• Title/Summary/Keyword: temperature fluctuation

Search Result 634, Processing Time 0.026 seconds

The Substitution Effect of Boron on Reentrant Behavior of Rapidly Solidified FeMnZr Alloys

  • Moon, Y.M;Kim, K.S;Yu, S.C;Srinivas, V
    • Journal of Magnetics
    • /
    • v.9 no.4
    • /
    • pp.113-115
    • /
    • 2004
  • The magnetization properties have been measured for amorphous $Fe_{82}Mn_{8-x}B_xZr_{10}$ (x = 0-8) alloys. The temperature dependence of magnetization for these alloys shows the existence of antiferromagnetic couplings between Fe atoms in low fields at low temperatures. The magnetic parameters, obtained from the magnetization behavior are consistent with the presence of mixed magnetic state. The Curie temperature and magnetic moment increased with an increase of the concentration of B and spin glass like transition observed at low temperature decreases and finally vanishes at x = 8 at %. Our result suggests that the substitution of B for Mn seems to cause an increase of magnetic order.

Temporal and Spatial Variations of Temperature and Salinity around Ganjeol Point in the Southeast Coast of Korea (한국 남동해 간절곶 주변해역의 열염구조와 시공간적 변동 특성)

  • Choo, Hyo-Sang;Jang, Duck-Jong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.5
    • /
    • pp.474-485
    • /
    • 2014
  • Temporal and spatial variations of temperature and salinity around Ganjeol Point during January, April, August and November 2011 were studied using the data from CTD observations and temperature monitoring buoys deployed at 20 stations in the southeast coast of Korea. Temperature and salinity were nearly homogeneous through the whole depth by mixing of the seawater in spring and winter related to the sea surface cooling. Stratification induced by the river runoff and the bottom cold water was clear in summer. In autumn, sea water had vertical mixing initiated from surface layer and weak stratification at the middle and bottom layers. Low temperature and high salinity emerged throughout the year near Ganjeol Point, which inferred from turbulent mixing and upwelling by its topographical effect. Major periods of 1/4~1.4 day temperature fluctuations were recorded for the most part of the stations. According to the cross spectral density analysis, high coherence and small time lag for temperature fluctuation between layers were shown at Ganjeol Point. However, those features at the northen area of Hoeya river were opposed to Ganjeol Point. From analyses, thermohaline structure and its fluctuation around Ganjeol Point were characterized into those three parts, the south of Ganjeol Point, Ganjeol Point and the north of Ganjeol Point.

Variations of the Sea Surface Temperature Distribution and the Shelf Fronts in the Cheju Strait and the Korea Strait (한국 남해연안의 해표면 수온분포와 천해전선의 변동 특성)

  • 양성기
    • Journal of Environmental Science International
    • /
    • v.3 no.2
    • /
    • pp.111-128
    • /
    • 1994
  • The distributions of sea surface temperature across the Cheju Strait and the Korea Strait have been measured by using a thermometer installed on board No.1 Cheju, a ferry that operates regularly between Pusan and Seogwipo. The data from 14 October 1991 to 15 August 1992 were analyzed in this paper. A clear temperature front is wormed at the adjacent sea of Geomundo, and its position is not fixed and moves north and south. The slow northward movement of the front can easily be traced, but the southward movement from March to October is obscure. The temperature contrast in the Cheju Soait and the Korea Strait is very we in this period. Some periodical fluctuations with a period of several tens of days are observed in the region of the temperature front from November to February. This fluctuation seems to be caused by winter heat flux exchange and the strong southeastward wind force. The result shows that continous observation of the sea surface temperature distribution across the Cheju Strait and the Korea Strait yields a good method for monitoring the presence of Tsushima Warm Current and the fluctuations of South Korea Coastal Water. The formation and structure of shelf front in the Cheju Strait and the Korea Strait was analysed based on the detailed oceanographic data observed during the period of 1990-1992. The analysis shows that well-defined fronts were formed through yearly around the Chuja Island, particularly, in summer. In nature, its structure and formation position can be changed easily from year % year and by season. But, in region of the Korea Strait this front is relatively weak.

  • PDF

Remote Measurement of a Distant Temperature and Current using Fiber Bragg Grating Sensors and Erbium-doped Fiber Ring Laser (어븀 첨가 광섬유형 링 레이저와 광섬유 격자 기반 센서를 이용한 원거리의 온도 및 전류 측정)

  • Sohn, Kyung-Rak;Shim, June-Hwan;Yang, Gyu-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1257-1262
    • /
    • 2008
  • A long-distance remote sensing of temperature and current based on a fiber Bragg grating (FBG) is proposed and demonstrated. The thermal expanding effect of the epoxy and the Er-doped fiber ring laser (EFRL) are applied to the sensor system to enhance the temperature and current sensitivity. An EFRL with a 5 km-single-mode fiber and a FBG shows a high extinction ratio of more than 60 dB and a low power fluctuation of less than 1 dB. The metal wires are used to supply the current to the sensors. When the NOA65 puts on the FBG as a thermal expanding material, the temperature and current sensitivity of the lasing wavelength shift are about $30\;pm/^{\circ}C$ and 3pm/mA, respectively. The proposed sensing scheme is useful for measurement of current or temperature at a distant object of more than several km.

