• 제목/요약/키워드: surface pressure measurement

검색결과 480건 처리시간 0.031초

SEM과 AFM을 사용한 반도전 재료 내 카본블랙의 형태 및 분산성 측정 (Formation and Dispersion Measurement in Semiconducting Materials Using the SEM and AFM)

  • 이경용;양종석;남종철;최용성;박동하;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.236-237
    • /
    • 2005
  • To measure surface roughness and smoothness of semiconducting materials in power cable, we have investigated the formation and growth process of carbon black showed by changing the content of carbon black. The specimens were primarily kneaded in material samples of pellet form for 5 minutes on rollers ranging between 70[$^{\circ}C$] and 100[$^{\circ}C$]. Then they were produced as sheets after pressing for 20 minutes at 180[$^{\circ}C$] with a pressure of 200[kg/cm]. The contents of conductive carbon black were the variable, and their contents were 20, 30 and 40[wt%], respectively. The surface roughness and smoothness of specimens were measured by SEM and AFM. From SEM experimental result, carbon black in specimens formed matrix as a particles. Also we showed growth process of carbon black according to an increment of the content of carbon black. From AFM experimental result, surface roughness of specimens decreased according to an increment of the content of carbon black.

  • PDF

고정식 표면영상유속계 (FSIV)를 이용한 실시간 하천 유량 산정 (Real-time Discharge Measurement of the River Using Fixed-type Surface Image Velocimetry)

  • 김서준;류권규;윤병만
    • 한국수자원학회논문집
    • /
    • 제44권5호
    • /
    • pp.377-388
    • /
    • 2011
  • 표면영상유속계(SIV)는 영상 분석 기법을 이용하여 하천의 표면유속을 측정하고, 이를 토대로 유량을 산정하는 시스템이다. 본 연구에서는 고정식 표면영상유속계(FSIV) 시스템을 달천 수전교에 설치하여 실시간으로 연속적인 유량 측정을 실시하였다. 수전교에 적용된 FSIV의 하드웨어 시스템은 영상 획득을 위한 2대의 디지털 카메라와 컴퓨터, 그리고 수위 측정을 위한 초음파 수위계로 구성된다. 이 현장 장비들에서 획득된 실시간 영상과 수위 자료는 무선인터넷을 이용하여 실시간으로 홈페이지에 전송되며, 표면영상유속분석 소프트웨어를 이용하여 유량을 산정한다. FSIV에 의한 유량산정 결과는 직상류의 괴산댐 방류량과 FSIV와 동일한 지점에 설치된 Acoustic Doppler Velocity Meter (ADVM)를 설치한 후 유속지수법으로 산정된 유량과 비교하여 검토하였다. 댐 방류량과 비교한 결과 30$m^3/s$ 이상의 유량에서는 대부분 5~10%의 오차를 보였으며, ADVM을 이용하여 측정된 유량과 비교한 결과는 약 200$m^3/s$ 이상의 유량에서는 오차가 약 5 % 이내로 확인되었다. FSIV의 설치 경비와 운용에 드는 비용과 인력을 감안한다면, FSIV는 실시간으로 유량을 관측할 수 있는 좋은 대안이 될 것으로 판단된다.

함산소불소화가 저밀도 폴리에틸렌 표면의 그라프트 중합 및 그 표면 특성에 미치는 영향 (Effects of Oxyfluorination on Surface Graft Polymerization of Low Density Polyethylene Film and Its Surface Characteristics)

  • 윤석민;우상욱;정의경;배병철;박인준;이영석
    • 공업화학
    • /
    • 제21권3호
    • /
    • pp.343-348
    • /
    • 2010
  • 저밀도 폴리에틸렌(low density polyethylene, LDPE) 필름의 표면을 다양한 반응 조건하에서 함산소불소화하여 hydroperoxide 관능기를 도입시켜 표면특성을 변화시켰다. 또한 생성된 hydroperoxide 관능기를 반응 개시제로 친수성 그룹을 가지는 단량체인 acryl amide (AM)와 소수성 그룹을 가지는 단량체인 methyl methacrylate (MMA)를 그라프트 중합시켜 LDPE 필름의 표면을 2차 개질하였다. 또한 LDPE, 함산소불소화 된 LDPE (OFPE), AM 및 MMA 단량체가 그라프트 된 OFPE 필름의 표면특성은 1,1-diphenyl-2-picrylhydrazyl (DPPH), 감쇠전반사 분광법, 시차주사 열량분석기 및 접촉각 측정법 등으로 분석하였다. DPPH 라디칼 분석법의 결과로부터, OFPE의 hydroperoxide 관능기의 양은 함산소불소화 총압력과 F2 가스의 부분압이 증가함에 따라 증가함을 알 수 있었다. 접촉각 및 표면 자유에너지 분석결과로부터, 함산소불소화에 의해서 생성된 hydroperoxide 관능기와 AM과 같은 친수성 그룹을 가지는 단량체의 그라프트 중합은 LDPE 필름 표면에서 물과 같은 친수성 용매의 접촉각을 감소시키고, MMA와 같은 소수성 그룹을 가지는 단량체의 경우는 LDPE 필름 표면에서 methylene diiodide와 같은 비극성 용매의 표면 접촉각을 감소시켰다. 이는 AM 및 MMA 단량체의 그라프트 중합에 의한 것으로, LDPE 필름 표면은 친수성 및 소수성 용매에 대한 젖음성이 향상되었다.

