• 제목/요약/키워드: temperature characteristic

검색결과 2,914건 처리시간 0.03초

디지털 신호처리기를 이용한 고분해능 온도측정 시스템 설계 (A Design of High Resolution Temperature Measurement System Using Digital Signal Processor)

  • 김태훈;임주현;김덕영;고한우;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권7호
    • /
    • pp.317-322
    • /
    • 2002
  • This paper presents a linear temperature/voltage relation over a temperature range(0~100$^{\circ}C$) with high-resolution, reasonably god response linearity, reliability, and overall improved performance. A notable feature of the proposed method is that the whole temperature span is divided by 16 subbands thus the variation span of measured voltage is narrowed. Therefore noise characteristic has been improved. The output voltage is amplified after the uniformed DC voltage component is eliminated by offset. We proposed circuit using median value and mean value of digital signal in order to reduce the noise effect. The proposed circuit offers linear temperature/voltage conversion over a wide dynamic range using DSP(TMS320C31) and steinhart equation.

플라즈마 용사에 의해 제조한 $Al-SiC_{p}$ 복합재료 코팅층의 고온마찰특성 (High Temperature Friction Characteristic of $Al-SiC_{p}$ Composite Coating Prepared by Plasma Thermal Spray)

  • 민준원;유승을;서동수
    • Tribology and Lubricants
    • /
    • 제19권5호
    • /
    • pp.274-279
    • /
    • 2003
  • $Al-SiC_{p}$ composite layer was prepared by plasma thermal spray on aluminum substrate. The homogeneously dispersed composite powder for thermal spray was fabricated by mechanical alloying with ball mill. The friction tests of the composite layers and commercial aluminum alloys for comparison were performed in the temperature range of 20∼$260^{\circ}C$ with the interval of $40^{\circ}C$ with steel counter-face. Friction coefficient was recorded during test sequence, and the microstructure of surface and debris was investigated by optical and scanning electron microscope. Friction coefficients of composite and aluminum alloys at room temperature were similar except pure aluminum. As the temperature increase, friction coefficient was increased rapidly in AC4C, AC2A. But friction coefficient of $Al-SiC_{p}$ composite was not increased so much up to $220^{\circ}C$. Consequently, the reinforcement of $SiC_{p}$ into aluminum matrix increased the stability of friction coefficient as well as wear resistance.

고체질소 냉각 고온초전토 동기기용 회전자의 온도특성 (Temperature Characteristic of Rotor of HTS Synchronous Machine cooled by Solid Nitrogen)

  • 조영식;홍정표;이주;심기덕;손명환;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.95-97
    • /
    • 2001
  • This paper deals with cryogen, which is used solid nitrogen to keep the operating temperature of High Temperature Superconducting (HTS) synchronous machine. To make the solid nitrogen of liquid nitrogen, liquid helium (LHe) passes into and cools the heat exchanger to its own temperature. Two types of heat exchangers are designed and manufactured to make the solid nitrogen, and temperature characteristics of those compare with each other. The rotor cooled by latent heat of solid nitrogen and it is kept under 40K during 2 hours and 30 minutes without LHe.

  • PDF

온도를 변수로 갖는 단기부하예측에서의 TAR(Threshold Autoregressive) 모델 도입 (Introduction of TAR(Threshold Autoregressive) Model for Short-Term Load Forecasting including Temperature Variable)

  • 이경훈;이윤호;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.184-186
    • /
    • 2000
  • This paper proposes the introduction of TAR(Threshold Autoregressive) model for short-term load forecasting including temperature variable. TAR model is a piecewise linear autoregressive model. In the scatter diagram of daily peak load versus daily maximum or minimum temperature, we can find out that the load-temperature relationship has a negative slope in lower regime and a positive slope in upper regime due to the heating and cooling load, respectively. In this paper, daily peak load was forecasted by applying TAR model using this load-temperature characteristic in these regimes. The results are compared with those of linear and quadratic regression models.

  • PDF

신경망을 이용한 온도장 측정법 개선 방안 (Improvements of Temperature Field Measurement Technique using Neural Network)

  • 황태규;문지섭;장태현;도덕희
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.52-55
    • /
    • 2004
  • Thermo-chromic Liquid Crystal(TLC) particles were used as temperature sensor for thermal fluid flow. $1K\times1K$ CCD color camera and Xenon Lamp(500W) were used for the visualization of a Hele-Shaw cell. The characteristic between the reflected colors from the TLC and their corresponding temperature shows strong non-linearity. A neural network known as having strong mapping capability for non-linearity is adopted to quantify the temperature field using the image of the flow. Improvements of color-to-temperature mapping was attained by using the local color luminance (Y) and hue (H) information as the inputs for the constructed neural network.

