• Title/Summary/Keyword: surface washing

Search Result 392, Processing Time 0.042 seconds

Removal Efficiency of Microorganism and Pesticide Residues by a Using Surface Washing System on Yuja (Citrus junos Sieb ex Tanaka) (표면 세척 시스템에 의한 유자의 미생물 및 잔류농약의 제거효과)

  • Sung, Jung-Min;Kwon, Ki-Hyun;Kim, Jong-Hoon;Jeong, Jin-Woong
    • Food Science and Preservation
    • /
    • v.18 no.5
    • /
    • pp.627-635
    • /
    • 2011
  • This study was conducted to assess the effects of the removal of pesticide residues and microorganisms from yuja (Citrus junos Sieb ex Tanaka) using a surface-washing system, under the following washing conditions: 0.11, 0.42, and 0.73 m/s spray rotation speeds; 0.6, 0.9, and 1.2 MPa water pressure and 0.046, 0.092, and 0.138 m/s conveying speeds. Tap-water treatment was used as the control. The washing efficiency when using squid ink was highly correlated with the conveying speed and the spray rotation speed. In addition, the highest washing efficiency was achieved when the water pressure was 0.9 MPa. The microorganisms were reduced to 0.40 log CFU/g for the tap-water treatment, and all the treatments, except those at the conveying speed of 0.138 m/s and the spray rotation speed of 0.11 rpm (6.07 log CFU/g), produced higher removal efficiencies compared with the tap-water treatment. Reductions of 2.20 and 2.05 log CFU/g were achieved at the spray rotation speeds of 0.42 and 0.73, respectively. The largest reductions were observed when the conveying speed was 0.046 m/s. Higher pesticide residue removal efficiency values were obtained at slower conveying speeds and higher spray rotation speeds. Higher than 50% removal efficiency was achieved when the spray rotation speed was 0.046 m/s for spirodichlofen, deltamethrin, benomyl, thiophanate-methyl, and acequinocyl. Especially, the removal efficiency for benomyl and thiophanate-methyl was more than 90%. It can thus be concluded that the pesticide residues in yuja can be effectively reduced by washing the latter with a less-than-0.092-m/s conveying speed and a higher-than-0.42-m/s spray rotation speed.

Evaluation of a Rapid Sand Filter with Surface Wash and Backwash Conditions (정수장 급속여과지 역세척 수위변화와 시간에 따른 세척 효율 평가)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.652-656
    • /
    • 2004
  • Both surface wash and backwash are considered as one of the most important methods that can improve the filtration efficiency in the existing water treatment plant. This study has mainly focused on the improvement of filtering efficiency by controlling surface wash and backwash time, and water level before backwash (when drained up to the trough, when drained up to 10 cm above filter bed, and when drained below 10 cm filter bed). Filtration efficiency was shown a little bit of differences depending on the operating conditions like surface wash injection pressure, the distance control between filter bed and the facility, and the types of surface wash. When the water level before backwash was reached up to 10 cm below filter bed after draining, however, the filtration velocity and the turbidity removal efficiency in the filter bed was improved. When the surface wash followed by backwash is longer, it showed a similar result. Because the proper adjustment of surface washing time makes filtration efficiency higher, therefore, it is necessary to set up the backwash time moderately.

Effects of Pre-treatment Method on the Surface Microbes of Radish (Raphanus sativus L.) leaves (전처리 방법이 무청의 표면 미생물 변화에 미치는 영향)

  • Ku, Kyung-Hyung;Lee, Kyung-A;Kim, Young-Lim;Lee, Myung-Gi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.5
    • /
    • pp.649-654
    • /
    • 2006
  • It was investigated the effects of pre-treatment method on the microbes on the surface of radish (Raphanus sativus L.) leaves. Independent variables put in water washing ($X_1$), microwave treatment ($X_2$) and steam treatment ($X_3$) using central composite design and response surface analysis. It was not detected in the pathogenic microbes, Samonella spp., Camphylobacter spp., Vibrio spp., Shigella spp., Staphyloccocus spp., on the surface of collected radish leaves without pre-treatment. But general microbes showed $3.90{\times}10^5{\sim}1.20{\times}10^7CFU/g$ of total microbes, $1.10{\times}10^2{\sim}2.00{\times}10^5CFU/g$ of E. coli, $2.40{\times}10^3{\sim}3.55{\times}10^6CFU/g$ of yeast/mold on the surface of various radish leaves and lactic acid bacteria was detected or not according to collected samples. The best method of pre-treatment was steam treatment on the microbe reduction effect of samples surface. Also, the multiplex regression coefficients analysis was calculated three independent variables ($X_1,\;X_2,\;X_3$) and dependent variables (total microbes, lactic acid bacteria and yeast/molds). It showed high correlation $R^2$, 0.89, 0.87, 0.85, respectively. For effective reduction of surface microbes, the best method was water washing with microwave or steam treatment at the same time.

