• Title/Summary/Keyword: surface effect

Search Result 16,277, Processing Time 0.049 seconds

Antimicrobial effect of infrared diode laser utilizing indocyanine green against Staphylococcus aureus biofilm on titanium surface (티타늄 표면에 형성한 Staphylococcus aureus 바이오필름에 대한 인도시아닌 그린을 활용한 광역학치료의 항미생물 효과)

  • Seung Gi Kim;Si-Young Lee;Jong-Bin Lee;Heung-Sik Um;Jae-Kwan Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.55-63
    • /
    • 2024
  • Purpose: This study aimed to assess the antimicrobial efficacy of an 810-nm infrared diode laser with indocyanine green (ICG) against Staphylococcus aureus on sandblasted, large grit, and acid-etched (SLA) titanium surfaces, comparing its effectiveness with alternative chemical decontamination modalities. Materials and Methods: Biofilms of S. aureus ATCC 25923 were cultured on SLA titanium disks for 48 hours. The biofilms were divided into five treatment groups: control, chlorhexidine gluconate (CHX), tetracycline (TC), ICG, and 810-nm infrared diode laser with ICG (ICG-PDT). After treatment, colony-forming units were quantified to assess surviving bacteria, and viability was confirmed through confocal laser-scanning microscope (CLSM) imaging. Results: All treated groups exhibited a statistically significant reduction in S. aureus (P < 0.05), with notable efficacy in the CHX, TC, and ICG-PDT groups (P < 0.01). While no statistical difference was observed between TC and CHX, the ICG-PDT group demonstrated superior bacterial reduction. CLSM images revealed a higher proportion of dead bacteria stained in red within the ICG-PDT groups. Conclusion: Within the limitations, ICG-PDT effectively reduced S. aureus biofilms on SLA titanium surfaces. Further investigations into alternative decontamination methods and the clinical impact of ICG-PDT on peri-implant diseases are warranted.

A Comparative Study of Vegetation Phenology Using High-resolution Sentinel-2 Imagery and Topographically Corrected Vegetation Index (고해상도 Sentinel-2 위성 자료와 지형효과를 고려한 식생지수 기반의 산림 식생 생장패턴 비교)

  • Seungheon Yoo;Sungchan Jeong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.26 no.2
    • /
    • pp.89-102
    • /
    • 2024
  • Land Surface Phenology (LSP) plays a crucial role in understanding vegetation dynamics. The near-infrared reflectance of vegetation (NIRv) has been increasingly adopted in LSP studies, being recognized as a robust proxy for gross primary production (GPP). However, NIR v is sensitive to the terrain effects in mountainous areas due to artifacts in NIR reflectance cannot be canceled out. Because of this, estimating phenological metrics in mountainous regions have a substantial uncertainty, especially in the end of season (EOS). The topographically corrected NIRv (TCNIRv) employs the path length correction (PLC) method, which was deduced from the simplification of the radiative transfer equation, to alleviate limitations related to the terrain effects. TCNIRv has been demonstrated to estimate phenology metrics more accurately than NIRv, especially exhibiting improved estimation of EOS. As the topographic effect is significantly influenced by terrain properties such as slope and aspect, our study compared phenology metrics estimations between south-facing slopes (SFS) and north-facing slopes (NFS) using NIRv and TCNIRv in two distinct mountainous regions: Gwangneung Forest (GF) and Odaesan National Park (ONP), representing relatively flat and rugged areas, respectively. The results indicated that TCNIR v-derived EOS at NFS occurred later than that at SFS for both study sites (GF : DOY 266.8/268.3 at SFS/NFS; ONP : DOY 262.0/264.8 at SFS/NFS), in contrast to the results obtained with NIRv (GF : DOY 270.3/265.5 at SFS/NFS; ONP : DOY 265.0/261.8 at SFS/NFS). Additionally, the gap between SFS and NFS diminished after topographic correction (GF : DOY 270.3/265.5 at SFS/NFS; ONP : DOY 265.0/261.8 at SFS/NFS). We conclude that TCNIRv exhibits discrepancy with NIR v in EOS detection considering slope orientation. Our findings underscore the necessity of topographic correction in estimating photosynthetic phenology, considering slope orientation, especially in diverse terrain conditions.

