• Title/Summary/Keyword: symmetry

Search Result 2,031, Processing Time 0.027 seconds

A Study of Root Canals Morphology in Primary Molars using Computerized Tomography (CT를 이용한 유구치 근관 형태에 관한 평가)

  • Sim, Dohee;Mah, Yonjoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.4
    • /
    • pp.400-408
    • /
    • 2019
  • The purpose of this study is to identify the most common canal type in primary molars and the correlation between their roots and canals. A comprehensive understanding of root canal morphology will lead to more successful root canal treatment. Computed Tomography (CT) images from 114 children (81 boys, 33 girls) aged 3 - 7 years were obtained. The locations and numbers of roots and canals were evaluated, and the relationship between root and canal parameters was determined. The most commonly observed canal morphology in primary maxillary molars were mesio-buccal, disto-buccal and palatal canal. Primary mandibular molars most frequently contain mesio-buccal, mesio-lingual, disto-buccal and distolingual canal. All the roots of the primary maxillary molars except for the mesio-buccal root, each had 1 canal while there were 2 canals observed in each root of primary mandibular molars. Without exception, all mesial roots in primary mandibular 2nd molars had 2 canals. In case when either the palatal root in a primary maxillary molar or the distal root in a primary mandibular molar was separated into 2 roots, each root seemed to have its own canal. Even though the disto-buccal and palatal roots were fused into 1 root in primary maxillary molars, this fused root had tendency to have 2 separate canals. Primary mandibular molars showed similar canal morphologies between left and right molars in the same patient, while the primary maxillary molars did not.

Ray Effect Analysis Using the Discrete Elements Method in X-Y Geometry (2차원 직각좌표계에서 DEM을 이용한 ray effect의 해석)

  • Choi, Ho-Sin;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.1
    • /
    • pp.43-56
    • /
    • 1992
  • As one of the methods to ameliorate the ray effects which are the nature of anomalous computational effects due to the discretization of the angular variable in discrete ordinates approximations, a computational program, named TWODET (TWO dimensional Discrete Element Transport), has developed in 2 dimensional cartesian coordinates system using the discrete elements method, in which the discrete angle quadratures are steered by the spatially dependent angular fluxes. The results of the TWODET calculation with K-2, L-3 discrete angular quadratures, in the problem of a centrally located, isotropically emitting flat source in an absorbing square, are shown to be more accurate than that of the DOT 4.3 calculation with S-10 full symmetry angular quadratures, in remedy of the ray effect at the edge flux distributions of the square. But the computing time of the TWODET is about 4 times more than that of the DOT 4.3. In the problem of vacuum boundaries just outside of the source region in an absorbing square, the results of the TWODET calculation are shown severely anomalous ray effects, due to the sudden discontinuity between the source and the vacuum, like as the results of the DOT 4.3 calculation. In the probelm of an external source in an absorbing square in which a highly absorbing medium is added, the results of the TWODET calculation with K-3, L-4 show a good ones like as, somewhat more than, that of the DOT 4.3 calculation with S-10.

  • PDF

Organotitanium Chemistry (IV). The Molecular and Electronic Structure of $TiCl(OC_6H_5)_3{\cdot}C_6H_5OH\;and\;Ti(OC_6H_5)_4{\cdot}C_6H_5OH$ (유기티탄 화학 (제4보). $TiCl(OC_6H_5)_3{\cdot}C_6H_5OH\;및\;Ti(OC_6H_5)_4{\cdot}C_6H_5OH$의 분자 및 전자구조)

  • Lee Hoosung;Uh Young Sun;Sohn Youn Soo
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.2
    • /
    • pp.92-97
    • /
    • 1975
  • The molecular and electronic structures of $TiCl(OC_6H_5)_3{\cdot}C_6H_5OH\;and\;Ti(OC_6H_5)_4{\cdot}C_6H_5OH$ have been studied by employing cryoscopic and electronic spectroscopic methods. The cryoscopic data have shown that the dimeric tetraphenoxytitanium(Ⅳ) phenolate in solid undergoes complete dissociation into monomer in solution and also the chlorocomplex starts dissociation around the concentration of 8 m mole/l. Therefore, these two Ti-complexes are pentacoordinated in dilute solution and the local symmetry of the titanium ion in these complexes seems to be trigonalbipyramid. The electronic spectra of $TiCl(OC_6H_5)_3{\cdot}C_6H_5OH$ and $Ti(OC_6H_5)_4{\cdot}C_6H_5OH$ each show two band, systems, one vibration-structural band characteristic of the aromatic ring in the near UV and another visible band at 26.8 kK, 29.6 kK, respectively, which are assigned as a ligand to metal charge transfer band corresponding to $^1A_1''{\to}^1E'\;or\;^1E''$ transition.

