• Title/Summary/Keyword: temperature calibration

Search Result 516, Processing Time 0.024 seconds

Flight Model Development of the MIRIS, the Main Payload of STSAT-3

  • Han, Won-Yong;Lee, Dae-Hee;Park, Young-Sik;Jeong, Woong-Seob;Moon, Bong-Kon;Park, Kwi-Jong;Park, Sung-Joon;Pyo, Jeong-Hyun;Lee, Duk-Hang;Nam, Uk-Won;Park, Jang-Hyun;Seon, Kwang-Il;Yang, Sun-Choel;Park, Jong-Oh;Rhee, Seung-Wu;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.65.1-65.1
    • /
    • 2012
  • MIRIS (Multipurpose Infra-Red Imaging System) is the first Korean Infrared Space Telescope developed by KASI (Korea Astronomy and Space Science Institute), and is the main payload of STSAT-3 (Science and Technology Satellite-3). The FM (fight model) of MIRIS has been recently completed, and various performance tests have been made to measure system parameters such as readout noise, system gain, linearity, and dark current. Final thermal-vacumm test of the MIRIS and the vibration test of the electronics box have been performed. Band response tests showed good agreement with the initial design requirements. No significant dark difference was measured within the expected temperature variation range during observation in orbit. Using Pa-alpha band from a uniform source, the readout noise and system gain were measured by mean variance test. To obtain uniform flat image, flat fielding tests were made for each band, and the data will be compared to that obtained in orbit for calibration. The final version of MIRIS FM will be delivered in March, and it will be integrated into the satellite system for the AIT (Assembly Integration, Test) procedure. The launch of MIRIS is expected in November 2012.

  • PDF

Thermal Image Real-time estimation and Fire Alarm by using a CCD Camera (CCD 카메라를 이용한 열화상 실시간 추정과 화재경보)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.92-98
    • /
    • 2016
  • This study evaluated thermal image real-time estimation and fire alarm using by a CCD camera, which has been a seamless feature-point analysis method, according to the angle and position and image fusion by a vector coordinate point set-up of equal shape. The system has higher accuracy, fixing data value of temperature sensing and fire image of 0~255, and sensor output-value of 0~5,000. The operation time of a flame specimen within 500 m, 1000 m, and 1500 m from the test report specimen took 7 s, 26 s, and 62 s, respectively, and image creation was proven. A diagnosis of fire accident was designated to 3 steps: Caution/Alarm/Fire. Therefore, a series of process and the transmission of SNS were identified. A light bulb and fluorescent bulb were also tested for a false alarm test, but no false alarm occurred. The possibility that an unwanted alarm will be reduced was verified through a forecast of the fire progress or real-time estimation of a thermal image by the change in the image of a time-based flame and an analysis of the diffusion velocity.

Determination of Veterinary Antibiotic Residues: IV. Comparable Analytical Methods with EPA Methods 1694_A Review (시료 중 잔류 항생제 분석 방법: IV. EPA method 1694와 비교 가능한 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.670-699
    • /
    • 2016
  • In this study, 16 antibiotics were selected from among the top 30 veterinary antibiotics sold in South Korea in 2014, as well as from among the pharmaceuticals targeted by EPA method 1694, in order to review analytical methods for the detection of trace levels of antibiotics in environmental samples: surface water, soils, animal origin foods, and manures. LC-MS/MS was heavily used. In the chromatography for the detection of the selected antibiotics, the $C_{18}$ column was mostly used at the temperature of $30{\sim}40^{\circ}C$. Water and methanol/acetonitrile were commonly chosen as a nonpolar and a polar mobile phase, respectively. Gradient elution was applied to separate multiclass antibiotics. Volatile additives, such as formic acid, acetic acid, and ammonium acetate were mixed with the mobile phase to improve the ionization efficiency of analytes and the sensitivity in MS detection. Electrospray ionization (ESI) was widely used in the LC-MS/MS and positive ionization was preferred to determine the selected antibiotics. A protonated $[M+H]^+$ molecule was selected as a precursor ion, and its two transitions were analyzed, one for quantitative measurement and the other for confirmation. This study reviewed linearity of the calibration curve, recovery, repeatability, method detection limits (MDLs), and method quantification limits (MQLs) for each target compound used to validate the developed analytical methods.