TECHNICAL STUDY ON THE CONTROLLING MECHANIQUES OF THE ENVIRONMENTAL FACTORS IN THE MUSHROOM GROWING HOUSE IN CHONNAM PROVINCE (전남지방(全南地方)에 있어서의 양송이 재배(栽培)에 최적(最適)한 환경조건(環境條件) 조절법분석(調節法分析)에 관(關)한 연구(硏究))

  • Lee, Eun Chol
    • Journal of Korean Society of Forest Science
    • /
    • v.9 no.1
    • /
    • pp.1-44
    • /
    • 1969
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demostrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental houses showed a sufficient heat insulation on effect to protect insides of the houses from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar houses to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on-ground type house, and (2) the solar heat generating system should be reconstructed properly. A trial solar heat generating system is shown in Fig. 40. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom houses. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that x is the outside temperature and y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between x and y can be expressed by the following regression lines. Underground iron pipe ventilation system ${\cdots}{\cdots}$ y=0.9x-12.8 Underground earthen pipe ventilation system ${\cdots}{\cdots}$y=0.96x-15.11 Vertical side wall ventilation system${\cdots}{\cdots}$ y=0.94x-17.57 5. The experimental results have shown that the relationships existing between the admitted and expelled air and the $Co_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 1) If it is assumed that x is an air speed cm/sec. and y is an expelled air speed in cm/sec. in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below: 2) If it is assumed that x is an admitted volume of air in $m^3/hr$ and y is an expelled volume of air in $m^3/hr$ in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below. 3) If it is assumed that the expelled air speed in cm/sec and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as x and y, respectively, since the y is a function of the x, the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}$ y=0.54X+0.84 4) If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as x, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as y, in a natural ventilation system, since the y is a function of the x the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}{\cdots}$ y=114.53-6.42x 5) If it is assumed that the expelled volume of air is shown as x and the $CO_2$ concentration which is expressed by multiplying 1000 times the actual of $CO_2$ % is shown as y in a natural ventilation system, since the y is a function of of the x, the relationships that exist between x and y can be expressed by the following exponent equation: G.E. (100%)-C.V. (50%) ventilation system${\cdots}{\cdots}$ $$y=127.18{\times}1.0093^{-X}$$ 6. The experimental results have shown that the ratios of the crass sectional area of the G.E. and C.V. vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: G.E. (admitting vent of the underground ventilation)${\cdots}{\cdots}$ 0.30-0.5% (controllable) C.V. (expelling vent of the ceiling ventilation)${\cdots}{\cdots}$ 0.8-1.0% (controllable) 7. Among several heating devices which were studied in the experiments, the hot-water boilor which was modified to be fitted both as hot-water toiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Studies on the Physical and Chemical Denatures of Cocoon Bave Sericin throughout Silk Filature Processes (제사과정 전후에서의 견사세리신의 물리화학적 성질변화에 관한 연구)

