• Title/Summary/Keyword: test circuit

Search Result 1,833, Processing Time 0.037 seconds

Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364 (IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰)

  • Kim, Doo-Ung;Ryu, Kyu-Sang;Kim, Han-Soo;Shin, Dae-Sung;Ryu, Ki-Hwan;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.

The Study of Electromagnetic Force by Three Phase Short-Circuit Test of Cable (케이블 삼상단락 실증시험을 통한 전자력 영향 검토)

  • Hong, Dong-Suk;Kim, Hae-Jun;Park, Sung-Min;Chang, Woo-Suk;Park, Heong-Suk;Jang, Tae-In;Kang, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.395_396
    • /
    • 2009
  • This paper handles with effect of electromagnetic force on the cables by fault current accompanied by accident of underground transmission cable. Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, interaction of electromagnetic force from fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, etc. and close consideration is required for it. This paper describes the effect of electromagnetic force through results of three phase short-circuit test and electromagnetic force analysis using theoretical calculations and electrical evaluation test after three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

  • PDF

LabVIEW Based Laboratory Typed Test Setup for the Determination of Induction Motor Performance Characteristics

  • Calis, Hakan;Caki, Eyup
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1928-1934
    • /
    • 2014
  • Induction motors are widely used due to their rugged, robust and easy to care features. Since they are heavily used in industry, testing of three phase induction motors have play a vital role. In order to determine motor equivalent circuit parameters, efficiency of motor, squirrel caged laboratory sized an induction motor test setup is prepared. It is suitable for the induction motor with the frame size of 100 and 112. A virtual Instrumentation typed engineering workbench (called as LabVIEW) software packet, is utilized as a graphical user interface program. Motor input power is measured by measuring the input voltage, current and power factor with the help of hall effect typed voltage and current transformers. Also, the output power is measured by measuring the speed and torque with the help of an encoder and torque sensor. All outputs of the voltage and current transformer, encoder and temperature, torque sensors are given to the Data Acquisition Card (DAQ) which acquires the data for processing and then the equivalent circuit parameters, efficiency, performance and loading characteristics are found out, using LabVIEW based user interface. It is suggested to use this test rig for the quality control of produced motors in industry, and an educational experiment setup in the school laboratories.

Absolute Evaluation Method to Obtain Ratio Error and Phase Displacement of Current Transformers (전류변성기의 비오차와 위상오차의 절대 평가 기술)

  • Kim, Yoon-Hyoung;Jung, Jae-Kap;Han, Sang-Gil;Koo, Kyung-Wan;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.153-159
    • /
    • 2008
  • We have developed an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) without any precise standard CT by measuring four parameters in a CT equivalent circuit. The excitation admittance in the CT equivalent circuit can be obtained by employing standard resistors with negligible reactive component. The secondary leakage impedance in the CT equivalent circuit can be measured using a universal impedance bridge. The method was applied to CTs under test with the wide current ratios in the range of 5 A / 5 A - 5,000 A / 5 A and 5 A / 1 A - 5,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Canada using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

Improved Current Source using Full-Bridge Converter Type for Thyristor Valve Test of HVDC System (HVDC 시스템의 SCR 사이리스터 밸브 시험을 위한 Full-Bridge Converter 방식의 개선된 전류원 회로)

  • Jung, Jae-Hun;Cho, Han-Je;Goo, Beob-Jin;Nho, Eui-Cheol;Chung, Yong-Ho;Baek, Seung-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.363-368
    • /
    • 2015
  • This paper deals with an improved current source using full-bridge converter type for thyristor valve test of HVDC system. The conventional high-current and low-voltage source of synthetic test circuit requires additional auxiliary power supply to provide the reverse voltage for the auxiliary thyristor valve during turn-off process. The proposed circuit diagram to provide the reverse voltage is extremely simple because no additional component is required. The reverse voltage can be obtained from the input DC voltage of the high-current and low-voltage power supply. The operation principle and design method of the proposed system are described. Simulation and experimental results in scaled down STC of 200 V, 30 A demonstrate the validity of the proposed scheme.

BIST Architecture for Datapath Megacells (데이터 패스 메가셀을 위한 BIST 구조)

  • 김형주;손일헌
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1117-1120
    • /
    • 1998
  • BIST architecture and circuit design are presented for the self-test of various datapath megacells including embedded SRAM, barrel shifter, adder and multiplier. The BIST architecture is composed of VCO, ROM, comparator and otehr control logic to measure the megacell' performance up to 300MHz. PC interface and control logic are also implemented to perform the manual testing of each megacell with various test patterns. The control logic was designed using VHDL and its circuit is synthesized using Synopsys for $0.6\mu$ 1-poly, 3-matal CMOS technology.