압력센서를 이용한 수중항만공사 로봇의 실린더 길이 측정에 관한 연구 (Study on the measurement of the cylinder lengths of an underwater robot for harbour construction using a pressure sensor)

  • 김치효;김태성;이민기
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2012년도 춘계학술대회
    • /
    • pp.9-10
    • /
    • 2012
  • 수중 방파제 피복작업은 사석의 유실을 방지하기 위해 방파제 겉면에 2-3ton의 돌을 쌓는 작업으로 현재 잠수부에 의해 수작업으로 시공을 하고 있다. 수중에서의 사야문제와 작업의 특성상 잠수부의 육감에 의해 공사가 시행되며 작업 과정에서 산업재해가 빈번히 발생한다. 우리는 이러한 문제점을 해결하기 위해 수중 방파제 피복작업을 위한 수중항만공사 로봇을 개발하였다. 로봇의 유압 실린더 제어를 위한 위치 센서가 필요하며 기존 센서는 구동축에 부착되어 방수가 어렵고 건설현장에서 사용하기에는 내구성이 좋지 못하다. 하지만 압력센서는 유압라인상의 임의의 위치에 부착이 가능하므로 방수박스 내부에 설치할 수 있어 방수가 용이하고 내구성을 높일 수 있다. 따라서 본 논문에서는 압력센서를 이용하여 수중항만공사 로봇의 유압 실린더 길이를 간접적으로 측정하는 실린더 길이 옵서버를 설명한다.

  • PDF

패키지 기판 디스미어 공정의 대기압 플라즈마 처리 특성 (Process Characteristics of Atmospheric Pressure Plasma for Package Substrate Desmear Process)

  • 유선중
    • 한국진공학회지
    • /
    • 제18권5호
    • /
    • pp.337-345
    • /
    • 2009
  • 패키지 기판의 지름 $100{\mu}m$ 이하 미세 드릴 구멍의 경우 습식 디스미어 공정만으로는 구멍 내부의 스미어를 효과적으로 제거할 수 없다. 본 연구에서는 습식 디스미어 공정의 이전 단계에서 대기압 플라즈마를 처리하여 소수성의 기판 표면을 친수성으로 개질하고자 하였다. 대기압 플라즈마 공정은 리모트 DBD 방식의 전극을 이용하여 패키지 제조 공정에 적합한 인라인 형태의 장비로 구성되었다. 대기압 플라즈마를 처리한 결과 접촉각 기준으로 $71^{\circ}$의 소수성 절연 필름 표면이 $30^{\circ}$ 정도의 친수성 표면으로 개질되었다. 대기압 플라즈마 처리 유무에 따른 습식 디스미어 공정의 특성을 평가하기 위하여 절연 필름의 두께, 드릴 구멍 지름, 표면 조도의 변화를 측정하였는데, 대기압 플라즈마 처리 시 기판 전면에서 공정 특성의 균일도가 향상되는 것을 확인하였다. 또한 대기압 플라즈마 처리 유무에 따른 드릴 구멍의 SEM 사진 분석 결과 대기압 플라즈마 처리 시 구멍 내부의 스미어가 효과적으로 제거됨을 실험적으로 확인하였다.

