• 제목/요약/키워드: test methods

검색결과 27,300건 처리시간 0.05초

Experimental and analytical behaviour of composite slabs

  • Lopes, Emanuel;Simoes, Rui
    • Steel and Composite Structures
    • /
    • 제8권5호
    • /
    • pp.361-388
    • /
    • 2008
  • The Eurocode 4 presents some negative aspects in the design of composite slabs by the m-k Method or the Partial Connection Method. On one hand, the component chemical adherence is not accounted for in the connection between the profiled steel sheet and the concrete. On the other hand, the application of these methods requires some fitting parameters that must be determined by full scale tests. In this paper, the Eurocode 4 methods are compared with a method developed at the Federal Polytechnic School of Lausanne, based on pullout tests, which can be a valid alternative. Hence, in order to calculate the necessary parameters for the three methods, several tests have been performed such as the full scale test described in Eurocode 4 and pull-out tests. This last type of tests is of small dimensions and implicates lower costs. Finally, a full-scale test of a steel-concrete composite slab with a generic loading is presented, with the goal of verifying the analytical formulation.

환경조건에 따른 에폭시로 접착된 석재의 부착성능평가 (Evaluation of Adhesion Performance of Stones Bonded with Epoxy according to Environmental Conditions)

  • 김영민;임건우;임창민;이건철;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.39-40
    • /
    • 2023
  • Recently, due to the advancement of buildings, finishing methods using stone are increasing. However, finishing methods are not standardized and rely on workers' arbitrary methods. In stone finishing, many building defects occur due to adhesion performance, so the adhesion performance of stones attached with epoxy is important. Therefore, in this study, the adhesion performance of stones attached with epoxy was evaluated by exposing them to various environments. As a result of the experiment, the test specimens exposed to thermal shock showed only 20% of the standard test specimens' adhesion performance, and the test specimens cured at high and low temperatures showed the standard test specimens. It was expressed in 65-80% of the test specimens. Therefore, the adhesion performance of stone using epoxy was found to be vulnerable to repeated harsh environments.

  • PDF

BF인증을 위한 바닥 마감재 미끄럼 성능기준 및 측정방법에 대한 연구 (A Study on Floor Slip Resistance Standard and Test Method for BF Certification)

  • 신동홍;성기창;박광재
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.75-83
    • /
    • 2019
  • Purpose: There are no clear criteria for slip performance in the BF certification process, so the evaluator relies on subjective judgments depending on the field situation. Physical criteria for determining the slip performance of various floor finishes are not clear. C.S.R., the only criterion currently being used to check slip performance, may raise questions about its coverage, feasibility and reliability. Method: For an analysis of domestic standards and status, KS L 1001, KS M 3510, and KS F 2375. External standards are analyzed for ADA Standard, ANSI Standard, and BS EN Standard. Analyze the test methods and evaluation criteria of O-Y-PSM, BPT, and the dynamic slip resistance test used in these criteria. It also presents an improvement plan for the rational presentation of standards. Results: To date, various kinds of test methods and measuring devices of the slip resistance coefficient have been developed, but there are not many ways to trust useful results related to user safety. Reliability and thoroughly verified test methods and criteria should be used to assess the slip performance of the floor. In order to improve the standard for the evaluation of slip performance in Korea, the existing standard should first be raised to the same level as the overseas standard, and the application of the discriminatory standard should be applied considering the characteristics and usage patterns of each space. Implication: Currently, Korean standards propose various test methods, but the proper use of test methods, scope and assessment criteria are not established, so improvement of the comprehensive standard is necessary.

컴퓨터 기반 평가 시스템의 보안성 강화 방안 (Security Improvement Methods for Computer-based Test Systems)

  • 김상현;조상영
    • 융합보안논문지
    • /
    • 제18권2호
    • /
    • pp.33-40
    • /
    • 2018
  • ICT 기술이 다양한 교육 분야에 적용되고 있지만 교육 평가 분야에 적용은 제한적이다. 컴퓨터 기반 평가는 기존의 지필평가에 비해 시간적/공간적 제약을 넘어서는 장점을 가지며 있지만 시험 당사자들의 부정행위에 취약하다. 본 논문에서는 컴퓨터 기반 평가의 보안성을 강화하기 위하여 실시간 모니터링 및 프로세스 관리 방안을 제안한다. 제안된 방식에서는 시험 화면을 주기적으로 캡처하여 교수 화면에 표시하여 실시간 감시가 가능하도록 하고 부정행위에 사용될 프로세스를 시험 전에 차단할 수 있도록 한다. 많은 학생들의 화면을 실시간으로 감시하기 위해서는 캡처된 원본 이미지의 효과적인 압축이 중요하다. 이를 위하여 이미지 압축 모듈의 사용, 해상도 약화, 재 압축의 3단계 압축 방식을 적용하였다. 이를 통하여 약 6MB의 원본 이미지를 약 3.8KB의 저장 이미지로 변환하였다. 부정 프로세스 차단 기능을 위하여 윈도우즈 API를 이용한 프로세스 추출 및 관리 기능을 사용하였다. 새로운 보안 강화 방안이 적용된 본 논문의 컴퓨터 기반 평가 시스템이 기존의 컴퓨터 기반평가 시스템과의 보안 관련 기능 비교를 통하여 우수함을 보여준다.

