STOKES FLOW THROUGH A MICROCHANNEL WITH PROTUBERANCES OF STAGGERED ARRANGEMENT (엇갈린 배열의 돌출물들이 존재하는 마이크로채널 내의 스톡스 유동)

  • Son, Jeong Su;Jeong, Jae-Tack
    • Journal of computational fluids engineering
    • /
    • v.20 no.4
    • /
    • pp.109-115
    • /
    • 2015
  • In this study, the Stokes flow in the microchannel is analysed where the semicircular protuberances with constant spacing are attached on the upper and lower walls with staggered arrangement. For the low Reynolds number flow in microchannel, Stokes approximation is used and the periodicity and symmetry of the flow are considered to determine the stream function and pressure distribution in the flow field by using the method of least squared error. As results, the streamline patterns and pressure distributions in the flow field are shown for some specific values of the size and spacing of the protuberances, and shear stress distributions on the surface of semicircular protuberances are plotted. Especially, for an important physical property, the average pressure gradient along the microchannel is obtained and compared with that for the case of in-phase arrangement of the upper and lower protuberances. And, for the small clearance between the protuberances of upper and lower walls or between the protuberances and the opposite wall, the average pressure gradient is derived from the lubrication theory and compared with that of the present study.

Approximate Multi-Objective Optimization of Scroll Compressor Lower Frame Considering the Axial Load (축하중을 고려한 스크롤 압축기 하부 프레임의 최적설계)

  • Kim, JungHwan;Lee, Jongsoo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.3
    • /
    • pp.308-313
    • /
    • 2015
  • In this research, a multi-objective optimal design of a scroll compressor lower frame was approximated, and the design parameters of the lower frame were selected. The sensitivity of the design parameters was induced through a parameter analysis, and the thickness was determined to be the most sensitive parameter to stress and deflection. All of the design parameters regarding the mass are sensitive factors. It was formulated for the problem about stress and deflection to be caused by the axial load. The sensitivity of the design variables was determined using an orthogonal array for the parameter analysis. Using the central composite and D-optimal designs, a second polynomial approximation of the objective and constraint functions was formulated and the accuracy was verified through an R-square. These functions were applied to the optimal design program (NSGA-II). Through a CAE analysis, the effectiveness of the central composite and D-optimal designs was determined.

Analysis of High Efficiency Small Antenna with Matching Circuit (정합회로 장착 고효율 소형안테나의 해석)

  • Hwang, Jae-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.7
    • /
    • pp.1358-1363
    • /
    • 2012
  • This paper deals with the analysis of high efficiency small antenna like superconductor antenna. The superconductor antenna is useful to low frequency range because surface resistance of superconductor increased with the rate of square of frequency. Thus, the used antenna increases in size. For such a reason, the role of the matching circuit is very important in small antenna. In this paper, low loss antenna included the optimal structure of matching circuit is analyzed by using quasi-static approximation. To verify the results of this paper, input impedance and radiation characteristics of this antenna have been evaluated.

Lift of and Wave Breaking behind a Moving Submerged Body with Shallow Submergence

  • Lee, Seung-Joon;Kim, Hyoung-Tae
    • Journal of Hydrospace Technology
    • /
    • v.2 no.1
    • /
    • pp.1-9
    • /
    • 1996
  • We consider the following two questions mainly in this study. First one is how the free surface hayes affect the lift of a shallowly submerged moving body. For this matte., we reinterpret the theoretical results of Kochin(1936), and point out that the high Froude number approximation is not always on the safer side. Second one is what sort of dimensionless parameters determine the occurrence of wave breaking behind a moving submerged body. Temporarily before getting a better answer, we propose that the two-parameter-plane, namely, the plane of the Froude number and the square root of the ratio of the submerged depth and the body length, may be used for predicting the possibility of wave breaking behind the submerged body. A region in the parameter plane is put forth as that of wave breaking, and the validity of this proposal is shown by its agreement with the existing experimental data of Parkin et al(1955) and those of Duncan(1983). Finally, linear and nonlinear numerical results are compared with the existing experimental data to see in what range of the parameters the linear and nonlinear theory case predict the wave field and the pressure on the body with reasonable accuracy. However, since the experimental data, which offer both the pressure and wave elevation for a submerged moving body, are very scarce, much cannot be attained through this comparative study. Hence, it is strongly recommended to carry out well planned experiments to get such data.

  • PDF

Parabolic mirror test using Computer Generated Hologram (Computer Generated Hologram을 이용한 포물명경 형상측정)

  • 김성하;곽종훈;최옥신;송재봉;이윤우;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.80-84
    • /
    • 2000
  • Parabolic almninium mlITOr of m.5('||'&'||'cent; 50 nun) was fabncated by a diamond tummg machine. Computer generated hologram (CGH) for the test of parabolic mirror was encoded by binary phase hologram Approximation of curved fringe to line was made by staircase encoding. After fringe data 1ransformed mto a Post Scnpt file. magnified master CGH was printed by a laser printer, and then it reduced to the photographIc film. Parabolic mirror was tested by Twyman-Green interferometer with CGH at VIewing arm. Its experimental result was compared with those of surface profile and auto-collimatIon test, and then the errors were analyzed.