  • PDF

The Effect of Ligand's Spin-Orbit Coupling and the Intermixing of │3d 〉 and │4p 〉 Cu Atomic Orbitals on Zero-Field Splitting in the Tetragonally Distorted Tetrahedral $CuCl_4^{2-}\;Complex^\ast$ (Cu 3d 와 4p 궤도함수의 혼성과 리간드의 Spin-Orbit Coupling 이 Tetragonally 일그러진 $CuCl_4^{2-}$ 착물의 Zero-Field Splitting에 미치는 영향)

  • Lee, Wang No;Choe, U Seong;Baek, U Hyeon;Kim, Dong Hui;Choe, Chang Jin;Lee, Gi Gye
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.37-43
    • /
    • 1990
  • An effect of the spin-orbit coupling interaction of ligand orbitals and the intermixing │3d 〉and│4p > transition metal atomic orbitals on the ground state for a 3$d^9$ system in a strong crystal field of tetragonally distorted tetrahedral symmetry that belongs to the $D_{2d}$ point group has been investigated in this work, applying the degenerate perturbation theory. An LCAO-MO analysis in terms of the known energies of the d-d transitions for the tetragonally distorted $CuCl_4^{2-}$ ion in a single crystal of$Cs_2CuCl_4$shows that the covalent mixing of Cu 3d and ligand Cl 3p orbitals decreases dramatically with increasing Cu 4p contribution. The extent of effect on the energy level splitting for the ground state by the spin-orbit coupling interaction of ligand orbitals decreases significantly in orderTEX>$\Gamma_7(E)\;\to\;\Gamma_6(E)\; >\;\Gamma_7(B_2)\;\to\;\Gamma_6(E)\; >\;\Gamma_7(B_2)\;\to\;\Gamma_7(E)$.

  • PDF

Soft x-ray Synchrotron Radiation Spectroscopy Study of Molecule-based Nano Bioparticles Containing Fe (철원소를 함유한 분자기반 생체물질 나노입자들의 연 x선 방사광 분광 연구)

  • Lee, Eun-Sook;Kim, D.H.;Hwang, Ji-Hoon;Lee, Ki-Ho;Kang, J.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.125-129
    • /
    • 2012
  • By employing soft x-ray absorption spectroscopy (XAS) and soft x-ray magnetic circular dichroism (XMCD), the electronic structures of molecule-based nano bioparticles, such as Helicobacter pylori ferritin (H. pylori ferritin), Heme, $NaM[Fe(CN)_6]{\cdot}H_2O$-type Prussian Blue (M=Co, Ni) analogue, have been investigated. The measured Fe 2p XAS spectra reveal that Fe ions are trivalent ($Fe^{3+}$) in H. pylori ferritins, while they are in the $Fe^{2+}-Fe^{3+}$ mixed-valent states in $NaM[Fe(CN)_6]{\cdot}H_2O$ Prussian Blue analogues (M=Co, Ni). According to the Fe 2p XMCD spectrum of high-state H. pylori ferritin, all the $Fe^{3+}$ ions have the same local symmetry and their magnetic moments are aligned in the same direction. It is also found that the Fe 3d orbitals in $NaM[Fe(CN)_6]{\cdot}H_2O$ have a strong covalent bonding to $(CN)^-$ ligands, but with a very weak bonding to the 2p orbitals of O ligands.