Effects of Temperature on Flocculation Kinetics Using Fe(III) Coagulant in Water Treatment (정수처리시 Fe(III) 응집제를 사용한 응집동력학에 대한 온도의 영향)

  • 강임석
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.181-194
    • /
    • 1995
  • Flocculation kinetics using ferric nitrate as a coagulant to coagulate kaolin clay in water was examined as a tool to investigate the effect of low temperature under tightly controlled treatment conditions. Both the particle size distribution data obtained from Automatic Image Analysis (AIA) system and the on-line measurement of the degree of turbidity fluctuation in a flowing suspension by Photometric Dispersion Analyzer (PDA) were used to measure flocculation kinetics. Results show that cold water temperature had a pronounced detrimental effect on flocculation kinetics. For improving flocculation kinetics at low water temperature, maintaining constant pOH to adjust water chemistry for temperature changes was found to be partially effective only in the more acidic pH range studied.

  • PDF

Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test (엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석)

  • Yang, In-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

The Implementation of high temperature displacement sensors and sensors drive system for Air-preheater (공기예열기를 위한 고온용 변위센서 및 센서드라이브 시스템 구현)

  • Cho, Hyang-Duck;Kim, Woo-Shik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.453-458
    • /
    • 2011
  • Air preheater uses the waste heat of the gas which burnt from the boiler from the thermal power plant. Air preheater it is established in the exit of the boiler follows in change of temperature combustion gas and the vibration which it follows in thermal expansion and contraction occurs. Air preheater with ruse the gas the seal the place where it includes a gap in the structure which it does, the vibration which it follows in change of temperature fluctuates the displacement of gap, fluctuation of the leakage quantity which occurs from gap there is a possibility of decreasing an effect to system. Part system it will be able to control the interval of gap in order, control mechanism about under establishing the place where it does the gap control actively, measures a gap the displacement sensor for is necessary. Like this displacement sensor the condition must do continuous running from atmosphere of high temperature was demanded all. This paper investigates the implementation instance of hazard existing which implement the high temperature displacement sensor, it analyzes, produces the result which it examines a model, it was a presentation. These results with the fact that it will contribute in the research for the implementation and a localization of the high temperature displacement sensor and advanced air preheater.

  • PDF

Deformation Estimation of Slope Reinforced Materials by Rain and Temperature (사면보강재의 강우 및 온도에 의한 변형 해석)

  • Hong, Sung-Jin;Chang, Ki-Tae;Han, Heui-Soo
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • It is necessary, in the light of the importance of long-term slope stability problem, to develop a simple method or tool which can figure out the possible failure zone resulted from weathering effect and other factors. The FBG sensor system is used to estimate the correlations between the temperature and the slope in Yunhwajae, and to find a failure zone in slopes effectively. This research is to seek for the correlation between the soil temperature distribution and the strain distribution in a active zone by analyzing the data from the in-situ measurement so that the possible failure zone should be well defined based on the correlation. The zone of high temperature fluctuation can be regarded as one of the possible sliding zone due to the weathering effect while the constant temperature depth of the ground, if exists, would not be relatively affected by the weathering process.

  • PDF

Optoelectronics Properties of In0.27Ga0.73N/GaN Multi-Quantum-Well Structure (In0.27Ga0.73N/GaN 다중 양자우물 구조에 대한 광전기적 특성)

  • Park, Hun-Bo;Bae, In-Ho;Kim, Ki-Hong
    • Korean Journal of Materials Research
    • /
    • v.17 no.9
    • /
    • pp.489-492
    • /
    • 2007
  • Temperature and injection current dependence of elctroluminescence(EL) spectral intensity of the $In_{0.27}Ga_{0.73}N/GaN$ multi-quantum-well(MQW) have been studied over a wide temperature and as a function of injection current level. EL peaks also show significant broadening into higher photon energy region with the increase of injection current. This is explained by the band-filling effect. When temperature is slightly increased to 300 from 15 K, the EL emission peak showed red-blue-red shift. It can be explained by the carrier localization by potential fluctuation of multiple quantum well and band-gap shrinkage as temperature increase. It is found that a temperature-dependent variation pattern of the EL efficiency under very low and high injection currents show a drastic difference. This unique EL efficiency variation pattern with temperature and current is explained field effects due to the driving forward bias in presence of internal(piezo and spontaneous polarization) fields.

Investigation on Conservation Environment of the Seokguram Grotto (National Treasure No. 24) (국보 제24호 석굴암의 보존환경)

  • Hong, Jung-Ki;Eom, Doo-Sung
    • 보존과학연구
    • /
    • s.24
    • /
    • pp.169-184
    • /
    • 2003
  • Yearly mean temperature and relative-humidity of the Seokguram Grotto was measured $19~23^{\circ}C$, 40~44% from May, 1998 to December,2002. The measurement has little differences comparing to the optimum guideline (temperature : $20^{\circ}\pm2^{\circ}C$, relative-humidity : $50^{\circ}\pm5%$). It is necessary to increase humidity in the Seokguram Grotto during winter because of heating and decrease the temperature during summer because of a higher temperature of outside. In addition, the diurnal range keep in $4^{\circ}C$ of temperature and in 10% of relative-humidity. Yearly mean concentration of $CO_2$(carbon dioxide) was measured538~658ppm that is higher than concentration of normal atmosphere(360 ppm). The $CO_2$ has an cumulative effect on the surface of stone cultural properties as a form of carbonic acid($H_2CO_3$) after reaction with water. HVAC (Heating, Ventilation and Air Conditioning) system should be operated to maintain ideal state for the preservation according to the optimum guideline. Also, the entrance into the Seokguram Grotto should be controlled to prevent a sudden fluctuation of humidity and temperature. Human could carry small particles like a microdust, microbe, etc., into the Seokguram Grotto and also could damage the surface by a direct touch.

  • PDF