  • PDF

Tethered DNA shear dynamics in the flow gradient plane: application to double tethering

  • Lueth, Christopher A.;Shaqfeh, Eric S.G.
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.3
    • /
    • pp.141-146
    • /
    • 2007
  • We examine the wall contact of a $3\;{\mu}m$ tethered DNA chain's free end under shear with a focus on developing schemes for double-tethering in the application of making scaffolds for molecular wires. At this scale our results are found to be highly dependent on small length scale rigidity. Chain-end-wall contact frequency, mean fractional extension deficit upon contact, and standard deviation in extension upon contact are examined for scaling with dimensionless flow strength, Wi. Predictions made using a one dimensional approximation to the Smoluchowski equation for a dumbbell and three dimensional dumbbell simulations produce extension deficit, standard deviation, and frequency scaling exponents of -1/3, -1/3, and 2/3, respectively whereas more fine-grained Kratky-Porod (KP) simulations produce scaling exponents of -0.48, -0.42, and 0.76. The contact frequency scaling of 2/3 is derived from the known results regarding cyclic dynamics Analytical scaling predictions are in agreement with those previously proposed for ${\lambda}-DNA$. [Ladoux and Doyle, 2000, Doyle et al., 2000]. Our results suggest that the differences between the dumbbell and the KP model are associated with the addition of chain discretization and the correct bending potential in the latter. These scaling results will aide future exploration in double tethering of DNA to a surface.

A Study, on the Minimum Oil Film Thickness of Connecting-rod Bearing in Engine (엔진 연결봉 베어링의 최소 유막 두께에 관한 연구)

  • Choi, Jae-Kwon;Hur, Kon;Han, Dong-Chul
    • Tribology and Lubricants
    • /
    • v.10 no.1
    • /
    • pp.14-26
    • /
    • 1994
  • The minimum oil film thickness(MOFT) in the connecting-rod bearing of a 1.5 liter, L-4, gasoline engine is measured up to 5500 rpm and calculated to study the dynamically loaded engine bearing. Short bearing approximation and Mobility method are used for theoretical analysis of oil film characteristics. And cylinder pressure, crank-pin surface temperature and bearing temperature are measured as the input data of theoretical analysis. The MOFT are measured by the total capacitance method(TCM). To improve the reliability of the test results, a reasonable determination method of bearing clearance is introduced and used, and the effects of cavitation and aeration on the test results are neglected. The crankshaft is grounded by means of a slip ring. A scissor type linkage system was developed to measure the MOFT and bearing temperature. The effects of engine speed, load and oil viscosity on the measured and calculated minimum oil film thicknesses are investigated at 1500 to 5500 rpm. From the comparison between the measured and calculated MOFT, it is found that a qualitative similarity exists between them, but in all cases, the measured MOFT are smaller than those calculated.

Peierls Instability and Spin Ordering in Graphene

  • Kim, Hyeon-Jung;Jo, Jun-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.204-204
    • /
    • 2012
  • Peierls instability and spin ordering of zigzag graphene nanoribbons (GNR) created on a fully hydrogenated graphene (graphane) are investigated as a function of their width using first-principles density-functional calculations within the generalized-gradient approximation. For the width containing a single zigzag C chain (N=1), we find the presence of a Peierls instability with a bond alternated structure. However, for width greater than N=1, the Peierls distortion is weakened or disappears because of the incommensurate feature of Fermi surface nesting due to the interaction of C chains. Instead, there exists the antiferromagnetic (AFM) spin ordering in which the edge states are ferromagnetically ordered but the two ferromagnetic (FM) edges are antiferromagnetically coupled with each other, showing that electron-lattice coupling and spin ordering in GNR are delicately competing at an extremely thin width of N=2. It is found that, as the width of GNR increases, the energy gain arising from spin ordering is enhanced, but the energy difference between the AFM and FM (where two edge states are ferromagnetically coupled with each other) orderings decreases.

  • PDF

Human-like Arm Movement Planning for Humanoid Robots Using Motion Capture Database (모션캡쳐 데이터베이스를 이용한 인간형 로봇의 인간다운 팔 움직임 계획)

  • Kim, Seung-Su;Kim, Chang-Hwan;Park, Jong-Hyeon;You, Bum-Jae
    • The Journal of Korea Robotics Society
    • /
    • v.1 no.2
    • /
    • pp.188-196
    • /
    • 2006
  • During the communication and interaction with a human using motions or gestures, a humanoid robot needs not only to look like a human but also to behave like a human to make sure the meanings of the motions or gestures. Among various human-like behaviors, arm motions of the humanoid robot are essential for the communication with people through motions. In this work, a mathematical representation for characterizing human arm motions is first proposed. The human arm motions are characterized by the elbow elevation angle which is determined using the position and orientation of human hands. That representation is mathematically obtained using an approximation tool, Response Surface Method (RSM). Then a method to generate human-like arm motions in real time using the proposed representation is presented. The proposed method was evaluated to generate human-like arm motions when the humanoid robot was asked to move its arms from a point to another point including the rotation of its hand. The example motion was performed using the KIST humanoid robot, MAHRU.

  • PDF

Measurement of Absorption and Scattering Coefficients of Biological Tissues by Time-Resolved Reflectance Method (시간 분해 반사율에 의한 생체조직의 흡수계수와 산란계수 측정)

  • Jeon, Kye-Jin;Park, Seung-Han;Kim, Ung;Yoon, Gil-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.499-505
    • /
    • 1997
  • A non-invasive technique to measure absorption and scattering coefficients was investigated The reflected backscattered light from the surface of phantom and biological tissue was obtained by using a time-correlated single photon counting system in pico-second time domain. The absorption and scattering coefficients were acquired by the time of peak and asymptotic behavior of the time-resolved reflectance curve and agreed well the ones that is obtained with deconvolution method It was found that the approximation method was good for biological medium to calculate optical properties due to its convenience and accuracy.

  • PDF