• Title/Summary/Keyword: test site

Search Result 3,382, Processing Time 0.029 seconds

Site Attenuations of the KSRI Open Area Test Site (야외시험장의 시험장감쇠량)

  • 정연춘;강태원;강인구;김기채;김정환;정낙삼
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.1 no.1
    • /
    • pp.14-19
    • /
    • 1990
  • A site attenuation measurement system has been developed and evaluated. The system uses selfresonant dipole antennas and baluns. Using the system we measured the site attenuations of the KSRI open area test site. The measured results agree with calculated data within $\pm$3dB , so the site can be used for EMI/EMC measurements and antenna calibrations.

  • PDF

Efficient Multi-site Testing Using ATE Channel Sharing

  • Eom, Kyoung-Woon;Han, Dong-Kwan;Lee, Yong;Kim, Hak-Song;Kang, Sungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.3
    • /
    • pp.259-262
    • /
    • 2013
  • Multi-site testing is considered as a solution to reduce test costs. This paper presents a new channel sharing architecture that enables I/O pins to share automatic test equipment (ATE) channels using simple circuitry such as tri-state buffers, AND gates, and multiple-input signature registers (MISR). The main advantage of the proposed architecture is that it is implemented on probe cards and does not require any additional circuitry on a target device under test (DUT). In addition, the proposed architecture can perform DC parametric testing of the DUT such as leakage testing, even if the different DUTs share the same ATE channels. The simulation results show that the proposed architecture is very efficient and is applicable to both wafer testing and package testing.

Factors Related to Surgical Site Infections in Patients Undergoing General Surgery (일반외과 환자의 수술부위 감염 관련 요인 분석)

  • Ahn You-Jin;Sohng Kyeong-Yae
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.12 no.1
    • /
    • pp.113-120
    • /
    • 2005
  • Purpose: To identify risk factors for surgical site infections in patients undergoing general surgery, to analyze the prolonged hospital stay and extra cost for antibiotics, and to provide basic data for control of surgical site infections. Method: Surgical site infection was defined using the definition of the CDC and the data were analyzed by $x^2$-test and unpaired t-test. Results: The prevalence of surgical site infections was 9.7%, and it was related to wound class, duration of operation, number of operations, whether the operation was an emergency, trauma, drains, preoperative stays, presence of remote infection during operative period, and previous history of recent surgery. The mean duration for post-operative stay when a surgical site infection occurred was 9.5 days and in 56.9 % of the patients the surgical site infection appeared 7 days after the operation. Post-operative stays for infected patients were 20.3 days longer than that of uninfected patients. The mean cost of antibiotics for infected patients was higher than that for uninfected patients by 561,067 won per person. Conclusion: Surgical site infection results in an increased length of stay and extra-cost, thus, hospitals need to create strategies to reduce nosocomial infections through effective infection surveillance and by considering factors related to surgical site infections.

  • PDF

A Study on e-Trade Activity Relationship Commitment of Trade Potal Site 6C's (무역 포털사이트 6C's의 관계결속이 전자무역 활용에 미치는 연구)

  • Lee, Je-Hong
    • International Commerce and Information Review
    • /
    • v.7 no.1
    • /
    • pp.121-144
    • /
    • 2005
  • This paper describes a theoretical model for investigating the relationship commitment of trade portal site 6C's. This research is the first to empirical test the causal relationships in Trade portal site. The relationship commitment for e-Trade portal site are tested here using data from 195 samples. Research methodology used in this study was mainly survey and questionnaire. Structural equation model is used in the hypotheses test. the results support all hypotheses involving hypothesis 1 and 6. The major finding of this paper would be summarized as followed: 1) Perceived relationship commitment of e-Trade site 6C's is positively related to contents, community, communication, customization in e-trade activity level and activity range of trade practical 2) Perceived commerce of electronic trade site is negatively related to the relationship commitment of trade companies. 3) Perceived e-trade site in electronic trade connection is positively related to the re-activity intention. In examining the relationships commitment of the factors, e-trade potal 6C's show in significantly by Contents, Community, Communication, Customization, Re-activity intention, but that show in not significantly by Commerce factor.

  • PDF

유류오염토양 복원을 위한 설계인자 선정에 관한 연구

  • 조장환;전권호;서창일;박정구
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.293-296
    • /
    • 2004
  • The objective of this study was to decide the designing factor for remediaton of the contaminated site. The soil and ground-water samples were analyzed and hydro- geological characteristics was assayed for the survey of pollution level. Also air-permeability test and MPN(most probable number) test were conducted for selecting the designing factor. The contaminants were mainly found in north-west part of the site and were expected to move toward the south. Ex-situ technology was expected more useful than in-situ one with the results of air-permeability test saying that air permeability was relatively low. Additional microbes were expected for remediation efficiency because residual microbes were loosely populated. The choosing of the designing factor was requisite for remediation of contaminated site.

  • PDF

A Site Application of the Revealing High Early Strength Concrete (조기강도 발현형 콘크리트의 현장 적용성 연구)

  • Kim Gyu Dong;Lee Seung Hoon;Sohn Yu Shin;Kim Han Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.560-563
    • /
    • 2004
  • This study reports the site application of concrete using AE Water Reducing Agent of Early-Strength Type. According to the lab test results, we have made plans of batch plant pilot test, and we have analyzed the erly aged compressive strength and workability of the concrete. We applied the early-strength development concrete to the construction site. We accomplished the slump test in order to evaluate the workablity and air contents, we made site curing mold to evaluate the early strength of members. As a result, we judgeed the superior property of early strength development of the concrete, and thought that we can reduce the time of form stripping more $40\%$ than ordinary strength concrete. We thought that we can reduce the term of works and finally we can accomplish the economical construction.

