A survey on the EMF Levels of Study and Electric Appliances in Korea (국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사)

  • Jang, Seong Ki;Cho, Yong Sung;Lee, Seok Jo;Yoo, Seong Wha;Jung, Kyung Mi;Lim, Jun Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

Classification of Transport Vehicle Noise Events in Magnetotelluric Time Series Data in an Urban area Using Random Forest Techniques (Random Forest 기법을 이용한 도심지 MT 시계열 자료의 차량 잡음 분류)

  • Kwon, Hyoung-Seok;Ryu, Kyeongho;Sim, Ickhyeon;Lee, Choon-Ki;Oh, Seokhoon
    • Geophysics and Geophysical Exploration
    • /
    • v.23 no.4
    • /
    • pp.230-242
    • /
    • 2020
  • We performed a magnetotelluric (MT) survey to delineate the geological structures below the depth of 20 km in the Gyeongju area where an earthquake with a magnitude of 5.8 occurred in September 2016. The measured MT data were severely distorted by electrical noise caused by subways, power lines, factories, houses, and farmlands, and by vehicle noise from passing trains and large trucks. Using machine-learning methods, we classified the MT time series data obtained near the railway and highway into two groups according to the inclusion of traffic noise. We applied three schemes, stochastic gradient descent, support vector machine, and random forest, to the time series data for the highspeed train noise. We formulated three datasets, Hx, Hy, and Hx & Hy, for the time series data of the large truck noise and applied the random forest method to each dataset. To evaluate the effect of removing the traffic noise, we compared the time series data, amplitude spectra, and apparent resistivity curves before and after removing the traffic noise from the time series data. We also examined the frequency range affected by traffic noise and whether artifact noise occurred during the traffic noise removal process as a result of the residual difference.

Evaluation of the Mechanical Properties of Field-Cast Shotcrete and Long-Term Durability by Combined Deterioration Test (현장타설 숏크리트의 역학적 성능 평가 및 복합열화시험을 통한 장기내구성 평가)

  • Ma, Sang-Joon;Jang, Phil-Sung;Kim, Dong-Min;Choi, Jae-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.47-56
    • /
    • 2007
  • Recently, tunnels are increasingly constructed in this country with the increased construction of highways, high-speed railways and subways. Shotcrete is one of the major processes in the tunnel construction. Many problems, however, exist in the current shotcrete practice. The purpose of the study is, therefore, to explore the trobles in the current shotcreting practice, and to develop high-quality silica fume shotcrete. For the purpose of security a long-term durability of shotcrete, this study conducted combined deterioration tests. In this study, a combined deterioration test in consideration of a variety of deterioration factors were proceeded. Especially, micro-silica fume that was used frequently in overseas because of a outstanding strength-promotion effect was applied to combined deterioration test, and a long-term durability of shotcrete was investigated according to additions mixing. As a result of test, the shotcrete mixed Micro-silica fume showed a good deterioration quality compared with the other mixes. And is shows that the Micro-silica fume has an outstanding strength-promotion effect and is effective to secure a long-term durability of shotcrete by means of decreasing a deterioration caused by steel fiber mixed.

Applications of Improved Low-Flow Mortar Type Grouting Method for Road Safety and Constructability in Dangerous Steep Slopes (급경사지 붕괴 위험지역의 도로 안전 및 시공성을 고려한 개선된 저유동 몰탈형 그라우팅공법 적용성 분석)

  • Choi, Gisung;Kim, Seokhyun;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.4
    • /
    • pp.409-415
    • /
    • 2020
  • Low-flow mortar injection method grouting technology was selected and the traffic area was preserved as much as possible in order to secure safety for road traffic when the outflow and subsidence of landfill occurred due to ground-water, and etc. In particular, the current existing method was newly improved since there are risks of damage such as hydraulic fracturing at the lower part of the road, spilling of soil particles on steep slopes, and bumps on the road due to excessive injection pressure during construction. This study was carried out at the site of reinforcement work on the road as a maintenance work for the danger zone for collapse of the steep slope of the 00 hill, which was ordered from the 00 city 00 province. The improved low-flow mortar type grouting method adopted a new automated grouting management system and especially, it composites the method for grouting conditions decision by high-pressure pre-grouting test and injection technology by AGS-controlled and studied about grouting effect analysis by using new technology. By applying the improved low-flow mortar type grouting method, it was possible to lay the groundwork for road maintenance work such as the prevention of subsidence of old roads, uneven subsidence of buildings and civil engineering structures, and of soil leakage of ground-water spills. Furthermore, the possibility of application on future grouting work not only for just construction that prevents subsidence of old roads but also for various buildings and civil engineering structures such as railroads, subways, bridges, underground structures, and boulder stone and limestone areas was confirmed.

