• Title/Summary/Keyword: template assisted

Search Result 40, Processing Time 0.02 seconds

Controlled Synthesis of Spherical Polystyrene Beads and Their Template-Assisted Manual Assembly

  • Yoon, Seo Young;Park, Yi-Seul;Lee, Jin Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2281-2284
    • /
    • 2014
  • Polystyrene beads (PS beads) with narrow size distribution were synthesized, and their diameter was controlled from 1.2 to $5{\mu}m$ by varying the injection rate of a styrene solution containing initiator and the concentration of reactant, such as initiator and capping material. The diameter of the PS beads increased with increasing in the injection rates and the initiator concentration or decreasing the capping material concentration. Then, we used the PS beads as building block, and organized them into a hexagonally close-packed monolayer on substrate with template-assisted manual assembly. We showed perfect hexagonally close-packed organization of the PS beads with various sizes in large-scale area. And we demonstrated the superiority of the dry manual assembly over the wet self-assembly in terms of simplicity, speed, perfect ordering, and large scale.

Implant Fixture Installation in the Posterior Maxilla Using a Tooth-supported Surgical Template Based on Computer Assisted Treatment Planning (컴퓨터 보조 기반 치아 지지 서지컬 템프레이트를 이용한 상악구치부 임플란트 식립)

  • Kim, Soung Min;Kim, Myung Joo;Lee, Jee Ho;Myoung, Hoon;Lee, Jong Ho;Kim, Myung Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.6
    • /
    • pp.381-389
    • /
    • 2013
  • Two patients with partial edentulous maxilla were scheduled to undergo installation of implant fixtures using a tooth-supported surgical template based on computer assisted treatment planning. After 3-dimensional (3D) computed tomographic scanning was transferred to the OnDemand3D (Cybermed Co., Seoul, Korea) software program for virtual planning, fixtures of MK III Groovy RP implant of the Br${\aa}$nemark System (Nobel Biocare AB Co., G$\ddot{o}$teborg, Sweden) was installed using the In2Guide (CyberMed Co., Seoul, Korea) tooth-supported surgical template with a Quick Guide Kit (Osstem Implant Co., Seoul, Korea) system in the posterior maxilla of each patient. Sinus floor elevation with a xenogenic bone graft procedure was also performed simultaneously in one patient. Fixture installations were completed successfully without complications, such as sinus mucosa perforation, bony bleedings, fenestrations, or others. During the last two-year follow-up period after prosthetics delivery, each implant was found to be fine with no other minor complications. The entire procedures are reported and the literatures on use of tooth-supported surgical template was reviewed.

An assessment of template-guided implant surgery in terms of accuracy and related factors

  • Lee, Jee-Ho;Park, Ji-Man;Kim, Soung-Min;Kim, Myung-Joo;Lee, Jong-Ho;Kim, Myung-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.440-447
    • /
    • 2013
  • PURPOSE. Template-guided implant therapy has developed hand-in-hand with computed tomography (CT) to improve the accuracy of implant surgery and future prosthodontic treatment. In our present study, the accuracy and causative factors for computer-assisted implant surgery were assessed to further validate the stable clinical application of this technique. MATERIALS AND METHODS. A total of 102 implants in 48 patients were included in this study. Implant surgery was performed with a stereolithographic template. Pre- and post-operative CTs were used to compare the planned and placed implants. Accuracy and related factors were statistically analyzed with the Spearman correlation method and the linear mixed model. Differences were considered to be statistically significant at $P{\leq}.05$. RESULTS. The mean errors of computer-assisted implant surgery were 1.09 mm at the coronal center, 1.56 mm at the apical center, and the axis deviation was $3.80^{\circ}$. The coronal and apical errors of the implants were found to be strongly correlated. The errors developed at the coronal center were magnified at the apical center by the fixture length. The case of anterior edentulous area and longer fixtures affected the accuracy of the implant template. CONCLUSION. The control of errors at the coronal center and stabilization of the anterior part of the template are needed for safe implant surgery and future prosthodontic treatment.

Photoelectrochemical characterization of surface-modified CuInS2 nanorod arrays prepared via template-assisted growth and transfer

  • Yang, Wooseok;Kim, Jimin;Oh, Yunjung;Moon, Jooho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.401-401
    • /
    • 2016
  • Although vertically aligned one-dimensional (1D) structure has been considered as efficient forms for photoelectrode, development of efficient 1D nanostructured photocathode are still required. In this sense, we recently demonstrated a simple fabrication route for CuInS2 (CIS) nanorod arrays from aqueous solution by template-assisted growth-and-transfer method and their feasibility as a photoelectrode for water splitting. In this study, we further evaluated the photoelectrochemical properties surface-modified CIS nanorod arrays. Surface modification with CdS and ZnS was performed by successive ion layer adsorption and reaction (SILAR) method, which is well known as suitable technique for conformal coating throughout nanoporous structure. With surface modification of CdS and ZnS, both photoelectrochemical performance and stability of CuInS2 nanorod arrays were improved by shifting of the flat-band potential, which was analyzed both onset potential and Mott-schottky plot.