Physical Properties of Transiting Planetary System TrES-3

  • Lee, Jae-Woo;Youn, Jae-Hyuck;Kim, Seung-Lee;Lee, Chung-Uk;Koo, Jae-Rim;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • We present four new transits of the planetary system TrES-3 observed between 2009 May and 2010 June. Among those, the third transit by itself indicates possible evidence for brightness disturbance, which could originate from a starspot or an overlapping double transit. A total of 107 transit times, including our measurements, were used to determine the improved ephemeris with a transit epoch of $2454185.910950\pm0.000073$ HJED (Heliocentric Julian Ephemeris Date) and an orbital period of $1.30618698\pm0.00000016$ d. We analyzed the transit light curves using the JKTEBOP code and adopting the quadratic limb-darkening law. In order to derive the physical properties of the TrES-3 system, the transit parameters are combined with the empirical relations from eclipsing binary stars and stellar evolutionary models, respectively. The stellar mass and radius obtained from a calibration using $T_{eff}$, log $\rho$ and [Fe/H] are in good agreement with those from the isochrone analysis within the uncertainties. We found that the exoplanet TrES-3b has a mass of $1.93\pm0.07\;M_{Jup}$, a radius of $1.30\pm0.04\;R_{Jup}$, a surface gravity of $28.2\pm1.1\;m\;s^{-1}$, a density of $0.82\pm0.06\;\rho_{Jup}$, and an equilibrium temperature of $1641\pm23K$.

  • PDF

A Study on CO2 Sensor Module Using NDIR Method (비분산 적외선 방식의 CO2 센서 모듈에 관한 연구)

  • Kim, Gyu-Sik;Oh, Joon-Tae;Kim, Hie-Sik;Kim, Jo-Chun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.36-40
    • /
    • 2009
  • In this paper we discuss about the practical implementation of a combined CO and CO2 dual sensor module that is adapted by NDIR (Non-Dispersive Infrared) method that measures the absorbance of gas like CO and CO2 by using gas particles' characteristics that absorb specific wave lengths of infrared ray. NDIR has a long life time, excellent measurement and precision compared to the existing contact types or chemical types of CO2 sensors. Since optical cavity technology that had been developed until now can measure CO2 only we research and develop an optimal optical cavity design and density-temperature calibration technologies that can measure CO and CO2 at the same time and is important to decide the performance of the sensor module according to well-designed wave guides of the different length.

Measurement of Radon and its Daughters Concentration in Air (공기중 라돈 및 라돈 자핵종의 농도 측정)

  • Park, Y.W.;Ha, C.W.;Ro, S.G.
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.23-29
    • /
    • 1989
  • A Lucas cell was established and calibrated by using the double layer tube standard radon source. The calibration factors were 0.031$\pm$0.002 (pCi/l)/(cph/Cell) at room temperature, and 0.029$\pm$0.001 (pCi/l)/(cph/Cell) at $50^{\circ}C$. Radon and its daughters concentrations were measured in a room air for the demonstrating purpose. The concentrations of 222 Rn, $^{218}Po,\;224\;Pb,\;and\;^{214}Bi$ were 0.87, 0.53, 0.35 and 0.26 pCi/l. The total eqilibrium factor was around 0.40 and the WL is $3.33{\times}10^{-3}$, resulting in 30 mrem/yr at this place.

  • PDF

Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Flow and Numerical Computation of the 3D Virtual Potential Distributions for Annular Flow (2상류용 전류형식 전자기유량계 이론 및 환상류에서의 3차원 가상포텐셜 분포의 수치적 계산)

  • Oh, Byung-Do;Kim, Moo-Hwan;Ahn, Yeh-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.714-725
    • /
    • 2003
  • The theory of the current-type electromagnetic flowmeter for a high temporal resolution was developed for two-phase flow measurements. To predict the output of the current-type flowmeter, the three-dimensional virtual potential distribution C and the newly introduced flow pattern coefficient f were derived and computed. The output of flowmeter depends on the liquid conductivity (sensitive to temperature) and flow configurations of the two-phase flow with the sinusoidal excitation over 100 Hz. The flow pattern coefficient was specially devised to separate the dependency on the flow configuration of the two-phase flow from that on the liquid conductivity which can be expressed with the calibration of single-phase flow. Using the finite difference method, the three-dimensional virtual potential distributions were computed for the electrode of finite size. By taking derivative of the virtual potential, the weight functions were evaluated and compared with existing analytic series solution for the point-electrode. There was a reasonable correspondence between the present and existing results. In addition, the flow pattern coefficients were evaluated for annular flows with various film thicknesses, and compared with the experimental results by the impedance spectroscopy. The numerical results agreed well with the experimental data.