  • 남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.16 no.1
    • /
    • pp.21-48
    • /
    • 1974
  • The studies were carried out to disclose the physical and chemical properties of sericin fraction obtained from silk cocoon shells and its characteristics of swelling and solubility. The following results were obtained. 1. The physical and chemical properties of sericin fraction. 1) In contrast to the easy water soluble sericin, the hard soluble sericin contains fewer amino acids include of polar side radical while the hard soluble amino acid sach as alanine and leucine were detected. 2) The easy soluble amino acids were found mainly on the outer part of the fibroin, but the hard soluble amino acids were located in the near parts to the fibroin. 3) The swelling and solubility of the sericin could be hardly assayed by the analysis of the amino acid composition, and could be considered to tee closely related to the compound of the sericin crystal and secondary structure. 4) The X-ray patterns of the cocoon filament were ring shape, but they disappeared by the degumming treatment. 5) The sericin of tussah silkworm (A. pernyi), showed stronger circular patterns in the meridian than the regular silkworm (Bombyx mori). 6) There was no pattern difference between Fraction A and B. 7) X-ray diffraction patterns of the Sericin 1, ll and 111 were similar except interference of 8.85A (side chain spacing). 8) The amino acids above 150 in molecular weight such as Cys. Tyr. Phe. His. and Arg. were not found quantitatively by the 60 minutes-hydrolysis (6N-HCI). 9) The X-ray Pattern of 4.6A had a tendency to disappear with hot-water, ether, and alcohol treatment. 10) The partial hydrolysis of sericin showed a cirucular interference (2A) on the meridian. 11) The sericin pellet after hydrolysis was considered to be peptides composed with specific amino acids. 12) The decomposing temperature of Sericin 111 was higher than that of Sericin I and II. 13) Thermogram of the inner portioned sericin of the cocoon shell had double endothermic peaks at 165$^{\circ}C$, and 245$^{\circ}C$, and its decomposing temperature was higher than that of other portioned sericin. 14) The infrared spectroscopic properties among sericin I, II, III and sericin extracted from each layer portion of the cocoon shell were similar. II. The characteristics of seriein swelling and solubility related with silk processing. 1) Fifteen minutes was required to dehydrate the free moisture of cocoon shells with centrifugal force controlled at 13${\times}$10$^4$ dyne/g at 3,000 R.P.M. B) It took 30 minutes for the sericin to show positive reaction with the Folin-Ciocaltue reagent at room temperature. 3) The measurable wave length of the visible radiation was 500-750m${\mu}$, and the highest absorbance was observed at the wave length of 650m${\mu}$. 4) The colorimetric analysis should be conducted at 650mu for low concentration (10$\mu\textrm{g}$/$m\ell$), and at 500m${\mu}$ for the higher concentration to obtain an exact analysis. 5) The absorbing curves of sericin and egg albumin at different wave lengths were similar, but the absorbance of the former was slightly higher than that of the latter. 6) The quantity of the sericin measured by the colorimetric analysis, turned out to be less than by the Kjeldahl method. 7) Both temperature and duration in the cocoon cooking process has much effect on the swelling and solubility of the cocoon shells, but the temperature was more influential than the duration of the treatment. 8) The factorial relation between the temperature and the duration of treatment of the cocoon cooking to check for siricin swelling and solubility showed that the treatment duration should be gradually increased to reach optimum swelling and solubility of sericin with low temperature(70$^{\circ}C$) . High temperature, however, showed more sharp increase. 9) The more increased temperature in the drying of fresh cocoons, the less the sericin swelling and solubility were obtained. 10) In a specific cooking duration, the heavier the cocoon shell is, the less the swelling and solubility were obtained. 11) It was considered that there are differences in swelling or solubility between the filaments of each cocoon layer. 12) Sericin swelling or solubility in the cocoon filament was decreased by the wax extraction.. 13) The ionic surface active agent accelerated the swelling and solubility of the sericin at the range of pH 6-7. 14) In the same conditions as above, the cation agent was absorbed into the sericin. 15) In case of the increase of Ca ang Mg in the reeling water, its pH value drifted toward the acidity. 16) A buffering action was observed between the sericin and the water hardness constituents in the reeling water. 17) The effect of calcium on the swelling and solubility of the sericin was more moderate than that of magnecium. 18) The solute of the water hardness constituents increased the electric conductivity in the reeling water.

  • PDF

The study for the roles of intratracheally administered histamine in the neutrophil-mediated acute lung injury in rats: (호중구를 매개하는 백서의 급성 폐손상의 병리가전에 있어 기도내로 투여한 히스타민의 역활에 관하여)

