• 제목/요약/키워드: temperature inversion

검색결과 303건 처리시간 0.023초

사각 밀폐용기 내부의 밀도최대치를 가지는 유체의 공진현상 (Oscillatory enclosed buoyant convection of a fluid with the density maximum)

  • 이창호;현재민;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.311-315
    • /
    • 2000
  • A numerical investigation is made of time-dependent buoyant convection in a square of a non-Boussinesq fluid. The density-temperature$({\rho}-T)$ relation is modeled by a quadratic function, with the maximum density ${\rho}_M$ at temperature $T_M$. The horizontal walls of the square are insulated, and a pulsating temperature $T_H=T_M+{\Delta}T'\;sin({\omega}{\tau})$ is imposed on the hot vertical sidewall. The temperature at the cold wall $T_c$ is constant. Extensive numerical solutions to the governing Navier-Stokes equations are portrayed. Resonance is identified by monitoring the amplitude of the mid-plane Nusselt number, $A(Nu^*)$. The primary resonance frequency is found by matching ${\omega}$ to the nondimensional basic mode $N_1$ of internal gravity oscillations. Due to the quadratic$({\rho}-T)$ relationship, the effective pulsation frequency for density, $2{\omega}$, is meaningful, which brings forth the secondary resonance frequency, i.e., $2{\omega}=N_1$

  • PDF

경사냉각면에 따른 함수정방형내의 동결현상에 관한 실험적 연구 (An experimental study on freezing phenomena of water saturated square cavity with inclined cold surface)

  • 이춘희;김종준;김병철
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.435-445
    • /
    • 1997
  • It was studied the phenomena of transient freezing of an inclined water-saturated enclosure. One side of the test section was cooled and the other sides were insulated. The effects of the initial temperature, the inclination angle on the temperature field and the shape of the ice-water interface were observed. In the beginning of freezing, with increasing the inclination angle the freezing rate was increased and in the stable density layer centered $4^{\circ}C$, the freezing was fast as the convective fluid flow became small. When the initial temperature was above the $4^{\circ}C$, the frozen thickness in the upper part of inclined surface was thinner than that in the lower part, but with time the frozen thickness of upper part was thicker than that of lower part, below the $4^{\circ}C$, the frozen thickness in the upper part was thicker than that of lower part from the begining, and above the $8^{\circ}C$ in the beginning upper part was thinner with concave, but with time thicker the upper part, vanishing concave.

  • PDF

대기 혼합층 발달 과정의 모형 실험과 수치 해석 (Laboratory Experimentals and Numerical Analysis for Development of a Atmospheric Mixed Layer)

  • 이화운
    • 한국환경과학회지
    • /
    • 제2권1호
    • /
    • pp.17-26
    • /
    • 1993
  • The layer that is directly influenced by ground surface is called the atmospheric boutsdary layer in comparison with the free atmosphere of higher layer. In the boundary layer, the changes of wind, temperature and coefficient of turbulent diffusion in altitude are large and have great influences an atmospheric diffusion. The purpose of this paper is to express the structure and characteristics of development of mixed layer by using laboratory experiment and numerical simulation. Laboratory experiment using water tank are performed that closely simulate the process of break up of nocturnal surface inversion above heated surface and its phenomena are analyzed by the use of horizontally averaged temperature which is observed. The result obtained from the laboratory experiment is compared with theoretical ones from ; \textsc{k}-\varepsilon numerical model. The results are summarized as follows. 1) The horizontally averaged temperature was found to vary smoothly with height and the mixed layer developed obviously being affected by the convection. 2) The mean height of mixed layer may be predicted as a function of time, knowing the mean initial temperature gradient. The experimental values are associated well with the theoretical values computed for value of the universal constant $C_r$= 0.16, our $C_r$ value is little smaller than the value found by Townsend and Deardoru et al.

  • PDF

Ultrashort Echo Time MRI (UTE-MRI) Quantifications of Cortical Bone Varied Significantly at Body Temperature Compared with Room Temperature

  • Jerban, Saeed;Szeverenyi, Nikolaus;Ma, Yajun;Guo, Tan;Namiranian, Behnam;To, Sarah;Jang, Hyungseok;Chang, Eric Y.;Du, Jiang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.202-209
    • /
    • 2019
  • Purpose: To investigate the temperature-based differences of cortical bone ultrashort echo time MRI (UTE-MRI) biomarkers between body and room temperatures. Investigations of ex vivo UTE-MRI techniques were performed mostly at room temperature however, it is noted that the MRI properties of cortical bone may differ in vivo due to the higher temperature which exists as a condition in the live body. Materials and Methods: Cortical bone specimens from fourteen donors ($63{\pm}21$ years old, 6 females and 8 males) were scanned on a 3T clinical scanner at body and room temperatures to perform T1, $T2^*$, inversion recovery UTE (IR-UTE) $T2^*$ measurements, and two-pool magnetization transfer (MT) modeling. Results: Single-component $T2^*$, $IR-T2^*$, short and long component $T2^*s$ from bi-component analysis, and T1 showed significantly higher values while the noted macromolecular fraction (MMF) from MT modeling showed significantly lower values at body temperature, as compared with room temperature. However, it is noted that the short component fraction (Frac1) showed higher values at body temperature. Conclusion: This study highlights the need for careful consideration of the temperature effects on MRI measurements, before extending a conclusion from ex vivo studies on cortical bone specimens to clinical in vivo studies. It is noted that the increased relaxation times at higher temperature was most likely due to an increased molecular motion. The T1 increase for the studied human bone specimens was noted as being significantly higher than the previously reported values for bovine cortical bone. The prevailing discipline notes that the increased relaxation times of the bound water likely resulted in a lower signal loss during data acquisition, which led to the incidence of a higher Frac1 at body temperature.

