• Title/Summary/Keyword: temporary crown

Search Result 59, Processing Time 0.035 seconds

THE MARGINAL ACCURACY OF TEMPORARY CROWN WITH DIFFERENT MATRIX (MATRIX에 따른 임시치관의 변연적합도에 관한 연구)

  • Ju, Tae-Hun;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.59-66
    • /
    • 1991
  • This study was designed to investigate the marginal accuracy of resin temporary crown with different matrix in indirect technique. Matrices were made from irreversible hydrocolloid impression material, putty type of vinyl polysiloxane silicone rubber and vacuum formed plastic sheet. The marginal discrepancies of the temporary crowns were measured using a measuring microscope. The obtained results were as follows 1. The marginal accuracy temporary crown using vinyl polysiloxane silicone rubber or vacuum formed plastic form was better than that of the temporary crown using irreversible hydrocolloid impression material. 2. The marginal accuracies of the temporary crown using the irreversible hydrocolloid impression material and putty type of the vinyl polysiloxane silicone rubber obtained the best results at the distal measuring point. 3. The vacuum formed plastic form was recorded a more acceptable marginal accuracy at the distal and mesial measuring points.

  • PDF

원내에서 5축 밀링기로 가공한 PMMA temporary crown의 다양한 임상적 활용

  • Suh, Sangjin
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.26 no.2
    • /
    • pp.68-83
    • /
    • 2017
  • With the increasing popularity of dental CAD / CAM, the kinds of materials that can be used and the range that can be utilized are also increasing. One of the biggest advantages of a dental CADCAM is that you can make a final prosthesis with one visit, but in case of zirconia or a complex aesthetic prosthesis, it is often difficult to make it in one day. In this case, temporary PMMA material can be used to provide a temporary crown with aesthetic and functional properties to the patient and can be used as a test crown or template for the final prosthesis. And if you are with a 5-axis milling machine in a clinic, you can make a temporary crown precisely to a large extent in a short time. In this article, various applications and clinical cases of PMMA temporary crown in the clinic will be presented.

Comparison of three-dimensional adaptation as per the rinsing time of temporary crown manufactured using a digital light processing printer (디지털 광 조명 방식으로 제작한 임시 크라운의 세척 시간에 따른 3차원 적합도 평가)

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.334-340
    • /
    • 2020
  • Purpose: This study aimed to compare three-dimensional adaptation with the rinsing time of the temporary crown produced using the digital light processing method. Methods: The maxillary right first molar abutment was scanned with a dental scanner. A temporary crown was designed with the scanned abutment. The designed crown was made of 10 temporary crowns using a digital light processing printer. The crowns were divided into the 5-minute and 10-minute rinsing groups; 5 temporary crown washes were performed for each group. In order to obtain the internal data, each group was scanned for a temporary crown. The three-dimensional fit was measured by superimposing the scanned internal surface data and the abutment data. The average comparison of three-dimensional adaptation was analyzed using the Mann-Whitney U test. Results: The 5-minute rinsing group showed a significantly higher adaptation of 71.42±3.08 ㎛ as compared to the 10-minute rinsing group (67.52±0.92 ㎛) (p<0.05). Conclusion: When making a temporary crown with a digital light processing method, a rinsing time of 10 minutes is appropriate.

Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength

  • Ha, Seung-Ryong;Yang, Jae-Ho;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.14-17
    • /
    • 2010
  • PURPOSE. The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time. MATERIAL AND METHODS. One monomethacrylate-based temporary crown and FPD material (Trim) and three dimethacrylate-based ones (Protemp 3 Garant, Temphase, Luxtemp) were investigated. 20 specimens (${\phi}\;4\;mm\;{\times}\;6\;mm$) were fabricated and randomly divided into two groups (Group I: Immediately, Group II: 1 hour) according to the measurement time after completion of mixing. Universal Testing Machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed using one-way ANOVA, the multiple comparison Scheff$\acute{e}$ test and independent sample t test ($\alpha\;=\;0.05$). RESULTS. Trim showed severe permanent deformation without an obvious fracture during loading at both times. There were statistically significant differences among the dimethacrylate-based materials. The dimethacrylate-based materials presented an increase in strength from 5 minutes to 1 hour and were as follows: Protemp 3 Garant (23.16 - 37.6 MPa), Temphase (22.27 - 28.08 MPa), Luxatemp (14.46 - 20.59 MPa). Protemp 3 Garant showed the highest value. CONCLUSION. The dimethacrylate-based temporary materials tested were stronger in diametral tensile strength than the monomethacrylate-based one. The diametral tensile strength of the materials investigated increased with time.