Preparation Method of Indigo Standard Solution and Variation of Indigo Contents in Blue Dye Extract from Breeding Lines of Persicaria tinctoria H. Gross (인디고 분석 표준액의 제조법 및 쪽 육성계통의 인디고 함량변이)

  • Kim, Seong Ju;Ko, Jae Hyung;Park, Si Hyung;Kim, Myeong Seok;Kim, Kwan Su
    • Korean Journal of Medicinal Crop Science
    • /
    • v.21 no.3
    • /
    • pp.213-219
    • /
    • 2013
  • This study was carried out to find out the optimum method of preparation of indigo standard solution and its stability, and to investigate the indigo contents in Niram, blue dye extract, from a total of 7 indigo plants and 34 breeding lines of Persicaria tinctoria H. Gross. Proper solvent for indigo standard was dimethyl sulfoxide (DMSO), and appropriate concentration was 1 mg of indigo in 10 mL of DMSO. Absorbance value of UV/Vis Spectrophotometer at 620 nm of standard solution was changed decreasingly 12 hours after the preparation of standard solution irrespective of the storage conditions such as temperature and light. Average value of absorbance of 8-fold diluted standard solutions prepared daily during 16 days was $0.210{\pm}0.005$, indicating the powder of indigo compound was stable chemically. Calibration curve was made for quantitative analysis of indigo of 7 Niram samples, and indigo contents ranged from 0.69% to 18.76% showing relatively larger variation. Across all 34 breeding lines, the range of indigo content was from 7.9 mg to 56.4 mg per 100 g of fresh leaves, averaging 25.2 mg of indigo content and showing a 47.7% coefficient of variation.

DESIGN OF CAMERA CONTROLLER FOR HIGH RESOLUTION SPACE-BORN CAMERA SYSTEM

  • Heo, Haeng-Pal;Kong, Jong-Pil;Kim, Young-Sun;Park, Jong-Euk;Yong, Sang-Soon
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.130-133
    • /
    • 2007
  • In order to get high quality and high resolution image data from the space-borne camera system, the image chain from the sensor to the user in the ground-station need to be designed and controlled with extreme care. The behavior of the camera system needs to be controlled by ground commands to support on-orbit calibration and to adjust imaging parameters and to perform early stage on-orbit image correction, like gain and offset control, non-uniformity correction, etc. The operation status including the temperature of the sensor needs to be transferred to the ground-station. The preparation time of the camera system for imaging with specific parameters should be minimized. The camera controller needs to synchronize the operation of cameras for every channel and for every spectral band. Detail timing information of the image data needs to be provided for image data correction at ground-station. In this paper, the design of the camera controller for the AEISS on KOMPSAT-3 will be introduced. It will be described how the image chain is controlled and which imaging parameters are to be adjusted The camera controller will have software for the flexible operation of the camera by the ground-station operators and it can be reconfigured by ground commands. A simple concept of the camera operations and the design of the camera controller, not only with hardware but also with controller software are to be introduced in this paper.

  • PDF

Quantitative Determination of the Thirteen Marker Components in Banhasasim-Tang Decoction Using an Ultra-Performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 반하사심탕 물 추출물 중 13종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.1
    • /
    • pp.62-72
    • /
    • 2016
  • Banhasasim-tang is a well-known traditional Korean herbal formula and has been used clinically for the treatment of gastric disease, including acute and chronic gastritis, diarrhea and gastric ulcers in Korea. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer method was developed for the quantitative determination of the 13 marker constituents, homogentisic acid (1), 3,4-dihydroxybenzaldehyde (2), spinosin (3), liquiritin (4), baicalin (5), ginsenoside Rg1 (6), liquiritigenin (7), wogonoside (8), ginsenoside Rb1 (9), baicalein (10), glycyrrhizin (11), wogonin (12), and 6-gingerol (13) in Banhasasim-tang decoction. Separation of the compounds 1-13 was using an UPLC BEH $C_{18}$ ($100{\times}2.1mm$, $1.7{\mu}m$) column and column oven temperature was maintained at $45^{\circ}C$. The mobile phase consisted of 0.1% (v/v) formic acid in water (A) and acetonitrile (B) by gradient elution. The injection volume and flow rate were $2.0{\mu}L$ and 0.3 mL/min, respectively. Calibration curves of the compounds 1-13 were showed with $r^2$ values ${\geq}0.9908$. The limit of detection and limit of quantification values of the compounds 1-13 were 0.04-1.11 ng/mL and 0.13-3.33 ng/mL, respectively. Among the these compounds, the compounds 1-3 were not detected, while the compounds 4-13 were detected in the ranges of $3.20-107,062.98{\mu}g/g$ in Banhasasim-tang sample.