  • PDF

Field Application of New Seismic Site Characterization Using HWAW(Harmonic Wavelet Analysis of Wave) Method (HWAW(Harmonic Wavelet Analysis of Wave) 방법을 이용한 새로운 탄성파 지반조사기법의 현장 적용)

  • 박형춘;김동수;이병식
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.51-59
    • /
    • 2004
  • The evaluation of shear modulus is very important in various fields of civil engineering. In this paper, the site characterization method using HWAW method is applied to determine shear wave velocity profile of two test sites in order to verify the field applicability of HWAW method. Shear wave velocity profiles by HWAW method are compared with shear wave velocity profiles by SASW test and PS-Suspension Logging test. Through field applications, it is shown that HWAW method can minimize the effect of noise and lateral non-homogeneity of the site and determine detailed local shear wave velocity profile of site.

Application of single-well push-drift-pull tests using dual tracers (SF6 and salt) for designing CO2 leakage monitoring network at the environmental impact test site in Korea

  • Kim, Hong-Hyun;Lee, Seong-Sun;Ha, Seung-Wook;Lee, Kang-Kun
    • Geosciences Journal
    • /
    • v.22 no.6
    • /
    • pp.1041-1052
    • /
    • 2018
  • A single-well push-drift-pull tracer test using two different tracers ($SF_6$ and salt) was performed at the Environmental Impact Test (EIT) site to determine suitable locations for monitoring wells and arrange them prior to artificial $CO_2$ injection and leak tests. Local-scale estimates of hydraulic properties (linear groundwater velocity and effective porosity) were obtained at the study site by the tracer test with two tracers. The mass recovery percentage of the volatile tracer ($SF_6$) was lower than that of the non-volatile tracer (salt) and increased drift time may make degassing of $SF_6$ intensified. The $CO_2$ leakage monitoring results for both unsaturated and saturated zones suggest that the $CO_2$ monitoring points should be located near points at which a high concentration gradient is expected. Based on the estimated hydraulic properties and tracer mass recovery rates, an optimal $CO_2$ monitoring network including boreholes for monitoring the unsaturated zone was constructed at the study site.

Development of Conformance Test Tools for Terrestrial DMB Broadcast Web Site Services (지상파 DMB 방송웹사이트 서비스 송수신 정합 시험 도구 개발)

  • Kim, Yong-Han;Moon, Su-Han;Chae, Young-Seok
    • Journal of Broadcast Engineering
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2007
  • In this paper, we presents conformance test tools for the broadcast web site (BWS) service which is one of the data services for terrestrial digital multimedia broadcasting (T-DMB). First, the methodology for the conformance test is established for both transmitters and receivers of T-DMB BWS services. The test tools consist of three parts: BWS bitstream analyzer, BWS reference decoder (software) module, and BWS test bitstreams. For testing transmitted BWS bitstreams, we developed the bitstream analyzer. For testing BWS receivers, we developed the reference Ifecoder module and created the test bitstreams. Actually the bitstream analyzer developed in this paper was used for the verification of the test bitstreams. The same test bitstreams are fed to a BWS decoder module under test and the reference decoder module and the results from the two are compared for verification. The test tools can be used for the test of all the protocol and textual/image specifications related to BWS including MOT protocol, HTML, PNG, MNG, JPEG, and Ecma Script.

Pilot Scale Feasibility Test of In-situ Soil Flushing by using 'Tween 80' Solution at Low Concentration for the Xylene Contaminated Site

  • Um, Jae-Yeon;Lee, Gyusang;Song, Sung-Ho;Hong, Sunwook;Lee, Minhee
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.6
    • /
    • pp.38-47
    • /
    • 2013
  • This study was performed to identify the optimal operating conditions and to evaluate the xylene removal efficiency, applying in-situ soil flushing with the low concentrated solution of 'Tween 80' at the xylene contaminated site. The pilot scale test site ($5m{\times}5m{\times}3m$), was mainly composed of 'sandy loam', with the average hydraulic conductivity of $9.1{\times}10^{-4}cm\;s^{-1}$. The average xylene concentration of the site was 42.1 mg $kg^{-1}$, which was more than 2.5 times higher than Korea soil pollution warning limit (15 mg $kg^{-1}$). For the soil flushing, 7,800 L of 0.1~0.2% surfactant solution was injected into three injection wells at the average injection time of 9 hr $d^{-1}$ for 10 days, followed by the additional only groundwater injection of 6,000 L. The same amount of the effluent solution was extracted from three extraction wells. From the analysis for xylene concentration of all effluent at 3 extraction wells, total 166 g of xylene was removed by in-situ surfactant flushing. Even though the residual xylene concentrations of 7 soil sampling locations in the test site were different due to the soil heterogeneity, from the comparison of xylene concentration at 7 locations before/after the feasibility test, 53.9% of the initial xylene in the site was removed from three extraction wells (mainly Ext-N and Ext-M well). The results showed that the in-situ soil flushing by using low concentrated 'Tween 80' solution had a great potential to remediate the xylene contaminated site.