Effect of Surface Washing Treatment on Quality of Fresh Ginseng during Storage (표면세척이 수삼의 저장 중 품질에 미치는 영향)

  • Kim, Eun-Jeong;Kim, Gun-Hee;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.380-385
    • /
    • 2007
  • This study was basic research to improve the existing method far distributing just harvested and sail-clad fresh ginseng. The quality of surface-washed fresh ginseng was compared to that of muddy fresh ginseng during storage at 0, 5, 10, and $20^{\circ}C$. After 45 days of storage, there was no difference in weight loss between the washed ginseng and the control at $0^{\circ}C$, but the loss was 46% and 37% lower in the washed than the control at $5^{\circ}C$ and $10^{\circ}C$, respectively. The ginseng stored at $20^{\circ}C$ after washing had less deterioration than the control stored at $10^{\circ}C$ for the same period. The sensory characteristics of the washed ginseng showed better quality scores ranging from 6.8 to 8.2, while the control ranged from 5.7 to 6.9 after 45 days of storage at $10^{\circ}C$. The washed ginseng had less viable cells, mold and yeast, and coliforms at 0.87, 1.55, and 0.95 log units, respectively, compared to the control, and this trend was maintained in the washed ginseng throughout storage.

Improvement of Hot Dip Galvanizing Process by Additive to Flux Solution (플럭스액의 첨가제에 의한 용융아연도금 공정개선)

  • Moon, Kyung-Man;Jeong, Jae-Hyun;Park, Jun-Mu;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.6
    • /
    • pp.513-520
    • /
    • 2016
  • Many surface protection methods have been developed to apply to constructional steels which have been used under severe corrosive environments. One of these methods, hot dip galvanizing is being widely used to the numerous constructional steels such as a guard rail of high way, various types of structural steel for manufacturing ship and for some other industrial fields etc.. Recently, the cost of zinc is getting higher and higher, thus, it is considered that improvement of hot dip galvanizing process to reduce the cost of production should be developed possibly. In this study, additives such as acid cleaning solution, $NH_4OH$, $Al(OH)_3$ and $H_2O_2$ were added to flux solution, and omission of water washing treatment after acid cleaning was investigated with some types of flux solutions added with some additives mentioned above. The decrement of pH by adding the acid cleaning solution could be controlled due to neutralization reaction with addition of $NH_4OH$. The flux solution added with both $NH_4OH$ and $Al(OH)_3$ exhibited nearly the same color and pH value as those of orignal flux solution with no added, and the sample dipped to the flux solution which was added with additives mentioned above indicated a relatively good corrosion resistance compared to other samples. However, the flux solution added with $NH_4OH$, $Al(OH)_3$ and $H_2O_2$ exhibited a different color, sediment and a bad corrosion resistance. Consequently, it is considered that omission of water washing treatment may be able to perform by adding optimum additives to the original flux solution.

Studies on the Printing with Natural Dyes on Sappan Wood (소목 천연염료를 이용한 날염에 관한 연구)

  • Jun, Byung-Ik;Hwang, Jong-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.3
    • /
    • pp.239-245
    • /
    • 2003
  • This study is to research on printing method by use of colorants extracted from Sappan wood. As for the research, the stability of paste added by mordants, steaming condition, optimal mordant concentration, change of surface color and colorfastness were measured. The experiment showed that guar gum were stability among the sodium-alginate, modified starch, guar gum. And the surface color was best when the streaming time was 60 minutes, mordant concentration 3g/l. And for colorfastness experiment, colorfastness to drycleaning was good, but colorfastness to light and colorfastness to washing showed no desirable result.

  • PDF

A Study on the Treatment of Oil Contaminated Soils with Micro-nano Bubbles Soil Washing System (유류오염토양 처리를 위한 마이크로나노버블 토양세척에 관한 연구)

  • Choi, Ho-Eun;Jung, Jin-Hee;Han, Young-Rip;Kim, Dae-Yong;Jung, Byung-Gil;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.20 no.10
    • /
    • pp.1329-1336
    • /
    • 2011
  • The objectives of this study are to examine the processing of oils contamination soil by means of using a micronano-bubble soil washing system, to investigate the various factors such as washing periods, the amount of micro-nano bubbles generated depending on the quantity of acid injection and quantity of air injection, to examine the features involved in the elimination of total petroleum hydrocarbons (TPHs) contained in the soil, and thus to evaluate the possibility of practical application on the field for the economic feasibility. The oils contaminated soil used in this study was collected from the 0~15 cm surface layer of an automobile junkyard located in U City. The collected soil was air-dried for 24 hours, and then the large particles and other substances contained in the soil were eliminated and filtered through sieve No.10 (2 mm) to secure consistency in the samples. The TPH concentration of the contaminated soil was found to be 4,914~5,998 mg/kg. The micronano-bubble soil washing system consists of the reactor, the flow equalization tank, the micronano- bubble generator, the pump and the strainer, and was manufactured with stainless material for withstanding acidic phase. When the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 30 minutes were respectively identified as 4,931 mg/kg (18.9%), 4,678 mg/kg (18.9%) and, 4,513 mg/kg (17.7%). And when the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 120 minutes were respectively identified as4,256 mg/kg (22.3%), 4,621 mg/kg (19.7%) and 4,268 mg/kg (25.9%).

