• 제목/요약/키워드: temperature-compensated

검색결과 209건 처리시간 0.025초

A 70 MHz Temperature-Compensated On-Chip CMOS Relaxation Oscillator for Mobile Display Driver ICs

  • Chung, Kyunghoon;Hong, Seong-Kwan;Kwon, Oh-Kyong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권6호
    • /
    • pp.728-735
    • /
    • 2016
  • A 70 MHz temperature-compensated on-chip CMOS relaxation oscillator for mobile display driver ICs is proposed to reduce frequency variations. The proposed oscillator compensates for frequency variation with respect to temperature by adjusting the bias currents to control the change in delay of comparators with temperature. A bandgap reference (BGR) is used to stabilize the bias currents with respect to temperature and supply voltages. Additional temperature compensation for the generated frequency is achieved by optimizing the resistance in the BGR after measuring the output frequency. In addition, a trimming circuit is implemented to reduce frequency variation with respect to process. The proposed relaxation oscillator is fabricated using 45 nm CMOS technology and occupies an active area of $0.15mm^2$. The measured frequency variations with respect to temperature and supply voltages are as follows: (i) ${\pm}0.23%$ for changes in temperature from -30 to $75^{\circ}C$, (ii) ${\pm}0.14%$ for changes in $V_{DD1}$ from 2.2 to 2.8 V, and (iii) ${\pm}1.88%$ for changes in $V_{DD2}$ from 1.05 to 1.15 V.

무선 임피던스 센서노드를 이용한 강-볼트 접합부의 임피던스기반 손상모니터링에 미치는 온도 영향 (Temperature Effect on Impedance-based Damage Monitoring of Steel-Bolt Connection using Wireless Impedance Sensor Node)

  • 홍동수;김정태
    • 한국해양공학회지
    • /
    • 제26권1호
    • /
    • pp.27-33
    • /
    • 2012
  • This paper presents the effect of temperature on the impedance-based damage monitoring of steel-bolt connections using wireless impedance sensor nodes. In order to achieve the objective, the following approaches are implemented. First, a temperature-compensated damage monitoring scheme that includes a temperature compensation model and damage detection method is described. The temperature compensation model is designed by analyzing the linear regressions between the temperatures and impedance signatures. The correlation coefficient of the impedance signatures is selected as the damage index to monitor the damage occurrence in the target structures. Second, a wireless impedance sensor node is described for the design of the hardware components and embedded software. Finally, the performance of the temperature-compensated impedance-based damage monitoring scheme is evaluated for detecting a loose bolt in the steel-bolt connections on a lab-scale steel girder under various temperatures.

공정, 전압, 온도 보상 회로를 이용한 On-Chip CMOS Oscillator (On-Chip CMOS Oscillator using PVT Compensated Circuit)

  • 한도희;권익진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.593-594
    • /
    • 2008
  • In this article, process voltage temperature (PVT) compensated on-chip oscillator is implemented by using proportional to absolute temperature (PTAT) circuit and process compensator. Process compensator circuit based on current subtracter and PTAT circuit are proposed for compensation of oscillation frequency to cope with process variation and temperature variation. All circuit can operate in the range of $3.5{\sim}5\;V$ supply voltage. It can be applied to PVT insensitive low frequency clock reference generator.

  • PDF

A New Curvature-Compensated CMOS Bandgap Reference with Low Power Consumption

  • Gil, JoonHo;Je, Minkyu;Cho, YoungHo;Shin, Hyungcheol
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -2
    • /
    • pp.612-614
    • /
    • 2000
  • We propose a new curvature-compensated CMOS bandgap reference circuit that is achieved by varying a current ratio. The proposed circuit is shown to have small temperature coefficient that the output voltage variation is 0.4mV.

  • PDF

목본식물 형성층 전기저항에 영향을 주는 환경 요인 (Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants)

  • 김동욱;김민수;이부용
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

Bi0.5(Na0.84K0.16)0.5TiO3 세라믹스로 보상된 AT-cut 수정 공진자의 주파수 온도특성 (Frequency-temperature Characteristics of AT-cut Crystal Resonator Compensated by Bi0.5(Na0.84K0.16)0.5TiO3 Ceramics)

  • 오동언;문경현;류주현
    • 한국전기전자재료학회논문지
    • /
    • 제18권7호
    • /
    • pp.610-614
    • /
    • 2005
  • In this paper, simple AT-cut crystal resonator utilizing $Bi_{0.5}(Na_{0.84}K_{0.16})_{0.5}TiO_3$ relaxator ceramics as load capacitator were designed and their frequency-temperature characteristics were investigated. In order to modify temperature dependance of dielectric constant, $Bi_{0.5}(Na_{0.84}K_{0.16})_{0.5}TiO_3$ ceramics were manufactured with the variations in Sr substitution. At the composition with $6\;mol\%$ Sr substitution as load capacitator, frequency-temperature characteristics of AT-cut crystal resonators with the series load capacitance were similarly varied as those of cut orientation variation, and also compensated.

