• Title/Summary/Keyword: test methods

Search Result 27,300, Processing Time 0.047 seconds

A Study on the Antibacterial Activity of Chitosan on the MRSA by the AATCC Test Method 100 and Modified AATCC Test Method 100

  • Choi, Jeong-Im;Jeon, Dong-Won
    • Fashion & Textile Research Journal
    • /
    • v.4 no.6
    • /
    • pp.557-563
    • /
    • 2002
  • Water-soluble chitosan and water-insoluble chitosan with molecular weight of 2,000,000, 500,000, 80,000, and 40,000 with more than 90%of degree of deacetylation were produced to test antibacterial activity of chitosan against a pathogenic bacteria, Methicillin Resistant Staphylococcus aureus(MRSA). the AATCC Test Method 100and Modified AATCC Test Method 100 were used to evaluate the antibacterial activity of chitosan. Antibacterial activity of chitosan/acetic acid solution was the same when they were tested by two different methods, but those of polyester fabrics treated with chitosan/acetic acid solution were different in different antibacterial test. So several problems were found in the experimental methods. The AATCC Test Method 100 seems that excessive nutrition exists in inoculum solution by quantitative analysis on the basis the result of antibacterial activity on chitosan/acetic acid solution and amount of chitosan attached to the surface of treated fabrics.

Determination of Sulfamethazine Using High Performance Liquid Chromatography and Several Screening Methods (HPLC 및 신속검출방법을 이용한 우유내 Sulfamethazine의 분석에 관한 연구)

  • 김철현;백승천;문지웅
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.1
    • /
    • pp.71-77
    • /
    • 1997
  • Sulfonamides, a therapeutically important group of antimicrobial drugs, are widely used to treat and prevent the acute systemic and skin infections in dairy cattle. They also pose an economic hazard through inhibition of growth of dairy starter cultures. This study was carried out to compare four screening methods for detection of sulfamethazine in milk and determine the positive milk sample by HPLC method. Sulfamethazine was used to spike at five levels of sulfamethazine. The Lac-Tek test and CharmII test were also consistent better than TTCII test and Delvo SP test in sulfamethazine detection. Analysis probabilities of obtaining a positive response with TTCII test and Delvo SP test assay at 50 ppb sulfamethazine level in milk samples were only 14%, 42% each. Whereas using the Lac-Tek test and CharmII test would have resulted in 100% identification of the five levels. Determination of sufamethazine using the HPLC method in the spiked milk were 10.64, 19.30, 30.76,38.83 and 50.23 ppb, respectively.

  • PDF

A Study on Comparison of Density Test Methods for Quality Control of Cement and Mineral Admixture (시멘트 및 혼화재의 품질관리를 위한 밀도 시험방법 비교 연구)

  • Jae-Seung, Lee;Sang-Kyun, Noh;Cheol, Park;Hong-Chul, Shin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.435-442
    • /
    • 2022
  • In this study, the density of KS L 5110 was compared with that of gas pycnometer and electronic densimeter for efficient density management of cement, blast furnace slag powder and fly ash. Correlation and usability according to the test method were reviewed, and based on the results of the experiment, the availability of alternative test methods was analyzed. As a result of the density test according to test methods, the density of cement, blast furnace slag powder and fly ash tended to decrease in the order of gas pycnometer, KS L 5110 and electronic densimeter. Because the volume range of the sample to be evaluated is different depending on test methods. The coefficient of determination R2 was in the range of 0.71 to 0.93, and the correlation according to test methods showed a relatively good correlation. If correction is applied through correlation, it is analyzed that alternative test methods can be used. As a result of the usability review considering the test procedure, measurement time and coefficient of variation, the gas pycnometer had the simplest test procedure and good reliability. In addition, it is expected that the reproducibility between the testers is relatively high because the skill is not greatly required.

The use of small scale model testing to compare connection methods of steel purlins

  • Urquhart, Stephen M.;Kavanagh, Kenneth T.
    • Structural Engineering and Mechanics
    • /
    • v.6 no.5
    • /
    • pp.571-582
    • /
    • 1998
  • Testing of steel roof purlins is usually performed on full scale models in large vacuum test rigs. To undertake a comparison between web cleat connected purlins and flange bolted purlins a series of tests were performed on a 1:4 small scale model vacuum test rig. Various modelling issues need to be addressed to ensure reasonable comparison with actual constructed roof framing methods but still be suitable for an economical comparison between the connection methods. Model test results were supported by, and found to be in reasonable agreement with, deflection predictions from computer models based on finite element methods. This paper discusses the testing methods adopted and the value of small scale model testing programs as a means of obtaining comparisons between framing options.

A Two Sample Test for Functional Data

  • Lee, Jong Soo;Cox, Dennis D.;Follen, Michele
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.2
    • /
    • pp.121-135
    • /
    • 2015
  • We consider testing equality of mean functions from two samples of functional data. A novel test based on the adaptive Neyman methodology applied to the Hotelling's T-squared statistic is proposed. Under the enlarged null hypothesis that the distributions of the two populations are the same, randomization methods are proposed to find a null distribution which gives accurate significance levels. An extensive simulation study is presented which shows that the proposed test works very well in comparison with several other methods under a variety of alternatives and is one of the best methods for all alternatives, whereas the other methods all show weak power at some alternatives. An application to a real-world data set demonstrates the applicability of the method.