Evaluation of Color Stability according to Shade of Temporary Crown Resin Using Digital Spectrophotometer: In Vitro Study

  • Ku, Hye-min;Jun, Mi-Kyoung
    • Journal of dental hygiene science
    • /
    • v.22 no.3
    • /
    • pp.139-147
    • /
    • 2022
  • Background: Temporary crown resins are used prior to prosthesis placement, indicating the importance of aesthetics. The aim of this study was evaluate the color stability of various staining solutions according to the color of temporary crown resins using VITA Easyshade V. Methods: The temporary crowns used were the powder-liquid type and included four shades. A total of 36 specimens were fabricated in the form of disks with a diameter of 1.8 mm and a depth of 2 mm. They were divided into four groups of nine each, and staining was performed for seven days by precipitation in 3 mL of three staining solutions composed of distilled water, black coffee, and red wine. Color and color stability evaluations were performed by a trained examiner using a digital spectrophotometer (VITA Easyshade V). Color stability was analyzed using the ΔE value. Results: Because of the color stability evaluation using the ΔE value, the difference between three and seven days was significant in the specimen I and III groups (p<0.05). Further, post hoc analysis showed that the ΔE value of red wine was significant, indicating that the color stability in red wine was low. The ΔE values in group II between days three and seven were statistically significant (p<0.05). Post hoc analysis showed that distilled water, coffee, and wine had the highest ΔE values on day three. On day seven, the ΔE value for wine was significant, and the color stability was low. There was no significant difference in group IV according to the staining period and staining solution; therefore, color stability was high (p>0.05). Conclusion: This study showed that most temporary resin restorations exhibited color stability in the staining solution. The darker the color of the temporary resin restoration, the higher the color stability against extrinsic staining.

A Study on improvements in manufatured technique of all Ceramic Crown (전부도재관 기법 개선에 관한 연구)

  • Shin, Moo-Hak;Kim, Yeon-Soo;Choi, Un-Jea;Chung, Hee-Sun
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.9-15
    • /
    • 2002
  • A new kind of 'All Ceramic Crown' could be manufactured by making improvements in the manufacturing technique for the current 'All Ceramic Crown' which does not use a special ceramic but rather a general one as a substitute. If we use the manufacturing technique for the 'All Ceramic Crown', metal coping and core are not produced. The effects of the new manufacturing technique for the 'All Ceramic Crown' are as follows: First. We do not need to use new material or special machinery or tools. Second. We can use general machinery and tools. Third. Using the basic 'All Ceramic Technique', we anticipate improvement in learning in our students. Forth. We can save effort, materials and time. Fifth. The technique also has advantages for esthetic 'temporary crown'.

  • PDF

Crown Ratio Models for Tectona grandis (Linn. f) Stands in Osho Forest Reserve, Oyo State, Nigeria

  • Popoola, F.S.;Adesoye, P.O.
    • Journal of Forest and Environmental Science
    • /
    • v.28 no.2
    • /
    • pp.63-67
    • /
    • 2012
  • Crown ratio is the ratio of live crown length to tree height. It is often used as an important predictor variable for tree growth equation. It indicates tree vigor and is a useful parameter in forest health assessment. The objective of the study was to develop crown ratio prediction models for Tectona grandis. Based on the data set from the temporary sample plots, several non linear equations including logistics, Chapman Richard and exponential functions were tested. These functions were evaluated in terms of coefficient of determination ($R^2$) and standard error of the estimate (SEE). The significance of the estimated parameters was also verified. Plot of residuals against estimated crown ratios were observed. Although the logistic model had the highest $R^2$ and the least SEE, Chapman-Richard and Exponential functions were observed to be more consistent in their predictive ability; and were therefore recommended for predicting crown ratio in the stand.

The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment (변형된 임플란트 임시 지대주의 물성에 대한 연구)

  • Yang, Byung-Duk;Yoon, Tae-Ho;Choi, Un-Jae;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

Anterior implant case report using digital guided implant template (임플란트 가이드를 활용한 전치부 수복증례)

  • Kim, Taeeun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.41-50
    • /
    • 2018
  • Guided implant surgery is useful in anterior implant case in terms of fixture installation and temporary crown delivery. For the aesthetic prosthetics in anterior implant, the position of the implant fixture is crucial. Guided surgery is the top-down procedure and we designed prosthetics first and then determine the position of the fixture. Guided surgery can reduce the stress of dentist with difficult anterior implant case.