• Title/Summary/Keyword: test circuit

Search Result 1,839, Processing Time 0.031 seconds

A Study on Improvement of Test & Evaluation of Vehicle Part in Mixed Equipment and Defense Industrial Technology (혼성장비 차량부 시험평가 및 방위산업기술 보호 제도 개선에 관한 연구)

  • Yoon, Heung-Soo;Ryu, Yeon-Seung
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.241-249
    • /
    • 2018
  • The military purpose vehicles are developed by using the platform of civil vehicles according to the commercial vehicle expansion plan and military supplied product commercialization policy. But the information related to the military purpose vehicle which adopts the same platform with the civil vehicle is forced to be exposed because its information is revealed by containing into the maintenance manual and electric circuit diagram. Especially, the information disclosure should be blocked by reviewing the application of technology protection because the military vehicle becomes combating purposed mixed equipment when the missile and radar are mounted. The mixed equipment means the one configured with more than 2 types of equipment, and it is categorized into the main and sub equipment. This study was performed to derive the problems in Korean system for vehicle part test evaluation on the mixed equipment and the defense industry technology protection system, and to derive the methods for improving through interviews with the specialists. The conflicts between the civil laws and army regulation were reduced by adding a clause that the engine reflected with the newest emission gas standard should be mounted based on the time of force integration, and the commercialized military supplies were designated as element technology of defense industry technology in consideration of its roles and functions.

A Study of the Apply Proximity Sensor for Improved Reliability Axle Detection (열차 차축검지 신뢰성 향상을 위한 근접센서 방식 Axle Counter 적용 연구)

  • Park, Jae-Young;Choi, Jin-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5534-5540
    • /
    • 2015
  • This In the railway signaling system, applications of axle counter in addition to track circuit goes on increasing for detecting train position. Consequently, this paper compares sensor methods of axle counter with between geo-magnetism method and proximity sensor method. And it presents differences and results, to improve reliabilities of train detection and axle counting. Also, this article presents an applied result which is based on field experience, with regard to installation, considering attachment condition of sensor part for accurate axle counting. This study acquires expandability that is able to perform not only axle counting function but also various other functions (direction detection of train, speed detection of train, and so on). It was a result of a change of design in order to judge phase difference of sensors, to improve reliability of axle counting. Furthermore, it does not subordinate to characteristics (type, weight of train). And it is confirmed that the omission of axle counting was not occurred in 350km/h. This was the result of Lab test after the construction of transfer equipment of trial axle and Test Bed for axle counting. Both of them are self-productions. Through this, it prepares foundation which is able to apply not only to train detection but also to speed of passing trains, formation number of trains, detector locking condition - when the train passes the section of switch point, and level crossing devices. Furthermore, it would be judged to contribute safety train operation if proximity sensor method applies to the whole railway signaling system from now on.

Feasibility Study of Improved Train Control System Using On-board Controller for Intelligent Control of Trackside Facilities (선로변 시설물의 지능적 제어를 위한 차상중심 열차제어시스템 시뮬레이션 기반 성능 평가)

  • Baek, Jong-Hyen;Jo, Hyun-Jeong;Chae, Eun-Kyung;Choi, Hyun-Young;Kim, Yong-Gyu
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.6
    • /
    • pp.528-533
    • /
    • 2013
  • To improve the efficiency and safety of railway systems, the train control system has considerably evolved from the ground-equipment-based control system (e.g. track circuit, interlocking system, etc.) into the on-board-equipment-based control system. In addition, this train control system enables the rolling stock to intelligently control the trackside facilities by introducing information and communication technologies (ICT). Accordingly, since the ICT-based train control system simplifies the railway system (i.e. the heavy ground-equipment can be removed), an efficient and cost-effective railway system can be realized. In this paper, we perform a feasibility test of the ICT-based train control system using a simulation. To this end, we implement a test-bed consisting of prototype machines of on-board/ground equipment and introduce an integrated operation scenario for the train control. The simulation results satisfy all the requirements of train operation according to the scenario and show the effectiveness of the proposed train control system.

A Study of a Virtual Reality Interface of Person Search in Multimedia Database for the US Defense Industry (미국 방위산업체 상황실의 인물검색 활동을 돕는 가상현실 공간 인터페이스 환경에 관한 연구)

  • Kim, Na-Young;Lee, Chong-Ho
    • Journal of Korea Game Society
    • /
    • v.11 no.5
    • /
    • pp.67-78
    • /
    • 2011
  • This paper introduces an efficient and satisfactory search interface that enables users to browse and find the video data they want from a massively huge video database widely used in various multimedia environment. The target user group is information analysts at US defense industry or governmental intelligence agencies whose job is to identify a certain person from a lot of video footage taken from CCTV(Closed-circuit Television) cameras. For the first user test, we suggested the CAVE-like virtual reality interface to be the most optimal for the tasks we designed for, so we compared this interface with desktop interface. The softwares and database developed and optimized for each task were used in this user test. For the second user test, we researched on what input devices would be most optimal for enhancing efficiency of search task in the CAVE-like virtual reality system. Especially we focused our effort on measuring the effectiveness and user satisfaction of three different types of devices that embody gestural interface input system that encourages users' ergonomic control of the interface. We also measured the time consumed for performing each task to find out the most efficient input device among the ones tested.

