• Title/Summary/Keyword: subway system

Search Result 859, Processing Time 0.051 seconds

Development of M2M-based Underground Space (subway) Disaster Response Network and EL Display Integrated Board (M2M기반 지하공간(지하철) 재난대응 네트워크 및 EL 디스플레이 통합 보드 개발)

  • Park, Miyun;Kwon, Segon;Park, EunChurn;Lee, Jeonhun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.422-441
    • /
    • 2017
  • Notifying emergency evacuation methods, accurate disaster location and evacuation route guidance can be very active alternatives to quickly minimize evacuation and casualties in disaster situation in the development of subway disaster prevention detection system that detects the disaster signs at the subway station early on the basis of Internet of things and leads passengers to evacuate. It's not easy to ensure perfect functioning of fire fighting facilities and equipments due to underground space structure with narrow exits. Therefore, we developed disaster provision EL Display integrated board that can induce the most efficient evacuation and the field experiment was conducted to examine the practical application in this study. Especially the applicability was verified by field application test because there is no case in which EL panels are used to evacuate disasters.

A study on the analysis and counterplan of Line 5 EMU Inverter Failure (서울 지하철 5호선 전동차 인버터장치의 장애 분석)

  • Choi, Yong-Woon;Koo, Jeong-Seo;You, Won-Hee;Koh, Hyo-In
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.509-517
    • /
    • 2008
  • Rolling stock is the method of railway transportation. Especially, in the subway system which has short headways particularly during the rush hours, even one train's trouble on the main line might influence the whole line. Accordingly, to prevent a train trouble on the main line, high expense is used for the maintenance parts, workforce and facilities, etc. according to the preventive maintenance program. Therefore, in designing a EMU, emphasis should be put on the minimization of trouble and its extending influence on the mainline with the priority of safety and reliability. Seoul subway line 5 is the line that complements the first stage Seoul subway(lines 1,2,3 and 4) and is built deeply with many curved sections causing lots of dust. Studies were made to find out the importance of car design, selection of specifications and continuous maintenance on the basis of the analysis and countermeasure of the line 5 EMU inverter trouble case.

  • PDF

Damage Analysis of Train Rail Fishplate (전동차 선로 이음매 판의 파손 해석)

  • Seo-Hyun Yun;Byoung-Chul Choi;Ki-Hang Shin;Ki-Woo Nam
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.341-347
    • /
    • 2023
  • The subway is one of the most common and important means of transportation in modern society. In order to use the subway safely, tracks are necessary, but trains are prone to derailment and collisions. In order for the train to run safely on the track, the fishplate that connects the line connection is used. The damaged railway was a fishplate for connecting subway lines used for 11 years, and damage analysis and countermeasures were presented. Beach marks were observed on both fracture surfaces, and striations appeared at the range of crack propagation. The damaged part is Cr carbide, which has a higher hardness than the base metal, and is judged to be embrittled and destroyed by fatigue. The SM50C fishplate was subjected to a cyclic stress of about 59% of the upper limit of tensile-compression fatigue limit, but inclusions were the cause of failure. In order to prevent fatigue failure of the SM50C steel fishplate, the occurrence of inclusions should be minimized and processed to have a homogeneous structure when manufacturing the fishplate. In addition, compressive residual stress is given through surface modification such as peening to control crack generation. It is necessary to minimize the change in shape that can become a stress concentration part along with accurate fastening of the bolt, and to design the stress distribution to be as uniform as possible.

A Comparative Analysis on Performance of Transport Facilities in Subway for Vulnerable Pedestrians and Non-Vulnerable Pedestrians Using Modified-IPA (M-IPA를 이용한 장애인과 일반인 지하철 이동시설만족도 비교 연구)

  • Kim, Tae Ho;Son, Sang Ho;Park, Je Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6D
    • /
    • pp.703-709
    • /
    • 2009
  • This article analyzes the obtained data on consciousness survey of disabled and non-disabled pedestrians, and proposes fundamental data for public strategy in order to enhance facilities in subway stations in advance. This paper conduct literature review, new listing survey related to 'The Code for Improvement of Convenience for Moving Vulnerable Pedestrians', and Modified-Importance-Performance Analysis (M-IPA). The results show that disabled pedestrians want enhancement in information facilities as a whole. In addition, the results show that several improvements needs to be applied to accessible sidewalk, to informative notification, to alarm and evacuation system and to toilet for disabled pedestrians. This indicates that disabled pedestrians heavily concentrate on accessibility to subway station and provided information compared with disabled pedestrians.

Characteristic Assessment of Heavy Metals in Dusts Collected by the Air Filtration System at Subway Stations in Daegu, Korea (대구지역 지하철역사 공기여과필터 포집먼지에 함유된 중금속성분의 특성평가)

  • Do, Hwa-Seok;Song, Hee-Bong;Shin, Dong-Chan;Kwak, Jin-Hee;Lee, Myoung-Sook;Yoon, Ho-Suk;Kang, Hye-Jung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Samples of subway dust were collected by the air filter system of 30 subway stations on Daegu subway line 1 in January 2008. Samples were sieved below 100 ${\mu}m$, and 14 elements were analyzed using ICP after acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na, V were influenced by natural sources such as weathered rock and resuspended soil, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources such as fuel combustion and waste incineration. Concentrations were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic sources were significantly affected by indoor dusts than outdoor dusts. Results of pollution indices of heavy metals indicated that indoor dusts were more contaminated with heavy metal ions than outdoor dusts. The correlation analysis among trace elements indicated that components were much correlated in the order of natural sources-anthropogenic sources, anthropogenic sources-anthropogenic sources, natural sources-natural sources in both indoor and outdoor dusts. Trace element components of outdoor dusts were largely correlated than those of indoor dusts. In addition, indoor dusts were significantly affected by outdoor dusts rather than depth from the surface or the average daily number of subway passengers.