Half-metallicity and Magnetism of Co2ZrSi/ZnTe(001) Interface: A First-principles Study (Co2ZrSi/ZnTe(001)계면의 자성과 반쪽금속성에 대한 제일원리 연구)

  • Jin, Y.J.;Lee, J.I.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.147-151
    • /
    • 2007
  • We have investigated the half-metallicity and magnetism for the Heusler ferromagnet $Co_2$ZrSi interfaced with semiconductor ZnTe along the (001) plane by using the full-potential linearized augmented plane wave (FLAPW) method. We considered low types of possible interfaces: ZrSi/Zn, ZrSi/Te, Co/Zn, and Co/Te, respectively. From the calculated density of states, it was found that the half-metallicity was lost at all the interfaces, however for the Co/Te system the value of minority spin density of states was close to zero at the Fermi level. These facts are due to the interface states, appeared in the minority spin gap in bulk $Co_2$ZrSi, caused by the changes of the coordination and symmetry and the hybridizations between the interface atoms. At the Co/Te interface, the magnetic moments of Co atoms are 0.68 and $0.78{\mu}_B$ for the "bridge" and "antibridge" sites, respectively, which are much reduced with respect to that ($1.15{\mu}_B$) of the bulk $Co_2$ZrSi. In the case of Co/Zn, Co atoms at the "bridge" and "antibridge" sites have magnetic moments of 1.16 and $0.93{\mu}_B$, respectively, which are almost same or slightly decreased compared to that of the bulk $Co_2$ZrSi. On the other hand, for the ZrSi/Zn and ZrSi/Te systems, the magnetic moments of Co atoms at the sub-interface layers are in the range of $1.13{\sim}1.30\;{\mu}_B$, which are almost same or slightly increased than that of the bulk $Co_2$ZrSi.

Paraboloidal 2-mirror Holosymmetric System with Unit Maginification for Soft X-ray Projection Lithography (연X-선 투사 리소그라피를 위한 등배율 포물면 2-반사경 Holosymmetric System)

  • 조영민;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.188-200
    • /
    • 1995
  • A design of unit magnification 2-mirror system with high resolution is presented. It is for soft X-ray(wavelength of 13 nm) projection imaging and suitable for preparation of high density semiconductor chip. In general, a holosymmetric system with unit magnification has the advantage that both coma and distortion are completely eliminated. In our holosymmetric 2-mirror system, spherical aberration is addtionally removed by using two identical paraboloidal mirror surfaces and field curvature aberration is also corrected by balancing Petzval sum and astigmatism which depends on the distance between two mirrors, so that the system is a aplanatic flat-field paraboloidal 2-mirror holosymmetric system. This 2-mirror system is small in size, and has a simple configuration with rotational symmetry about optical axis, and has also small central obscuration. Residual finite aberrations, spot diagrams, and diffraction-based MTF's are analyzed for the check of performances as soft X-ray lithography projection system. As a result, the image sizes for the resolutions of$0.25\mum$and $0.18\mum$are 4.0 mm, 2.5 mm respectively, and depths of focus for those are $2.5\mum$, $2.4\mum$respectively. This system should be useful in the fabrication of 256 Mega DRAM or 1 Giga DRAM. DRAM.

  • PDF

Runoff Analysis for Urban Unit Subbasin Based on its Shape (유역형상을 고려한 도시 단위 소유역의 유출 해석)

  • Hur, Sung-Chul;Park, Sang-Sik;Lee, Jong-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.5
    • /
    • pp.491-501
    • /
    • 2008
  • In order to describe runoff characteristics of urban drainage area, outflow from subbasins divided by considering topography and flow path, is analyzed through stormwater system. In doing so, concentration time and time-area curve change significantly according to basin shape, and runoff characteristics are changed greatly by these attributes. Therefore, in this development study of FFC2Q model by MLTM, we aim to improve the accuracy in analyzing runoff by adding a module that considers basin shape, giving it an advantage over popular urban hydrology models, such as SWMM and ILLUDAS, that can not account for geometric shape of a basin due to their assumptions of unit subbasin as having a simple rectangular form. For subbasin shapes, symmetry types (rectangular, ellipse, lozenge), divergent types (triangle, trapezoid), and convergent types (inverted triangle, inverted trapezoid) have been analyzed in application of time-area curve for surface runoff analysis. As a result, we found that runoff characteristic can be quite different depending on basin shape. For example, when Gunja basin was represented by lozenge shape, the best results for peak flow discharge and overall shape of runoff hydrograph were achieved in comparison to observed data. Additionally, in case of considering subbasin shape, the number of division of drainage basin did not affect peak flow magnitude and gave stable results close to observed data. However, in case of representing the shape of subbasins by traditional rectangular approximation, the division number had sensitive effects on the analysis results.

