• Title/Summary/Keyword: surface heat flux

Search Result 759, Processing Time 0.033 seconds

A Combustion Characteristic Analysis of Sandwich Panel Core Using Radiation Heat Flux (복사열을 이용한 샌드위치 패널 심재의 연소특성 분석)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.25-31
    • /
    • 2007
  • The combustion characteristics and combustion heat of sandwich panel cores were analysed using variable external irradiation level. The characteristics such as ignition time, critical heat flux, ignition temperature and surface temperature profile were measured. Fuel samples were exposed to incident heat fluxes from 15 to $50\;kW/m^2$. For the measurement of various combustion characteristics, the size of specimen was $100\;mm\;{\times}\;100\;mm\;{\times}\;50\;mm$ and the samples were 3 different kinds. As results, Type B showed the best characteristics in measurement of combustion heat and ignition temperature and Type C showd the best characteristics in critical heat flux and surface temperature profile than that of the other two. In conclusion, we knew that Type C had the best performance in fire safety from all data of this study.

Local Heat Transfer Characteristics in Convective Partial Boiling by Impingement of Free-Surface/Submerged Circular Water Jets (미세 원형 충돌수제트의 부분 대류비등에 있어서 자유표면/잠입 제트의 국소 열전달 특성)

  • 조형희;우성제;신창환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.441-449
    • /
    • 2002
  • Single-phase convection and partial nucleate boiling in free-surface and submerged jet impingements of subcooled water ejected through a 2-mm-diameter circular pipe nozzle were investigated by local measurements. Effects of jet velocity and nozzle-to-imping-ing surface distance as well as heat flux on distributions of wall temperature and heat transfer coefficients were considered. Incipience of boiling began from far downstream in contrast with the cases of the planar water jets of high Reynolds numbers. Heat flux increase and velocity decrease reduced the temperature difference between stagnation and far downstream regions with the increasing influence of boiling in partial boiling regime. The chance in nozzle-to-impinging surface distance from H/d=1 to 12 had a significant effect on heat transfer around the stagnation point of the submerged jet, but not for the free-surface jet. The submerged jet provided the lower cooling performance than the free-surface jet due to the entrainment of the pool fluid of which temperature increased.

Lumped System Analysis on the Lunar Surface Temperature Using the Bottom Conductive Heat Flux Model (달 표면온도 예측을 위한 집중계 해석방법과 하부 열유속 모델의 적용)

  • Kim, Taig Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.1
    • /
    • pp.66-74
    • /
    • 2019
  • Instead of securing thermophysical properties throughout the entire lunar surface, a theoretical method to predict the lunar surface temperature accurately using improved Lumped System Model (LSM) was developed. Based on the recently published research, thermal mass per unit area at the top regolith layer is assumed uniform. The function of bottom conductive heat flux was introduced under the theoretical background. The LSM temperature prediction agrees well with the DLRE measurement except for dusk, dawn and high latitude region where the solar irradiation is weak. The relative large temperature discrepancy in such region is caused by the limit of the bottom conductive heat flux model. The surface temperature map of the moon generated by the LSM method is similar to the DLRE measurement except for the anomalous temperature zones where surface topography and thermophysical properties appear in highly uneven.

Estimation of Land Surface Energy Fluxes using CLM and VIC model (CLM과 VIC 모형을 활용한 지표 에너지 플럭스 산정)

  • Kim, Daeun;Ray, Ram L.;King, Seokkoo;Choi, Minha
    • Journal of Wetlands Research
    • /
    • v.18 no.2
    • /
    • pp.166-172
    • /
    • 2016
  • Accurate understanding of land surface is essential to analyze energy exchanges between earth surface and atmosphere. For the quantization of energy fluxes, the various researches about Land Surface Model(LSM) have been progressed. Among the various LSMs, the researches using Common Land Model(CLM) and Variable Infiltration Capacity(VIC) model are performed briskly. The CLM which is advanced LSM can calculate realistic results with few user defined parameters. The VIC model which is also typical LSM is widely used for estimation of energy fluxes and runoff in various fields. In this study, the energy fluxes which are net radiation, sensible heat flux, and latent heat flux were estimated using CLM and VIC model at Southern Sierra-Critical Zone Observatory(SS-CZO) site in California, United States. In case of net radiation and sensible heat flux, both models showed good agreement with observations, however, the CLM showed underestimated patterns of net radiation and sensible heat flux during precipitation period. In case of latent heat flux, the CLM represented better estimation of latent heat flux than VIC model which underestimated the latent heat flux. Through the estimation of energy fluxes and analysis of models' pros and cons, the applicability of CLM and VIC models and need of multi-model application were identified.

A Study on the Inverse Analysis of Surface Radiation in a Cylindrical Enclosure (원통형상에서의 표면복사 역해석에 관한 연구)

  • KIm, Ki-Wan;Baek, Seung-Wook;Ryou, Hong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.6
    • /
    • pp.705-712
    • /
    • 2004
  • An inverse boundary analysis of surface radiation in an axisymmetric cylindrical enclosure has been conducted in this study. Net energy exchange method was used to calculate the radiative heat flux on each surface, and a hybrid genetic algorithm was adopted to minimize an objective function, which is expressed by sum of square errors between estimated and measured or desired heat fluxes on the design surface. We have examined the effects of the measurement error as well as the number of measurement points on the estimation accuracy. Furthermore, the effect of a variation in one boundary condition on the other boundary conditions was also investigated to get the same desired heat flux and temperature distribution on the design surface.