Pressure Sensing Properties of AlN Thin Films Sputtered at Room Temperature

  • Seok, Hye-Won;Kim, Sei-Ki;Kang, Yang-Koo;Lee, Youn-Jin;Hong, Yeon-Woo;Ju, Byeong-Kwon
    • 센서학회지
    • /
    • 제23권2호
    • /
    • pp.94-98
    • /
    • 2014
  • Aluminum nitride (AlN) thin films with a TiN buffer layer have been fabricated on SUS430 substrate by RF reactive magnetron sputtering at room temperature under 25~75% $N_2$ /Ar. The characterization of film properties were performed using surface profiler, X-ray diffraction, X-ray photoelectron spectroscopy(XPS), and pressure-voltage measurement system. The deposition rates of AlN films were decreased with increasing the $N_2$ concentration owing to lower mass of nitrogen ions than Ar. The as-deposited AlN films showed crystalline phase, and with increasing the $N_2$ concentration, the peak of AlN(100) plane and the crystallinity became weak. Any change in the preferential orientation of the as-deposited AlN films was not observed within our $N_2$ concentration range. But in the case of 50% $N_2$ /Ar condition, the peak of (002) plane, which is determinant in pressure sensing properties, appeared. XPS depth profiling of AlN/TiN/SUS430 revealed Al/N ratio was close to stoichiometric value (45:47) when deposited under 50% $N_2/Ar$ atmosphere at room temperature. The output signal voltage of AlN sensor showed a linear behavior between 26~85 mV, and the pressure-sensing sensitivity was calculated as 7 mV/MPa.

Surface Modification with Atmospheric Microwave Agron Plasma Jet Assisted with Admixture of H2O2 and Analysis of Plasma Characteristics

  • Won, I.H.;Shin, H.K.;Kwon, H.C.;Kim, H.Y.;Kang, S.K.;Lee, J.K.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.544-545
    • /
    • 2013
  • Recently, low-temperature atmospheric-pressure plasmas have been investigated [1,2] for biomedical applications and surface treatments. Experiments for improving hydrophilicity of stainless steel (SUS 304) plate with atmospheric microwave argon and H2O2 mixture plasma jet [3] were carried out and experimental measurements and plasma simulations were conducted for investigating the characteristics of plasma for the process. After 30 s of low power (under 10 W) and low temperature (under $50^{\circ}C$) plasma treatment, the water contact angle decreased rapidly to around $10^{\circ}$ from $75^{\circ}$ and was maintained under $30^{\circ}$ for a day (24 hours). The surface free energy, calculated from the contact angles, increased. The chemical properties of the surface were examined by X-ray Photoelectron Spectroscopy (XPS) and the surface morphology and roughness were examined by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM) respectively. The characteristics of plasma sources with several frequencies were investigated by Optical Emission Spectroscopy (OES) measurement and one-dimensional Particle-in-Cell (PIC) simulation and zero-dimensional global simulation [4]. The relation between plasma components and the efficacy of the surface modification were discussed.

  • PDF

넓은 덕트 단면내의 음원 분포 규명 (Identification of the Sectional Distribution of Sound Source in a Wide Duct)

  • 허용호;이정권
    • 한국음향학회지
    • /
    • 제33권2호
    • /
    • pp.87-93
    • /
    • 2014
  • 덕트 내 음원 면에서의 음압과 입자 속도분포를 상세히 알 수 있다면, 주된 소음원들의 위치와 강도를 분석하여 전파특성을 잘 이해할 수 있고, 이에 따라 저소음화 설계에 유용한 정보로 활용가능하다. 이를 위한 기존의 방법들은 대개 단면상 위치와 무관한 일정 변수로 나타내는 제한점이 있다. 본 논문에서는 음원의 단면 분포를 높은 공간분해능으로 관찰할 수 있는 방법에 대해 연구하였다. 모드 합성법을 기반으로 감쇠파의 영향과 근접장 측정을 포함하는 행렬식을 유도하였으며, 컴프레션 드라이버에 의해 일부 단면이 가진된 유동이 없는 덕트 시스템에서 검증하였다. 감쇠파모드 개수의 증가에 따라 음압 스펙트럼을 더욱 정확하게 근사화 할 수 있었으며, 26개의 감쇠파 모드를 포함한 수렴 결과로부터 관심 헬름홀쯔 수 영역에서 -25 dB 이하의 오차로 예측할 수 있었다. 수렴된 모드 진폭들을 이용하여 kR = 1에서 음원 면에서의 음원변수 분포를 관찰한 결과, 실제 음원이 설치된 국소 위치에서 높은 음압과 입자 속도 값을 분명히 나타내는 것을 보였다. 또한, 감쇠 모드의 역추산시에 정규화기법을 도입하여, 과결정된 반경방향 모드에 의해 발생된 무의미한 피크들을 효과적으로 제거할 수 있었다.