  • PDF

외기온도와 부하변화에 따른 산업용 냉각기의 인버터제어 특성 (The Characteristic of Inverter Control by Variation of Refrigeration Load and Outdoor Temperature on Industrial Cooler)

  • 백승문
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.150-155
    • /
    • 2014
  • This paper presents The performance analysis of inverter control type-industrial cooler with respect to refrigeration load and outdoor temperature. Aside from materials about simulations and foundation data regarding inverter control compressors, currently, data about commercial coolers with inverter control still lack information for performance comparison. Thus, in this paper, the experiments are done to see characteristics of condensation capacity, evaporation capacity, compressor power and COP with respect to outdoor temperature and load by using a commercial inverter control cooler model. As a result, COP difference of the inverter control cooler with respect to load is 30% at the outdoor temperature of $35^{\circ}C$, 29% at the outdoor temperature of $30^{\circ}C$, 34% at $25^{\circ}C$, respectively.

온도조건이 교면방수시스템의 인장접착특성에 미치는 영향 (The Effects of Temperature Conditions on the Tensile Adhesive Characteristic of the Bridge Decks Waterproofing Systems)

  • 이병덕;박성기;김도형;옥창권
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.293-298
    • /
    • 2003
  • In this study, tensile adhesive strength(TAS) test was carreid out for evaluated the effects of temperature conditions(-20, -10, 5, 20, 30, $40^{\circ}C$) on the tensile adhesive characteristics about six waterproofing membranes which were commercially used in bridge decks. And, failure appeariences of waterproofing systems in each temperature were investigated and observed the sawing surfaces of waterproofing systems for whether or not damaged of waterproofing membranes. TAS test results were increased when test temperature was decrease in all waterproofing membrane. The type of failure was ductile in $30^{\circ}C$ and $40^{\circ}C$, but brittle failure below $20^{\circ}C$. This results were shown that if temperature above $30^{\circ}C$ is continued for a long time, waterproofing material will be damaged by softening and a part of membranes were damaged by hot aggregate in SMA. So we will consider the type of asphalt for choice of the waterproofing membranes.

  • PDF

퍼지제어기에 의한 온도보상효과를 고려한 태양광 발전 시스템의 MPPT제어 특성 (The Characteristic of MPPT Control for Photovoltaic System by Temperature Compensation Effect using Fuzzy Controller)

  • 강병복;차인수;유권종;정명웅;송진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.238-241
    • /
    • 1995
  • In this paper, a new Maximum Power Point Tractor (MPPT) using Fuzzy Controller is proposed to improve energy convention efficiency. Temperature compensation effect means the photovoltaic voltage is change in condition irradiation, temperature and etc. Fuzzy algorithm is applied to control Boost MPPT converter by Temperature compensation effect. Temperature compensation range is $-40\sim+100^{\circ}C$.

  • PDF

Laminar Heat and Fluid Flow Characteristic with a Modified Temperature-Dependent Viscosity Model in a Rectangular Duct

  • Sohn Chang-Hyun;Chang Jae-Whan
    • Journal of Mechanical Science and Technology
    • /
    • 제20권3호
    • /
    • pp.382-390
    • /
    • 2006
  • The present study proposes a modified temperature-dependent non-Newtonian viscosity model and investigates the flow characteristics and heat transfer enhancement of the viscoelastic non-Newtonian fluid in a 2:1 rectangular duct. The combined effects of temperature dependent viscosity, buoyancy, and secondary flow caused by the second normal stress difference are considered. Calculated Nusselt numbers by the modified temperature-dependent viscosity model give good agreement with the experimental results. The heat transfer enhancement of viscoelastic fluid in a rectangular duct is highly dependent on the secondary flow caused by the magnitude of second normal stress difference.

열처리된 알루미늄 6061, 7075 합금의 온간 액압 성형 적용을 위한 온도 및 변형 속도 변화에 따른 변형 특성 연구 (A study on the deformation characteristic of heat-treated 6061,7075 aluminum alloy with changes of elevated temperature and strain rate for warm hydroforming)

  • 이혜경;문영훈;손성만;이문용;서동우;이상용
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 추계학술대회논문집
    • /
    • pp.23-26
    • /
    • 2004
  • The deformation behaviors of fully annealed or T6-treated 6061 and 7075 aluminum tubes are investigated at elevated temperature using uniaxial tensile test. Fully annealed 6061 and 7075 tube, and T6-treated 7075 tube do not show sharp local necking with an elongation of $50\%$ at tensile temperature of $300^{\circ}C$, accordingly, it is expected that warm hydroforming process can be applied. The increase of tensile temperature does not significantly affect the total elongation of T6-treated 6061 tube.

  • PDF