A Comparative Study on PM10 Source Contributions in a Seoul Metropolitan Subway Station Before/After Installing Platform Screen Doors (서울시 지하철 승강장의 스크린도어 설치 전·후 PM10 오염원의 기여도 비교 연구)

  • Lee, Tae-Jung;Jeon, Jae-Sik;Kim, Shin-Do;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.543-553
    • /
    • 2010
  • Almost five million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan. As the subway system is typically a closed environment, indoor air pollution problems frequently occurs and passengers complain of mal-health impact. Especially $PM_{10}$ is well known as one of the major pollutants in subway indoor environments. The purpose of this study was to compare the indoor air quality in terms of $PM_{10}$ and to quantitatively compare its source contributions in a Seoul subway platform before and after installing platform screen doors (PSD). $PM_{10}$ samples were collected on the J station platform of Subway Line 7 in Seoul metropolitan area from Jun. 12, 2008 to Jan. 12, 2009. The samples collected on membrane filters using $PM_{10}$ mini-volume portable samplers were then analyzed for trace metals and soluble ions. A total of 18 chemical species (Ba, Mn, Cr, Cd, Si, Fe, Ni, Al, Cu, Pb, Ti, $Na^+$, $NH_4^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, and ${SO_4}^{2-}$) were analyzed by using an ICP-AES and an IC after performing proper pre-treatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the source of particulate matters. $PM_{10}$ for the station was characterized by three sources such as ferrous related source, soil and road dust related source, and fine secondary aerosol source. After installing PSD, the average $PM_{10}$ concentration was decreased by 20.5% during the study periods. Especially the contribution of the ferrous related source emitted during train service in a tunnel route was decreased from 59.1% to 43.8% since both platform and tunnel areas were completely blocked by screen doors. However, the contribution of the fine secondary aerosol source emitted from various outside combustion activities was increased from 14.8% to 29.9% presumably due to ill-managed ventilation system and confined platform space.

Indicators and Planning Features of Ecologically Based Urban Regeneration -Cases from Hamburg, Germany and Copenhagen, Denmark (생태기반형 도시재생의 계획지표 및 특성에 관한 연구 -독일 함부르크와 덴마크 코펜하겐 사례를 중심으로)

  • Rhee, Bum-Hun;Chang, Dong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.158-166
    • /
    • 2018
  • Contrary to urban development, urban regeneration is a process of land development through conservation, restoration, and management. In particular, ecologically based urban regeneration is an attempt to improve the quality of life in an area, establish a stable settlement space, and revitalize the local economy by considering the ecological environment. In this regard, the objectives of this study were to establish theoretical concepts and analyze the successful foreign cases of ecologically based urban regeneration, and propose a direction of socio-economic regeneration along with the physical-environmental regeneration of urban areas in Korea. The study results suggest the following. First, strategies must be developed to coordinate public transportation, such as buses and subways, by considering the importance of bicycle riders, along with the sustainable-commuting system. Second, both the importance of planning parks and trails around water systems in various scales while maintaining the existing natural environment as well as using natural elements, such as electric vehicles and wind-power generation systems, were emphasized. Third, urban regeneration for increased energy efficiency requires specific architectural planning and facilities. Fourth, education and research for easy access by the public, as well as public-private partnership, will be needed in the regeneration process.

PC Interlocked Terminal-based Public Offices Fees Payment Management System (PC 연동 단말기 기반의 관공서 제세공과금 수납관리 시스템)

  • Shin, Dong-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.5
    • /
    • pp.50-60
    • /
    • 2009
  • Recently, the traffic card is gradually utilized and its several supplementary services have been significantly developed. Particularly, since it is possible to pay fees for buses, taxies, subways, parking and tollgates with only one traffic card, new payment method for economically processing has been focused. This paper presents a new receipt management system which allows possibly paying with several digital cards through PC interfacing terminals. The proposed system is mainly composed of three parts: terminals, middleware, and management servers. A terminal part includes processing module for payment/charging and credit/check/debit cards, etc and its operation is fulfilled through a middleware part. A main task of a middleware part is to connect a terminal part to managing servers through middleware applications. Additionally, processing of several receipt items and monitoring of the terminals to product statistical reports based on the processed result are carried out in the middleware. A management sever part is accomplished for collecting all of transaction histories against users and charging items over allowed province and managing statistical information. The proposed system is currently utilized in the Nam-GU district office and the Nam-GU district health center, Busan, S. Korea, respectively for testing its effectiveness. We conclude from this demonstration that the system is more useful and efficient than the previous processing method especially in that variable payment ways are provided and consumption burden is reduced.

