• Title/Summary/Keyword: system rig test

검색결과 193건 처리시간 0.028초

Tilting Test Rig를 이용한 엔진 윤활 시스템 안정성 평가 (Safety Estimation of Engine Lubrication System using Tilting Test Rig)

  • 윤정의;전문수
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.1-6
    • /
    • 2002
  • Engine lubrication system is generally affected by vehicle driving conditions, which are composed of acceleration, braking deceleration and accelerating during cornering. The major reason is due to the oil pan system in which oil is directly influenced by inertia farce caused by vehicle driving conditions. Therefore, to confirm safety of engine lubrication system inertia farce effects are also considered in the developing state. For the purpose, we have carried the engine tilting tests using ourselves made test rig. Verifying the test results we also measured the inertia effects on the engine lubrication system using the circular tuning and slalom test with vehicle. Through the comparison study between two kinds of results we obtained that the engine tilting test rig was very useful to confirm the safety evaluation of engine lubrication system.

승용차의 single wheel에 대한 antilocking-brake-system의 구성 및 test rig을 이용한 제동실험 (Set up of an antilocking-brake-system for the single wheel of passenger cars and brake test using a test rig)

  • 홍예선;지태수;고창복
    • 오토저널
    • /
    • 제12권5호
    • /
    • pp.36-45
    • /
    • 1990
  • In this study an antilocking-brake-system was set up for the single wheel of passenger cars. The control algorithm for the system was programmed by C-language and executed by a 16bit personal computer, which took the role of an electronic control unit. The performance of the antilocking-brake-system was tested using a test rig, which was specially designed and built up for the simulation of braking on the slippery road. The test results were satisfactory. Although the simulation method of the friction characteristics between the tire and the contact surface on the test rig appeared not to be absolutely suitable, the test rig allowed the basic investigation of the influence of the antilocking brake control on the wheel slip.

  • PDF

테일팬 성능시험장치의 운용과 진동특성 (The Operation and Vibration Characteristics of Tail-Fan Performance Test System)

  • 송근웅;김준호;강희정;이욱;심정욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.508-512
    • /
    • 2004
  • This paper described operation and vibration characteristics of 'Tail-Fan' performance test system. KARI(Korea Aerospace Research Institute) developed 'Tail-Fan' system as a kind of helicopter anti-torque system(ATS) and designed ATS performance test-rig for Tail-Fan system performance test. Test-rig consists of driving parts, supporting parts and rotating parts. For Tail-Fan system performance tests, firstly, test-rig operation tests were carried out for verification of design specifications. Secondly, natural frequencies of fan blade and test-rig were measured respectively. Lastly, to find the operation rotating speed for performance tests, vibration tests using accelerometers on tail gear box(TGB) were carried out. Through the fanplot and vibration test results, Tail-Fan performance test conditions to avoid a resonance were found and performance tests were well done safely.

  • PDF

소형 항공기 착륙장치 낙하시험 장비 설계 및 제작 (Design & Fabrication for Small Aircraft Landing Gear Drop Test Rig System)

  • 한재도;이영신;안오성
    • 한국항공우주학회지
    • /
    • 제36권11호
    • /
    • pp.1121-1125
    • /
    • 2008
  • 본 논문에서는 소형 항공기 낙하시험을 위한 낙하 시험 장비 개발에 관한 연구를 수행하였다. 시험장비는 유압 액츄에이터를 이용하여 자동으로 시험체를 상승시키고 또 다른 유압 액츄에이터를 이용 자동으로 낙하시키며, 낙하시험시 안전성 확보를 위한 2중의 안전 장치를 적용하였다. 장비의 정적 안정성 확보를 위해 장비의 구조해석을 수행하였으며, 해석된 결과를 반영하여 시험 장비를 설계 제작을 하였다. 제작된 장비의 낙하 신뢰도 확보를 위해 마찰력 측정 시험 및 낙하속도 측정 시험을 실시하여 장비의 적합성을 확인 하였다.

엔진 흡기시스템 개발 시 사용하는 텀블유동 시험장치의 고찰 (A Study on the Tumble Flow Test Rig Used to Developing Engine Induction System)

  • 윤정의;김명환;남현식;민선기;심대곤;박병완
    • 한국자동차공학회논문집
    • /
    • 제14권6호
    • /
    • pp.184-189
    • /
    • 2006
  • Tumble flow test rig has been used as the useful tool in the developing intake system because major flow pattern induced by intake port of DOHC engine is tumble. Angular momentum of in-cylinder tumble flow can not be directly measured by impulse torque meter in the test rig like that of in-cylinder swirl flow due to rotational axis of the flow. Therefore the adaptor to transform tumble to swirl flow must be adapted in the test rig. In this study, using the commercial CFD code STAR-CD, we studied the effects on measured results due to the variation of the major design variables in the adaptor, tube length(L), tube diameter(D) and cylinder height(H). The effect of the attached angle($\theta$) of the test head to the adaptor also was simulated.