  • PDF

The PLD Circuit Design of Pattern Generator for the Logical Inspection of Logical Defection (논리결함 검사를 위한 Pattern Generator의 PLD 회로 설계)

  • 김준식;노영동
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.4
    • /
    • pp.1-7
    • /
    • 2003
  • In this paper, we design the pattern generator circuits using PLDs(Programmable Logic Devices). The pattern generator is the circuit which generates the test pattern signal for the inspection of logical defects of semiconductor products. The proposed circuits are designed by the PLD design tool(MAX+ II of ALTERA). Also the designed circuits are simulated for the verification of the designed ones. The simulation results have a good performance.

  • PDF

Experiment on DC Circuit Breaker for Inductive Load by Improved Magnetic Arc-extinguisher and Arc-Attenuation Circuit (개선된 자기소호회로와 아크전압 억제회로를 사용한 유도성 부하의 직류차단 특성 실험)

  • Lee, Sung-Min;Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.495-499
    • /
    • 2012
  • Recently, DC distribution systems become hot issues since DC type loads increase rapidly according to the expansion of IT equipment such as computers, servers, and digital devices; DC type loads will cover 50% for all electricity loads in 2020 which was mere 10% in 2000. DC distribution systems are also accelerated by the expansion of renewable power systems since they are easy to be interfaced with DC grids rather than AC grids. However, removing the fault current in DC grids is comparably difficult since the current in DC grids has non zero-crossing point like in AC grids. Thus, developing dedicated DC circuit breakers for DC grids is necessary to get safety for human and electrical facilities. Magnet arc extinguishing method is proper to small size DC circuit breakers. However, simple Magnet arc extinguishing method is not enough to break inductive fault currents. This paper proposed a novel DC circuit breaker against inductive fault current defined by IEEE C37.14-2004 Standard for Low-Voltage DC Power Circuit Breakers Used in Enclosures. The performance of the proposed DC circuit breaker was verified by an experimental circuit breaker test system built in this research.

Study on Improvement of Circuit Repairing Abilities through Headlight Assignment on Automotive Electronics Subject (자동차전기 과목의 '전조등 과제' 에서 회로수리능력 향상에 관한 연구)

  • Yu, Jeong-Hyo;Lee, Yong-Jin
    • 대한공업교육학회지
    • /
    • v.38 no.1
    • /
    • pp.239-258
    • /
    • 2013
  • The purpose of this study is to define what circuit repairing ability is and to check improvement in learner's circuit repairing abilities by verifying conformity of learner's achievement of target goals that have been derived from headlight assignment based on circuit repairing ability that has been categorized into six sub-factors, which are preparing ability, attaching/detaching ability, circuit analyzing ability, inspecting and measuring ability, repairing (problem solving) ability and organizing ability. In order to achieve the purpose of study, degree of improvement in circuit repairing ability of learner's group was measured through experiment design and verification by group of experts. SPSS statistics program was used for statistical analysis in which average value for descriptive statistics, Cronbach ${\alpha}$ coefficient and t-test were conducted. Level of significance for t-test was p<.05. The conclusions from conducting this study are as follows. Firstly, the usage of terminology 'circuit repairing ability' pertaining to ability to repair failure of electrical devices in automobiles was confirmed to be appropriate. Secondly, the categorization of circuit repairing ability into sub-factors of preparing ability, attaching/detaching ability, circuit analyzing ability, inspecting and measuring ability, repairing (problem solving) ability and organizing ability was confirmed to be appropriate. Thirdly, field instruction on headlight assignment that has been revised according to achievement of learner's goals was confirmed to be effective in improving learner's circuit repairing abilities compared to regular training. Fourthly, field instruction on headlight assignment that has been revised according to achievement of learner's goals was confirmed to be effective in improving sub-factors of circuit repairing abilities, which are preparing ability, attaching/detaching ability, circuit analyzing ability, inspecting and measuring ability, repairing (problem solving) ability and organizing ability.

A Study on the Parameters and Characteristic of Induction Motor driven by Inverter (인버터로 구동되는 유도전동기의 정수 및 특성에 관한 연구)

  • 전내석;김종윤;오진석;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.497-504
    • /
    • 2000
  • This paper presents a method for the equivalent-circuit parameters and torque characteristics calculation of squirrel-cage induction motors. The measurment of motor parameters were calculated by the stator resistance test, the blocked rotor test and no load test through T type equivalent-circuit method. Especially, this paper describes the test results obtained by using hall sensor and strain gage for the current and the torque characteristics of induction motors. 1(HP), three-phase squirrel cage induction motor has been used during the test and the parameters are compared with those obtained by the maker parameters of simulation results and experiment.

  • PDF