  • Koh, Youn-Suck;Hybertson, Brooks M.;Jepson, Eric K.;Kim, Mi-Jung;Lee, In-Chul;Lim, Chae-Man;Lee, Sang-Do;Kim, Dong-Soon;Kim, Won-Dong;Repine, John E.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.308-322
    • /
    • 1996
  • Background : Neutrophils are considered to play critical roles in the development of acute respiratory distress syndrome. Histamine, which is distributed abundantly in lung tissue, increases the rolling of neutrophills via increase of P-selectin expression on the surface of endothelial cells and is known to have some interrelationships with IL-1, IL-8 and TNF-$\alpha$. We studied to investigate the effect of the histamine on the acute lung injury of the rats induced by intratracheal insufflation of TNF-$\alpha$ which has less potency to cause lung injury compared to IL-1 in rats. Methods : We intratracheally instilled saline or TNF(R&D, 500ng), IL-1(R&D, 50ng)or histamine of varius dose(1.1, 11 and $55\;{\mu}g/kg$) with and without TNF separately in Sprague-Dawley rats weighing 270-370 grams. We also intratracheally treated IL-1(50ng) along with histamine($55\;{\mu}g/kg$). In cases, there were synergistic effects induced by histamine on the parameters of TNF-induced acute lung injury, antihistamines(Sigma, mepyramine as a $H_1$ receptor blockade and ranitidine as a $H_2$ receptor blockade, 10 mg/kg in each)were co-administered intravenously to the rats treated TNF along with histamine($1.1\;{\mu}g/kg$) intratraeheally. Then after 5 h we measured lung lavage neutrophil numbers, lavage cytokine-induced neutrophil chemoattractants(CINC), lung myeloperoxidase activity(MPO) and lung leak. We also intratracheally insufflated TNF with/without histamine($11\;{\mu}g/kg$), then after 24 h measured lung leak in rats. Statistical analyses were done by Kruskal-Wallis nonparametric ANOVA test with Dunn's multiple comparison test or by Mann-Whitney U test. Results : We found that rats given TNF, histamine alone(11 and $55\;{\mu}g/kg$), and TNF with histamine(l.1, 11, and $55\;{\mu}g/kg$) intratracheally had increased (p<0.05) lung MPO activity compared with saline-treated control rats. TNF with histamine $11\;{\mu}g/kg$ had increased MPO activity (P=0.0251) compared with TNF-treated rats. TNF and TNF with histamine(1.1, 11, and $55\;{\mu}g/kg$) intratracheally had all increased (p<0.05) lung leak, lavage neutophil numbers and lavage CINC activities compared with saline. TNF with histamine $1.1\;{\mu}g/kg$ had increased (p=0.0367) lavage neutrophil numbers compared with TNF treated rats. But there were no additive effect of histamine with TNF compared with TNF alone in acute lung leak on 5 h and 24 h in rats. Treatment of rats with the $H_1$ and $H_2$ antagonists resulted in inhibitions of lavage neutrophil accumulations and lavage CINC activity elevations elicited by co-treated histamine in TNF-induced acute lung injury intratracheally in rats. We also found that rats given IL-1 along with histamine intratracheally did not have increase in lung leak compared with IL-1 treated rats. Conclusion : Histamine administered intratracheally did not have synergistic effects on TNF-induced acute lung leak inspite of additive effects on increase in MPO activity and lavage neutrophil numbers in rats. These observations suggest that instilling histamine intratracheally would not play synergistic roles in neutrophil-mediated acute lung injury in rats.

  • PDF

Utilization of Phosphorus and Nitrogen Fertilizers by Paddy Rice -A six years internationally coordinated study using isotopes- (수도(水稻)에 대(對)한 인산(燐酸) 및 질소질비료(窒素質肥料)의 효용에 관(關)한 연구(硏究) -동위원소(同位元素)를 이용(利用)한 6 개년간(個年間)의 국제적(國際的) 공동시험결과(共同試驗結果)-)

  • Kim, H.S.;Cho, B.H.;Lee, C.Y.;Lee, E.W.;Shim, S.C.;Yoo, S.H.;Kwon, Y.W.;Jo, J.S.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.1 no.1
    • /
    • pp.13-26
    • /
    • 1968
  • To establish the most efficient method of nitrogen and phosphorus fertilization in paddy rice a series of internationally coordinated research using $N^{15}\;P^{32}$ isotopes were carried out from the year 1962 through 1967, supervised by the Joint FAO/IAEA Division of Atomic Energy in Agriculture under the auspicies of FAO, UN. In Korea College of Agriculture, Seoul National University had been participated in the Coordinated Research Programme from the year 1963 through the last year, arid the results obtained through the six years' researches are summarized as follows: 1. In the application of superphosphate broadcasting or placement at the surface of paddy as basal dressing was most efficient. 2. Split or late application of superphosphate did not affect the grain yield of the rice, but its efficiency in the rice plant uptake was less than in the case of basal dressing of whole amounts. 3. The contents of available soil phoshorus of the experimental sites in Korea were above 60 ppm, and the efficiency of phosphorus utilization of the rice from the fertilizer was approximately 10 per cent. The grain yield response of the rice to phosphorus application in Korea was rather small comparing to those of other countries. 4. The nitrogen uptake of the rice plants from the fertilizer was most efficient when the fertilizer was applied at the time of ear prime growth. However, the most efficient utilization of nitrogen did not necessarily accompany the maximum yield of the rice and basic application of adequate amount of nitrogen was required to secure proper number of panicles. 5. In the application of nitrogenous fertilizer shallow placement at 5 cm depth was most efficient. The effect of split application of nitrogen was not so noticeable. It seemed due to the fact that total application amount of nitrogen, 60 kg N/ha, was smaller than that of usual dosage in Korea. 6. The efficiency of nitrogen utilization of the rice from the fertilizer was about 40 percent in Korea, and the yield reponse of the rice plant to nitrogen application was remarkable comparing to those of other countries, showing the marked differences in the fertilizer efficiency and grain yield according to the application method. 7. The nitrogen uptake of the rice plant was not likely affected by the time and the rate of phosphorus application whereas the efficiency of phosphorus utilization was affected to some degree by the method of nitrogen application.

