• 제목/요약/키워드: tack test

검색결과 166건 처리시간 0.023초

Flexural Vibration Analysis of a Sandwich Beam Specimen with a Partially Inserted Viscoelastic Layer

  • Park, Jin-Tack;Park, Nak-Sam
    • Journal of Mechanical Science and Technology
    • /
    • 제18권3호
    • /
    • pp.347-356
    • /
    • 2004
  • The flexural vibration characteristics of a sandwich beam system with a partially inserted viscoelastic layer were quantitatively studied using the finite element analysis in combination with the sine-sweep experiment. Asymmetric mode shapes of the flexural vibration were visualized by holographic interferometry, which agreed with those obtained by the finite element simulation. Effects of the length and the thickness of the partial viscoelastic layer on the system loss factor (η$\_$s/) and resonant frequency (f$\_$r/) were significantly large for both the symmetric and asymmetric modes of the beam system.

저온수열원이용 열펌프시스템의 전처리 및 성능분석 (Performance Analysis and Prior-Treatment of Heat Pump System with Low-Temperature Water Heat Source)

  • 박성룡;장기창;이상남;라호상;박준택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.258-263
    • /
    • 2000
  • River water is higher in temperature than the surrounding environment during the winter. It is highly suitable a heat source for heat pump system. Despite its suitability, however, it is not widely used, due to its fouling and corrosive nature in heat exchanger tubes of evaporator. It is designed prior-treatment system which come into direct contact with the river water, such as auto-seamer, ozone generator for bactericidal test and auto-cleaning system. And it is analyzed treatment effects for its operation. It is designed two-stage compression heat pump system using R-134a with heating load 35.16kW, ad analyzed its performance. As a result it is obtained 3.08 COP when mid-point pressure is 1,200kPa, and bypass ratio of flowing refreigerant to high-stage compressor is 25.1%

  • PDF

중계기점검자동복구기 Grabber에 관한 연구 (The study on Grabber of Restoration worker for Dispersion relay)

  • 전중함;박종탁;김일중
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.147-150
    • /
    • 2012
  • This study restoration worker for dispersion relay in R-Type fire alarm system. Restoration worker very good instrument for an fire system inspector. When inspector check for fire system someone need reset for fir system to normal state. This chain of action is frequent and troublesome. In this case, If we can automatic reset for fire system it's restoration worker. This paper settlement on the problem for reset fire system. Design, make grabber for restoration worker. The test offer proof possibility restoration worker.

  • PDF

조직문화와 안전풍토가 안전행동 및 사고에 미치는 영향: 도시철도 기관사를 중심으로 (The Effect of Organizational Culture and Safety Climates on Safety Behavior and Accidents: Focused on the metro train drivers)

  • 노춘호;신택현;이용만;구승환;김승태
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.91-99
    • /
    • 2014
  • This study highlights the theme of human error of train drivers, conducting empirical analysis on the relationship between organizational culture, safety climates, safety behavior, and accident. The empirical test results based on questionnaires received from 223 train drivers working at A subway firm indicated that relationship conflict and psychological reward as the elements of organizational culture variables showed a significant positive effect on CEO philosophy, communication, and boss's leadership. And only boss's leadership showed a positive influence on safety behavior, which in turn showed a significant negative relationship with accidents.

심자도 신호 획득을 위한 고속 병렬 데이터 전송 구현 (Implementation of high-speed parallel data transfer for MCG signal acquisition)

  • 이동하;유재택
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.444-447
    • /
    • 2004
  • A heart diagnosis system adopts hundreds of Superconducting Quantum Interface Device(SQUID) sensors for precision MCG(Magnetocardiogram) or MEG(Magnetoencephalogram) signal acquisitions. This system requires correct and real-time data acquisition from the sensors in a required sampling interval, i.e., 1 mili-second. This paper presents our hardware design and test results, to acquire data from 256 channel analog signal with 1-ksample/sec speed, using 12-bit 8-channel ADC devices, SPI interfaces, parallel interfaces, and 8-bit microprocessors. We chose to implement parallel data transfer between microprocessors as an effective way of achieving such data collection. Our result concludes that the data collection can be done in 250 ${\mu}sec$ time-interval.