Design of 256Kb EEPROM IP Aimed at Battery Applications (배터리 응용을 위한 1.5V 단일전원 256Kb EEPROM IP 설계)

  • Kim, Young-Hee;Jin, RiJun;Ha, Pan-Bong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.558-569
    • /
    • 2017
  • In this paper, a 256Kb EEPROM IP aimed at battery applications using a single supply of 1.5V which is embedded into an MCU is designed. In the conventional cross-coupled VPP (boosted voltage) charge pump using a body-potential biasing circuit, cross-coupled PMOS devices of 5V in it can be broken by the junction or gate oxide breakdown due to a high voltage of 8.53V applied to them in exiting the program or erase mode. Since each pumping node is precharged to the input voltage of the pumping stage at the same time that the output node is precharged to VDD in the cross-coupled charge pump, a high voltage of above 5.5V is prevented from being applied to them and thus the breakdown does not occur. Also, all erase, even program, odd program, and all program modes are supported to reduce the times of erasing and programming 256 kilo bits of cells. Furthermore, disturbance test time is also reduced since disturbance is applied to all the 256 kilo bits of EEPROM cells at once in the cell disturb test modes to reduce the cell disturbance testing time. Lastly, a CG driver with a short disable time to meet the cycle time of 40ns in the erase-verify-read mode is newly proposed.

A Study on the selection and noise test of elelctronic sensor for Vacuum Circuit Breaker (진공차단기용 전자식 센서의 선정 및 노이즈 시험에 관한 연구)

  • Lee, Ki Seon;Park, Jung Cheul;Chu, Soon Nam
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2503-2508
    • /
    • 2014
  • This study is about the selection and noise test of electronic sensor which is preceded by electric Operating Cell(EOC) development using electronic sensor technology to solve the structural weakness of Mechanism Operated Cell(MOC) in VCB, and has a final target in product development minimizing contact malfunction of the chattering or rebounce states caused by existing MOC. In this test results, when opening and closing VCB, rising velocity of surge voltage in opening time was measured 4.2 times faster than closing time and noise decibel value was measured respectively 120dB and 110dB. When supplying 60kV power frequency overvoltage, we found that sensor output graph in VCB opening and closing times operated stably without distortion. When supplying 150kV $1.2{\times}50{\mu}s$ impulse frequency voltage, we found that voltage graph of output contact in sensor opening and closing sides maintained a normal condition without distortion, and when supplying 2500A current, we found that tested result of electric field noise operated stably without distortion.

Reducing the Test Time for Chemical/Mechanical Durability of Polymer Electrolyte Membrane Fuel Cells (고분자연료전지의 화학적/기계적 내구성 평가 시간 단축)

  • Sohyeong Oh;Donggeun Yoo;Kim Myeonghwan;Park Jiyong;Choi Yeongjin;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.517-522
    • /
    • 2023
  • A chemical/mechanical durability test of polymer membrane evaluation method is used in which air and hydrogen are supplied to the proton exchange membrane fuel cell (PEMFC) and wet/dry is repeated in the open circuit voltage (OCV) state. In this protocol, when wet/dry is repeated, voltage increase/decrease is repeated, resulting in electrode degradation. When the membrane durability is excellent, the number of voltage changes increases and the evaluation is terminated due to electrode degradation, which may cause a problem that the original purpose of membrane durability evaluation cannot be performed. In this study, the same protocol as the department of energy (DOE) was used, but oxygen was used instead of air as the cathode gas, and the wet/dry time and flow rate were also increased to increase the chemical/mechanical degradation rate of the membrane, thereby shortening the durability evaluation time of the membrane to improve these problems. The durability test of the Nafion 211 membrane electrode assembly (MEA) was completed after 2,300 cycles by increasing the acceleration by 2.6 times using oxygen instead of air. This protocol also accelerated degradation of the membrane and accelerated degradation of the electrode catalyst, which also had the advantage of simultaneously evaluating the durability of the membrane and the electrode.

Correlations of Cerebellar Function with Psychotic Symptoms and Cognitive Function in Schizophrenic Patients (남자 정신분열병 환자의 소뇌기능과 정신증상 및 인지기능간의 연관성)