  • PDF

Studies on the Cutting Managemente of Pasture during the Mid Summer Season I. Effect of cutting management on tall fescue dominated pasture (고온기 초지의 예취관리에 관한 연구 I. 고온기 예취방법이 tall fescue 우점초지의 재생 , 잡초발생 및 수량에 미치는 영향)

  • Seo, S.;Han, Y.C.;Park, M.S.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.5 no.1
    • /
    • pp.22-32
    • /
    • 1985
  • Optimum pasture management during the summer season is an important factor to maintain good regrowth and persistence of pasture in Korea. This experiment was carried out to investigate the effects of the cutting management on the dead plant, weed appearance, regrowth and carbohydrate reserves in stubble, and dry matter yield of tall fescue dominated pasture during the mid summer season. For the test, a split plot design with 4 replications was treated with 2 different the third cutting times (July 12 and Aug. 4) as the mainplots, and 3 different cutting heights (3, 6 and 9 cm) at the third cut as the subplots, and the experiment was done at the experimental field of the Livestock Experiment Station, in Suweon, 1984. The results obtained are summarized as follows: 1. Considering the meteorological conditions during the experimental period, the temperature was a little higher by $2^{\circ}C$ than that of average year, especially the first and second decade of August were high. And the precipitation of 1984 tended to be low when compared with the average year. 2. Temperature of soil surface and underground tended to increase by $1-3^{\circ}C$ as the stubble height was low during the summer season. 3. Regrowth leaf length and leaf area after the third cut increased significantly with the high cutting height at the third cut. 4. A significant higher total nonstructural carbohydrate (TNC) content in stubble after the third cut was observed in the high stubble cut on July 12. The results indicate that the high stubble height reserves more carbohydrates for early regrowth stage after the third cut when compared with the low stubble. On Aug. 4, however, the recovery of TNC contents after the third cut was not effective due to high temperature and rainfall. 5. The percentage of dead plant after the third cut was found to be high with the low cutting height during the mid summer season (p<0.05). 6. With the low stubble height on July 12 cut, it was appeared that the percentage of weed was significantly increased (p<0.05), and main weeds appeared after the third cut were Echinochloa crusgalli>Digitaria sanguinalis>Cyperus iria>Rumex crispus, and so on. In case of cut on Aug. 4, weed appearance was no difference at three cutting heights. 7. Dry matter yield at the third cut was increased in the plot of cutting on Aug. 4 and stubble height (p<0.05). However, yields at the fourth and fifth cut were increased with high stubble height (p<0.05), regardless of harvest time. 8. In total dry matter yield after the third cut, there was no significant difference between the cutting time and forage yield. However, total yield on July 12 was increased with the high stubble height (p<0.05). 9. From the above results, it is suggested that the 9 cm cutting height during the mid summer season is the most effective for good regrowth, weed control and forage yield of tall fescue dominated pasture.

  • PDF

Histological and Biochemical Studies on the Rooting of Hard-wood Cuttings in Mulberry (Morus species) (뽕나무 古條揷木의 發根에 關한 組織 및 生化學的 硏究)

