4, PSA, testosterone, PTH, and estradiol items, the standard deviation index exceeded the acceptable standard after changing the reagent. CA72-4 test items showed an increasing trend in standard deviation index in the test section exceeding the reference value. In the case of the PSA test item, the maintenance ratio of 0.04 ng/mL was significantly decreased after changing the reagent. The testosterone test item had a standard deviation index of -2.5 in the test section exceeding 10.1 ng/mL after changing the reagent, and the standard deviation index of the PTH test item was out of the acceptable range in all test sections. It was confirmed that the estradiol test item showed an overall increase in the result value. Conclusion Through this study, the continuity and accuracy of the test results could be verified. It is considered that the stability of the test can be secured by analyzing the factors affecting the test result and solving the cause for the test item whose standard deviation index is out of the acceptable standard.

  • PDF

BF인증을 위한 바닥 마감재 미끄럼 성능기준 및 측정방법에 대한 연구 (A Study on Floor Slip Resistance Standard and Test Method for BF Certification)

  • 신동홍;성기창;박광재
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.75-83
    • /
    • 2019
  • Purpose: There are no clear criteria for slip performance in the BF certification process, so the evaluator relies on subjective judgments depending on the field situation. Physical criteria for determining the slip performance of various floor finishes are not clear. C.S.R., the only criterion currently being used to check slip performance, may raise questions about its coverage, feasibility and reliability. Method: For an analysis of domestic standards and status, KS L 1001, KS M 3510, and KS F 2375. External standards are analyzed for ADA Standard, ANSI Standard, and BS EN Standard. Analyze the test methods and evaluation criteria of O-Y-PSM, BPT, and the dynamic slip resistance test used in these criteria. It also presents an improvement plan for the rational presentation of standards. Results: To date, various kinds of test methods and measuring devices of the slip resistance coefficient have been developed, but there are not many ways to trust useful results related to user safety. Reliability and thoroughly verified test methods and criteria should be used to assess the slip performance of the floor. In order to improve the standard for the evaluation of slip performance in Korea, the existing standard should first be raised to the same level as the overseas standard, and the application of the discriminatory standard should be applied considering the characteristics and usage patterns of each space. Implication: Currently, Korean standards propose various test methods, but the proper use of test methods, scope and assessment criteria are not established, so improvement of the comprehensive standard is necessary.