Numerical Study of Double Diffusive Convection of a Stratified Fluid in an Annulus Due to Lateral Heating (환형밀폐용기내 성층화된 유체의 옆면가열에 의한 이중확산대류에 관한 수치해석)

  • 강신형;전창덕;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1720-1730
    • /
    • 1995
  • Finite-difference analysis was conducted to study the natural convection of a stably stratified salt-water solution in an annulus due to lateral heating. The main purpose of this study is to examine in detail the multi-layered flow structure. Calculation was thus made for R $a_{\eta}$=2*10$^{5}$ and 6.5*10$^{5}$ . Formation of layered flow structure, merging process of layers, the corresponding temperature and concentration distributions, Nusselt number variations with time are examined. Numerical results show that in each layer, the temperature profile looks 'S`-shaped and the concentration profile is uniform due to the convective mixing. The formation of the roll and the layer is governed by natural convection due to the temperature gradient and the merging process of the layer by diffusion of the concentration.ation.

Delineation of Groundwater and Estimation of Seepage Velocity Using High-Resolution Distributed Fiber-Optic Sensor

  • Chang, Ki-Tae;Pham, Quy-Ngoc
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.6
    • /
    • pp.39-43
    • /
    • 2015
  • This study extends the Distributed Temperature Sensing (DTS) application to delineate the saturated zones in shallow sediment and evaluate the groundwater flow in both downward and upward directions. Dry, partially and fully saturated zones and water level in the subsurface can be recognized from this study. High resolution seepage velocity in vertical direction was estimated from the temperature data in the fully saturated zone. By a single profile, water level can be detected and seepage velocity in saturated zone can be estimated. Furthermore, thermal gradient analysis serves as a new technique to verify unsaturated and saturated zones in the subsurface. The vertical seepage velocity distribution in the recognized saturated zone is then analyzed with improvement of Bredehoeft and Papaopulos' model. This new approach provides promising potential in real-time monitoring of groundwater movement.

Thermal buckling resistance of simply supported FGM plates with parabolic-concave thickness variation

  • Benlahcen, Fouad;Belakhdar, Khalil;Sellami, Mohammed;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.29 no.5
    • /
    • pp.591-602
    • /
    • 2018
  • This research presents an investigation on the thermal buckling resistance of FGM plates having parabolic-concave thickness variation exposed to uniform and gradient temperature change. An analytical formulation is derived and the governing differential equation of thermal stability is solved numerically using finite difference method. A specific function of thickness variation is introduced where it controls the parabolic variation intensity of the thickness without changing the original material volume. The results indicated that the loss ratio in buckling resistance is the same for any gradient temperature profile. Influencing geometrical and material parameters on the loss ratio in the thermal resistance buckling are investigated which may help in design guidelines of such complex structures.

Analysis of the Seasonal Change in Attached Algae and Microbial Community Structure in Sediment Basin Trough of Water Treatment Plant By Using Quinone Profile and PCR-DGGE (Quinone profile과 PCR-DGGE를 이용한 정수장 침전지에서의 부착조류 및 미생물군집의 계절적 변화해석)

  • Yu, Hyun-Sun;Lim, Byung-Ran;Ahn, Kyu-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.461-467
    • /
    • 2006
  • The seasonal change in attached algae and microbial community structure at sedimentation basin of water treatment plant was investigated by using quinone profiles and denaturing gel gradient electrophoresis (DGGE). The photosynthetic bacteria and algae contains PQ-9 and VK-1 as major quinone are major component of the total quinone fraction in attached algae and microorganisms on sedimentation basin trough. The microorganisms containing menaquinones appear to be sensitivity to the change in temperature than those containing ubiquinones. The plot of the mole fraction of dominant quinone species ($f_d$) to the DQ values showed higher sensitivity to the seasonal change in the microbial community structure. The results indicated that quinone and DGGE are useful tool for the evaluation of the changes in the microbial community structure.