  • PDF

격납건물 종합누설률 예측방법 평가 (Evaluation of Prediction Methods for Containment Integrated Leakage Rate)

  • 양승옥;이광대;오응세
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.562-564
    • /
    • 2004
  • The containment leakage rate test performed on the nuclear power plants consists of following phases : pressurizing the containment, stabilizing the atmosphere, conducting a Type A test, conducting a verification test, depressurizing the containment. It takes more than 48 hours from the pressurization to the depressurization and the prediction of the results will help to prepare the next test phase. In this paper, to predict the leakage rate, the prediction methods based on the least square method are evaluated according to the input variables and the measurement period.

  • PDF

Regression Diagnostic Using Residual Plots

  • Oh, Kwang-Sik
    • Communications for Statistical Applications and Methods
    • /
    • 제8권2호
    • /
    • pp.311-317
    • /
    • 2001
  • It is necessary to check the linearity of selected covariates in regression diagnostics. There are various graphical methods using residual plots such as partial residual plots, augmented partial residual plots and combining conditional expectation and residual plots. In this paper, we propose the modified pseudolikelihood ratio test statistics based on these residual plots to test linearity of selected covariate. These test statistics which measure the distance between the nonparametric and parametric models are derived as a ratio of quadratic forms. The approximate distribution of these statistics is calculated numerically by using three moments. The power comparison of these statistics is given.

  • PDF

2중주파 합성시험회로의 TRV 패턴 분류 및 파라미터 계산 방법 (TRV Pattern Classification and Parameter Calculation Method for Double-Frequency Synthetic Test Circuit)

  • 이용한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.587-589
    • /
    • 2004
  • In this paper analytical pattern classification of TRV waves created by double-frequency synthetic test circuit was proposed. According to the classified patterns of the TRV wave, calculation methods of 3 reference lines and 4 parameters characterizing the TRV wave wire proposed. These methods can be utilized to optimize test facility and to standardize test quality.

  • PDF

일본내 연구동향(6편중 제 2편) (Some Aspects of Mechanical Test Methods for Advanced Composites)

  • Fukuda, Hiroshi;Wada, Atsushi
    • Composites Research
    • /
    • 제15권1호
    • /
    • pp.61-69
    • /
    • 2002
  • This paper review research activities of some mechanical test methods thor advanced composites which have been conducted in Fukuda laboratory. Tokyo University of Science. The subjects are (1) innovation and development of compression bending test. (2) mechanical-property evaluation of soft-core sandwich beam, and (3) loop test to measure the strength of monofilaments.

Non-Conservatism of Bonferroni-Adjusted Test

  • Jeon, Cyeong-Bae;Lee, Sung-Duck
    • Communications for Statistical Applications and Methods
    • /
    • 제8권1호
    • /
    • pp.219-227
    • /
    • 2001
  • Another approach (multi-parameter measurement method) of interlaboratory studies of test methods is presented. When the unrestricted normal likelihood for the fixed latent variable model is unbounded, we propose a me쇙 of restricting the parameter space by formulating realistic alternative hypothesis under which the likelihood is bounded. A simulation study verified the claim of conservatism of level of significance based on assumptions about central chi-square distributed test statistics and on Bonferroni approximations. We showed a randomization approach that furnished empirical significance levels would be better than a Bonferroni adjustment.

  • PDF

발전설비 고온부에서 사용되는 스터드 볼트의 교체기준 설명 (Establishment of Replacement Criteria for Stud Bolts using on High Temperature in the Power Plants)

  • 정남용;김문영
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.279-286
    • /
    • 2000
  • The stud bolts tend to degrade faster by high temperature(over 45$0^{\circ}C$). Therefore, replacement cycle inspection of stud bolts were carried out various method such as ultrasonic test(UT), magnetic test(MT), wobble test, visual test and hardness test. Especially, wobble test method has been applied to determine replacement evaluation criteria of stud bolt after long time operation. We applied three different methods on the three site and the obtained data are compared with the results from the evaluation methods. From the results, the replacement criteria for stud bolts under high temperature in power plants are proposed.

  • PDF