Experimental validation of ASME strain-based seismic assessment methods using piping elbow test data

  • Jong-Min Lee ;Jae-Yoon Kim;Hyun-Seok Song ;Yun-Jae Kim ;Jin-Weon Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1616-1629
    • /
    • 2023
  • To quantify the conservatism of existing ASME strain-based evaluation methods for seismic loading, this paper presents very low cycle fatigue test data of elbows under various cyclic loading conditions and comparison of evaluation results with experimental failure cycles. For strain-based evaluation methods, the method presented in ASME BPVC CC N-900 and Sec. VIII are used. Predicted failure cycles are compared with experimental failure cycle to quantify the conservatism of evaluation methods. All methods give very conservative failure cycles. The CC N-900 method is the most conservative and prediction results are only ~0.5% of experimental data. For Sec. VIII method, the use of the option using code tensile properties gives ~3% of experimental data, and the use of the material-specific reduction of area can reduce conservatism but still gives ~15% of experimental data.

Automated Functionality Test Methods for Web-based Applications (웹 기반 어플리케이션의 기능 테스트 자동화 방법)

  • Kuk, Seung-Hak;Kim, Hyeon-Soo
    • The KIPS Transactions:PartD
    • /
    • v.14D no.5
    • /
    • pp.517-530
    • /
    • 2007
  • Recently web applications have growl rapidly and have become more and more complex. As web applications become more complex, there is a growing concern about their quality. But very little attentions are paid to web applications testing and there are scarce of the practical research efforts and tools. Thus, in this paper, we suggest the automated testing methods for web applications. For this, the methods generate an analysis model by analyzing the HTML codes and the source codes. Then test targets are identified and test cases are extracted from the analysis model. In addition, test drivers and test data are generated automatically, and then they are depleted on the web server to establish a testing environment. Through this process we can automate the testing processes for web applications, besides the automated methods makes our approach more effective than the existing research efforts.

A study on the slacks pattern making according to the Movement-Fitness (Part I) (동작 적합성에 따른 Slacks Pattern 설계에 관한 연구 (Part I))

  • 박영득
    • Journal of the Korean Home Economics Association
    • /
    • v.34 no.2
    • /
    • pp.43-55
    • /
    • 1996
  • The purpose of this study was to investigate the slacks pattern making on the movement-fitness of the knee region. The experimental items were divided into the lower limb movement (M1~M5) and slacks pattern designs (4 : basic pattern, in-pleats, side-pleats, seam-line increase). This study was done by clothing pressure test, sensory evaluation test and the difference shape-transformation of wearing-slacks. The summarized finding resulted from experiments and investigation are suggested as follows ; First, the clothing pressure test showed that the order of clothing pressure in the movement was the rabbit leap movement (M3), the sit on knees (M4), the nobleman sitting (M5), the sit on chair (M2) from the highest to the lowest. In the comparison of clothing pressure tested by blocks of lower-limb, center front knee region shows the highest of 300g/cm2. In it by constructional methods, the clothing pressure of in-pleats, side-pleats methods shows lower than basic pattern, hem-line increase methods. Also in comparison of the two methods, in-pleats method shows lower than side-pleats method. Second, by the sensory evaluation test based on the lower-limb movements and constructional methods of slacks, it was found that the functional factor score of the rabbit leap movement was also the waist, hip, knee region was the lowest in all blocks. And in the comparison of constructional methods, in-pleats method was the highest in all methods. Third, in consideration of the difference in the shape-transformation of wearing-slacks on the movement-fitness, pleats pattern design methods showed that the ratio of shape-transformation was lower than basic on seam-line increase methods. But the difference of the side-pleats and in-pleats methods was litle. According to these investigation, the slacks pattern making caused by movement-fitness on the knee region, in-pleats design method was the functional slacks pattern.

  • PDF

Fundamentals of Ecotoxicity Evaluation Methods Using Domestic Aquatic Organisms in Korea: (KII) Green Algae (국내 생물종을 이용한 생태독성평가 기반연구: (III) 녹조류)

  • An, Youn-Joo;Nam, Sun-Hwa;Baek, Yong-Wook
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.2
    • /
    • pp.117-127
    • /
    • 2008
  • Green algae are important primary producers in aquatic ecosystem, and they are sensitive test species in bioassay. Green algae are broadly used to assess the adverse effects of various chemicals by measuring the inhibition of metabolism, reproduction and survival. In this study, we extensively gathered domestic and foreign toxicity test methods conducted using green algae, which are distributed in Korean water environment. Selected eight domestic green algae were Chlamydomonas reinhardtii, Desmodesmus subspicatus (=Scenedesmus subspicatus), Scenedesmus abundans, Scenedesmus acutus, Scenedesmus quadricauda, Podohedriella falcata (=Ankistrodesmus falcatus), Pseudokirchneriella subcapitata (=Selenastrum capricornutum), and Chlorella vulgaris. Forty four test methods were collected from the standard test ones, government reports, SCI papers and Korean research papers. P. subcapitata and D. subspicatus are the most common test species recommended by the standard test methods. Initial cell density and dilution water were the main differences among the test methods we collected. We proposed the suitable ecotoxicity test methods based on domestic green algae in Korea. This study could be a fundamental basis to establish the ecotoxicity test methods by green algae distributed in Korea.

A Study on Requirements and Test Methods for the Safety of Electromyographs and Evoked Response Equipments (근전도계 및 유발성 응답기의 안전 요구사항 및 시험방법 연구)

  • Moon, I.H.;Nam, K.I.;Park, S.K.;Park, S.G.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.3 no.1
    • /
    • pp.41-47
    • /
    • 2009
  • This paper describes requirements and test methods for the safety of electromyographs and evoked response equipments to be used for medical examination of the central nerve system and motor-sensory functions in cortex. We first establish internationally harmonized requirements for the safety, and then propose a test procedure and test methods corresponding to the requirements based on the international standards. However requirements for the performance of each equipments are not specified in order to admit maker's specifications. Using a electromyography equipment we verified validity of the test methods proposed. Results of this study can be used as a standard for approval of Korea Food and Drug Administration (KFDA).

  • PDF