A Study on $CO_2$ and PM10 Changes by Operation of KTX HVAC-Pressurization Equipment in Tunnel Sections (터널구간 운행시 KTX HVAC-여압장치 작동에 따른 $CO_2$와 PM10 변화연구)

  • So, Jin-Sub;Yoo, Seong-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.723-729
    • /
    • 2007
  • The Ministry of Environment established a guide line in December 2006, "Indoor Air Quality Management guidelines in Public Facilities." As the items of the guideline, $CO_2$ (Carbon dioxide) and PM10 (particulate matter) is shown to Level 1 and 2. Therefore trains and subways are included. There are a lot of tunnels by the lay of mountains on KTX (Korean Train Express) service. HVAC (Heating Ventilating and Air-conditioning)-pressurization equipment on KTX is various functioning flaps blocking outside pressure waves. At that time, the fresh air is blocked by flap operation and the air is circulated by return air. In this study, we measured the time series of $CO_2$ and PM10 concentrations in the KTX passenger cabin during the train service of Gyongbu line (Seoul-Busan) and Honan line (Yongsan-Mokpo) from July 2006. Also, analyzed the air quality by operation of KTX HVAC-pressurization equipment in tunnel passing point. As a result, PM10 concentration was totally lower than the regulation values. However, $CO_2$ was highly correlated with several tunnels, such as Oksan-Otan, Godeung-Hyudae and Gaechak-Iijik tunnel. but, the indoor air quality of KTX train have been proved satisfy the recommendation the Ministry of Environment guidelines.

Analysis for Willingness to Pay of the Advanced Railway System (차세대전동차 시스템 도입에 따른 이용자 지불의사금액 결정요인분석)

  • Ha, Oh-Keun;Kim, Yong-Jin;Oh, Mi-Young;Park, Dong-Joo;Lee, Soo-Beom
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.4
    • /
    • pp.113-122
    • /
    • 2010
  • Research and development related to advanced railway systems is currently underway presently to promote the maintenance and economic feasibility of subways, and the aim of such research and development is to enhance the functionality, passenger convenience, system safety and reliability assurance of the subway. In this situation, a study that predicts the effect that the development of such an advanced railway system would have on subway users is required. To this end, this study derived willingness to pay and decision factors with the introduction of an advanced railway system after surveying passengers who use subway lines 1~8. The Price Sensitivity Method (PSM) was applied to derive the willingness to pay in relation to user convenience (operating speed, ride comfort, safety, comfort, security and informativeness) with the introduction of an advanced railway system. In addition, willingness to pay and decision factors were examined after explaining the effects of introducing an advanced railway system in detail to subway users. Through the analysis, it was found that willingness to pay amounted to a premium of 148 won ~ 161 won with the introduction of an advanced railway system, and that this was affected by factors such as gender, frequency of use, satisfaction with comfort, and satisfaction with security.

The Smart Electronic Tagging System for Sexual Offenses Prevention Context-Aware Services in Extreme Situations such as Location Unrecognized (위치인식 불가의 극한상황에서 성범죄 예방 상황인지 서비스를 위한 스마트 전자발찌 시스템)

  • Lee, Gil-Yong;Park, Soo-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.118-131
    • /
    • 2012
  • The existing electronic tagging system traces the location of a sex offender through communicating with GPS satellites and mobile phone base stations in order to prevent repeated crimes. However, the GPS satellite communication method does not work well in the interiors of downtown buildings or on the subways where it is difficult to receive satellite signals. In such cases, the location can be traced through communication with mobile phone base stations. But the distance between mobile phone base stations is several hundred meters, and as a result the margin of error for location tracing can be maximum of 2km in accuracy reduction. Take for example, if a kindergarten is located on the 2nd floor and a coffee shop and the sex offender are located on the 3rd floor in a 5-story building that is downtown, the existing electronic tagging system cannot trace the location of the sex offender as the GPS satellite communication does not work in the interior of the building and the exact floor that the sex offender is located on cannot be recognized through communication with mobile phone base stations. This occurrence is a big problem for the existing electronic tagging system, which is based on position recognition. Therefore, this study suggests a smart electronic tagging system that can monitor sex offenders by using a Ubiquitous Sensor Network in such extreme situations where position recognition is not possible.