  • PDF

On Optical Power Distribution of Grating-Assisted Couplers with Three-Guides

  • Ho, Kwang-Chun;Kim, Yung-Kwon
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.945-948
    • /
    • 2000
  • The coupling properties of supermodes guided by grating-assisted directional couplers (GADCs) can be phrased in rigorous modal theory. Such a modal solution for TE modes expressed by simple electrical transmission-line networks is utilized to analyze the power distribution of GADCS with three guiding channels. In particular, the modal transmission-line theory can serve as a template for computational algorithms that systematically evaluate the coupling efficiency that are not readily obtained by other methods.

  • PDF

Low temperature deposition of LaMnO3 on IBAD-MgO template assisted by plasma (IBAD-MgO 기판상에 플라즈마를 이용한 LaMnO3 저온 증착)

  • Kim, H.S.;Oh, S.S.;Ha, D.W.;Ha, H.S.;Ko, R.K.;Moon, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.1-3
    • /
    • 2012
  • LMO($LaMnO_3$) buffer layer of superconducting coated conductor was deposited on IBAD-MgO template in the plasma atmosphere at $650^{\circ}C$ which is relatively low compared with conventional deposition temperature of more than $800^{\circ}C$. Deposition method of LMO was DC sputtering, and target and deposition chamber were connected to the cathode and anode respectively. When DC voltage was applied between target and chamber, plasma was formed on the surface of target. The tape substrate was located with the distance of 10 cm between target and tape substrate. When anode bias was connected to the tape substrate, electrons were attracted from plasma in target surface to the tape substrate, and only tape substrate was heated by electron bombardment without heating any other zone. The effect of electron bombardment on the surface of substrate was investigated by increasing bias voltage to the substrate. We found out that the sample of electron bombardment had the effect of surface heating and had good texturing at low controlling temperature.

Synthesis of Nanoporous Carbon as a Gas Adsorbent by Reverse Replication Process of Silica Template

  • Cho, Churl-Hee;Kim, Joon-Soo;Kim, Hong-Soo;Ahn, Young-Soo;Han, Moon-Hee;Yoo, Jong-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.519-524
    • /
    • 2003
  • Porous carbon with high surface area and pore volume was prepared by a reverse replication process and its toluene equilibrium adsorption behavior was investigated. The preparation process of the porous carbon was composed of fellowing sub-processes in series: synthesis and template preparation of silica gel, impregnation and polymerization of DVB monomer in silica template, carbonization of DVB polymer in a silica-polymer composite, and HF-assisted selective etching of silica in carbon-silica composite. The prepared porous carbon was nano porous and had ultrahigh specific surface area (2007 ㎡/g) and large pore volume (3.07 ㎤/g). The nanoporous carbon showed rapid toluene adsorption rate and good toluene adsorption capacity, compared with a commercial Y-type zeolite. In the present study, a reverse replication process to prepare nanoporous carbons will be introduced and its application potential as a gas adsorbent will be discussed.

Fabrication of IBAD-MgO template by continuous reel-to-reel process (연속 reel-to-reel 공정을 이용한 IBAD-MgO template 제조)

  • Ko, K.P.;Ha, H.S.;Kim, H.K.;Yu, K.K.;Ko, R.K.;Moon, S.H.;Oh, S.S.;Yoo, S.I.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.18-21
    • /
    • 2007
  • Highly textured MgO template by ion-beam-assisted deposition(IBAD) was successfully fabricated using a continuous reel-to-reel(R2R) mode. To enlarge the deposition area, the previous IBAD system was modified into the system with 14-pass and five heating zone. Every processing step was carried out using this multi-turn IBAD system. The overall process consists of R2R electropolishing of a hastelloy C276 tape, deposition of $Al_2O_3$ diffusion barrier, $Y_2O_3$ seed layer, IBAD-MgO and homoepi-MgO layer. The IBAD-MgO templates were fabricated using the IBAD system with 216 cm-length deposition zone and 32 cm diameter ion source. The texture of MgO films developed during the IBAD process was monitored by in-situ reflection high energy electron diffraction(RHEED) to optimize the IBAD process. Recently, 100 m long IBAD-MgO tape with in-plane texture of $\Delta{\phi}<10^{\circ}$ was successfully fabricated using the modified IBAD system. In this report, the detailed deposition condition of getting a long length IBAD-MgO template with a good epitaxy is described.