전기 저항식 습도 센서를 이용한 온도 보상된 습도계 설계 (A Temperature-Compensated Hygrometer Using Resistive Humidity Sensors)

  • 정원섭
    • 전자공학회논문지SC
    • /
    • 제43권6호
    • /
    • pp.27-32
    • /
    • 2006
  • 전기 저항식 습도 센서를 이용하여 온도 보상된 습도계를 개발하였다. 개발된 습도계는 사인파 발생기, 대수 변환기, 정류기, 그리고 증폭기로 구성되며, 사용된 센서의 선형화와 온도 보상을 수행한다. 습도계의 동작 원리를 제시하였고, 실험 결과들을 이용하여 이론적인 예측의 타당성을 증명하였다. 실험 결과는 습도계의 변환 감도가 약 24.8 mV/%RH이고 변환 특성의 선형 오차가 30에서 80 %RH의 상대습도 범위에서 17.2 %보다 작다는 것을 보여준다. 실험 결과는 또, 출력 전압의 온도 계수가 22에서 $40^{\circ}C$의 온도 범위에서 $10149ppm/^{\circ}C$ 이하라는 것을 보여준다.

보정된 X-색도 좌표를 이용한 색온도 변환 시스템의 성능 개선 및 구현 (Performance Improvement and Implementation of Color-Temperature Conversion System using Compensated X-Chromaticity Coordinate)

  • 변형수;강봉순;양훈기
    • 대한전자공학회논문지SD
    • /
    • 제41권1호
    • /
    • pp.61-70
    • /
    • 2004
  • 본 논문은 보정된 X-색도 좌표를 이용한 색온도 변환 방법을 제안하고자 한다. 제안된 방법은 기존의 색온도 변환 시스템에서 문제점인 색온도 계산값의 오차를 줄이기 위하여 회귀방정식을 사용한다 또한, 광범위한 영역에서 색온도 변환을 실현하기 위하여 색온도 영역을 1,667K에서 25,000K까지 확대하고자 한다. 제안한 방법은 Robertson 방법 및 기존의 색온도 계산방법과 성능의 비교분석을 통하여 타당성을 보이고자 한다. 본 논문에서 제안된 방법은 하드웨어로 설계하여 Xilinx FPGA인 XCV2000E-BG560를 통하여 TV 시스템에서 실시간으로 동작을 검증한다.

온도보상형 전기저항 프로브의 현장 적용성 평가 (Application of Temperature-compensated Resistivity Probe in the Field)

  • 정순혁;윤형구;이종섭
    • 대한토목학회논문집
    • /
    • 제31권4C호
    • /
    • pp.117-125
    • /
    • 2011
  • 최근 신뢰성 높은 지반조사를 실시하기 위하여 국부적인 영역에서 해상도 높은 데이터의 획득이 가능한 전기비저항의 활용이 증가하고 있다. 본 연구의 목적은 온도 효과를 고려하여 보다 신뢰성 높은 전기비저항 값의 획득을 위한 현장용 온도 보상형 전기비저항 프로브의 개발 및 현장 적용성 평가이다. 프로브에 삽입된 온도센서는 온도전이 실험결과와 실험시 안정성 등을 고려하여 선단부로부터 15mm, 30mm, 그리고 90mm 지점에 부착하였고, 프로브 관입시 지반의 교란과 기하학적 형상을 고려하여 콘 형태로 제작하였으며 선단부의 각도는 $60^{\circ}$로 결정하였다. 현장실험에 사용되는 표준 콘과의 비교를 위하여 직경은 표준 콘과 동일한 35.7mm로 제작하였으며, 관입 속도도 동일하게 20mm/sec로 적용하였다. 관입 실험 시, 콘이 지반에 관입 되는 순간 약 $4^{\circ}C$의 온도 변화를 관찰하였으며 이를 보정하여 표준 콘에서 획득한 값과 비교하면 전기비저항을 이용한 지반조사시 반드시 온도에 대한 영향을 고려해야 함을 알 수 있었다. 본 연구에서는 현장용 온도보상형 전기비저항 프로브의 개발 및 현장검증을 통하여 관입 실험 시 온도 보정이 반드시 필요함을 보여준다.

온도에 따른 저급 IMU의 특성 분석 및 보상 (Temperature Compensation and Analysis of an Low-cost IMU)

  • 진용;박찬국;지규인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2365-2367
    • /
    • 2000
  • The deterministic errors of semiconductor gyros and accelerometers must be estimated and compensated to develop the low-cost IMU using them. Generally, the dominant errors of the low-cost IMU are bias and misalignment errors. Bias is sensitive to temperature. Therefore, in this paper, the effect on temperature of bias is analyzed and temperature compensation are carryed out. It is shown by experiment that the compensation is efficient.

  • PDF