Three-dimensional Numerical Prediction on the Evolution of Nocturnal Thermal High (Tropical Night) in a Basin

  • Choi, Hyo;Kim, Jeong-Woo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제25권1호
    • /
    • pp.57-81
    • /
    • 1997
  • Numerical prediction of nocturnal thermal high in summer of the 1995 near Taegu city located in a basin has been carried out by a non-hydrostatic numerical model over complex terrain through one-way double nesting technique in the Z following coordinate system. Under the prevailing westerly winds, vertical turbulent fluxes of momentum and heat over mountains for daytime hours are quite strong with a large magnitude of more than $120W/\textrm{m}^2$, but a small one of $5W/\textrm{m}^2$ at the surface of the basin. Convective boundary layer (CBL) is developed with a thickness of about 600m over the ground in the lee side of Mt. Hyungje, and extends to the edge of inland at the interface of land sea in the east. Sensible heat flux near the surface of the top of the mountain is $50W/\textrm{m}^2$, but its flux in the basin is almost zero. Convergence of sensible heat flux occurs from the ground surface toward the atmosphere in the lower layer, causing the layer over the mountain to be warmed up, but no convergance of the flux over the basin results from the significant mixing of air within the CBL. As horizontal transport of sensible heat flux from the top of the mountain toward over the basin results in the continuous accumulation of heat with time, enhancing air temperature at the surface of the basin, especially Taegu city to be higher than $39.3^{\circ}C$. Since latent heat fluxes are $270W/\textrm{m}^2$ near the top of the mountain and $300W/\textrm{m}^2$ along the slope of the mountain and the basin, evaporation of water vapor from the surface of the basin is much higher than one from the mountain and then, horizontal transport of latent heat flux is from the basin toward the mountain, showing relative humidity of 65 to 75% over the mountain to be much greater than 50% to 55% in the basin. At night, sensible heat fluxes have negative values of $-120W/\textrm{m}^2$ along the slope near the top of the mountain and $-50W/\textrm{m}^2$ at the surface of the basin, which indicate gain of heat from the lower atmosphere. Nighttime radiative cooling produces a shallow nocturnal surface inversion layer with a thickness of about 100m, which is much lower than common surface inversion layer, and lifts extremely heated air masses for daytime hours, namely, a warm pool of $34^{\circ}C$ to be isolated over the ground surface in the basin. As heat transfer from the warm pool in the lower atmosphere toward the ground of the basin occurs, the air near the surface of the basin does not much cool down, resulting in the persistence of high temperature at night, called nocturnal thermal high or tropical night. High relative humidity of 75% is found at the surface of the basin under the moderate wind, while slightly low relative humidity of 60% is along the eastern slope of the high mountain, due to adiabatic heating by the srong downslope wind. Air temperature near the surface of the basin with high moisture in the evening does not get lower than that during the day and the high temperature produces nocturnal warming situation.

  • PDF

Raman Lidar for the Measurement of Temperature, Water Vapor, and Aerosol in Beijing in the Winter of 2014

  • Tan, Min;Shang, Zhen;Xie, Chenbo;Ma, Hui;Deng, Qian;Tian, Xiaomin;Zhuang, Peng;Zhang, Zhanye;Wang, Yingjian
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.15-22
    • /
    • 2018
  • To measure atmospheric temperature, water vapor, and aerosol simultaneously, an efficient multi-function Raman lidar using an ultraviolet-wavelength laser has been developed. A high-performance spectroscopic box that utilizes multicavity interference filters, mounted sequentially at small angles of incidence, is used to separate the lidar return signals at different wavelengths, and to extract the signals with high efficiency. The external experiments are carried out for simultaneous detection of atmospheric temperature, water vapor, and aerosol extinction coefficient in Beijing, under clear and hazy weather conditions. The vertical profiles of temperature, water vapor, and aerosol extinction coefficient are analyzed. The results show that for an integration time of 5 min and laser energy of 200 mJ, the mean deviation between measurements obtained by lidar and radiosonde is small, and the overall trend is similar. The statistical temperature error for nighttime is below 1 K up to a height of 6.2 km under clear weather conditions, and up to a height of 2.5 km under slightly hazy weather conditions, with 5 min of observation time. An effective range for simultaneous detection of temperature and water vapor of up to 10 km is achieved. The temperature-inversion layer is found in the low troposphere. Continuous observations verify the reliability of Raman lidar to achieve real-time measurement of atmospheric parameters in the troposphere.