Development of Algorithms for Extracting Thermocline Parameters in the South Sea of Korea (한국 남부해역의 수온약층 추출 알고리즘 개발)

  • Yoon, Dong-Young;Choi, Hyun-Woo
    • Ocean and Polar Research
    • /
    • v.34 no.2
    • /
    • pp.265-273
    • /
    • 2012
  • A new algorithm was developed, not only to detect the existence of a thermocline, but also to extract the thermocline parameters (such as thermocline thickness, mixed layer thickness, maximum temperature gradient, and temperature difference of thermocline), using the vertical profile of water temperature. According to Kappa analysis, in order to find adequate threshold values of vertical water temperature gradients ${\Delta}T$ ($^{\circ}C/m$), agreement and reliability were 87% and 0.74 respectively, in the conditions of maximum ${\Delta}T{\geq}0.5$ and surface and bottom layers ${\Delta}T<{\mid}0.2{\mid}$. Also, three different kinds of methods, viz. 1. Gradient method, 2. Hyperbolic tangent method, and 3. Differential hyperbolic tangent method, were tested to extract the key parameters of a thermocline. Comparing the results of three different methods, the differential hyperbolic tangent method was the most appropriate to extract the start and end point of a thermocline curve.

Vertical Temperature Profile in the Yellow Sea according to the Variations of Air Temperature

  • CHO Kyu-Dae;CHO Kwang-Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 1988
  • The vertical temperature profiles of the Yellow Sea in summer are investigated by means of the nine air temperature (AT) patterns which are classified with the AT of winter and summer. The sea surface temperature (SST) is high when the AT of summer is high, and vice versa. The gradient of thermocline in the offshore region is higher than that in the coastal region and is not always favorable with the AT patterns. The relation between sea bottom temperature (SBT) and the AT of winter is favorable when the SBT is averaged in the coastal and offshore stations. In addition, the SST of coastal stations is higher than that of offshore stations because of the strong mixing by the tidal current in the coastal region. The correlation between the AT and the SST of August is favorable (r=0.44-0.69), while the correlation between the AT of February and the SBT of August is not favorable except the stations, A2 (r=0.57) and B2 (r=0.61).

  • PDF

Measurement of temperature profile using the infrared thermal camera in turbulent stratified liquid flow for estimation of condensation heat transfer coefficients

  • Choi, Sung-Won;No, Hee-Cheon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.107-107
    • /
    • 1999
  • Direct-contact condensation experiments of atmospheric steam and steam/air mixture on subcooled water flowing co-currently in a rectangular channel are carried out uszng an infrared thermal camera system to develop a temperature measurement method. The inframetrics Model 760 Infrared Thermal Imaging Radiometer is used for the measurement of the temperature field of the water film for various flow conditions. The local heat transfer coefficient is calculated using the bulk temperature gradient along the (low direction. It is also found that the temperature profiles can be used to understand the interfacial condensation heat transfer characteristics according to the flow conditions such as noncondensable gas effects, inclination effect, and flow rates.

  • PDF

Distribution of Salinity and Temperature due to the Freshwater Discharge in the Yeongsan Estuary in the Summer of 201 (2010년 여름 담수방류에 의한 영산강 하구의 염분 및 수온 분포 변화)

  • Park, Hyo-Bong;Kang, Kiryong;Lee, Guan-Hong;Shin, Hyun-Jung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.17 no.3
    • /
    • pp.139-148
    • /
    • 2012
  • The short-term variation of salinity and temperature in a dyked estuarine environment is mainly controlled by the freshwater discharge from the dyke. We examined the distribution of salinity and temperature by the freshwater discharge in the Yeongsan River estuary using the CTD data obtained from 8 stations through three surveys in June (weak discharge) and August (intensive discharge), 2010. During the weak discharge in June, the surface salinity showed 30-32.5 psu and its horizontal gradient was relatively high around Goha-do (0.25~0.32 psu/km). On the other hand, the salinity of the bottom layer was almost constant in the range of 33 psu. Water temperature ranged $19{\sim}21^{\circ}C$ and displayed higher gradient in north-south direction than the gradient of east-west direction. During the intensive freshwater discharge on August 12, the salinity dropped to 9~26 psu. The maximum horizontal gradient of surface salinity reached 3.8 psu/km in the north of Goha-do where the strong salinity front was formed, and the horizontal salinity gradient of bottom layer was 0.28 psu/km. The horizontal gradient of water temperature was $-0.45^{\circ}C/km$ in the surface and $-0.12^{\circ}C/km$ in the bottom with high surface temperature near the dyke and decreasing gradually to the river mouth. After 3 days of the intensive discharge ($3^{rd}$ survey), the surface salinity increased to 22~26 psu. However, there still existed relatively high horizontal gradient around Goha-do. In the mean time, the bottom salinity decreased to 26.5~27.5 psu, but its gradient was not big as much as the surface gradient. According to time series of CTD profile near the dyke, the discharged fresh water jetted down temporarily and then recovered gradually with the recovering speed of 0.4 m/hour for the discharge case of $13{\times}10^6$ ton. Due to the combined effects of freshwater discharge and surface heating during the summer of 2010, the Yeongsan estuary, in general, underwent intensified vertical stratification, which in turn caused the inhibition of vertical mixing, especially inside area of estuary. Based on the spatial distribution of salinity and temperature, the Yeongsan estuary can be divided into three regions: the Goha-do area with strong horizontal gradient of salinity and temperature, inner estuary from Goha-do to the dyke with low salinity, and outer estuary from Goha-do to the coasts with relatively high salinity.