  • PDF

도시철도 기관사조직의 안전리더십과 관련요인 간의 인과관계 구조분석 (A Structural Analysis of Causality between Safety Leadership and Related Factors in the Metro Driver Organization)

  • 강근식;신택현
    • 대한안전경영과학회지
    • /
    • 제19권4호
    • /
    • pp.105-113
    • /
    • 2017
  • This study highlights the theme of safety leadership in railway organization, conducting empirical analysis on the relationship between safety climates, safety leadership, safety behavior, and accident. The empirical test results based on questionnaires received from 223 train drivers working at A subway firm indicated that relationship between CEO's safety philosophy, and safety communication showed a significant positive effect on boss's safety leadership. And boss's safety leadership showed a positive influence on observation belonging to safety behavior, which in turn showed a significant negative relationship with mistake. However, mistake, observation and violation were shown that there are no relationship with accidents.

ESG경영과 안전경영 그리고 경영성과의 구조적 관계 : 지역 공항을 중심으로 (Structural Relationship between ESG Management and Safety Management and Business Performance : Focused on Regional Airport)

  • 조영진;성행남;권진택
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제32권4호
    • /
    • pp.51-67
    • /
    • 2023
  • Purpose While research on ESG management in airlines is ongoing, research on airports, especially regional ones, remains insufficient. This study's point of departure is the inquiry into how the local airport industry is addressing global environmental shifts and engaging in ESG management activities. Design/methodology/approach Based on previous studies, the relationship between ESG(Environmental, Social, Governance) management, safety management, reputation, and management performance was analyzed. We analyzed 578 questionnaires through structural equation modeling using AMOS 21.0 to test our hypotheses. Findings First, environmental, social, governance, and safety management have a positive effect on both reputation and business performance. Second, reputation has affected business performance. Third, reputation was affected in the order of governance management, safety management, environmental management, and social management.

일체형 주상용 몰드 변압기의 온도분포 및 특성 비교 (Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding)

  • 조한구;이운용;강택수;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

FEM을 이용한 타이어의 벨트각도에 따른 PRAT 및 코너링 특성 연구 (A Study on Characteristics of PRAT and Cornering due to the Belt Angle of Tire by the FEM)

  • 성기득;김성래;김기현;김선주;조춘택
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.104-112
    • /
    • 2006
  • The influence of tire belt angle on the Plysteer Residual Aligning Torque(PRAT) and the cornering stiffness by the FEM has been studied. The PRAT is a performance factor of the tire about vehicle pull, and the cornering stiffness has relation to vehicle steering response of outdoor test. To validate FE model for analysis, simulation data for both the static stiffness(vertical, lateral) and the PRAT have been compared with the experimental data. In addition to the characteristics of the PRAT and the cornering stiffness due to the tire belt angle, rolling and cornering contact characteristics have been studied. The tendency of the PRAT and the cornering stiffness due to the belt angle can be used as a guide line for the tire design in relation to vehicle pull and vehicle steering response.

충남지역(忠南地域) 유우유방염(乳牛乳房炎)의 감염율(感染率) 및 원인균(原因菌)에 관한 연구(硏究) (Studies of Infection Rate and Causative Agents of Bovine Mastitis in Chungnam Area)

  • 김홍수;홍순국;소경택;한홍률
    • 대한수의학회지
    • /
    • 제14권1호
    • /
    • pp.91-97
    • /
    • 1974
  • A total of 820 dairy cattle were examined formastitis by California mastitis test method and 181 dairy cattle were examined bacteriologically according to the method of Connecticut mastitis control program. The results obtained were as followings: 1. Milk samples from 1.231(38.1%) of 3,225 quarters and 568(69.3%) of 820 dairy cattle were positive for mastitis by California mastitis test method. 2. Among 181 cattle examined bacteriologically by the method of Connecticut mastitis control program 159(22.9%) quarters of 102(56.4%) cattle were infected. Clinical mastitis was found in 5 cattle. 3. Important causative organisms were found to de Staphylococcus aureus(44.8%), Streptococcus agalactiae(21.5%), and non-str, agalactiae Streptococcus(26.4%). Corynebacterium ssp., Pseudomonas spp., Coliforms and Yeasts were also occasionally found to be causative organisms. 4. Strains of Staphylococcus aureus isolated from bovine udders were tested for sensitivity to antibiotics. The rates of resistant strain were 13.7%, 11.8%, 8.8%, 5.9%, 100%, 4.9% and 4.9% for penicillin G, streptomycin, terramycin, erythromycin, chloramphenicol, ampicillin and kanamycin, respectively.

  • PDF