  • Lim, Su-Ho
    • Journal of Sericultural and Entomological Science
    • /
    • v.23 no.1
    • /
    • pp.1-31
    • /
    • 1981
  • Rootability of the hardwood cuttings of mulberry was related not only histological characteristics but dependent on biochemical properties. In this connection, the characteristics of the hardwood cuttings were histologically observed and the growth substances produced by the cuttings were also identified by means of mung bean bioassay. Amino acid, carbohydrate, nucleic acid contents, and the C/N ratio were also analysed. The results are summarized as follows. 1. There were differences in rootability of cuttings between mulberry species and varieties Among the three mulberry species tested, Morus Lhou Koidz. showed the highest rootability while M. bombycis showed the lowest one. In varietal differences in rootability, it was shown that the varieties could be grouped according to rootability: high varieties(above 80%), medium(41~79%), and low(below 40%). The higher varieties were Kemmochi, Nakamaki, Kosen, and Wusuba roso. 2. The histological characteristic of the hardwood cuttings most closely related to rootability was cell layer arrangement in the sclerenchyma tissue. The lower rootability varieties developed two or three overlapping cell layers in the bark tissue and in the higher rootability varieties they were scattered over the primary cortex. 3. In the higher rootability varieties, there was a positive correlation between the development of root primodia and rootability of the hardwood cuttings. It was also shown that there was a close relationship between the size of primodia and the surface area of the lenticel with rootability of the cuttings. 4. Effect of growth substances extracted from the hardwood cuttings were determined by mung bean bioassay. The higher rootability varieties usually showed higher activities of the growth substances, in contrast the lower rootability varieties showed higher activities of the inhibitory substances. 5. It was evident that the substance separated by paper chromatography was identified as indole acetic acid with $R_f$ value ranging from 0.3 to 0.5. The other substances detected at a $R_f$ value ranging from 0.8 to 1.0 and origin to 0.1 were also responsible for rooting. 6. There exists a quantitatively different distribution of growth substances in a synergistic system in the tissues of cuttings, and the balance between growth and inhibitory substances gives rise to the development of rooting. Particularly, no descent of the substances from winter buds resulted in no rooting of cuttings but these substances were produced a week after planting in a warm environment. 7. It was shown that there were positive correlations between carbohydrate ($r=0.72^*$) and total sugar ($r=0.67^*$) and rootability, respectively, but there were negative correlations between reducing sugars ($r=-0.75^*$) and rootability. 8. High C/N ratio gave rise to high rootability($r=0.67^*$). The latter therefore depended on high amount of carbohydrate rather than nitrogen in the cuttings. 9. The content of RNA and DNA in the cuttings was not changed for upto two weeks after the cuttings were planted. Then an increase in RNA content took place in only the high rootability varieties. 10. There were quantitative and qualitative differences in the compositions of the amino acids between the high rootability varieties and the low rootability varieties. More aspartic acid and cystine were found in the higher rootability varieties than in the low rootability varieties.

  • PDF

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.

Effect of $H_2O_2$ on Alveolar Epithelial Barrier Properties (폐상피세포 장벽에 대한 $H_2O_2$의 영향)

  • Suh, Duk-Joon;Cho, Se-Heon;Kang, Chang-Woon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.236-249
    • /
    • 1993
  • Background: Among the injurious agents to which the lung airspaces are constantly exposed are reactive species of oxygen. It has been widely believed that reactive oxygen species may be implicated in the etiology of lung injuries. In order to elucidated how this oxidant causes lung cell injury, we investigated the effects of exogenous $H_2O_2$ on alveolar epithelial barrier characteristics. Methods: Rat type II alveolar epithelial cells were plated onto tissue culture-treated polycarbonate membrane filters. The resulting confluent monolayers on days 3 and 4 were mounted in a modified Ussing chamber and bathed on both sides with HEPES-buffered Ringer solution. The changes in short-circuit current (Isc) and monolayer resistance (R) in response to the exogenous hydroperoxide were measured. To determine the degree of cellular catalase participation in protection against $H_2O_2$ injury to the barrier, experiments were repeated in the presence of 20 mM aminotriazole (ATAZ, an inhibitor of catalase) in the same bathing fluid as the hydroperoxide. Results: These monolayers have a high transepithelial resistance (>2000 ohm-$cm^2$) and actively transport $Na^+$ from apical fluid. $H_2O_2$(0-100 mM) was then delivered to either apical or basolateral fluid. Resulting indicated that $H_2O_2$ decreased Isc and R gradually in dose-dependent manner. The effective concentration of apical $H_2O_2$ at which Isc (or R) was decreased by 50% at one hour ($ED_{50}$) was about 4 mM. However, basolateral $H_2O_2$ exposure led to $ED_{50}$ for Isc (and R) of about 0.04 mM. Inhibition of cellular catalase yielded $ED_{50}$ for Isc (and R) of about 0.4 mM when $H_2O_2$ was given apically, while $ED_{50}$ for basolateral exposure to $H_2O_2$ did not change in the presence of ATAZ. The rate of $H_2O_2$ consumption in apical and basolateral bathing fluids was the same, while cellualr catalase activity rose gradually with time in culture. Conclusion: Our data suggest that basolateral $H_2O_2$ may affect directly membrane component (e.g., $Na^+,\;K^+$-ATPase) located on the basolateral cell surface. Apical $H_2O_2$, on the other hand, may be largely degraded by catalase as it passes through the cells before reaching these membrane components. We conclude that alveolar epithelial barrier integrity as measured by Isc and R are compromised by $H_2O_2$ being relatively sensitive to basolateral (and insensitive to apical) $H_2O_2$.

  • PDF