Comparison of Bacterial Community Changes in Fermenting Kimchi at Two Different Temperatures Using a Denaturing Gradient Gel Electrophoresis Analysis

  • Yeun, Hong;Yang, Hee-Seok;Chang, Hae-Choon;Kim, Hae-Yeong
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.1
    • /
    • pp.76-84
    • /
    • 2013
  • A polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE) technique followed by sequencing of the 16S rDNA fragments eluted from the bands of interest on denaturing gradient gels was used to monitor changes in the bacterial microflora of two commercial kimchi, salted cabbage, and ingredient mix samples during 30 days of fermentation at $4^{\circ}C$ and $10^{\circ}C$. Leuconostoc (Lc.) was the dominant lactic acid bacteria (LAB) over Lactobacillus (Lb.) species at $4^{\circ}C$. Weissella confusa was detected in the ingredient mix and also in kimchi samples throughout fermentation in both samples at $4^{\circ}C$ and $10^{\circ}C$. Lc. gelidum was detected as the dominant LAB at $4^{\circ}C$ in both samples. The temperature affected the LAB profile of kimchi by varing the pH, which was primarily caused by the temperature-dependent competition among different LAB species in kimchi. At $4^{\circ}C$, the sample variations in pH and titratable acidity were more conspicuous owing to the delayed growth of LAB. Temperature affected only initial decreases in pH and initial increases in viable cell counts, but affected both the initial increases and final values of titratable acidity. The initial microflora in the kimchi sample was probably determined by the microflora of the ingredient mix, not by that of the salted cabbage. The microbial distributions in the samples used in this study resembled across the different kimchi samples and the different fermentation temperatures as the numbers of LAB increased and titratable acidity decreased.

An Experimental Study on the Cylinder Wall Temperature Characteristics for Load Variations in a Gasoline Engine (가솔린엔진의 부하(負荷)에 따른 실린더 벽면 온도특성(溫度特性)에 관(關)한 연구(硏究))

  • Kwon, K.R.;Ko, J.K.;Hong, S.C.
    • Journal of Power System Engineering
    • /
    • v.3 no.1
    • /
    • pp.16-22
    • /
    • 1999
  • The purpose of this study is to prevent the stick, scuffing, scratch between piston and cylinder, is to contribute the piston design such as piston profile, clearance by calculating reaction force by over-lap of piston skirt, as measuring the temperature distributions of cylinder wall. The experiment has been peformed to obtain data during actual engine operation. Temperature gradient in peripheral and axial distributions of cylinder wall according to torque and speed of engine were measured by use of an 800cc class gasoline engine. The results obtained are summarized as follows ; 1) The temperature of cylinder wall at TDC was about $50{\sim}75^{\circ}C$ higher than temperature of cooling water. 2) The rear side temperature of top dead center was $141^{\circ}C$(1/4 load) in axial distribution, whereas the rear side of midway position temperature was $98^{\circ}C$. 3) The temperature of cylinder wall increased in according to rising temperature of cooling water. 4) The thrust side temperature of cylinder wall was about $15^{\circ}C$ in all load test. 5) The rear side temperature of top dead center was $159^{\circ}C$ (1/2 load) in peripheral distribution, it was about $39^{\circ}C$ higher than thrust side temperature.

  • PDF