A preliminary study on material effects of critical heat flux for downward-facing flow boiling

  • Wang, Kai;Li, Chun-Yen;Uesugi, Kotaro;Erkan, Nejdet;Okamoto, Koji
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2839-2846
    • /
    • 2021
  • In this study, experiments of downward-facing flow boiling were conducted to investigate material effects on CHF. Experiments were conducted using aluminum, copper, and carbon steel. It was found that different materials had different CHFs. Aluminum has the biggest CHF while copper has the lowest CHF for each mass flux. After experiment, surface wettability increased and surface became rougher, which was probably due to the oxidation process during nucleate boiling. The CHF difference is likely to be related to the surface wettability, roughness and thermal effusivity, which influences the bubble behavior and in turn affects CHF. Further studies are needed to determine which factor is dominant.

Sensible heat flux estimated by gradient method at Goheung bay wetland (고흥만 습지에서 경도법으로 산출한 현열플럭스)

  • Kim, Dong-Su;Kwon, Byung-Hyuk;Kim, Il Kyu;Kang, Dong Hwan;Kim, Kwang-Ho;Kim, Geun-Hoi;Park, Jun-Sang
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.20 no.2
    • /
    • pp.156-167
    • /
    • 2008
  • Meorological data have been collected to monitor the wetland area in Goheung bay since 2003 and four intensive observations were conducted to study effects of the atmospheric turbulence on the energy budget and the ecological changes. We improved an algorithm to estimate the sensible heat flux with routine data. The sensible heat flux estimated by gradient method was in good agreement with that measured by precision instruments such as surface layer scintillometer and ultrasonic anemometer. Diurnal variations of sensible heat flux showed analogous tendency to those of temperature gradient. When the vertical wind shear of horizontal wind components was weak, even though temperature gradient was strong, the gradient method underestimated the sensible heat flux. A compensation for the cloud will make this gradient method be a helpful tool to monitor the ecosystem without expensive instruments except for weak wind shear and temperature gradient.

A Theoretical Study on the Boiling Heat Transfer Performance of Tubes with Extended Surfaces (확대 전열관의 비등열전달에 관한 이론적 연구)

  • Jho, S.G.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.45-56
    • /
    • 1999
  • The performance of vertical and horizontal tubes with extended surface of rectangular and triangular cross section was investigated theoretically for boiling heat transfer. A simple method for numerical program assuming one-dimensional heat flow was used to predict the performance of these extended surface tubes. The object of this study was to predict the effects of the height, thickness, numbers and, clearance of the extended surface on boiling heat transfer. The results showed that extended surfaces are quite effective as compared to plane surfaces especially near the bum-out point and to promote heat flux in boiling heat transfer.

  • PDF

Vertical Structure of the Coastal Atmospheric Boundary Layer Based on Terra/MODIS Data (Terra/MODIS 자료를 이용한 연안 대기경계층의 연직구조)

  • Kim, Dong Su;Kwon, Byung Hyuk
    • Atmosphere
    • /
    • v.17 no.3
    • /
    • pp.281-289
    • /
    • 2007
  • Micrometeorlogical and upper air observation have been conducted in order to determine the atmospheric boundary layer depth based on data from satellite and automatic weather systems. Terra/MODIS temperature profiles and sensible heat fluxes from the gradient method were used to estimate the mixed layer height over a coastal region. Results of the integral model were in good agreement with the mixed layer height observed using GPS radiosonde at Wolsung ($35.72^{\circ}N$, $129.48^{\circ}E$). Since the variation of the mixed layer height depends on the surface sensible heat flux, the integral model estimated properly the mixed layer height in the daytime. The buoyant heat flux, which is more important than the sensible heat flux in the coastal region, must be taken into consideration to improve the integral model. The vertical structure of atmospheric boundary layer can be analyzed only with the routine data and the satellite data.

Heat Flux Analysis of Lunar Lander for Potential Landing Candidate Area (달 착륙선의 착륙 후보지별 열 유입량 분석)

  • Park, Tae-Yong;Chae, Bong-Geon;Lee, Jang-Joon;Kim, Jung-Hoon;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.4
    • /
    • pp.324-331
    • /
    • 2018
  • The thermal environment on lunar surface is more severe than that of earth's surface or low earth orbit because of the long daytime and nighttime due to 28 days of rotation cycle of moon. Thus, analyzing heat flux on lunar lander at potential landing sites is important to determine the landing site in its initial design phase. In this study, thermal model of lunar regolith that can simulate lunar surface temperature was constructed for analyzing thermal characteristics according to the potential landing sites of lunar lander. The heat flux analyses were performed various latitudes of equator, mid-latitude, polar regions, lunar mare and highland. In addition, we also investigated the heat flux of lunar lander when it is landed on adjacent area to hill.