Development of Hi-efficiency Direct Drive PMAC Controller for Screen Door (스크린도아용 고효율 직접구동 PMAC Driver 개발)

  • Park, Jae-Sam
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.7
    • /
    • pp.35-41
    • /
    • 2012
  • To control screen door installed in the subway platform, geared BLDC motors have been being used. However, because of the geared mechanisms, the control profile of the screen door in slow speed is very poor. Moreover, geared mechanism tends to leads system malfunctions and low efficiency. To overcome those problems, in this paper, the techniques of developing hi-efficiency direct drive gearless PMAC motor controller and application example to control the screen door of subway platforms are proposed. The developed system has advantages that; the energy efficiency has been increased by adopting gearless PMAC motor; the system break-down factor has been decreased due to the actuator mechanism has been simplified. In this paper, the screen door control system structure, PMAC motor drive circuit design, implementations of vector control algorithm, and test results are shown.

Development of Inspection System for Crack on the Lining of Concrete Tunnel (콘크리트 터널 라이닝 균열검사 시스템 개발에 관한 연구)

  • 고봉수;손영갑;신동익;김병화;한창수
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.1
    • /
    • pp.66-72
    • /
    • 2004
  • To assess tunnel safety, cracks in tunnel lining are measured by inspectors, who observe cracks with their naked eyes and record them. But manual inspection is slow, and measured crack data is subjective. Therefore, this study proposes inspection system fur measuring cracks in tunnel lining and providing objective crack data to be used in safety assessment. The system consists of On-vehicle system and Laboratory system. On-Vehicle system acquires image data with line CCD camera on scanning along the tunnel lining. Laboratory system extracts crack information from the acquired image using image processing. Measured crack information is crack thickness, length and orientation. To improve accuracy of crack recognition, the geometric properties and patterns of cracks in concrete structure were applied to image processing. The proposed system was verified with experiments in both laboratory environment and field environment such as subway tunnel.

Analysis of the system requirements by EMU operating types (도시철도 운전형태별 시스템 구비요건 분석 연구)

  • Hong, Yong-Ki;Chung, Jong-Duk;Pyun, Jang-Sik
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.536-543
    • /
    • 2008
  • When the electric motor car was first introduced, an engineer, responsible for the work related to operation and a conductor for the announcement and management of entrances and the other services like as monitoring the passengers in the platforms used to take together the train for passengers' safe. As new technologies developed and the urban transit system had the automatic driving facilities, automatic door switch and broadcasting systems, to solve the financial problems, most subway systems introduced the one-man operation system. To curtail the operating expense through automatic control and operation for the economical efficiency, the crewless driving system was introduced abroad around 1970 on the light weight train and Japan started the crewless driving system in 2005, Germany started it in June 2008. We examine system requirements of the system and methods to construct safe systems that would be introduced, suitable for one-man operation system or crewless driving system through the surveys and analysis of driving state and the systems.

  • PDF

Development of the Fuzzy Expert System for the Reinforcement of the Tunnel Construction (터널 시공 중 보강공법 선정용 퍼지 전문가 시스템 개발)

  • 김창용;박치현;배규진;홍성완;오명렬
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.101-108
    • /
    • 2000
  • In this study, an expert system was developed to predict the safety of tunnel and choose proper tunnel reinforcement system using fuzzy quantification theory and fuzzy inference rule based on tunnel information database. The expert system developed in this study have two main parts named pre-module and post-module. Pre-module decides tunnel information imput items based on the tunnel face mapping information which can be easily obtained in-situ site. Then, using fuzzy quantification theory II, fuzzy membership function is composed and tunnel safety level is inferred through this membership function. The comparison result between the predicted reinforcement system level and measured ones was very similar. In-situ data were obtained in three tunnel sites including subway tunnel under Han river, This system will be very helpful to make the most of in-situ data and suggest proper applicability of tunnel reinforcement system developing more resonable tunnel support method from dependance of some experienced experts for the absent of guide.

  • PDF

Determinant Factors for the Apartment Unit Prices of Large Scale Apartment Complexes over 1,000 Households in Seoul Metropolitan Area (서울시 1,000세대 이상 대규모 아파트단지의 아파트가격 결정요인에 관한 연구)

  • Kim, Kwang-Young;Ahn, Jeong-Keun
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.81-90
    • /
    • 2010
  • The existing most studies on the apartment sales prices have been limited to relatively small size apartment complexes and have not categorized the apartment complexes based on the number of households. Some of them uses the apartment-related indices such as regional value estimates, sales unit price, and view right values. In the case of Seoul Metropolitan Area, the size of apartment complex has been growing to the level of large complex over more than 1,000 households through new town development, redevelopment and reconstruction. People prefers to choose a large scale complex instead of small complex based on their perception that a large scale apartment complex provides more conveniences in living. The result of this analysis revealed that the variables chosen as important determinants of the hedonic price model for large scale apartment complexes were square meters of apartment unit, rent/price ratio, number of bays, distance to the nearest subway station, and heating system method. This means that the sales price of apartment unit will be higher as the square meters of apartment unit increase, as the rent/price ratio decreases, as the distance to the nearest subway station increases, and as the number of bays increase.