  • Kim, Seo Young;Jun, Yong Ho;Kwon, Young Joon;Jeong, Hee Yeon;Hwang, Bo Young;Shim, Se Hoon
    • Korean Journal of Biological Psychiatry
    • /
    • v.14 no.3
    • /
    • pp.184-193
    • /
    • 2007
  • Objectives:There is increasing evidence that the cerebellum plays an important role in cognition and psychiatric symptoms as well as motor coordination. The concept of cognitive dysmetria has been making cerebellar function in schizophrenia the focus of current studies. In other words, disruption in the corticocerebellum-thalamic -cortical circuit could lead to disordered cognition and clinical symptoms of schizophrenia. The purposes of this study were to determine cerebellar dysfunction in male schizophrenic patients semiquantitatively with ICARS and to investigate the clinical and cognitive correlates of ICARS in patients. Methods:We compared the scores of cerebellar neurologic sign using ICARS in 47 male patients with a DSM-IV-TR diagnosis of schizophrenia with 30 gender and age-matched healthy control subjects. The semiquantitative 100-point ICARS consists of 19 items divided into 4 unequally weighted subscores:posture and gait disturbances, kinetic functions, speech disorders and oculomotor disorders. All subjects were also assessed with cognitive function test. Cognitive functions were evaluated by Korean-Mini Mental Status Examination (K-MMSE), Verbal fluency test, and Clock drawing test. The patients were administered Korea version of Positive and Negative Symptom Scale(K-PANSS) to assess the symptom severity. Results:Schizophrenic patients had significantly higher scores on the ICARS than control subjects with posture and gait disturbances, kinetic functions, and oculomotor disorders. They also showed more significant impairments in cognitive function tests than control subjects. There was a significant correlation between ICARS and negative symptoms of patients. In cognitive function test, Clock drawing test was significantly associated with negative symptoms. In addition, Clock drawing test was negatively correlated with the total score of ICARS. Conclusion:In this study, we confirmed that schizophrenic patients have significant impairments in cognitive and cerebellar function, and that those were related with negative symptoms of schizophrenic patients. These results support a role of the cerebellum in schizophrenia. It is meaningful that we used a structured, and reliable procedure for rating neurological soft signs, ICARS. We hope that future prospective studies using a similar design help that rate of neurological sign should have been visible with the progression of illness.

  • PDF

Relation Between Degree of Consistency of Elementary Students' Preconceptions on the Brightness of Electric Bulb and Their Cognitive Conflict (전구의 밝기에 대한 초등학생들의 사전개념 일관성 정도와 인지갈등 정도와의 관계)

  • Jung Mee-young;Kim Kung-suk;Kwon Jaesoo
    • Journal of Korean Elementary Science Education
    • /
    • v.24 no.3
    • /
    • pp.259-267
    • /
    • 2005
  • This study was to investigate the elementary students' preconception on the brightness of electric bulb and degree of consistency on their preconceptions. Participants were 160 students of fifth graders in Seoul area. They had already teamed about the brightness of series circuit and parallel circuit of batteries. After they solved six problems in the same context, we provided them a pair of circuit which was an anomalous situation. And then they conducted CCLT (Cognitive Conflict Level Test). Elementary school students showed various preconceptions when they explained the light of bulb of two Simple electric Circuits. Many Students Consistently Showed the Scientific misconceptions like 'the light of bulb of two simple electric circuits was that the more batteries and the fewer bulbs were brighter.' The level of consistency that students presented scientific misconceptions was grouped all of four, such as 'high, middle, low, and nothing.' Therefore the higher scientific achievement they have, the higher consistency they have. As the students had high consistency level, they revealed high cognitive conflict level significantly. This high consistency will help them to change their preconception on the brightness of electric bulb and their cognitive conflict.

  • PDF

Compact and Wideband Coupled-Line 3-dB Ring Hybrids (Coupled Line으로 구성된 작고 넓은 대역폭을 가지는 3-dB Ring Hybrids)

  • Ahn, Hee-Ran;Kim, Jung-Joon;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.862-877
    • /
    • 2008
  • In this paper, two types of wideband 3-dB ring hybrids are compared and discussed to show the ring hybrid with a set of coupled-line sections better. However, the better one still has a realization problem that perfect matching can be achieved only with -3 dB coupling power. To solve the problem, a set of coupled-line sections with two shorts is synthesized using one- and two-port equivalent circuits and design equations are derived to have perfect matching, regardless of the coupling power. Based on the design equations, a modified ${\Pi}-type$ of transmission-line equivalent circuit is newly suggested. It consists of coupled-line sections with two shorts and two open stubs and can be used to reduce a transmission-line section, especially when its electrical length is greater than ${\pi}$. Therefore, the $3\;{\lambda}/4$ transmission-line section of a conventional ring hybrid can be reduced to less than ${\pi}/2$. To verify the modified ${\Pi}-type$ of transmission- line equivalent circuit, two kinds of simulations are carried out; one is fixing the electrical length of the coupled-line sections and the other fixing its coupling coefficient. The simulation results show that the bandwidths of resulting small transmission lines are strongly dependent on the coupling power. Using modified and conventional ${\Pi}-types$ of transmission-line equivalent circuits, a small ring hybrid is built and named a compact wideband coupled-line ring hybrid, due to the fact that a set of coupled-line sections is included. One of compact ring hybrids is compared with a conventional ring hybrid and the compared results demonstrate that the bandwidth of a proposed compact ring hybrid is much wider, in spite of being more than three times smaller in size. To test the compact ring hybrids, a microstrip compact ring hybrid, whose total transmission-line length is $220^{\circ}$, is fabricated and measured. The measured power divisions($S_{21}$, $S_{41}$, $S_{23}$ and $S_{43}$) are -2.78 dB, -3.34 dB, -2.8 dB and -3.2 dB, respectively at a design center frequency of 2 GHz, matching and isolation less than -20 dB in more than 20 % fractional bandwidth.