Fabrication of Stack-Structured Gas Sensor of LaCrxCo1-xO3/Li1.3Al0.3Ti1.7(PO4)3 and Its NOx Sensing Properties (LaCrxCo1-xO3/Li1.3Al0.3Ti1.7(PO4)3의 적층구조를 가지는 가스센서 제조와 그의 NOx 검지특성)

  • Lee, Young-Sung;Shimizu, Y.;Song, Jeong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.25 no.8
    • /
    • pp.423-428
    • /
    • 2015
  • Impedancemetric $NO_x$ (NO and $NO_2$) gas sensors were designed with a stacked-layer structure and fabricated using $LaCr_xCo_{1-x}O_3$ (x = 0, 0.2, 0.5, 0.8 and 1) as the receptor material and $Li_{1.3}Al_{0.3}Ti_{1.7}(PO_4)_3$ plates as the solid-electrolyte transducer material. The $LaCr_xCo_{1-x}O_3$ layers were prepared with a polymeric precursor method that used ethylene glycol as the solvent, acetyl acetone as the chelating agent, and polyvinylpyrrolidone as the polymer additive. The effects of the Co concentration on the structural, morphological, and $NO_x$ sensing properties of the $LaCr_xCo_{1-x}O_3$ powders were investigated with powder X-ray diffraction, field emission scanning electron microscopy, and its response to 20~250 ppm of $NO_x$ at $400^{\circ}C$ (for 1 kHz and 0.5 V), respectively. When the as-prepared precursors were calcined at $700^{\circ}C$, only a single phase was detected, which corresponded to a perovskite-type structure. The XRD results showed that as the Co concentration of the $LaCr_xCo_{1-x}O_3$powders increased, the crystal structure was transformed from an orthorhombic phase to a rhombohedral phase. Moreover, the $LaCr_xCo_{1-x}O_3$ powders with $0{\leq}x<0.8$ had a rhombohedral symmetry. The size of the particles in the $LaCr_xCo_{1-x}O_3$powders increased from 0.1 to $0.5{\mu}m$ as the Co concentration increased. The sensing performance of the stack-structured $LaCr_xCo_{1-x}O_3/Li_{1.3}Al_{0.3}Ti_{1.7}(PO_4)_3$ sensors was found to divide the impedance component between the resistance and capacitance. The response of these sensors to NO gas was more sensitive than that to $NO_2$ gas. Compared to other impedancemetric sensors, the $LaCr_{0.8}Co_{0.2}O_3/Li_{1.3}Al_{0.3}Ti_{1.7}(PO_4)_3$ sensor exhibited good reversibility and reliable sensingresponse properties for $NO_x$ gases.

A Tracking Scheme using Correlation Value at Advanced Offset Range in Galileo BOC(1,1) Signal (Galileo BOC(1,1)에서 이른 상관시간 옵셋 영역의 상관 값을 이용한 추적기법)

  • Yoo, Seung-Soo;Kim, Sang-Hun;Yoon, Seok-Ho;Song, Iick-Ho;Kim, Jun-Tae;Kim, Sun-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.1C
    • /
    • pp.86-93
    • /
    • 2008
  • The Galileo system, a global navigation satellite system(GNSS) developed by E.U., uses the direct sequence/spread spectrum(DS/SS) modulation. A DS/SS-based system performs a fine synchronization between the received and locally generated spreading signals, via attacking process. In the absence of multipath signals, using the symmetric characteristic of the correlation function, the delay lock loop with the early minus late discriminator(EL-DLL) offers the best performance in tracking. However, in the presence of multipath signals, the symmetry of the correlation function could be lost, causing a tracking bias. In this paper, we observe that the correlation values in the advanced offset range remain almost unchanged, due to the multipath signals being received later than a line-of-sight signal. Based on this observation, we propose a novel tracking scheme for a Galileo BOC(1,1) system.