압축공기 발사기에 단선 와이어 유도방식을 적용한 1/60축척 터널주행 열차모형 시험기 개발에 대한 연구 (Development of 1/60th Scale Moving Model Rig Using the Compressed Air Launcher and One-Wire Guidance System of Train Model)

  • 김동현;오일근
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.634-644
    • /
    • 2001
  • The test facility of a 1/60-scale model for train-tunnel systems has been recently developed to investigate the effects of tunnel portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating towards the surroundings from the tunnel exit. The present test rig has been advanced from a 1/70-scale facility at NLR in Netherlands. The NLR test rig has the two-wise guidance system that needs two ears attached on the external surface of a model train nose. Therefore, their train models have irregular nose shapes. The main characteristics of the present facility are that the train model is guided by only one wire from the compressed air launcher to the absorber parts of test facility and the wire guidance hole is located at the axial center of a train model. In the present test rig, after a train model is launched, the air jet from the launcher does not enter the tunnel model. Experimental results were compared with numerical predictions to prove the performance of the test facility.

테일홴 성능시험장치의 운용과 진동특성 (The Operation and Vibration Characteristics of Tail-fan Performance Test System)

  • 송근웅;김준호;강희정;이욱;심정욱
    • 한국소음진동공학회논문집
    • /
    • 제15권4호
    • /
    • pp.421-428
    • /
    • 2005
  • This paper described operation and vibration characteristics of a 'tail-fan' anti-torque performance test system. KARI (Korea Aerospace Research Institute) developed a 'tail-fan' anti-torque system of a helicopter and a performance test-rig to test the performance of the tail-fan. The performance test-rig consists of driving, supporting and rotating parts. In the process of the performance test, firstly, operation test of the test-rig were carried out to verify design specifications. Secondly, natural frequencies of fan blade and test-rig were measured respectively. Lastly, to find the operation rotating speed for the performance test, vibration test were carried out using accelerometers on tail gear box. The performance test conditions of the tail-fan to avoid a resonance were found from the fan-plot and vibration test results. The tail-fan performance tests were well done safely.

풍력발전기용 증속기 시험 장비의 토크 인가 장치 설계 (Design of a Torque Application Device in Test Rig for a Wind Turbine Gearbox)

  • 김정길;박영준;이근호;남용윤;오주영
    • 대한기계학회논문집A
    • /
    • 제39권5호
    • /
    • pp.507-515
    • /
    • 2015
  • 본 연구는 5.5MW 증속기용 기계식 동력순환 시험 장비의 핵심 기능을 하는 토크 인가 장치의 개발 및 검증에 관한 것으로, 설계 및 해석이 수행되었다. 또한, 시험 장비의 각 부품에 대하여 회전각을 측정하여 비틀림 강성을 확인하였다. 시험체를 제외한 시험 장비에 토크를 인가하여 각 부품의 회전각을 측정한 결과 시험 장비의 비틀림 강성은 정방향에서 231.13 kNm/rad으로 나타났으며, 증속기 1대의 비틀림 강성이 1,064,400 kNm/rad보다 큰 경우 정격 토크를 인가할 수 있다. 따라서 시험 장비의 회전각 한계로 인하여 시험체 증속기의 비틀림 강성에 따라 정격 토크 인가 여부가 결정된다.

능동 현가시스템의 성능평가를 위한 유압식 시험기의 설계 및 제어에 관한 연구 (A study on design and control of hydraulic test rig for performance evaluation of active suspension system)

  • 손영준;이광희;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1445-1449
    • /
    • 1996
  • To evaluate of active suspension, it is necessary for special equipment - so called Test Rig which can perfectly realize the road condition and the impact from the road. And most of the test rig systems controlling force accurately and rapidly consist of electro-hydraulic servo mechanism, and they need robust controller which can endure outer road change. But in the case of PID controller, we should choose its best gains by trial and error method, and once its gains are fixed, they cannot get changed, so we should reset PID controller gains respectively when the road is changed. Therefore based on the load pressure feedback compensation method, our aim at constructing electro-hydraulic test rig is not affected by various road disturbance.

  • PDF