한국 서해의 수온역전 현상 (Inversion Phenomena of Temperature in the Yellow Sea)

  • 김희준;윤홍주;양성기
    • 수산해양기술연구
    • /
    • 제18권2호
    • /
    • pp.91-96
    • /
    • 1982
  • 1965년부터 1979년까지의 해양관측자료를 사용하여 우리나라 서해에서 일어나는 수온역전 현상을 조사하였다. 그 결과는 다음과 같다. (1) 겨울의 수온역전 현상은 전 해역과 모든 수심에 걸쳐서 일어난다. (2) 여름은 제주도 서방 해역에서만 비교적 많이 일어난다. 이와 같은 수온역전 현상은 겨울의 경우는 현열손실, 잠열손실 및 남하 Ekman 수송 등에 의한 표면 냉각효과 때문으로 생각된다. 여름의 경우는 온도와 염분의 성질이 서로 다른 황해 저층수와 황해 난류가 제주도 서방 해역에서 경계를 이루고, 서로 혼합되는 과정에서 생기는 것으로 보여진다.

  • PDF

정전압 구동에 의한 레이저 다이오드의 광출력 안정화 (Optical power stabilization of a laser diode by constant voltage)

  • 이성호
    • 한국광학회지
    • /
    • 제8권2호
    • /
    • pp.116-121
    • /
    • 1997
  • 주위온도에 따른 레이저다이오드의 광출력의 변화는 정전류로 구동하는 경우와 정전압으로 구동하는 경우에 서로 다르다. 레이저다이오드를 정전류로 구동하는 경우에는 온도증가에 따라 밀도반전이 감소하므로 광출력이 감소한다. 그러나 정전압으로 구동하는 경우에는 이러한 열효과에 의한 광출력의 감소이외에 내부저항과 임계전압의 감소에 의한 주입전류의 증가효과가 있어서 열효과를 일부 상쇄하므로 광출력의 변화가 정전류로 구동할 때보다 적다. 특히 정전압으로 레이저다이오드를 구동하는 경우에 이 두가지 효과에 의한 광출력의 변화폭이 비슷하여 서로 상쇄되는 동작점 부근에서는 온도에 따른 광출력의 변화가 아주 적어져 정전류로 구동하는 때보다 훨씬 광출력이 안정함을 실험적으로 확인하였다.

  • PDF

폴리실리콘 기판 위에 형성된 코발트 니켈 복합실리사이드 박막의 열처리 온도에 따른 물성과 미세구조변화 (Characteristics and Microstructure of Co/Ni Composite Silicides on Polysilicon Substrates with Annealing Temperature)

  • 김상엽;송오성
    • 한국재료학회지
    • /
    • 제16권9호
    • /
    • pp.564-570
    • /
    • 2006
  • Silicides have been required to be below 40 nm-thick and to have low contact resistance without agglomeration at high silicidation temperature. We fabricated composite silicide layers on the wafers from Ni(20 nm)/Co(20 nm)/poly-Si(70 nm) structure by rapid thermal annealing of $700{\sim}1100^{\circ}C$ for 40 seconds. The sheet resistance, surface composition, cross-sectional microstructure, and surface roughness were investigated by a four point probe, a X-ray diffractometer, an Auger electron spectroscopy, a field emission scanning electron microscope, and a scanning probe microscope, respectively. The sheet resistance increased abruptly while thickness decreased as silicidation temperature increased. We propose that the fast metal diffusion along the silicon grain boundary lead to the poly silicon mixing and inversion. Our results imply that we may consider the serious thermal instability in designing and process for the sub-0.1 um CMOS devices.

INFRARED EMISSION FROM SPHERICAL DUST CLOUDS

  • Lee, Hyung-Mok;Hong, Seung-Soo;Yun, Hong-Sik;Lee, Sang-Gak
    • 천문학회지
    • /
    • 제25권2호
    • /
    • pp.111-128
    • /
    • 1992
  • Infrared emissions from spherical dust, clouds are calculated using quasi-diffusion method. We have employed graphite-silicate mixture with power-law size distribution for the dust model. The grains are assumed to be heated and cooled by radiative processes only. The primary heating source is diffuse interstellar radiation field. hut the cases with an embedded source are also considered. Since graphite grains have higher temperature than silicate grains, the observed IR emission is mainly due to graphite grains, unless the fraction of graphite grains is negligibly small. The color temperature of Bok globules obtained from IRAS 60 and $100{\mu}m$ data are found to be consistent with the dust cloud with graphite-silicate mixture exposed to average interstellar radiation field. The color temperature is sensitive to the external radiation field, but rather insensitive to the size distribution of the grains. We found that the density distribution can be recovered outside the beam size using the inversion technique that assumes negligible optical depth. However, the information within the beam size is lost for if beam convolved intensity distributions are used in deriving density profile.

  • PDF