A Study for Remediation of Railroad Ballast Gravel Using Dry Washing Method (건식세척기술을 이용한 철도 도상자갈 정화 연구)

  • Bae, Jiyong;Jeong, Taeyang;Kim, Jae Hun;Lee, Sang Tak;Joo, Hyung Soo;Oh, Seung-Taek;Cho, Youngmin;Park, Duckshin
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.3
    • /
    • pp.365-373
    • /
    • 2017
  • This study proposes a newly developed dry washing method for removing pollutants such as total petroleum hydrocarbon (TPH) and oxidized iron from the surface of ballast gravel. A batch-type dry washing method showed a good performance in a previous study. In this study, a continuous-type dry washing system, instead of a batch-type system, was prepared to improve the efficiency of the system. A drier and a separator were also applied to this system as pre-treatment process, and the performance of this system was evaluated. In this experiment, blasting media was blasted on the polluted gravels through 12 nozzles by a pressure of $5-6kg/cm^2$ for 20-30 mins to remove TPH and oxidized iron. It was found to be possible to remove 80-90% of TPH and oxidized iron by using this system. Several ways to improve the performance were suggested in this study.

A Study on the Detergency of Alkali-treated Polyester Fabric - The effects of surface structure- (알칼리 감양가공이 Polyester 직물의 세척성에 미치는 영향 -표면구조의 효과를 중심으로-)

  • Shin Rae Won;Kim Sung Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.2
    • /
    • pp.1-9
    • /
    • 1986
  • To study the effects of surface structure of fiber on the decrement of fatty soil removal at high temperature, the following variables were selected: controled and alkali-treated P.E.T.(polyester) fabrics and chopped fibers as substrates to estimate the detergencies, different aging methods of soiled substrates, and different washing temperatures and surfactant solutions. Radiotagged tripalmitin was used as soil and the detergency was estimated by means of liquid scintillation counting method. The results were as following: The surface of the fiber became rough with many grooves and the hydrophilicity of the fiber was increased and the structure of the fabric became loose by alkali treatment. While the detergency of alkali-treated P.E.T. fabric was better than that of controled P. E. T. fabric, there was no significant differences between the detergencies of controled and alkali-treated chopped fibers. These results indicate that the increment of detergency of alkali-treated P.E.T. fabric is mainly resulted from the changes of fabric structure and the improved hydrophilicity of fiber by alkai treatment. The detergency of tripalmitin was increased with elevating temp. below the m.p. of tripalmitin, was decreased around the m.p., and again was increased above the m.p ..It is considered that the decrement of detergency around the m.p. is due to the diffusion of molten tripalmitin into the grooves on fiber surface, the inner part of fiber, and between fibers. When controled and alkali-treated soiled fabrics and soiled chopped fibers were washed in the distilled water and in the Na-DBS solution respectively, below $60^{\circ}C$ detergencies of alkali-treated fabrics and chopped fibers were improved. However above $60^{\circ}C$ this result was reversed. Therefore these results are regarded as the effects of grooves on fiber surface at high temp. and improved hydrophilicity at low temp. by alkali treatment. When controled and alkali-treated soiled fabrics and soiled chopped fibers were hot-aged before washing, the detergencies of both species were decreased generally. Because the soil was diffused into the grooves on fiber surface, the inner part of fiber, and between fibers during hot-aging. The detergencies of hot-aged species were also decreased above certain temp.. These results suggest that the decrement of detergency at high temp. be resulted not only from the diffusion of soil into the grooves on fiber surface, the inner part of fiber, and between fibers, but also from the characteristics of surfactant solutions.

  • PDF

A Study on the Surface Properties of Polymer Insulators for Improving Electrical Insulation Performance (전기 절연성능 향상을 위한 폴리머 애자의 표면 특성 연구)

  • Park, Yong Seob;Bae, Jae Sung;Hong, Byungyou;Lee, Jae Hyeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.63-67
    • /
    • 2021
  • In this paper, we investigated the surface properties of polymer insulators to improve electrical insulation performance. First, after washing the polymer insulator in various ways, its contact angle was increased, thereby improving the hydrophobic properties and electrical insulation properties. In addition, TiO2 thin films, which have been used as a photocatalytic material and have been applied to the polymer insulator surface of to enhance the surface and electrical insulating properties. For the sputtering method, the contact angle after coating the TiO2 thin film increased with increasing RF power, but it was lower compared to that before coating, indicating that the hydrophobic properties of the surface were slightly deteriorated. Consequently, the electrical properties of the polymer-insulating material were maintained or improved after the TiO2 thin-film coating.