대심도 준설 매립지반에서의 층별침하 계측관리에 관한 사례 연구 (Instrumentation Management of Differential Settlement of the Deep Soft Ground with Dredged Clay Reclaimed in the Upper)

  • 김태형;강승찬;장지건;허성훈
    • 한국지반신소재학회논문집
    • /
    • 제22권1호
    • /
    • pp.87-96
    • /
    • 2023
  • 상부에 준설매립점토층이 존재하고 점토층이 두껍게 분포되어 있는 부산항 신항만에서 측정된 지표침하 값과 층별침하 값은 많은 차이가 있다. 이런 결과의 원인과 해결방안을 찾기 위하여 연약지반 개량에 사용된 층별침하계의 실태, 층별침하계 형식별 특성, 설치방법, 계측 빈도, 계측데이터 관리방안, 결과의 정리 및 분석 등에 대해 고찰해 보았다. 대변형이 발생하는 대심도 연약지반 개량공사에서 스크류타입의 층별침하계의 경우 휨 변형이 다른 형식의 계측기에 비해 적어 망실의 우려도 적고 각 지층별로 천공하여 계측기를 설치하므로 데이터의 신뢰도도 상대적으로 높다. 정도 높은 침하계측 자료의 양이 많을수록 침하분석 정밀도는 높아지므로 표준시방서에서 제시한 계측빈도보다 기준을 강화하여 관리가 필요하다. 층별침하계 계측데이터의 관리는 측점별 지표침하량, 층별침하량, 간극수압계 침하량과 같이 해당 구간의 침하량과 성토고의 경시 그래프 작성하여 관리하는 것이 바람직하다. 침하분석은 압축특성이 다른 다층지반일 경우 층별침하 데이터를 이용하여 각 지층별 압밀특성을 각각 산정하여 침하분석이 이루어지는 게 더 타당하다.

글로우방전을 이용한 폴리에스테르섬유의 발수가공 (Water Repellent Finishes of Polyester Fiber Using Glow Discharge)

  • Mo, Sang Young;Kim, Gi Lyong;Kim, Tae Nyun;Chun, Tae Il
    • 한국염색가공학회지
    • /
    • 제5권4호
    • /
    • pp.29-41
    • /
    • 1993
  • In order to surface Hydrophobilization of Poly(ethylene terephthalate) (PET) fiber samples were treated in the atmosphere of CF$_{4}$ or $C_{2}$F$_{6}$glow discharge. The sample used in this study was PET film which is 75$\mu$m thick made by Teijin, O-Type(Japan). The cleaned samples were placed in plasma reactor made of pyrex glass cylinder, and plasma processing was carried out by glow discharge of CF$_{4}$ or $C_{2}$F$_{6}$ gas, being continuously fed by gas flow and continuously pumped out by a vacuum system. Electric power source for generate plasma state was sustained alternating current(60Hz) and voltage was sustained 600 volt. The duration of plasma treatment varied from 15 to 120 seconds except special case, the monomer gase pressure varied from 0.02 to 0.3 Torr and power range was 10 to 90 watts. The hydrophobic features of changed PET surface were evaluated by contact angle measurement and surface chemical characteristics were analyzed by ESCA. Results can be summerized as follows. 1. The most favorable setting position of substrate was the center area between the two electrodes. 2. $C_{2}$F$_{6}$ discharge current was lower than that of CF$_{4}$ when same voltage was sustained. Treated efficiency between CF$_{4}$ and $C_{2}$F$_{6}$ did not revealed significant differences under same electric power(wattage). 3. When monomer pressure is very low below 0.02 torr, as though substrate is exposed to CF$_{4}$ or $C_{2}$F$_{6}$ plasma, it tend to be hydrophilic through a little of fluorine bond and a great deal of oxidizing reaction. 4. There brought good hydrophobilization when monomer pressure was more 0.1 torr and duration of glow discharge treatment was over 45 seconds. When monomer pressure was too high, discharge current became low. Although prolong the duration, there was no more high hydrophobilization. 5. According to ESCA analysis, there were a little CF bond and a prevailing CF$_{2}$ bond in CF$_{4}$-treated substrate. There were CF$_{3}$, a little CF and a prevailing CF$_{2}$ bond in $C_{2}$F$_{6}$-treated substrate.d substrate.

  • PDF